914 resultados para solder joints


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The folded plate girder, a newly proposed bridge girder, is investigated through this thesis. The folded plate girder is cold bent out of a single sheet of steel. The cold bending eliminates the costly and inconsistent shop welds found in traditional girders. The folded plate girder is meant for application in short span bridges. The girder was subjected to an equivalent 75 year lifetime loading to investigate the fatigue performance. The rebar detail used in the closure region between adjacent slabs has been investigated in the past by the NCHRP 12-68 project. This thesis will proposes a hooked rebar detail as a cost effective alternative to the previously recommended headed rebar detail. The proposed hooked rebar detail looks to improve upon the headed bar detail by increasing the clear cover, and reducing the cost of fabrication and shipment of the rebar. Six specimens containing closure regions are subjected to both positive and negative moment loading in order to investigate their behavior and failure modes under ultimate load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To assess several baseline risk factors that may predict patellofemoral and tibiofemoral cartilage loss during a 6-month period. Methods For 177 subjects with chronic knee pain, 3T magnetic resonance imaging (MRI) of both knees was performed at baseline and followup. Knees were semiquantitatively assessed, evaluating cartilage morphology, subchondral bone marrow lesions, meniscal morphology/extrusion, synovitis, and effusion. Age, sex, and body mass index (BMI), bone marrow lesions, meniscal damage/extrusion, synovitis, effusion, and prevalent cartilage damage in the same subregion were evaluated as possible risk factors for cartilage loss. Logistic regression models were applied to predict cartilage loss. Models were adjusted for age, sex, treatment, and BMI. Results Seventy-nine subregions (1.6%) showed incident or worsening cartilage damage at followup. None of the demographic risk factors was predictive of future cartilage loss. Predictors of patellofemoral cartilage loss were effusion, with an adjusted odds ratio (OR) of 3.5 (95% confidence interval [95% CI] 1.39.4), and prevalent cartilage damage in the same subregion with an adjusted OR of 4.3 (95% CI 1.314.1). Risk factors for tibiofemoral cartilage loss were baseline meniscal extrusion (adjusted OR 3.6 [95% CI 1.310.1]), prevalent bone marrow lesions (adjusted OR 4.7 [95% CI 1.119.5]), and prevalent cartilage damage (adjusted OR 15.3 [95% CI 4.947.4]). Conclusion Cartilage loss over 6 months is rare, but may be detected semiquantitatively by 3T MRI and is most commonly observed in knees with Kellgren/Lawrence grade 3. Predictors of patellofemoral cartilage loss were effusion and prevalent cartilage damage in the same subregion. Predictors of tibiofemoral cartilage loss were prevalent cartilage damage, bone marrow lesions, and meniscal extrusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate extracellular matrix components in articular cartilage, ligaments and synovia in an experimental model of diabetes. Young Wistar rats were divided into a streptozotocin-induced (STZ; 35 mg/kg) diabetic group (DG; n=15) and a control group (CG; n=15). Weight, blood glucose and plasma anti-carboxymethyllysine were measured 70 days after STZ infusions. Knee joints, patellar ligaments, and lateral and medial collateral ligaments were isolated and stained with hematoxylineosin and Picrosirius. The total collagen content was determined by morphometry. Immunofluorescence was employed to evaluate types I, III, and V collagen in ligaments and synovial tissues and types II and XI collagen in cartilage. Results: Higher blood glucose levels and plasma anti-carboxymethyllysine were observed in DG rats when compared to those in CG rats. The final weight was significantly lower in the DG rats than in the CG rats. Histomorphometric evaluation depicted a small quantity of collagen fibers in ligaments and articular cartilage in DG rats, as well as increased collagen in synovial tissue. There was a decrease in cartilage proteoglycans in DG rats when compared with CG rats. Immunofluorescence staining revealed an increase of collagen III and V in ligaments, collagen XI in cartilage, and collagen I in synovial tissue of DG rats compared with CG rats. Conclusion: The ligaments, cartilage and synovia are highly affected following STZ-induced diabetes in rats, due the remodeling of collagen types in these tissues. This process may promote the degradation of the extracellular matrix, thus compromising joint function. Our data may help to better understand the pathogenesis of joint involvement related to diabetes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

3D video-fluoroscopy is an accurate but cumbersome technique to estimate natural or prosthetic human joint kinematics. This dissertation proposes innovative methodologies to improve the 3D fluoroscopic analysis reliability and usability. Being based on direct radiographic imaging of the joint, and avoiding soft tissue artefact that limits the accuracy of skin marker based techniques, the fluoroscopic analysis has a potential accuracy of the order of mm/deg or better. It can provide fundamental informations for clinical and methodological applications, but, notwithstanding the number of methodological protocols proposed in the literature, time consuming user interaction is exploited to obtain consistent results. The user-dependency prevented a reliable quantification of the actual accuracy and precision of the methods, and, consequently, slowed down the translation to the clinical practice. The objective of the present work was to speed up this process introducing methodological improvements in the analysis. In the thesis, the fluoroscopic analysis was characterized in depth, in order to evaluate its pros and cons, and to provide reliable solutions to overcome its limitations. To this aim, an analytical approach was followed. The major sources of error were isolated with in-silico preliminary studies as: (a) geometric distortion and calibration errors, (b) 2D images and 3D models resolutions, (c) incorrect contour extraction, (d) bone model symmetries, (e) optimization algorithm limitations, (f) user errors. The effect of each criticality was quantified, and verified with an in-vivo preliminary study on the elbow joint. The dominant source of error was identified in the limited extent of the convergence domain for the local optimization algorithms, which forced the user to manually specify the starting pose for the estimating process. To solve this problem, two different approaches were followed: to increase the optimal pose convergence basin, the local approach used sequential alignments of the 6 degrees of freedom in order of sensitivity, or a geometrical feature-based estimation of the initial conditions for the optimization; the global approach used an unsupervised memetic algorithm to optimally explore the search domain. The performances of the technique were evaluated with a series of in-silico studies and validated in-vitro with a phantom based comparison with a radiostereometric gold-standard. The accuracy of the method is joint-dependent, and for the intact knee joint, the new unsupervised algorithm guaranteed a maximum error lower than 0.5 mm for in-plane translations, 10 mm for out-of-plane translation, and of 3 deg for rotations in a mono-planar setup; and lower than 0.5 mm for translations and 1 deg for rotations in a bi-planar setups. The bi-planar setup is best suited when accurate results are needed, such as for methodological research studies. The mono-planar analysis may be enough for clinical application when the analysis time and cost may be an issue. A further reduction of the user interaction was obtained for prosthetic joints kinematics. A mixed region-growing and level-set segmentation method was proposed and halved the analysis time, delegating the computational burden to the machine. In-silico and in-vivo studies demonstrated that the reliability of the new semiautomatic method was comparable to a user defined manual gold-standard. The improved fluoroscopic analysis was finally applied to a first in-vivo methodological study on the foot kinematics. Preliminary evaluations showed that the presented methodology represents a feasible gold-standard for the validation of skin marker based foot kinematics protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dynamics of a passive back-to-back test rig have been characterised, leading to a multi-coordinate approach for the analysis of arbitrary test configurations. Universal joints have been introduced into a typical pre-loaded back-to-back system in order to produce an oscillating torsional moment in a test specimen. Two different arrangements have been investigated using a frequency-based sub-structuring approach: the receptance method. A numerical model has been developed in accordance with this theory, allowing interconnection of systems with two-coordinates and closed multi-loop schemes. The model calculates the receptance functions and modal and deflected shapes of a general system. Closed form expressions of the following individual elements have been developed: a servomotor, damped continuous shaft and a universal joint. Numerical results for specific cases have been compared with published data in literature and experimental measurements undertaken in the present work. Due to the complexity of the universal joint and its oscillating dynamic effects, a more detailed analysis of this component has been developed. Two models have been presented. The first represents the joint as two inertias connected by a massless cross-piece. The second, derived by the dynamic analysis of a spherical four-link mechanism, considers the contribution of the floating element and its gyroscopic effects. An investigation into non-linear behaviour has led to a time domain model that utilises the Runge-Kutta fourth order method for resolution of the dynamic equations. It has been demonstrated that the torsional receptances of a universal joint, derived using the simple model, result in representation of the joint as an equivalent variable inertia. In order to verify the model, a test rig has been built and experimental validation undertaken. The variable inertia of a universal joint has lead to a novel application of the component as a passive device for the balancing of inertia variations in slider-crank mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract The aim of this work was the development of a murine model of septic arthrosynovitis and osteomyelitis caused by Staphylococcus aureus, which could mimic the natural disease occurring in humans and which could be suitable for testing preventive and therapeutic interventions. This model could be particularly useful since S. aureus-mediated joints and bones infections are relevant in humans, both in terms of frequency and severity. Our attention focused in tracking bacterial infiltration in joints and bones over time using different microbiological and hystopathological tools, which allowed us to have a complete overview of the situation and to evaluate the immunological actions undertaken by the host to contain or eradicate the bacterial infection. Antibodies and cytokines profiles, as well as recruitment of host immune cells at joints of immunized and infected mice were therefore monitored for a time period that allowed us to study both the acute and the chronic phases of the disease in situ. Finally the Novartis vaccine formulation proposed against S. aureus infections was tested for its capacity to protect immunized mice from joints infections, and the preventive immunization was compared to a standard antibiotic prophylaxis. The availability of powerful tools to study specific bacterial-mediated diseases is nowadays an important requirement for the scientific community to shed light on the complex interactions between host and pathogens and to test treatments for preventing or contrasting infections. We believe that our work significantly contributes to the overall knowledge in the field of S. aureus-dependent pathologies, opening the possibility for further investigations in several fields of study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work of this thesis is on the implementation of a variable stiffness joint antagonistically actuated by a couple of twisted-string actuator (TSA). This type of joint is possible to be applied in the field of robotics, like UB Hand IV (the anthropomorphic robotic hand developed by University of Bologna). The purposes of the activities are to build the joint dynamic model and simultaneously control the position and stiffness. Three different control approaches (Feedback linearization, PID, PID+Feedforward) are proposed and validated in simulation. To improve the properties of joint stiffness, a joint with elastic element is taken into account and discussed. To the end, the experimental setup that has been developed for the experimental validation of the proposed control approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research on adhesive joints is arousing increasing interest in aerospace industry. Incomplete knowledge of fatigue in adhesively bonded joints is a major obstacle to their application. The prediction of the disbonding growth is yet an open question. This thesis researches the influence of the adhesive thickness on fatigue disbond growth. Experimental testing on specimens with different thickness has been performed. Both a conventional approach based on the strain energy release rate and an approach based on cyclic strain energy are provided. The inadequacy of the former approach is discussed. Outcomes from tests support the idea of correlating the crack growth rate to the cyclic strain energy. In order to push further the study, a 2D finite element model for the prediction of disbond growth under quasi-static loading has been developed and implemented in Abaqus. Numerical simulations have been conducted with different values of the adhesive thickness. The results from tests and simulations are in accordance with each other. According to them, no dependence of disbonding on the adhesive thickness has been evidenced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the feasibility of delayed gadolinium-enhanced magnetic resonance (MR) imaging of the cartilage of metacarpophalangeal (MCP) joints in patients with rheumatoid arthritis (RA) compared with that in control subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nerve blocks and radiofrequency neurotomy of the nerves supplying the cervical zygapophyseal joints are validated tools for diagnosis and treatment of chronic neck pain, respectively. Unlike fluoroscopy, ultrasound may allow visualization of the target nerves, thereby potentially improving diagnostic accuracy and therapeutic efficacy of the procedures. The aims of this exploratory study were to determine the ultrasound visibility of the target nerves in chronic neck pain patients and to describe the variability of their course in relation to the fluoroscopically used bony landmarks.