950 resultados para tecnologías digitales CAD-CAM-CAE


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In machining of internal threads, dedicated tools, known as taps, are needed for each profile type, diameter, and low cutting speed values are used when compared to main machining processes. This restriction in the cutting speed is associated with the difficulty of synchronizing the tool s rotation speed and feed velocity in the process. This fact restricts the flexibility and makes machining lead times longer when manufacturing of components with threads is required. An alternative to the constraints imposed by the tap is the thread milling with helical interpolation technique. The technique is the fusion of two movements: rotation and helical interpolation. The tools may have different configurations: a single edge or multiple edges (axial, radial or both). However, thread milling with helical interpolation technique is relatively new and there are limited studies on the subject, a fact which promotes challenges to its wide application in the manufacturing shop floor. The objective of this research is determine the performance of different types of tools in the thread milling with helical interpolation technique using hardened steel workpieces. In this sense, four tool configurations were used for threading milling in AISI 4340 quenched and tempered steel (40 HRC). The results showed that climb cut promoted a greater number of machined threads, regardless of tool configuration. The upcut milling causes chippings in cutting edge, while the climb cutting promotes abrasive wear. Another important point is that increase in hole diameter by tool diameter ratio increases tool lifetime

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare the misfit vertical, horizontal and passivity of zirconia and cobalt-chromium frameworks fabricated for CAD / CAM technology and conventional method of casting. Sixteen frameworks in one-piece, were obtained from a metallic matrix containing three Brånemark compatible implants with regular platform (Titamax Cortical Ti, Neodent). Eight frameworks were fabricated by CAD / CAM system (NeoShape, Neodent): four in zirconia (ZirCAD) and four cobalt-chromium (CoCrcad). Eight other frameworks were obtained by conventional casting method: four cobalt-chromium with UCLA abutment premachined Co-Cr (CoCrUCci) and four cobalt-chromium with UCLA abutment castable (CoCrUCc). The fit vertical, horizontal and passivity by one-screw test were measured using scanning electron microscopy with magnification of 250x. Initially evaluated the passivity by one-screw test and subsequently to assess the vertical and horizontal misfit, tightened all the screws with a torque of 20 Ncm. Mean, standard deviation, minimum and maximum values were calculated for each group. Measurements of horizontal misfit were transformed into cumulative frequency for categorization of the variable and the group later comparison groups. To evaluate the existence of quantitative differences between the groups tested for vertical misfit and passivity, we used the Kruskal-Wallis test. The Mann-Whitney test was used to compare group to group statistical differences (p <0.05). Were observed the respective mean and standard deviation for vertical misfit and passivity in micrometers: ZirCAD (5.9 ± 3.6, 107.2 ± 36), CoCrcad (1.2 ± 2.2, 107.5 ± 26 ), CoCrUCci (11.8 ± 9.8, 124.7 ± 74), CoCrUCc (12.9 ± 11.0, 108.8 ± 85). There were statistical differences in measures of vertical misfit (p = 0.000). The Mann-Whitney test revealed statistical differences (p <0.05) between all groups except between CoCrUCci and CoCrUCc (p = 0.619). No statistical difference was observed for the passivity. In relation to the horizontal misfit groups ZirCAD and CoCrcad did not show best values in relation to CoCrUCci and CoCrUCc. Based on the results it can be concluded that frameworks fabricated by CAD / CAM technology had better values of vertical fit than those manufactured by the casting method, nevertheless, the passivity was not influenced by manufacturing technique and material used. The horizontal fit obtained by frameworks manufactured by CAD / CAM was not superior to those manufactured by casting. A lower variability in vertical adjustment and passivity was observed when frameworks were fabricated by CAD / CAM technology

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dental ceramics are presented within a simplifying framework allowing for facile understanding of their development, composition and indications. Engineering assessments of clinical function are dealt with and literature is reviewed on the clinical behaviour of all-ceramic systems. Practical aspects are presented regarding the choice and use of dental ceramics to maximize aesthetics and durability, emphasizing what we know and how we know it.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An accurate estimate of machining time is very important for predicting delivery time, manufacturing costs, and also to help production process planning. Most commercial CAM software systems estimate the machining time in milling operations simply by dividing the entire tool path length by the programmed feed rate. This time estimate differs drastically from the real process time because the feed rate is not always constant due to machine and computer numerical controlled (CNC) limitations. This study presents a practical mechanistic method for milling time estimation when machining free-form geometries. The method considers a variable called machine response time (MRT) which characterizes the real CNC machine's capacity to move in high feed rates in free-form geometries. MRT is a global performance feature which can be obtained for any type of CNC machine configuration by carrying out a simple test. For validating the methodology, a workpiece was used to generate NC programs for five different types of CNC machines. A practical industrial case study was also carried out to validate the method. The results indicated that MRT, and consequently, the real machining time, depends on the CNC machine's potential: furthermore, the greater MRT, the larger the difference between predicted milling time and real milling time. The proposed method achieved an error range from 0.3% to 12% of the real machining time, whereas the CAM estimation achieved from 211% to 1244% error. The MRT-based process is also suggested as an instrument for helping in machine tool benchmarking.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to examine the effect of different acid etching times on the surface roughness and flexural strength of a lithium disilicate-based glass ceramic. Ceramic bar-shaped specimens (16 mm x 2 mm x 2 mm) were produced from ceramic blocks. All specimens were polished and sonically cleaned in distilled water. Specimens were randomly divided into 5 groups (n=15). Group A (control) no treatment. Groups B-E were etched with 4.9% hydrofluoric acid (HF) for 4 different etching periods: 20 s, 60 s, 90 s and 180 s, respectively. Etched surfaces were observed under scanning electron microscopy. Surface profilometry was used to examine the roughness of the etched ceramic surfaces, and the specimens were loaded to failure using a 3-point bending test to determine the flexural strength. Data were analyzed using one-way ANOVA and Tukey's test (α=0.05). All etching periods produced significantly rougher surfaces than the control group (p<0.05). Roughness values increased with the increase of the etching time. The mean flexural strength values were (MPa): A=417 ± 55; B=367 ± 68; C=363 ± 84; D=329 ± 70; and E=314 ± 62. HF etching significantly reduced the mean flexural strength as the etching time increased (p=0.003). In conclusion, the findings of this study showed that the increase of HF etching time affected the surface roughness and the flexural strength of a lithium disilicate-based glass ceramic, confirming the study hypothesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Patients with congenital malformations, traumatic or pathological mutilation and maxillofacial developmental disorders can be restored aesthetically and emotionally by the production and use of facial prostheses. The aim of this study was to review the literature about the retention and processing methods of facial prostheses, and discuss their characteristics. A literature review on Medline (PubMed) database was performed by using the keywords maxillofacial prosthesis, silicone, resin, pigment, cosmetic, prosthetic nose, based on articles published from 1956 to 2010. Several methods of retention, from adhesives to the placement of implants, and different processing methods such as laser, CAD/CAM and rapid prototyping technologies have been reported. There are advantages and disadvantages of each procedure, and none can be classified as better compared to others.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of 2 different surface polishing procedures - glazing (GZ) and manual polishing (MP) - on the roughness of ceramics processed by computer-aided design/computer-aided manufacturing (CAD/CAM) and conventional systems (stratification technique). Eighty ceramic discs (diameter: 8 mm, thickness: 1 mm) were prepared and divided among 8 groups (n = 10) according to the type of ceramic disc and polishing method: 4 GZ and 4 MP. Specimens were glazed according to each manufacturer's recommendations. Two silicone polishing points were used on the ceramic surface for manual polishing. Roughness was measured using a surface roughness tester. The roughness measurements were made along a distance of 2 mm on the sample surface and the speed of reading was 0.1 mm/s. Three measurements were taken for each sample. The data (μm) were statistically analyzed using analysis of variance (ANOVA) and Tukey's test (α = 0.05). Qualitative analysis was performed using scanning electron microscopy (SEM). The mean (± SD) roughness values obtained for GZ were: 1.1 ± 0.40 μm; 1.0 ± 0.31 μm; 1.6 ± 0.31 μm; and 2.2 ± 0.73 μm. For MP, the mean values were: 0.66 ± 0.13 μm; 0.43 ± 0.14 μm; 1.6 ± 0.55 μm; and 2.0 ± 0.63 μm. The mean roughness values were significantly affected by the ceramic type (P = 0.0001) and polishing technique (P = 0.0047). The SEM images confirmed the roughness data. The manually polished glass CAD/CAM ceramics promoted lower surface roughness than did the glazed feldspathic dental ceramics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To investigate the influence of the convergence angle of tooth preparation on the fracture load of Y-TZP-based ceramic (YZ-Vita YZ) substructure (SB) veneered with a feldspathic porcelain (VM9-Vita VM9). Methods: Finite element stress analysis (FEA) was performed to examine the stress distribution of the system. Eighty YZ SB were fabricated using a CAD-CAM system and divided into four groups (n = 20), according to the total occlusal convergence (TOC) angle: G6-6° TOC; G12-12° TOC; G20-20° TOC; and G20MOD-20° TOC with modified SB. All SB were veneered with VM9, cemented in a fiber reinforced epoxy resin die, and loaded to failure. Half of the specimens from each group (n = 10) were cyclic fatigued (106 cycles) before testing. Failure analysis was performed to determine the fracture origin. Data were statistically analyzed using Anova and Tukey's tests (α = 0.05). Results: The greatest mean load to fracture value was found for the G20MOD, which was predicted by the FEA. Cyclic fatigue did not significantly affect the load of fracture. Catastrophic failure originating from the internal occlusal surface of the SB was the predominant failure mode, except for G20MOD. Significance: The YZ-VM9 restorations resisted greater compression load than the usual physiological occlusal load, regardless of the TOC angle of preparations. Yet, the G20MOD design produced the best performance among the experimental conditions evaluated. © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Incluye bibliografía

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Incluye bibliografía

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Incluye bibliografía

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Incluye bibliografía