991 resultados para water table


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Vertical electrical soundings using eletroresistivity method were carried out in the public waste landfill in Macapá - AP, having as a goal to investigate the geoelectrical and hidrogeologic characteristics of the ground. The results of geophysics interpretation allowed obtaining a model of five geoelectrical layers until the depth of 14,6 m. This model is correlated to a sedimentary sequence of clay-silt-sandy with laterite. The main flow of the water table, also determined, is concordant to the topographical gradient.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of piezocone tests with a slot filter filled with automotive grease for site characterization of tropical soils is assessed. Laboratory tests using the slot filter filled with automotive grease as well as the conventional porous piezo-element saturated with glycerin were carried out to evaluate the pore pressure (u 2) transducer response. CPTu tests using piezo-elements saturated with glycerin and the slot filter filled with grease were pushed side by side in different research sites in Brazil. Estimates of mechanical and hydraulic soil parameters were made based on pore pressure dissipation curves from using both techniques. Laboratory test results indicate that the pore pressure response using the slot filter with grease was delayed when compared to the piezo-element saturated with glycerin, since grease has a higher viscosity. For tropical soils, the records of u2 in piezocone tests using slot filter with grease presented larger peaks than with porous element saturated with glycerin. Records of u2 using the slot filter above the groundwater table suggest the increase of the degree of saturation in unsaturated zone, where porous filter can be desaturated by suction. The slot filter can be used to help the interpretation of the soil profile with deep groundwater level as well as to help detecting its position for some studied soils. The results shown high repeatability for all study sites. This technique is much easier to handle, especially for tropical soils, where the groundwater table is usually deep and pre-drilling is expensive and time consuming. © 2009 IOS Press.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Due to lack of environmental protection with which the process of burying the corpses was conducted over the decades, many cemeteries have become areas contaminated by organic and inorganic substances and pathogenic microrganisms. This paper presents the results of electrical imaging in delineation of areas potentially contaminated by necrochorume in the municipal cemetery of Vila Rezende, Piracicaba - SP. The results indicate a depth of water table among 3,1 and 5,1 m, with two flow directions, being one to SW and another to SE. So the probable contamination plume, that has the same directions of underground flow, as for the conductive anomalies verified at the geoelectrics sections confirm the suspicions of contamination in the area. The probable plume the SE is prolonged to out of the cemetery. The location of the conductive anomalies and likely contamination plumes demonstrated that the contamination is linked with the depth of water table level and the burial time.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Intending to achieve better results on coffee production, the coffee producers began, since the 80s, to process the coffee postharvest, in order to ensure product's superior quality. However, with the processing, other problem appeared, the contamination of rivers, creeks, soil and water table from coffee wastewater (ARC). This paper had as main objective to use the ARC on the coffee plants' production verifying its viability and if the ARC is able to supply the coffee potassium requirements when they don't receive potassium chloride in the organic compound. The work was developed at Faculdade de Ciências Agronômicas - UNESP, Botucatu-SP, in a greenhouse located at Departamento de Engenharia Rural. The work consisted of 10 treatments on a 5×2 factorial (5 wastewater proportions of coffee after the harvest processing - 0%, 25%, 50%, 75% and 100% - and potassium chloride presence or absence in the composition), with 4 repetitions with a completely randomized statistical design. The ARC was applied each 48 hours in an irrigation depth of 10 mm. After 6 months, the plants' vegetative characteristic had been evaluated as well the chemical characteristics of the compound and of the plants. We observed that the treatments with potassium chloride presence showed worse vegetative characteristics compared with treatments which did not have KCl in its composition. Moreover, with the increase of the wastewater dosage, it happened a decrease in the vegetative characteristics, however an addition in the chemical characteristics of the compound. Also, the treatments without KCl presence and with 0% and 25% of coffee wastewater had been statistically equal, showing the viability in the use of the ARC in the production of coffee plants, since the compound does not contain KCl and that the water used in the composition is a mixture of 25% of ARC with 75% of common water.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Geociências e Meio Ambiente - IGCE

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)