998 resultados para 234Th int


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inflammatory papillary hyperplasia of the palate (IPHP) is a tissue-reactive overgrowth characterized by hyperemic mucosa with nodular or papillary appearance in the palate. The exact pathogenesis is still unclear. In this study, the presence of Candida albicans in the epithelial lining was evaluated using the indirect immunofluorescence staining technique. Strongly stained C albicans was observed only in the lesions of the IPHP group. Therefore, the detection of C albicans in almost all samples from IPHP tissue enabled a suggestion as to the microbial etiology of the disease, since the use of dental prostheses was reported. Int J Prosthodont 2011;24:235-237

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the effect of oral rehabilitation with immediately loaded fixed implant-supported mandibular prostheses on chewing and swallowing in elderly individuals. Materials and Methods: Fifteen completely edentulous patients aged more than 60 years (10 women and five men), wearing removable dentures in both arches, had a mandibular denture replaced by an implant-supported prosthesis. All individuals were evaluated before surgery and again 3, 6, and 18 months later with regard to mastication and swallowing conditions. Examinations entailed an interview, evaluation of tactile sensitivity of the face, and observation of food intake, masticatory type, formations of bolus, and pain during mastication. The swallowing evaluation comprised observation of clinical signs related to the oral and pharyngeal stages of swallowing, as well as the presence of oral residue. The findings of different evaluations before and 3, 6, and 18 months after the surgical-prosthetic procedure were statistically compared by analysis of variance for repeated measurements at a significance level of 5%. Results: The questionnaire revealed a reduction in complaints of masticatory and swallowing disturbances, a decreased need for liquid ingestion, and reduced choking and coughing. Clinical evaluations showed improved oral function and bolus propulsion for both solid and paste-consistency foods; pain during mastication was also resolved. Conclusion: Treatment with mandibular implant-supported dentures had positive effects on the clinical aspects of mastication and swallowing in elderly individuals. INT J ORAL MAXILLOFAC IMPLANTS 2009; 24:110-117

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate whether the type of cola drink (regular or diet) could influence the wear of enamel subjected to erosion followed by brushing abrasion, Method and !Materials: Ten volunteers wore intraoral devices that each had eight bovine enamel blocks divided into four groups; ER, erosion with regular cola; EAR, erosion with regular cola plus abrasion; EL, erosion with light cola; and EAL, erosion with light cola plus abrasion, Each day for 1 week, half of each device was immersed in regular cola for 5 minutes, Then, two blocks were brushed using a fluoridated toothpaste and electric toothbrush for 30 seconds four times daily, Immediately after, the other half of the device was subjected to the same procedure using a light cola, The pH, calcium, phosphorus, and fluoride concentrations of the colas were analyzed using standard procedures, Enamel alterations were measured by profilometry. Data were tested using two-way ANOVA and Bonferroni test (P < .05), Results: Regarding chemical characteristics, light cola presented pH 3.0, 13.7 mg Ca/L, 15.5 mg P/L, and 0.31 mg F/L, while regular cola had pH 2.6, 32.1 mg Ca/L, 1:8.1 mg P/L, and 0.26 mg F/L, The light cola promoted less enamel loss (EL, 0.36 pm; EAL, 0.39 pm) than its regular counterpart (ER, 0.72 pm; EAR, 0.95 pm) for both conditions, There was not a significant difference (P > .05) between erosion and erosion plus abrasion for light cola, However, for regular cola, erosion plus abrasion resulted in higher enamel loss than erosion alone,.nclusion: The data suggest that light cola promoted less enamel wear even when erosion was followed by brushing abrasion, (Quintessence Int 2011;42:xxx-xx)()

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the effect of framework design on the fracture resistance of metal-ceramic implant-supported crowns. Screw-retained molar crowns with a screw access hole composed of metal or porcelain were compared to a cement-retained crown (control). For each group (n = 10), five crowns were subjected to dynamic loading (1,200,000 x 100 N x 2 Hz at 37 degrees C). Afterward, all specimens were loaded to failure using a universal testing machine. Significant differences could be established between the cement-and screw-retained groups (P <= .05), but no difference was found between the screw-retained groups and the specimens subjected to dynamic loading. Occlusal discontinuity of screw-retained crowns affects their resistance, and the metallic support on the screw access hole did not reinforce the crowns. Int J Prosthodont 2010;23:350-352.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate histologically the root surfaces of teeth submitted to orthodontic and surgical extrusion procedures in a dog model. Eighteen adult male dogs, divided into six groups of three dogs each, were used in the study Each animal underwent two procedures: rapid orthodontic extrusion and surgical extrusion of the maxillary lateral incisors. The animals were sacrificed to produce samples at 7, 14, 45, 90, 120, and 180 days after surgery for assessment of cross sections of the coronal, medial, and apical thirds of the treated teeth. At early time points, some active surface and inflammatory resorption was observed exclusively in the surgical extrusion group; however, samples collected at later times demonstrated functional repair of the resorption gaps in both groups. Ankylosis was observed as a minor event and was apparently of a transient nature in samples of the surgical extrusion group. The results demonstrate the importance of maintaining the periodontal ligament and cementum surface; both are vital for the prevention of root resorption. It may be postulated that orthodontic extrusion is more conservative and physiologic than surgical extrusion; however the results showed that function was restored in both groups. (Int J Periodontics Restorative Dent 2009;29:435-443.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Nonpassive fit frameworks are believed to lead to implant overload and consequently loss of osseointegration. This is one of the most commonly reported failures of implant prostheses. In an ideal situation of passive fit, when torque is applied to bring the abutment-cylinder interface together some amount of deformation can be expected, and it should be homogeneous along the periphery of the abutment. The aim of this study was to verify the amount of abutment deformation that can be expected when a free-standing cylinder is screwed into place. This could give insight into what should be accepted as passive fit. Materials and Methods: Strain gauges were bonded to the sides of five standard abutments that had machined palladium-silver cylinders or cobalt-chromium cast cylinders screwed into place. Measurements were taken to verify the deformation at each site. Results: Values of abutment deformation after abutment screw tightening ranged from -127.70 to -590.27 mu epsilon. The deformation recorded for palladium-silver prosthetic cylinder tightening ranged from 56.905 to -381.50 mu epsilon (mean: 173.298 mu epsilon) and from -5.62638 to -383.86 mu epsilon ( mean: 200.474 mu epsilon) for cobalt-chromium cylinders. There was no statistically significant difference among the two groups. Conclusion: Both abutment screw tightening and prosthetic cylinder screw tightening result in abutment deformation, which is compressive most of the time. Int J Prosthodont 2009; 22: 391-395.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article reports the longitudinal follow-up of a familial case of aggressive periodontitis treated by a combined regenerative approach that consisted of root conditioning, bone grafting, and membrane positioning. Treatment resulted in attachment level gain, reduction of probing depth, absence of bleeding on probing, and complete bone filling of the defect. The short-term results obtained after surgery were maintained after 6 years, suggesting that the combined regenerative approach is able to completely arrest the disease with long-term stability. (Int J Periodontics Restorative Dent 2009; 29: 69-79.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this research was to evaluate the fatigue behavior and reliability of monolithic computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate and hand-layer-veneered zirconia all-ceramic crowns. Materials and Methods: A CAD-based mandibular molar crown preparation, fabricated using rapid prototyping, served as the master die. Fully anatomically shaped monolithic lithium disilicate crowns (IPS e.max CAD, n = 19) and hand-layer-veneered zirconia-based crowns (IPS e.max ZirCAD/Ceram, n = 21) were designed and milled using a CAD/CAM system. Crowns were cemented on aged dentinlike composite dies with resin cement. Crowns were exposed to mouth-motion fatigue by sliding a WC-indenter (r = 3.18 mm) 0.7 mm lingually down the distobuccal cusp using three different step-stress profiles until failure occurred. Failure was designated as a large chip or fracture through the crown. If no failures occurred at high loads (> 900 N), the test method was changed to staircase r ratio fatigue. Stress level probability curves and reliability were calculated. Results: Hand-layer-veneered zirconia crowns revealed veneer chipping and had a reliability of < 0.01 (0.03 to 0.00, two-sided 90% confidence bounds) for a mission of 100,000 cycles and a 200-N load. None of the fully anatomically shaped CAD/CAM-fabricated monolithic lithium disilicate crowns failed during step-stress mouth-motion fatigue (180,000 cycles, 900 N). CAD/CAM lithium disilicate crowns also survived r ratio fatigue (1,000,000 cycles, 100 to 1,000 N). There appears to be a threshold for damage/bulk fracture for the lithium disilicate ceramic in the range of 1,100 to 1,200 N. Conclusion: Based on present fatigue findings, the application of CAD/CAM lithium disilicate ceramic in a monolithic/fully anatomical configuration resulted in fatigue-resistant crowns, whereas hand-layer-veneered zirconia crowns revealed a high susceptibility to mouth-motion cyclic loading with early veneer failures. Int J Prosthodont 2010; 23: 434-442.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Enamel white spot lesions in anterior teeth that compromise esthetics are common. Microabrasion is indicated, since it affects enamel superficially. An acid-abrasive slurry with 37% phosphoric acid with pumice was used on the enamel for a controlled time period. Home bleaching with hydrogen peroxide was then used, further improving the final result. The method is safe, easy, and conservative and provides good esthetic results. (Quintessence Int 2011;42:423-426)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the biomechanical fixation, bone-to-implant contact (BIC), and bone morphology of screw-type root-form implants with healing chambers with as-machined or dual acid-etched (DAE) surfaces in a canine model. Materials and Methods: The animal model included the placement of machined (n = 24) and DAE (n = 24) implants along the proximal tibiae of six mongrel dogs, which remained in place for 2 or 4 weeks. Following euthanasia, half of the specimens were subjected to biomechanical testing (torque to interface failure) and the other half were processed for histomorphologic and histomorphometric (%BIC) assessments. Statistical analyses were performed by one-way analysis of variance at the 95% confidence level and the Tukey post hoc test for multiple comparisons. Results: At 4 weeks, the DAE surface presented significantly higher mean values for torque to interface failure overall. A significant increase in %BIC values occurred for both groups over time. For both groups, bone formation through the classic appositional healing pathway was observed in regions where intimate contact between the implant and the osteotomy walls occurred immediately after implantation. Where contact-free spaces existed after implantation (healing chambers), an intramembranous-like healing mode with newly formed woven bone prevailed. Conclusions: In the present short-term evaluation, no differences were observed in BIC between groups; however, an increase in biomechanical fixation was seen from 2 to 4 weeks with the DAE surface. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:75-82

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this in vitro study was to evaluate bacterial leakage along the implant-abutment interface under unloaded conditions. Twelve premachined abutments with plastic sleeves and 12 dental implants were used in this study. Prior to tests of bacterial leakage, samples from the inner parts of the implants were collected with sterile microbrushes to serve as negative controls for contamination. After casting, the abutments were tightened to 32 Ncm on the implants. The assemblies were immersed in 2.0 mL of human saliva and incubated for 7 days. After this period, possible contamination of the internal parts of the implants was evaluated using the DNA Checkerboard method. Microorganisms were found in the internal surfaces of all the implants evaluated. Aggregatibacter actinomycetemcomitans and Capnocytophaga gingivalis were the most incident species. No microorganisms were found in the samples recovered from the implants before contamination testing (negative control). Bacterial species from human saliva may penetrate the implant-abutment interface under unloaded conditions. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:782-787

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Gaps between an abutment and a dental implant are unavoidable, and microleakage may occur, leading to problems such as malodor and peri-implantitis. The aim of the present in vitro study was to investigate leakage of Staphylococcus aureus through the implant/abutment interface by the method of bacterial culture, and to compare the leakage rates of two different types of implant-abutment connections. Materials and Methods: Twenty Morse taper implants with abutments were divided into two groups: group A, which were evaluated for microleakage into the inner part of the implants, and group B, which were evaluated for microleakage from the inner part of the implants. Twenty internal-hexagon implants with abutments were also divided into two groups: group C, which were evaluated for microleakage into the inner part of the implants, and group D, which were evaluated for microleakage from the inner part of the implants. For the evaluation of leakage from the implants, the assemblies had the inner parts inoculated with S aureus, and each assembly was incubated in sterile brain heart infusion broth for 1 week. For assessment of leakage into the implants, each assembly was submerged in 4 mL S aureus culture in tubes and incubated for 2 weeks. The microleakage of the two implant connections was compared. Results: Microbial leakage occurred in all groups, and there was no statistically significant difference between groups A and C or between groups B and D. Conclusions: In vitro, S aureus leakage through the implant/abutment interface occurred with both Morse taper and internal-hexagon implants. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:56-62

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A body of published evidence suggests that a significant portion of enamel matrix protein synthesized by ameloblasts localises in the lysosomal-endosomal organelles of these enamel organ cells. Little is known regarding the lysosomal proteolytic activities during amelogenesis. The aims of this study were to detect and measure the activities of lysosomal peptidases cathepsin B (E.C. 3.4.22.1) and dipeptidyl-peptidase II (E.C. 3.4.14.2) in the enamel organ of the rat incisor and to ascertain whether rat enamel matrix proteins are degraded by these peptidases in vitro. Whole enamel organs were dissected from rat mandibular incisors. Enamel protein was also collected from the rat teeth. Analysis indicated that the rat incisor enamel organs contained specific activities of both dipeptidyl-peptidase II and cathepsin B at levels comparable with those of kidney which is rich in both these lysosomal peptidases. Gel electrophoresis and immunoblotting demonstrated that both cathepsin B and dipeptidyl-peptidase II were able to substantially degrade the rat enamel proteins in vitro. Based on these observations, we propose that lysosomal proteases have roles in amelogenesis in the intracellular degradation of amelogenins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A shortened version of the Interpersonal Sensitivity Measure (IPSM) developed to predict depression prone personalities was administered in a self-report questionnaire to a community-based sample of 3269 Australian twin pairs aged 18-28 years, along with Eysenck's EPQ and Cloninger's TPQ. The IPSM included four sub-scales: Separation Anxiety (SEP); Interpersonal Sensitivity (INT); Fragile Inner-Self (FIS); and Timidity (TIM). Univariate analysis revealed that individual differences in the IPSM sub-scale scores were best explained by additive genetic and specific environmental effects. Confirming previous research findings, familial aggregation for the EPQ and TPQ personality dimensions was entirely due to additive genetic effects. In the multivariate case, a model comprising additive genetic and specific environmental effects best explained the covariation between the latent factors for male and female twin pairs alike. The EPQ and TPQ dimensions accounted for moderate to large proportions of the genetic variance (40-76%) in the IPSM sub-scales, while most of the non-shared environment variance was unique to the IPSM sub-scales. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contemporary research into the sociology of taste has, following Bourdieu (1984), primarily emphasised the role of social position, or more broadly as implicated int he reproduction of social inequality. We argue that although important, such a preoccupation with the social distribution of objectified tastes--for example in music, literature, and art--has been at the expense of investigating the everyday perceptual schemes and resources used by actors to accomplish a judgement of taste. Our argument is traced using a range of classical and contemporary literature which deals with the personal/collective tension in taste, aesthetics and fashion. We use data from a recent national survey to investigate how a sample of ordinary fashion. We use data from a recent national survey to investigate how a sample of ordinary actors understand the categories of 'good' and 'bad' taste. The analysis shows a strong collective strand in everyday definitions of taste, often linked to moral codes of interpersonal conduct. Also, taste is largely defined by people as a strategy for managing relations with others, and as a mode of self-discipline which relies on the mastery of a number of general principles that are resources for people to position their own tastes within an imagined social sphere. This paper proposes a schematic model which accounts for the range of discriminatory resources used to make judgements of taste.