964 resultados para pacs: television systems for office automation


Relevância:

50.00% 50.00%

Publicador:

Resumo:

This report summarizes the current state of the art in cooperative vehicle-highway automation systems in Europe and Asia based on a series of meetings, demonstrations, and site visits, combined with the results of literature review. This review covers systems that provide drivers with a range of automation capabilities, from driver assistance to fully automated driving, with an emphasis on cooperative systems that involve active exchanges of information between the vehicles and the roadside and among separate vehicles. The trends in development and deployment of these systems are examined by country, and the similarities and differences relative to the U.S. situation are noted, leading toward recommendations for future U.S. action. The Literature Review on Recent International Activity in Cooperative Vehicle-Highway Automation Systems is published separately as FHWA-HRT-13-025.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This literature review supports the report, Recent International Activity in Cooperative Vehicle-Highway Automation Systems. It reviews the published literature in English dating from 2007 or later about non-U.S.-based work on cooperative vehicle-highway automation systems. This review covers work performed in Europe and Japan, with application to transit buses, heavy trucks, and passenger cars. In addition to fully automated driving of the vehicles (without human intervention), it also covers partial automation systems, which automate subsets of the total driving process. Recent International Activity in Cooperative Vehicle Highway Automation Systems is published separately as FHWA-HRT-12-033.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Many factors affect the airflow patterns, thermal comfort, contaminant removal efficiency and indoor air quality at individual workstations in office buildings. In this study, four ventilation systems were used in a test chamber designed to represent an area of a typical office building floor and reproduce the real characteristics of a modern office space. Measurements of particle concentration and thermal parameters (temperature and velocity) were carried out for each of the following types of ventilation systems: a) conventional air distribution system with ceiling supply and return; b) conventional air distribution system with ceiling supply and return near the floor; c) underfloor air distribution system; and d) split system. The measurements aimed to analyse the particle removal efficiency in the breathing zone and the impact of particle concentration on an individual at the workstation. The efficiency of the ventilation system was analysed by measuring particle size and concentration, ventilation effectiveness and the Indoor/Outdoor ratio. Each ventilation system showed different airflow patterns and the efficiency of each ventilation system in the removal of the particles in the breathing zone showed no correlation with particle size and the various methods of analyses used.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This thesis has developed a new approach to trace virtual protection signals in Electrical substation networks. The main goal of the research was to analyse the contents of the virtual signals transferred, using third party software. In doing so, a comprehensive test was done on a distance protection relay, using non-conventional test equipment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Abstract Legacy information systems evolved incrementally in response to changes in business strategy and information technology. Organizations are now being forced to change much more radically and quickly than previously and this change places new demands on information systems. Legacy information systems are usually considered from a technical perspective, addressing issues such as age, complexity, maintainability, design and technology. We wish to demonstrate that the business dimension to legacy information systems, represented by the organisation structure, business processes and procedures that are bound up in the design and operation of the existing IT systems, is also significant. This paper identifies the important role of legacy information systems in the formation of new strategies. We show that the move away from a stable to an unstable business environment accelerates the rate of change. Furthermore, the gap between what the legacy information systems can deliver and the strategic vision of the organization widens when the legacy information systems are unable to adapt to meet the new requirements. An analysis of fifteen case studies provides evidence that legacy information systems include business and technical dimensions and that the systems can present problems when there is a misalignment between the strategic vision of the business, the IT legacy and the old business model embodied in the legacy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A high contrast ratio between windows and surrounding walls may lead to office workers visual discomfort that could negatively affect their satisfaction and productivity. Consequently, occupants may try to adapt their working environment by closing blinds and/ or turning on the lights to enhance indoor visual comfort, which can reduce predicted energy savings. The hypothesis of this study is that reducing luminance contrast ratio on the window wall will improve window appearance which potentially will reduce visual discomfort and decrease workers interventions. Thus, this PhD research proposes a simple strategy to diminish the luminance contrast on the window wall by increasing the luminance of the areas surrounding the windows using supplementary light emitting diode (LED) systems. To test the hypothesis, this investigation will involve three experiments in different office layouts with various window types and orientations in Brisbane, Australia. It will assess user preferences for different luminance patterns in windowed offices featuring flexible, lowpower LED lighting installations that allows multiple lighting design options on the window wall. Detailed luminance and illuminance measures will be used to match quantitative lighting design assessment to user preferences.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper proposes a pragmatic framework that has been developed for classifying and analyzing developments in distributed automation and information systems - especially those that have been labeled intelligent systems for different reasons. The framework dissects the different stages in the standard feedback process and assesses distribution in terms of the level of granularity of the organization that is being considered. The framework has been found to be useful in comparing and assessing different distributed industrial control paradigms and also for examining common features of different development projects - especially those that might be sourced from different sectors or domains. © 2012 IFAC.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This chapter proposes a simple and pragmatic framework that has been developed for classifying and analyzing developments in distributed automation and information systems - especially those that have been labelled intelligent systems for different reasons. The framework dissects the different stages in the standard feedback process and assesses distribution in terms of the level of granularity of the organization that is being considered. The framework has been found to be useful in comparing and assessing different distributed industrial control paradigms and also for examining common features of different development projects - especially those that might be sourced from different sectors or domains. © Springer-Verlag Berlin Heidelberg 2013.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Smart technology involves the integration of a variety of home systems including lighting, climate control, security etc. to enhance the comfort, convenience and economy of the home for its users. It is currently unknown if homebuyers believe that these systems add value to the home. This study used the market value of home sales and an attitudinal survey of homebuyers, to determine the increased value of homes containing smart technology. The results demonstrated that a significant price premium was paid for the incorporation of the technology into new homes. In addition, the research suggests that the use of this technology is not limited to high-income earners or other demographic stereotypes. Instead it has broad market appeal and the potential to save energy for the community at large.<br />

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Despite the great benefits that it can potentially contribute to modern workplace environment, raised floor system (RFS) encountered many barriers in the process of its applications for the fitout of office buildings in the Australian construction industry. Through a set of comprehensive research activities, the significant influence factors (SIFs) and problems associated with the RFS fitout implementation are identified. Further discussion of these SIFs and problems unearths a range of project level critical factors (PLCFs) pertaining to the RFS fitout design, construction, operation and maintenance, which presents firsthand checklists for the project team to review in the project delivery process. These factors need to be accommodated appropriately in order to enhance the implementation of the RFS fitout in Australian office buildings. Following a constructability study, a framework was developed by integrating these SIFs and PLCFs into the delivery of the RFS fitout in an aim to enhance the project constructability and minimize problems in the RFS service performance.<br />

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To comparatively and prospectively compare in a randomized clinical trial, dentin hypersensitivity after treatment with three in-office bleaching systems, based on hydrogen peroxide at different concentrations, with and without light source activation. Methods: 88 individuals were included according to inclusion and exclusion criteria. Subjects were randomly divided into the following three treatment groups: Group 1 was treated with three 15-minute applications of hydrogen peroxide at 15% with titanium dioxide (Lase Peroxide Lite) that was light-activated (Light Plus Whitening Lase) with five cycles of 1 minute and 30 seconds each cycle, giving a total treatment time of 45 minutes; Group 2 was treated with three 10-minute applications of hydrogen peroxide at 35% (Lase Peroxide Sensy), activated by light (LPWL) same activation cycles than Group 1, with a total treatment time of 30 minutes; Group 3 was treated with only one application for 45 minutes of hydrogen peroxide at 35% (Whitegold Office) without light activation. Each subject underwent one session of bleaching on the anterior teeth according to the manufacturers' instructions. Dentin sensitivity was recorded with a visual analogue scale (VAS) at baseline, immediately after, and at 7 and 30 days after treatment using a stimulus of an evaporative blowing triple syringe for 3 seconds on the upper central incisors from a distance of 1 cm. A Kruskal-Wallis test followed by Mann-Whitney test was performed for statistical analysis. Results: All groups showed increased sensitivity immediately after treatment. Group 1 displayed less changes relative to baseline with no significant differences (P= 0.104). At 7 and 30 days after treatment, a comparison of VAS values indicated no significant differences between all groups (P= 0.598 and 0.489, respectively).