985 resultados para time-resolved fluorescence immunoassay


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrically driven Er3+ doped Si slot waveguides emitting at 1530 nm are demonstrated. Two different Er3+ doped active layers were fabricated in the slot region: a pure SiO2 and a Si-rich oxide. Pulsed polarization driving of the waveguides was used to characterize the time response of the electroluminescence (EL) and of the signal probe transmission in 1 mm long waveguides. Injected carrier absorption losses modulate the EL signal and, since the carrier lifetime is much smaller than that of Er3+ ions, a sharp EL peak was observed when the polarization was switched off. A time-resolved electrical pump & probe measurement in combination with lock-in amplifier techniques allowed to quantify the injected carrier absorption losses. We found an extinction ratio of 6 dB, passive propagation losses of about 4 dB/mm, and a spectral bandwidth > 25 nm at an effective d.c. power consumption of 120 μW. All these performances suggest the usage of these devices as electro-optical modulators.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The structural and optical properties of three different kinds of GaAs nanowires with 100% zinc-blende structure and with an average of 30% and 70% wurtzite are presented. A variety of shorter and longer segments of zinc-blende or wurtzite crystal phases are observed by transmission electron microscopy in the nanowires. Sharp photoluminescence lines are observed with emission energies tuned from 1.515 eV down to 1.43 eV when the percentage of wurtzite is increased. The downward shift of the emission peaks can be understood by carrier confinement at the interfaces, in quantum wells and in random short period superlattices existent in these nanowires, assuming a staggered band offset between wurtzite and zinc-blende GaAs. The latter is confirmed also by time-resolved measurements. The extremely local nature of these optical transitions is evidenced also by cathodoluminescence measurements. Raman spectroscopy on single wires shows different strain conditions, depending on the wurtzite content which affects also the band alignments. Finally, the occurrence of the two crystallographic phases is discussed in thermodynamic terms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gadolinium oxyortho-silicate, Gd2SiO5, presents a monoclinic structure with two crystallographic sites in which Gd3+ ions are equally distributed with coordination numbers CN, 7 and 9, respectively. By doping this host with Er3+ it is possible to distinguish and attribute the two sites by means of lifetime determination of the 4S3/2 state, (in this case, Er3+ substitutes Gd3+ ions). Samples doped with 0.1 and 5.0% molar Er3+ were prepared by solid state reaction and characterized by X-ray Diffractometry, Vibrational and Electronic Absorption Spectroscopies, and Time Resolved Photoluminescence. Based on the experimental results, it is possible to verify that, for the 5,0% doped sample, the lifetime value of the 4S3/2 state of the erbium ion inserted in site 1, (CN = 9), is 2.7 ± 0.1 mus, and for the one inserted in site 2, (CN = 7), it is 1.5 ± 0.1 mus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The preparation of [FeIV(O)(MePy2tacn)]2+ (2, MePy2tacn = N-methyl-N,N-bis(2-picolyl)-1,4,7-triazacyclononane) by reaction of [FeII(MePy2tacn)(solvent)]2+ (1) and PhIO in CH3CN and its full characterization are described. This compound can also be prepared photochemically from its iron(II) precursor by irradiation at 447 nm in the presence of catalytic amounts of [Ru II(bpy)3]2+ as photosensitizer and a sacrificial electron acceptor (Na2S2O8). Remarkably, the rate of the reaction of the photochemically prepared compound 2 toward sulfides increases 150-fold under irradiation, and 2 is partially regenerated after the sulfide has been consumed; hence, the process can be repeated several times. The origin of this rate enhancement has been established by studying the reaction of chemically generated compound 2 with sulfides under different conditions, which demonstrated that both light and [Ru II(bpy)3]2+ are necessary for the observed increase in the reaction rate. A combination of nanosecond time-resolved absorption spectroscopy with laser pulse excitation and other mechanistic studies has led to the conclusion that an electron transfer mechanism is the most plausible explanation for the observed rate enhancement. According to this mechanism, the in-situ-generated [RuIII(bpy)3] 3+ oxidizes the sulfide to form the corresponding radical cation, which is eventually oxidized by 2 to the corresponding sulfoxide

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent years, one important objective of cardiovascular research has been to find new markers that would improve the risk stratification and diagnosis of patients presenting with symptoms of acute coronary syndrome (ACS). Pregnancy-associated plasma protein A (PAPP-A) is a large metalloproteinase involved in insulin-like growth factor signalling. It is expressed in various tissues and seems to be involved in many physiological and pathological processes, such as folliculogenesis, bone formation, wound healing, pregnancy and atherosclerosis. The aim of this thesis was to investigate PAPP-A in ACS patients. Circulating concentrations of PAPP-A had been previously shown to be elevated in ACS. In this study it was revealed that the form of PAPP-A causing this elevation was the free noncomplexed PAPP-A. Thus, the form of PAPP-A in the circulation of ACS patients differed from the complexed PAPP-A form abundantly present in the circulation during pregnancy. A point-of-care method based on time-resolved immunofluorometric assays was developed, which enabled the rapid detection of free PAPP-A. The method was found to perform well with serum and heparin plasma samples as well as with heparinized whole blood samples. With this method the concentrations of free PAPP-A in healthy individuals were shown to be negligible. When the clinical performance of the method was evaluated with serum samples from ACS patients, it was shown that the free PAPP-A concentration in the admission sample was an independent predictor of myocardial infarction and death. Moreover, as a prognostic marker, free PAPP-A was revealed to be superior to total PAPPA, i.e. the combination of free and complexed PAPP-A, which has been measured by the other groups in this field. As heparin products are widely used as medication in ACS patients, the effect of heparin products on free PAPP-A molecule and circulating concentrations were also investigated in this study. It was shown that intravenous administration of low molecular weight or unfractionated heparin elicits a rapid release of free PAPP-A into the circulation in haemodialysis patients and patients undergoing angiography. Moreover, the interaction between PAPP-A and heparin was confirmed in gel filtration studies. Importantly, the patients included in the clinical evaluation of the free PAPP-A detection method developed had not received any heparin product medication before the admission sample and thus the results were not affected by the heparin effect. In conclusion, free PAPP-A was identified as a novel marker associated with ACS. The point-of-care methods developed enable rapid detection of this molecule which predicts adverse outcome when measured in the admission sample of ACS patients. However, the effect revealed of heparin products on circulating PAPP-A concentrations should be acknowledged when further studies are conducted related to free or total PAPP-A in ACS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The product of catalytic activity of the enzyme phospholipase A2, which resembles the core unit of animal toxins, on phospholipids is a 1:1 mixture of lysolipid and fatty acid. This mixture was studied by time-resolved simultaneous small- and wide angle x-ray diffraction over the temperature range from 23 to 53.5ºC. An unusually large lamellar structure was observed, with d = 11 nm, contradicting the complex functional dimer model between lysolipid and fatty acid. It can be explained by formation of a "double-bilayer", a new phase consisting of two different bilayers, one formed by lysophospholipid and other by fatty acid, bound together by head group interactions. Its strucutre was confirmed by simulations of the X-ray scattering pattern.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Binary probes are oligonucleotide probe pairs that hybridize adjacently to a complementary target nucleic acid. In order to detect this hybridization, the two probes can be modified with, for example, fluorescent molecules, chemically reactive groups or nucleic acid enzymes. The benefit of this kind of binary probe based approach is that the hybridization elicits a detectable signal which is distinguishable from background noise even though unbound probes are not removed by washing before measurement. In addition, the requirement of two simultaneous binding events increases specificity. Similarly to binary oligonucleotide probes, also certain enzymes and fluorescent proteins can be divided into two parts and used in separation-free assays. Split enzyme and fluorescent protein reporters have practical applications among others as tools to investigate protein-protein interactions within living cells. In this study, a novel label technology, switchable lanthanide luminescence, was introduced and used successfully in model assays for nucleic acid and protein detection. This label technology is based on a luminescent lanthanide chelate divided into two inherently non-luminescent moieties, an ion carrier chelate and a light harvesting antenna ligand. These form a highly luminescent complex when brought into close proximity; i.e., the label moieties switch from a dark state to a luminescent state. This kind of mixed lanthanide complex has the same beneficial photophysical properties as the more typical lanthanide chelates and cryptates - sharp emission peaks, long emission lifetime enabling time-resolved measurement, and large Stokes’ shift, which minimize the background signal. Furthermore, the switchable lanthanide luminescence technique enables a homogeneous assay set-up. Here, switchable lanthanide luminescence label technology was first applied to sensitive, homogeneous, single-target nucleic acid and protein assays with picomolar detection limits and high signal to background ratios. Thereafter, a homogeneous four-plex nucleic acid array-based assay was developed. Finally, the label technology was shown to be effective in discrimination of single nucleotide mismatched targets from fully matched targets and the luminescent complex formation was analyzed more thoroughly. In conclusion, this study demonstrates that the switchable lanthanide luminescencebased label technology can be used in various homogeneous bioanalytical assays.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prostate cancer is a heterogeneous disease affecting an increasing number of men all over the world, but particularly in the countries with the Western lifestyle. The best biomarker assay currently available for the diagnosis of the disease, the measurement of prostate specific antigen (PSA) levels from blood, lacks specificity, and even when combined with invasive tests such as digital rectal exam and prostate tissue biopsies, these methods can both miss cancers, and lead to overdiagnosis and subsequent overtreatment of cancers. Moreover, they cannot provide an accurate prognosis for the disease. Due to the high prevalence of indolent prostate cancers, the majority of men affected by prostate cancer would be able to live without any medical intervention. Their latent prostate tumors would not cause any clinical symptoms during their lifetime, but few are willing to take the risk, as currently there are no methods or biomarkers to reliably differentiate the indolent cancers from the aggressive, lethal cases that really are in need of immediate medical treatment. This doctoral work concentrated on validating 12 novel candidate genes for use as biomarkers for prostate cancer by measuring their mRNA expression levels in prostate tissue and peripheral blood of men with cancer as well as unaffected individuals. The panel of genes included the most prominent markers in the current literature: PCA3 and the fusion gene TMPRSS2-ERG, in addition to BMP-6, FGF-8b, MSMB, PSCA, SPINK1, and TRPM8; and the kallikrein-related peptidase genes 2, 3, 4, and 15. Truly quantitative reverse-transcription PCR assays were developed for each of the genes for the purpose, time-resolved fluorometry was applied in the real-time detection of the amplification products, and the gene expression data were normalized by using artificial internal RNA standards. Cancer-related, statistically significant differences in gene transcript levels were found for TMPRSS2-ERG, PCA3, and in a more modest scale, for KLK15, PSCA, and SPINK1. PCA3 RNA was found in the blood of men with metastatic prostate cancer, but not in localized cases of cancer, suggesting limitations for using this method for early cancer detection in blood. TMPRSS2-ERG mRNA transcripts were found more frequently in cancerous than in benign prostate tissues, but they were present also in 51% of the histologically benign prostate tissues of men with prostate cancer, while being absent in specimens from men without any signs of prostate cancer. PCA3 was shown to be 5.8 times overexpressed in cancerous tissue, but similarly to the fusion gene mRNA, its levels were upregulated also in the histologically benign regions of the tissue if the corresponding prostate was harboring carcinoma. These results indicate a possibility to utilize these molecular assays to assist in prostate cancer risk evaluation especially in men with initially histologically negative biopsies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measuring protein biomarkers from sample matrix, such as plasma, is one of the basic tasks in clinical diagnostics. Bioanalytical assays used for the measuring should be able to measure proteins with high sensitivity and specificity. Furthermore, multiplexing capability would also be advantageous. To ensure the utility of the diagnostic test in point-of-care setting, additional requirements such as short turn-around times, ease-ofuse and low costs need to be met. On the other hand, enhancement of assay sensitivity could enable exploiting novel biomarkers, which are present in very low concentrations and which the current immunoassays are unable to measure. Furthermore, highly sensitive assays could enable the use of minimally invasive sampling. In the development of high-sensitivity assays the label technology and affinity binders are in pivotal role. Additionally, innovative assay designs contribute to the obtained sensitivity and other characteristics of the assay as well as its applicability. The aim of this thesis was to study the impact of assay components on the performance of both homogeneous and heterogeneous assays. Applicability of two different lanthanide-based label technologies, upconverting nanoparticles and switchable lanthanide luminescence, to protein detection was explored. Moreover, the potential of recombinant antibodies and aptamers as alternative affinity binders were evaluated. Additionally, alternative conjugation chemistries for production of the labeled binders were studied. Different assay concepts were also evaluated with respect to their applicability to point-of-care testing, which requires simple yet sensitive methods. The applicability of upconverting nanoparticles to the simultaneous quantitative measurement of multiple analytes using imaging-based detection was demonstrated. Additionally, the required instrumentation was relatively simple and inexpensive compared to other luminescent lanthanide-based labels requiring time-resolved measurement. The developed homogeneous assays exploiting switchable lanthanide luminescence were rapid and simple to perform and thus applicable even to point-ofcare testing. The sensitivities of the homogeneous assays were in the picomolar range, which are still inadequate for some analytes, such as cardiac troponins, requiring ultralow limits of detection. For most analytes, however, the obtained limits of detection were sufficient. The use of recombinant antibody fragments and aptamers as binders allowed site-specific and controlled covalent conjugation to construct labeled binders reproducibly either by using chemical modification or recombinant technology. Luminescent lanthanide labels were shown to be widely applicable for protein detection in various assay setups and to contribute assay sensitivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the work presented in this study was to demonstrate the wide applicability of a single-label quenching resonance energy transfer (QRET) assay based on time-resolved lanthanide luminescence. QRET technology is proximity dependent method utilizing weak and unspecific interaction between soluble quencher molecule and lanthanide chelate. The interaction between quencher and chelate is lost when the ligand binds to its target molecule. The properties of QRET technology are especially useful in high throughput screening (HTS) assays. At the beginning of this study, only end-point type QRET technology was available. To enable efficient study of enzymatic reactions, the QRET technology was further developed to enable measurement of reaction kinetics. This was performed using proteindeoxyribonuclei acid (DNA) interaction as a first tool to monitor reaction kinetics. Later, the QRET was used to study nucleotide exchange reaction kinetics and mutation induced effects to the small GTPase activity. Small GTPases act as a molecular switch shifting between active GTP bound and inactive GDP bound conformation. The possibility of monitoring reaction kinetics using the QRET technology was evaluated using two homogeneous assays: a direct growth factor detection assay and a nucleotide exchange monitoring assay with small GTPases. To complete the list, a heterogeneous assay for monitoring GTP hydrolysis using small GTPases, was developed. All these small GTPase assays could be performed using nanomolar protein concentrations without GTPase pretreatment. The results from these studies demonstrated that QRET technology can be used to monitor reaction kinetics and further enable the possibility to use the same method for screening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two time-resolved EPR techniques, have been used to study the light induced electron transfer(ET) in Type I photosynthetic reaction centers(RCs). First, pulsed EPR was used to compare PsaA-M688H and PsaB-M668H mutants of Chlamydomonas reinhardtii and Synechosystis sp. PCC 6803.The out-of-phase echo modulation curves combined with other EPR and optical data show that the effect of the mutations is species dependent. Second, transient and pulsed EPR data are presented which show that PsaA-A660N and PsaB-A640N mutations in C. reinhardtii alter the relative quantum yield of ET in the A- and B-branches of PS I. Third, transient EPR studies on RCs from Heliobacillus mobilis that have been exposed to oxygen show partial inhibition of ET. In the RCs in which ET still occurs, the ET kinetics and EPR spectra show evidence of oxidation of some but not all of the, BChl g and BChl g' to Chl a.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nous investiguons dans ce travail la dynamique des excitons dans une couche mince d’agrégats H autoassemblés hélicoïdaux de molécules de sexithiophène. Le couplage intermoléculaire (J=100 meV) place ce matériau dans la catégorie des semi-conducteurs à couplage de type intermédiaire. Le désordre énergétique et la forte interaction électronsphonons causent une forte localisation des excitons. Les espèces initiales se ramifient en deux états distincts : un état d’excitons autopiégés (rendement de 95 %) et un état à transfert de charge (rendement de 5%). À température de la pièce (293K), les processus de sauts intermoléculaires sont activés et l’anisotropie de la fluorescence décroît rapidement à zéro en 5 ns. À basse température (14K), les processus de sauts sont gelés. Pour caractériser la dynamique de diffusion des espèces, une expérience d’anisotropie de fluorescence a été effectuée. Celle-ci consiste à mesurer la différence entre la photoluminescence polarisée parallèlement au laser excitateur et celle polarisée perpendiculairement, en fonction du temps. Cette mesure nous donne de l’information sur la dépolarisation des excitons, qui est directement reliée à leur diffusion dans la structure supramoléculaire. On mesure une anisotropie de 0,1 après 20 ns qui perdure jusqu’à 50ns. Les états à transfert de charge causent une remontée de l’anisotropie vers une valeur de 0,15 sur une plage temporelle allant de 50 ns jusqu’à 210 ns (période entre les impulsions laser). Ces résultats démontrent que la localisation des porteurs est très grande à 14K, et qu’elle est supérieure pour les espèces à transfert de charge. Un modèle numérique simple d’équations différentielles à temps de vie radiatif et de dépolarisation constants permet de reproduire les données expérimentales. Ce modèle a toutefois ses limitations, notamment en ce qui a trait aux mécanismes de dépolarisation des excitons.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les siliciures métalliques constituent un élément crucial des contacts électriques des transistors que l'on retrouve au coeur des circuits intégrés modernes. À mesure qu'on réduit les dimensions de ces derniers apparaissent de graves problèmes de formation, liés par exemple à la limitation des processus par la faible densité de sites de germination. L'objectif de ce projet est d'étudier les mécanismes de synthèse de siliciures métalliques à très petite échelle, en particulier le NiSi, et de déterminer l’effet de l’endommagement du Si par implantation ionique sur la séquence de phase. Nous avons déterminé la séquence de formation des différentes phases du système Ni-Si d’échantillons possédant une couche de Si amorphe sur lesquels étaient déposés 10 nm de Ni. Celle-ci a été obtenue à partir de mesures de diffraction des rayons X résolue en temps et, pour des échantillons trempés à des températures critiques du processus, l’identité des phases et la composition et la microstructure ont été déterminées par mesures de figures de pôle, spectrométrie par rétrodiffusion Rutherford et microscopie électronique en transmission (TEM). Nous avons constaté que pour environ la moitié des échantillons, une réaction survenait spontanément avant le début du recuit thermique, le produit de la réaction étant du Ni2Si hexagonal, une phase instable à température de la pièce, mélangée à du NiSi. Dans de tels échantillons, la température de formation du NiSi, la phase d’intérêt pour la microélectronique, était significativement abaissée.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’étude du cerveau humain est un domaine en plein essor et les techniques non-invasives de l’étudier sont très prometteuses. Afin de l’étudier de manière non-invasive, notre laboratoire utilise principalement l’imagerie par résonance magnétique fonctionnelle (IRMf) et l’imagerie optique diffuse (IOD) continue pour mesurer et localiser l’activité cérébrale induite par une tâche visuelle, cognitive ou motrice. Le signal de ces deux techniques repose, entre autres, sur les concentrations d’hémoglobine cérébrale à cause du couplage qui existe entre l’activité neuronale et le flux sanguin local dans le cerveau. Pour être en mesure de comparer les deux signaux (et éventuellement calibrer le signal d’IRMf par l’IOD), où chaque signal est relatif à son propre niveau de base physiologique inconnu, une nouvelle technique ayant la capacité de mesurer le niveau de base physiologique est nécessaire. Cette nouvelle technique est l’IOD résolue temporellement qui permet d’estimer les concentrations d’hémoglobine cérébrale. Ce nouveau système permet donc de quantifier le niveau de base physiologique en termes de concentrations d’hémoglobine cérébrale absolue. L’objectif général de ma maîtrise était de développer un tel système afin de l’utiliser dans une large étude portant sur la condition cardiovasculaire, le vieillissement, la neuroimagerie ainsi que les performances cognitives. Il a fallu tout d’abord construire le système, le caractériser puis valider les résultats avant de pouvoir l’utiliser sur les sujets de recherche. La validation s’est premièrement réalisée sur des fantômes homogènes ainsi qu’hétérogènes (deux couches) qui ont été développés. La validation des concentrations d’hémoglobine cérébrale a été réalisée via une tâche cognitive et appuyée par les tests sanguins des sujets de recherche. Finalement, on présente les résultats obtenus dans une large étude employant le système d’IOD résolue temporellement en se concentrant sur les différences reliées au vieillissement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal.