993 resultados para sequential methods
Resumo:
Anemia screening before blood donation requires an accurate, quick, practical, and easy method with minimal discomfort for the donors. The aim of this study was to compare the accuracy of two quantitative methods of anemia screening: the HemoCue 201(+) (Aktiebolaget Leo Diagnostics) hemoglobin (Hb) and microhematocrit (micro-Hct) tests. Two blood samples of a single fingerstick were obtained from 969 unselected potential female donors to determine the Hb by HemoCue 201(+) and micro-Hct using HemataSTAT II (Separation Technology, Inc.), in alternating order. From each participant, a venous blood sample was drawn and run in an automatic hematology analyzer (ABX Pentra 60, ABX Diagnostics). Considering results of ABX Pentra 60 as true values, the sensitivity and specificity of HemoCue 201(+) and micro-Hct as screening methods were compared, using a venous Hb level of 12.0 g per dL as cutoff for anemia. The sensitivities of the HemoCue 201(+) and HemataSTAT II in detecting anemia were 56 percent (95% confidence interval [CI], 46.1%-65.5%) and 39.5 percent (95% CI, 30.2%-49.3%), respectively (p < 0.001). Analyzing only candidates with a venous Hb level lower than 11.0 g per dL, the deferral rate was 100 percent by HemoCue 201(+) and 77 percent by HemataSTAT II. The specificities of the methods were 93.5 and 93.2 percent, respectively. The HemoCue 201(+) showed greater discriminating power for detecting anemia in prospective blood donors than the micro-Hct method. Both presented equivalent deferral error rates of nonanemic potential donors. Compared to the micro-Hct, HemoCue 201(+) reduces the risk of anemic female donors giving blood, specially for those with lower Hb levels, without increasing the deferral of nonanemic potential donors.
Resumo:
This special issue represents a further exploration of some issues raised at a symposium entitled “Functional magnetic resonance imaging: From methods to madness” presented during the 15th annual Theoretical and Experimental Neuropsychology (TENNET XV) meeting in Montreal, Canada in June, 2004. The special issue’s theme is methods and learning in functional magnetic resonance imaging (fMRI), and it comprises 6 articles (3 reviews and 3 empirical studies). The first (Amaro and Barker) provides a beginners guide to fMRI and the BOLD effect (perhaps an alternative title might have been “fMRI for dummies”). While fMRI is now commonplace, there are still researchers who have yet to employ it as an experimental method and need some basic questions answered before they venture into new territory. This article should serve them well. A key issue of interest at the symposium was how fMRI could be used to elucidate cerebral mechanisms responsible for new learning. The next 4 articles address this directly, with the first (Little and Thulborn) an overview of data from fMRI studies of category-learning, and the second from the same laboratory (Little, Shin, Siscol, and Thulborn) an empirical investigation of changes in brain activity occurring across different stages of learning. While a role for medial temporal lobe (MTL) structures in episodic memory encoding has been acknowledged for some time, the different experimental tasks and stimuli employed across neuroimaging studies have not surprisingly produced conflicting data in terms of the precise subregion(s) involved. The next paper (Parsons, Haut, Lemieux, Moran, and Leach) addresses this by examining effects of stimulus modality during verbal memory encoding. Typically, BOLD fMRI studies of learning are conducted over short time scales, however, the fourth paper in this series (Olson, Rao, Moore, Wang, Detre, and Aguirre) describes an empirical investigation of learning occurring over a longer than usual period, achieving this by employing a relatively novel technique called perfusion fMRI. This technique shows considerable promise for future studies. The final article in this special issue (de Zubicaray) represents a departure from the more familiar cognitive neuroscience applications of fMRI, instead describing how neuroimaging studies might be conducted to both inform and constrain information processing models of cognition.
Resumo:
Purpose: Many methods exist in the literature for identifying PEEP to set in ARDS patients following a lung recruitment maneuver (RM). We compared ten published parameters for setting PEEP following a RM. Methods: Lung injury was induced by bilateral lung lavage in 14 female Dorset sheep, yielding a PaO(2) 100-150 mmHg at F(I)O(2) 1.0 and PEEP 5 cmH(2)O. A quasi-static P-V curve was then performed using the supersyringe method; PEEP was set to 20 cmH(2)O and a RM performed with pressure control ventilation (inspiratory pressure set to 40-50 cmH(2)O), until PaO(2) + PaCO(2) > 400 mmHg. Following the RM, a decremental PEEP trial was performed. The PEEP was decreased in 1 cmH(2)O steps every 5 min until 15 cmH(2)O was reached. Parameters measured during the decremental PEEP trial were compared with parameters obtained from the P-V curve. Results: For setting PEEP, maximum dynamic tidal respiratory compliance, maximum PaO(2), maximum PaO(2) + PaCO(2), and minimum shunt calculated during the decremental PEEP trial, and the lower Pflex and point of maximal compliance increase on the inflation limb of the P-V curve (Pmci,i) were statistically indistinguishable. The PEEP value obtained using the deflation upper Pflex and the point of maximal compliance decrease on the deflation limb were significantly higher, and the true inflection point on the inflation limb and minimum PaCO(2) were significantly lower than the other variables. Conclusion: In this animal model of ARDS, dynamic tidal respiratory compliance, maximum PaO(2), maximum PaO(2) + PaCO(2), minimum shunt, inflation lower Pflex and Pmci,i yield similar values for PEEP following a recruitment maneuver.
Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64
Resumo:
Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective ""CORE-64"" trial (""Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors""). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows.
Resumo:
OBJECTIVE. Coronary MDCT angiography has been shown to be an accurate noninvasive tool for the diagnosis of obstructive coronary artery disease (CAD). Its sensitivity and negative predictive value for diagnosing percentage of stenosis are unsurpassed compared with those of other noninvasive testing methods. However, in its current form, it provides no information regarding the physiologic impact of CAD and is a poor predictor of myocardial ischemia. CORE320 is a multicenter multinational diagnostic study with the primary objective to evaluate the diagnostic accuracy of 320-MDCT for detecting coronary artery luminal stenosis and corresponding myocardial perfusion deficits in patients with suspected CAD compared with the reference standard of conventional coronary angiography and SPECT myocardial perfusion imaging. CONCLUSION. We aim to describe the CT acquisition, reconstruction, and analysis methods of the CORE320 study.
Resumo:
Minimal perfect hash functions are used for memory efficient storage and fast retrieval of items from static sets. We present an infinite family of efficient and practical algorithms for generating order preserving minimal perfect hash functions. We show that almost all members of the family construct space and time optimal order preserving minimal perfect hash functions, and we identify the one with minimum constants. Members of the family generate a hash function in two steps. First a special kind of function into an r-graph is computed probabilistically. Then this function is refined deterministically to a minimal perfect hash function. We give strong theoretical evidence that the first step uses linear random time. The second step runs in linear deterministic time. The family not only has theoretical importance, but also offers the fastest known method for generating perfect hash functions.
Resumo:
Little consensus exists in the literature regarding methods for determination of the onset of electromyographic (EMG) activity. The aim of this study was to compare the relative accuracy of a range of computer-based techniques with respect to EMG onset determined visually by an experienced examiner. Twenty-seven methods were compared which varied in terms of EMG processing (low pass filtering at 10, 50 and 500 Hz), threshold value (1, 2 and 3 SD beyond mean of baseline activity) and the number of samples for which the mean must exceed the defined threshold (20, 50 and 100 ms). Three hundred randomly selected trials of a postural task were evaluated using each technique. The visual determination of EMG onset was found to be highly repeatable between days. Linear regression equations were calculated for the values selected by each computer method which indicated that the onset values selected by the majority of the parameter combinations deviated significantly from the visually derived onset values. Several methods accurately selected the time of onset of EMG activity and are recommended for future use. Copyright (C) 1996 Elsevier Science Ireland Ltd.
Resumo:
This study investigated the effect of two anti-pronation taping techniques on vertical navicular height, an indicator of foot pronation, after its application and 20 min of exercise. The taping techniques were: the low dye (LD) and low dye with the addition of calcaneal slings and reverse sixes (LDCR). A repeated measures study was used. It found that LDCR was superior to LD and control immediately after application and exercise. LD was better than control immediately after application but not after exercise. These findings provide practical directions to clinicians regularly using anti-pronation taping techniques.
Resumo:
The effects of 4 estrus synchronization treatments on intervals to and synchrony of estrus and ovulation, on timing of the preovulatory LH surge and associated changes in plasma progesterone, LH, FSH, and 17 beta-estradiol (E(2)) were investigated in 48 Bos indicus cows. Treatment 1 consisted of 2 injections of PGF(2 alpha) 14 d apart (n = 12); Treatment 2 of a subcutaneous 3-mg norgestomet implant and an intramuscular injection of 3 mg of norgestomet and 5 mg estradiol valerate, with the implant removed 10 d later (n = 12; norgestomet-estradiol); Treatment 3 of norgestomet-estradiol, with a subcutaneous injection of PMSG given at time of implant removal (Day 10; n = 12); and Treatment 4 of norgestomet implant (as for Treatments 2 and 3) inserted for 10 d, with an intramuscular injection of PGF(2 alpha) given at the time of implant removal (n = 12). The experiment was conducted in 2 replicates (24 cows/replicate, 6 cows/group). Estrus, ovulation and timing of the preovulatory surge of LH varied less in cows treated with norgestomet-estradiol and PMSG than in cows in Treatments 1 and 4 (P < 0.008). Treatment with PMSG;educed variation in ovulation times and timing of the LH surge in cows treated with norgestomet-estradiol (P < 0.02). Concentrations of E(2) were higher in cows in Treatments 2 and 3 on the final day of treatment and at about 6 h post ovulation compared with cows in Treatments 1 and 4 (P < 0.05). Different methods for synchronizing estrus did not alter sequential endocrine and behavioral changes in relation to the timing of the LH peak, and the results were consistent with current recommendations for insemination times in Bos taurus cattle. (C) 1997 by Elsevier Science Inc.
Resumo:
Here, we examine morphological changes in cortical thickness of patients with Alzheimer`s disease (AD) using image analysis algorithms for brain structure segmentation and study automatic classification of AD patients using cortical and volumetric data. Cortical thickness of AD patients (n = 14) was measured using MRI cortical surface-based analysis and compared with healthy subjects (n = 20). Data was analyzed using an automated algorithm for tissue segmentation and classification. A Support Vector Machine (SVM) was applied over the volumetric measurements of subcortical and cortical structures to separate AD patients from controls. The group analysis showed cortical thickness reduction in the superior temporal lobe, parahippocampal gyrus, and enthorhinal cortex in both hemispheres. We also found cortical thinning in the isthmus of cingulate gyrus and middle temporal gyrus at the right hemisphere, as well as a reduction of the cortical mantle in areas previously shown to be associated with AD. We also confirmed that automatic classification algorithms (SVM) could be helpful to distinguish AD patients from healthy controls. Moreover, the same areas implicated in the pathogenesis of AD were the main parameters driving the classification algorithm. While the patient sample used in this study was relatively small, we expect that using a database of regional volumes derived from MRI scans of a large number of subjects will increase the SVM power of AD patient identification.
Resumo:
Objectives-This study adopted a concurrent task design and aimed to quantify the efficiency and smoothness of voluntary movement in Tourette's syndrome via the use of a graphics tablet which permits analysis of movement profiles. In particular, the aim was to ascertain whether a concurrent task (digit span) would affect the kinematics of goal directed movements, and whether patients with Tourette's syndrome would exhibit abnormal functional asymmetries compared with their matched controls. Methods-Twelve patients with Tourette's syndrome and their matched controls performed 12 vertical zig zag movements, with both left and right hands (with and without the concurrent task), to large or small targets over long or short extents. Results-With short strokes, controls showed the predicted right hand superiority in movement time more strongly than patients with Tourette's syndrome, who instead showed greater hand symmetry with short strokes. The right hand of controls was less force efficient with long strokes and more force efficient with short strokes, whereas either hand of patients with Tourette's syndrome was equally force efficient, irrespective of stroke length, with an overall performance profile similar to but better than that of the controls' left hand. The concurrent task, however, increased the force efficiency of the right hand in patients with Tourette's syndrome and the left hand in controls. Conclusions-Patients with Tourette's syndrome, compared with controls, were not impaired in the performance of fast, goal directed movements such as aiming at targets; they performed in certain respects better than controls. The findings clearly add to the growing literature on anomalous lateralisation in Tourette's syndrome, which may be explained by the recently reported loss of normal basal ganglia asymmetries in that disorder.
Resumo:
Background: Organ shortage impairs the proposition of multivisceral transplantation to treat multiple organ failure. Interspecies (xeno) transplantation is a valid solution for organ shortage; however, suitable models of this advance are lacking. We describe an effective model of multivisceral xenotransplantation to study hyperacute rejection. Methods: Under general anesthesia, we in block recovered the distal esophagus, stomach, small bowel, colon, liver, pancreas, spleen, and kidneys from donors and implanted heterotopically in the lower abdomen of recipients. Animals were divided into four groups: I-canine donor, swine recipient (n = 6); II - swine donor, canine recipient (n = 5); III-canine donor, canine recipient (n = 4); and IV-swine donor, swine recipient (n = 5). Groups I and 11 comprised experimental (xenotransplantation) and III and IV control groups (allotransplantation). During the experiment, we appraised recipient evolution and graft modification by sequential biopsy up to 3 h. At this time, we killed animals for autopsy (experimental end point). Results: We accomplished all experiments successfully. Every grafts attained customary appearance and convenient urine output immediately after unclamp. Around 15 min after reperfusion, xenografts achieved signs of progressive hyperacute rejection and absence of urine output. At the end of experiments we observed moderate to severe hyperacute rejection at small bowel, colon, mesenteric lymph node, liver, spleen, pancreas, and kidney, while stomach and esophagus achieved mild lesions. In contrast, allograft achieved normal or minimum ischemia/reperfusion injury and constant urine output. Conclusion: The present procedure assembles a simple and effective model to study multivisceral xenotransplantation and may ultimately spread researches toward hyperacute rejection.
Resumo:
Purpose: To assess the radiological findings of urogenital tuberculosis (UGT) in patients at different disease stages, for a better understanding of its pathophysiology. Patients and methods: We retrospectively reviewed the radiological exams of 20 men (median age 41 years; range: 28-65) with urogenital tuberculosis diagnosis. The patients were classified in the following groups: (1) bilateral renal tuberculosis with predominantly parenchymatous involvement; (2) unilateral renal tuberculosis; (3) unilateral renal tuberculosis with bladder tuberculosis and (4) bilateral renal tuberculosis with bladder tuberculosis. Results: One AIDS patient had multiple bilateral renal tuberculosis abscesses (group 1). Six patients had unilateral renal tuberculosis with hydronephrosis due to stenosis and thickening of the collecting system, without involvement of the bladder or contralateral kidney (group 2). Six patients had bladder tuberculosis with diffuse thickening of the bladder wall, with one very low or no function kidney while the other kidney was normal (group 3). Seven patients had bladder tuberculosis associated to a very low or no function kidney with the other kidney with high-grade vesicoureteral reflux-associated ureterohydronephrosis (group 4). In two patients, sequential exams showed evolution of tuberculosis from a unilateral renal and ureteral lesion to contracted bladder and dilatation of the contralateral kidney secondary to high-grade reflux. Conclusions: UGT may have variable radiological presentations. However, in two of our cases we have seen that tuberculosis involvement of the urinary tract may be sequential. Further evidences are necessary to confirm this hypothesis. (C) 2009 Elsevier Ireland Ltd. All rights reserved.