325 resultados para sonda
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Enfermagem - FMB
Resumo:
Pós-graduação em Enfermagem (mestrado profissional) - FMB
Resumo:
Pós-graduação em Anestesiologia - FMB
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
Pós-graduação em Química - IQ
Resumo:
This work was developed from the study by Araujo, R.A.N. et al. Stability regions around the components of the triple system 2001 SN263. (Monthly Notices Of The Royal Astronomical Society, 2012, v. 423(4), 3058-3073 p.) where it was studied the stable and unstable regions system (2001 SN263), which is a triple asteroid system, and these are celestial orbiting our sun. Being close to the Earth is characterized as NEA (Near-Earth Asteroids), asteroids and which periodically approach the Earth's orbit, given that there is great interest in the study and exploitation of these objects, it is the key can carry features that contribute to better understand the process of formation of our solar system. Study the dynamics of bodies that govern those systems proves to be greatly attractive because of the mutual gravitational perturbation of bodies and also by external disturbances. Recently, NEA 2001 SN263 was chosen as a target of Aster mission where a probe is sent for this triple system, appearing therefore the need for obtaining information for characterizing stable regions internal and external to the system, with respect to the effects of radiation pressure. First, this study demonstrated that the integrator used showed satisfactory results of the orbital evolution of bodies in accordance with previous studies and also the characterization of stable and unstable regions brought similar results to the study by Araujo et al. (2012). From these results it was possible to carry out the implementation of the radiation pressure in the system in 2001 SN263, in a region close to the central body, where the simulations were carried out, which brought as a result that the regions before being characterized as stable in unstable true for small particles size from 1 to 5 micrometers. So the next orbital region to the central body and the ... ( Complete abstract click electronic access below)
Resumo:
In this paper, we will present an overview of the smart grid defining the three main systems that compose it: smart infrastructure system, smart management system and smart protection system. We will conceptualize a functionality of smart management system, the conservative voltage reduction, citing its benefits and its history of application. And, finally, we'll cover a test in which we reduce the nominal voltages on incandescent bulbs, CFL and LED, in the context of residential lighting, and on LED and HPS, in the context of public lighting. The test aims to check whether the voltage reduction adversely affects sources of lighting by measuring the temperature manually with a thermal imaging camera FLIR and illuminance with a LUX meter. The set of power factor, total harmonic distortion, and input power values will be collected automatically through the power quality Analyzer Fluke 345 with a probe Fluke Hall Effect Current. For residential lighting, it was found that both CFL and LED had good performance with the smallest variations in illuminance. Between both, the LED source had the lowest harmonics and the lowest power consumption, on the other hand incandescent bulbs had a bad performance as expected. Public light sources also had a good performance and obtained power factors within the standards, as opposed to the CFL and LED residential sources. The data collected clearly shows the feasibility for nominal voltage reductions. Even with small reductions, there are possibilities of savings which can be passed on to the utilities and consumers
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work was developed from the study by Araujo, R.A.N. et al. Stability regions around the components of the triple system 2001 SN263. (Monthly Notices Of The Royal Astronomical Society, 2012, v. 423(4), 3058-3073 p.) where it was studied the stable and unstable regions system (2001 SN263), which is a triple asteroid system, and these are celestial orbiting our sun. Being close to the Earth is characterized as NEA (Near-Earth Asteroids), asteroids and which periodically approach the Earth's orbit, given that there is great interest in the study and exploitation of these objects, it is the key can carry features that contribute to better understand the process of formation of our solar system. Study the dynamics of bodies that govern those systems proves to be greatly attractive because of the mutual gravitational perturbation of bodies and also by external disturbances. Recently, NEA 2001 SN263 was chosen as a target of Aster mission where a probe is sent for this triple system, appearing therefore the need for obtaining information for characterizing stable regions internal and external to the system, with respect to the effects of radiation pressure. First, this study demonstrated that the integrator used showed satisfactory results of the orbital evolution of bodies in accordance with previous studies and also the characterization of stable and unstable regions brought similar results to the study by Araujo et al. (2012). From these results it was possible to carry out the implementation of the radiation pressure in the system in 2001 SN263, in a region close to the central body, where the simulations were carried out, which brought as a result that the regions before being characterized as stable in unstable true for small particles size from 1 to 5 micrometers. So the next orbital region to the central body and the ... ( Complete abstract click electronic access below)
Resumo:
In this paper, we will present an overview of the smart grid defining the three main systems that compose it: smart infrastructure system, smart management system and smart protection system. We will conceptualize a functionality of smart management system, the conservative voltage reduction, citing its benefits and its history of application. And, finally, we'll cover a test in which we reduce the nominal voltages on incandescent bulbs, CFL and LED, in the context of residential lighting, and on LED and HPS, in the context of public lighting. The test aims to check whether the voltage reduction adversely affects sources of lighting by measuring the temperature manually with a thermal imaging camera FLIR and illuminance with a LUX meter. The set of power factor, total harmonic distortion, and input power values will be collected automatically through the power quality Analyzer Fluke 345 with a probe Fluke Hall Effect Current. For residential lighting, it was found that both CFL and LED had good performance with the smallest variations in illuminance. Between both, the LED source had the lowest harmonics and the lowest power consumption, on the other hand incandescent bulbs had a bad performance as expected. Public light sources also had a good performance and obtained power factors within the standards, as opposed to the CFL and LED residential sources. The data collected clearly shows the feasibility for nominal voltage reductions. Even with small reductions, there are possibilities of savings which can be passed on to the utilities and consumers
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
O objetivo deste estudo foi avaliar o crescimento microbiano em sondas para vitrectomia de uso único, reprocessadas na prática assistencial. Foram investigadas nove sondas reusadas e reprocessadas por diferentes métodos. As sondas foram segmentadas, individualmente, em porções de 3,5 cm, totalizando em 979 unidades amostrais (extensões, conectores e ponteiras) inoculadas em meio de cultura e incubadas a 37ºC, por 14 dias. Os resultados mostraram crescimento microbiano em 57 (5,8%) unidades amostrais, das quais, 25 foram esterilizadas por Óxido de Etileno, 16 por Plasma de Peróxido de Hidrogênio e 16 por Vapor à Baixa Temperatura e Formaldeído. Foram identificadas 17 espécies microbianas, sendo as mais prevalentes o Micrococcus spp., Staphylococcus coagulase negativa, Pseudomonas spp. e Bacillus subtilis. O reuso de sondas de uso único para vitrectomia não se mostrou seguro, portanto tal prática não é recomendada.