816 resultados para point of sale communication


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Through the use of rhetoric centered on authority and risk avoidance, scientific method has co-opted knowledge, especially women's everyday and experiential knowledge in the domestic sphere. This, in turn, has produced a profound affect on technical communication in the present day. I am drawing on rhetorical theory to study cookbooks and recipes for their contributions to changes in instructional texts. Using the rhetorical lenses of metis (cunning intelligence), kairos (timing and fitness) and mneme (memory), I examine the way in which recipes and cookbooks are constructed, used and perceived. This helps me uncover lost voices in history, the voices of women who used recipes, produced cookbooks and changed the way instructions read. Beginning with the earliest cookbooks and recipes, but focusing on the pivotal temporal interval of 1870-1935, I investigate the writing and rhetorical forces shaping instruction sets and domestic discourse. By the time of scientific cooking and domestic science, everyday and experiential knowledge were being excluded to make room for scientific method and the industrial values of the public sphere. In this study, I also assess how the public sphere, via Cooperative Extension Services and other government agencies, impacted the domestic sphere, further devaluing everyday knowledge in favor of the public scientific model. I will show how the changes in the production of food, cookbooks and recipes were related to changes in technical communication. These changes had wide rippling effects on the field of technical communication. By returning to some of the tenets and traditions of everyday and experiential knowledge, technical communication scholars, practitioners and instructors today can find new ways to encounter technical communication, specifically regarding the creation of instructional texts. Bringing cookbooks, recipes and everyday knowledge into the classroom and the field engenders a new realm of epistemological possibilities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aprotinin is widely used in cardiac surgery to reduce postoperative bleeding and the need for blood transfusion. Controversy exists regarding the influence of aprotinin on renal function and its effect on the incidence of perioperative myocardial infarction (MI) and cerebrovascular incidents (CVI). In the present study, we analyzed the incidence of these adverse events in patients who underwent coronary artery bypass grafting (CABG) surgery under full-dose aprotinin and compared the data with those recently reported by Mangano et al [2006]. For 751 consecutive patients undergoing CABG surgery under full-dose aprotinin (>4 million kalikrein-inhibitor units) we analyzed in-hospital data on renal dysfunction or failure, MI (defined as creatine kinase-myocardial band > 60 iU/L), and CVI (defined as persistent or transient neurological symptoms and/or positive computed tomographic scan). Average age was 67.0 +/- 9.9 years, and patient pre- and perioperative characteristics were similar to those in the Society of Thoracic Surgeons database. The mortality (2.8%) and incidence of renal failure (5.2%) ranged within the reported results. The incidence rates of MI (8% versus 16%; P < .01) and CVI (2% versus 6%; P < .01) however, were significantly lower than those reported by Mangano et al. Thus the data of our single center experience do not confirm the recently reported negative effect of full-dose aprotinin on the incidence of MI and CVI. Therefore, aprotinin may still remain a valid option to reduce postoperative bleeding, especially because of the increased use of aggressive fibrinolytic therapy following percutaneous transluminal coronary angioplasty.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Bleeding is a frequent complication during surgery. The intraoperative administration of blood products, including packed red blood cells, platelets and fresh frozen plasma (FFP), is often live saving. Complications of blood transfusions contribute considerably to perioperative costs and blood product resources are limited. Consequently, strategies to optimize the decision to transfuse are needed. Bleeding during surgery is a dynamic process and may result in major blood loss and coagulopathy due to dilution and consumption. The indication for transfusion should be based on reliable coagulation studies. While hemoglobin levels and platelet counts are available within 15 minutes, standard coagulation studies require one hour. Therefore, the decision to administer FFP has to be made in the absence of any data. Point of care testing of prothrombin time ensures that one major parameter of coagulation is available in the operation theatre within minutes. It is fast, easy to perform, inexpensive and may enable physicians to rationally determine the need for FFP. METHODS/DESIGN: The objective of the POC-OP trial is to determine the effectiveness of point of care prothrombin time testing to reduce the administration of FFP. It is a patient and assessor blind, single center randomized controlled parallel group trial in 220 patients aged between 18 and 90 years undergoing major surgery (any type, except cardiac surgery and liver transplantation) with an estimated blood loss during surgery exceeding 20% of the calculated total blood volume or a requirement of FFP according to the judgment of the physicians in charge. Patients are randomized to usual care plus point of care prothrombin time testing or usual care alone without point of care testing. The primary outcome is the relative risk to receive any FFP perioperatively. The inclusion of 110 patients per group will yield more than 80% power to detect a clinically relevant relative risk of 0.60 to receive FFP of the experimental as compared with the control group. DISCUSSION: Point of care prothrombin time testing in the operation theatre may reduce the administration of FFP considerably, which in turn may decrease costs and complications usually associated with the administration of blood products. TRIAL REGISTRATION: NCT00656396.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is no accepted way of measuring prothrombin time without time loss for patients undergoing major surgery who are at risk of intraoperative dilution and consumption coagulopathy due to bleeding and volume replacement with crystalloids or colloids. Decisions to transfuse fresh frozen plasma and procoagulatory drugs have to rely on clinical judgment in these situations. Point-of-care devices are considerably faster than the standard laboratory methods. In this study we assessed the accuracy of a Point-of-care (PoC) device measuring prothrombin time compared to the standard laboratory method. Patients undergoing major surgery and intensive care unit patients were included. PoC prothrombin time was measured by CoaguChek XS Plus (Roche Diagnostics, Switzerland). PoC and reference tests were performed independently and interpreted under blinded conditions. Using a cut-off prothrombin time of 50%, we calculated diagnostic accuracy measures, plotted a receiver operating characteristic (ROC) curve and tested for equivalence between the two methods. PoC sensitivity and specificity were 95% (95% CI 77%, 100%) and 95% (95% CI 91%, 98%) respectively. The negative likelihood ratio was 0.05 (95% CI 0.01, 0.32). The positive likelihood ratio was 19.57 (95% CI 10.62, 36.06). The area under the ROC curve was 0.988. Equivalence between the two methods was confirmed. CoaguChek XS Plus is a rapid and highly accurate test compared with the reference test. These findings suggest that PoC testing will be useful for monitoring intraoperative prothrombin time when coagulopathy is suspected. It could lead to a more rational use of expensive and limited blood bank resources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Monitoring of HIV viral load in patients on combination antiretroviral therapy (ART) is not generally available in resource-limited settings. We examined the cost-effectiveness of qualitative point-of-care viral load tests (POC-VL) in sub-Saharan Africa. DESIGN Mathematical model based on longitudinal data from the Gugulethu and Khayelitsha township ART programmes in Cape Town, South Africa. METHODS Cohorts of patients on ART monitored by POC-VL, CD4 cell count or clinically were simulated. Scenario A considered the more accurate detection of treatment failure with POC-VL only, and scenario B also considered the effect on HIV transmission. Scenario C further assumed that the risk of virologic failure is halved with POC-VL due to improved adherence. We estimated the change in costs per quality-adjusted life-year gained (incremental cost-effectiveness ratios, ICERs) of POC-VL compared with CD4 and clinical monitoring. RESULTS POC-VL tests with detection limits less than 1000 copies/ml increased costs due to unnecessary switches to second-line ART, without improving survival. Assuming POC-VL unit costs between US$5 and US$20 and detection limits between 1000 and 10,000 copies/ml, the ICER of POC-VL was US$4010-US$9230 compared with clinical and US$5960-US$25540 compared with CD4 cell count monitoring. In Scenario B, the corresponding ICERs were US$2450-US$5830 and US$2230-US$10380. In Scenario C, the ICER ranged between US$960 and US$2500 compared with clinical monitoring and between cost-saving and US$2460 compared with CD4 monitoring. CONCLUSION The cost-effectiveness of POC-VL for monitoring ART is improved by a higher detection limit, by taking the reduction in new HIV infections into account and assuming that failure of first-line ART is reduced due to targeted adherence counselling.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using a chain of urns, we build a Bayesian nonparametric alarm system to predict catastrophic events, such as epidemics, black outs, etc. Differently from other alarm systems in the literature, our model is constantly updated on the basis of the available information, according to the Bayesian paradigm. The papers contains both theoretical and empirical results. In particular, we test our alarm system on a well-known time series of sunspots.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Check-up is a frequent motivation for patients to see their general practitioner. The challenge lies in the choice of screening tools to accomplish an efficient, individual and age-adapted approach. In this article we review evidence-based screening methods, whose efficacy has been demonstrated by randomized clinical trials, as well as their application in clinical practice. While cardiovascular check-up has a high grade of evidence for nearly all patients, counselling to lifestyle change except for smoking cessation has been proved with lower evidence. In contrast, relatively new is the fact that ultrasound to screen for an abdominal aortic aneurysm is useful among men smokers or past smokers between 65 and 75 years old.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. A nonrecognized pneumothorax (PTX) may become a life-threatening tension PTX. A reliable point-of-care diagnostic tool could help in reduce this risk. For this purpose, we investigated the feasibility of the use of the PneumoScan, an innovative device based on micropower impulse radar (MIR). Patients and Methods. addition to a standard diagnostic protocol including clinical examination, chest X-ray (CXR), and computed tomography (CT), 24 consecutive patients with chest trauma underwent PneumoScan testing in the shock trauma room to exclude a PTX. Results. The application of the PneumoScan was simple, quick, and reliable without functional disorder. Clinical examination and CXR each revealed one and PneumoScan three out of altogether four PTXs (sensitivity 75%, specificity 100%, positive predictive value 100%, and negative predictive value 95%). The undetected PTX did not require intervention. Conclusion. The PneumoScan as a point-of-care device offers additional diagnostic value in patient management following chest trauma. Further studies with more patients have to be performed to evaluate the diagnostic accuracy of the device.