962 resultados para limit of quantitation


Relevância:

90.00% 90.00%

Publicador:

Resumo:

A biomimetic sensor for norfloxacin is presented that is based on host-guest interactions and potentiometric transduction. The artificial host was imprinted into polymers made from methacrylic acid and/or 2-vinyl pyridine. The resulting particles were entrapped in a plasticized poly(vinyl chloride) (PVC) matrix. The sensors exhibit near-Nernstian response in steady state evaluations, and detection limits range from 0.40 to 1.0 μg mL−1, respectively, and are independent of pH values at between 2 and 6, and 8 and 11, respectively. Good selectivity was observed over several potential interferents. In flowing media, the sensors exhibit fast response, a sensitivity of 68.2 mV per decade, a linear range from 79 μM to 2.5 mM, a detection limit of 20 μg mL−1, and a stable baseline. The sensors were successfully applied to field monitoring of norfloxacin in fish samples, biological samples, and pharmaceutical products.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Twenty-four whole blood and serum samples were drawn from an eight year-old heart transplant child during a 36 months follow-up. EBV serology was positive for VCA-IgM and IgG, and negative for EBNA-IgG at the age of five years old when the child presented with signs and symptoms suggestive of acute infectious mononucleosis. After 14 months, serological parameters were: positive VCA-IgG, EBNA-IgG and negative VCA-IgM. This serological pattern has been maintained since then even during episodes suggestive of EBV reactivation. PCR amplified a specific DNA fragment from the EBV gp220 (detection limit of 100 viral copies). All twenty-four whole blood samples yielded positive results by PCR, while 12 out of 24 serum samples were positive. We aimed at analyzing whether detection of EBV-DNA in serum samples by PCR was associated with overt disease as stated by the need of antiviral treatment and hospitalization. Statistical analysis showed agreement between the two parameters evidenced by the Kappa test (value 0.750; p < 0.001). We concluded that detection of EBV-DNA in serum samples of immunosuppressed patients might be used as a laboratory marker of active EBV disease when a Real-Time PCR or another quantitative method is not available.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A gold nanoparticle-coated screen-printed carbon electrode was used as the transducer in the development of an electrochemical immunosensor for Ara h 1 (a major peanut allergen) detection in food samples. Gold nanoparticles (average diameter=32 nm) were electrochemically generated on the surface of screen-printed carbon electrodes. Two monoclonal antibodies were used in a sandwich-type immunoassay and the antibody–antigen interaction was electrochemically detected through stripping analysis of enzymatically (using alkaline phosphatase) deposited silver. The total time of the optimized immunoassay was 3 h 50 min. The developed immunosensor allowed the quantification of Ara h 1 between 12.6 and 2000 ng/ml, with a limit of detection of 3.8 ng/ml, and provided precise (RSD <8.7%) and accurate (recovery >96.6%) results. The immunosensor was successfully applied to the analysis of complex food matrices (cookies and chocolate), being able to detect Ara h 1 in samples containing 0.1% of peanut.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Potentiometric detection with homemade polymeric membrane microelectrodes was coupled to a magnetic sandwich immunoassay for Salmonella typhimurium determination. Cadmium and sodium ion selective electrodes were used respectively as indicator and pseudo-reference electrodes and were prepared in pipette tips to allow potentiometric measurements in microliter sample volumes. In the proposed method, the concentration of S. typhimurium was proportional to the amount of cadmium released upon dissolution of a CdS nanoparticle labeled to the secondary detection antibody. The limit of detection was 2 cells per 100 μL. The immunomagnetic assay with potentiometric detection is suitable for sensitive and rapid (average total time per assay of 75 minutes) detection of S. typhimurium in milk samples. The proposed method is easy to perform, safe, sensitive, and low cost and has potential for in situ analysis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Due to the importance and wide applications of the DNA analysis, there is a need to make genetic analysis more available and more affordable. As such, the aim of this PhD thesis is to optimize a colorimetric DNA biosensor based on gold nanoprobes developed in CEMOP by reducing its price and the needed volume of solution without compromising the device sensitivity and reliability, towards the point of care use. Firstly, the price of the biosensor was decreased by replacing the silicon photodetector by a low cost, solution processed TiO2 photodetector. To further reduce the photodetector price, a novel fabrication method was developed: a cost-effective inkjet printing technology that enabled to increase TiO2 surface area. Secondly, the DNA biosensor was optimized by means of microfluidics that offer advantages of miniaturization, much lower sample/reagents consumption, enhanced system performance and functionality by integrating different components. In the developed microfluidic platform, the optical path length was extended by detecting along the channel and the light was transmitted by optical fibres enabling to guide the light very close to the analysed solution. Microfluidic chip of high aspect ratio (~13), smooth and nearly vertical sidewalls was fabricated in PDMS using a SU-8 mould for patterning. The platform coupled to the gold nanoprobe assay enabled detection of Mycobacterium tuberculosis using 3 8l on DNA solution, i.e. 20 times less than in the previous state-of-the-art. Subsequently, the bio-microfluidic platform was optimized in terms of cost, electrical signal processing and sensitivity to colour variation, yielding 160% improvement of colorimetric AuNPs analysis. Planar microlenses were incorporated to converge light into the sample and then to the output fibre core increasing 6 times the signal-to-losses ratio. The optimized platform enabled detection of single nucleotide polymorphism related with obesity risk (FTO) using target DNA concentration below the limit of detection of the conventionally used microplate reader (i.e. 15 ng/μl) with 10 times lower solution volume (3 μl). The combination of the unique optical properties of gold nanoprobes with microfluidic platform resulted in sensitive and accurate sensor for single nucleotide polymorphism detection operating using small volumes of solutions and without the need for substrate functionalization or sophisticated instrumentation. Simultaneously, to enable on chip reagents mixing, a PDMS micromixer was developed and optimized for the highest efficiency, low pressure drop and short mixing length. The optimized device shows 80% of mixing efficiency at Re = 0.1 in 2.5 mm long mixer with the pressure drop of 6 Pa, satisfying requirements for the application in the microfluidic platform for DNA analysis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The interest in chromium (Cr) arises from the widespread use of this heavy metal in various industrial processes that cause its release as liquid, solid and gaseous waste into the environment. The impact of Cr on the environment and living organisms primarily depends on its chemical form, since Cr(III) is an essential micronutrient for humans, other animals and plants, and Cr(VI) is highly toxic and a known human carcinogen. This study aimed to evaluate if the electrodialytic process (ED) is an appropriate treatment for Cr removal, through a critical overview of Cr speciation, before and after the ED experiments, to assess possible Cr(III)-Cr(VI) interconversions during the treatment. ED was the treatment technique applied to two types of matrices containing Cr: chromate copper arsenate (CCA) contaminated soil and municipal solid waste incineration (MSWI) fly ash. In order to study Cr remediation, three EDR set-ups were used: a new set-up, the combined cell (2/3C or 3/2C), with three compartments, alternating current between two anodes and different initial experimental conditions, one set-up with three compartments (3C cell) and the other set-up with two compartments (2C cell). The Cr removal rates obtained in this study were between 10-36% for the soil, and 1-13% for the fly ash. The highest Cr removal rates were achieved in the 26 days experiments: 36% for the soil, 13% for the fly ash. Regarding the 13 days experiments, the highest Cr removal rates were attained with the 2/3C set-up: 24% for the soil, 5% for the fly ash. The analysis of Cr(VI) was performed before and after ED experiments to evaluate eventual changes in Cr speciation during the treatment. This analysis was conducted by two methods: USEPA Method 3060A, for the extraction of Cr(VI); and Hach Company Method 8023, for the detection of Cr(VI). Despite the differences in Cr total concentration, both matrices presented a similar speciation, with Cr(III) being the main species found and Cr(VI) less than 3% of Cr total, before and after the treatment. For fly ash, Cr(VI) was initially below the detection limit of the method and remained that way after the treatment. For soil, Cr(VI) decreased after the treatment. Oxidation of Cr(III) to Cr(VI) did not occur during the ED process since there was no increase in Cr(VI) in the matrices after the treatment. Hence, the results of this study indicate that ED is an appropriate technique to remediate matrices containing Cr because it contributes to Cr removal, without causing Cr(III)-Cr(VI) interconversions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The production of a Z boson in association with a J/ψ meson in proton--proton collisions probes the production mechanisms of quarkonium and heavy flavour in association with vector bosons, and allows studies of multiple parton scattering. Using 20.3fb−1 of data collected with the ATLAS experiment at the LHC, in pp collisions at s√=8 TeV, the first measurement of associated Z+J/ψ production is presented for both prompt and non-prompt J/ψ production, with both signatures having a significance in excess of 5σ. The inclusive production cross-sections for Z boson production (in μ+μ− or e+e− decay modes) in association with prompt and non-prompt J/ψ(→μ+μ−) are measured relative to the inclusive production rate of Z bosons in the same fiducial volume to be (88±16±6)×10−8 and (157±22±10)×10−8 respectively. Normalised differential production cross-sections are also determined as a function of the J/ψ transverse momentum. The fraction of signal events arising from single and double parton scattering is estimated, and a lower limit of 5.3 (3.7)mb at 68 (95) confidence level is placed on the effective cross-section regulating double parton interactions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To develop a simplified questionnaire for self-evaluation by adolescents of foods associated with the risk of coronary diseases. METHODS: Frequency questionnaires about 80 foods were answered by representative samples of 256 adolescents aged 12 to 19 from Rio de Janeiro as part of the Nutrition and Health Research project. The dependent variable was the serum cholesterol predicting equation as influenced by diet, and the independent variables were the foods. The variables were normalized and, using Pearson's correlation coefficient, those with r>0.10 were selected for the regression model. The model was analyzed for sex, age, random sample, and total calories. Those food products that explained 85% of the cholesterol variation equation were present in the caloric model, and contained trans fatty acids were selected for the questionnaire. RESULTS: Sixty-five food products had a statistically significant correlation (P<0.001) with the dependent variable. The simplified questionnaire included 9 food products present in all tested models: steak or broiled meat, hamburger, full-fat cheese, French fries or potato chips, whole milk, pies or cakes, cookies, sausages, butter or margarine. The limit of the added food points for self-evaluation was 100, and over 120 points was considered excessive. CONCLUSION: The scores given to the food products and the criteria for the evaluation of the consumption limits enabled the adolescents to get to know and to balance their intake.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An algebraic decay rate is derived which bounds the time required for velocities to equilibrate in a spatially homogeneous flow-through model representing the continuum limit of a gas of particles interacting through slightly inelastic collisions. This rate is obtained by reformulating the dynamical problem as the gradient flow of a convex energy on an infinite-dimensional manifold. An abstract theory is developed for gradient flows in length spaces, which shows how degenerate convexity (or even non-convexity) | if uniformly controlled | will quantify contractivity (limit expansivity) of the flow.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An epidemiological survey of the vectors of cutaneous leishmaniasis ("espúndia" type) was caried out in the Alto Beni region of Bolivia, an area of Andean foothills at the Eastern limit of the Amazonian lowlands. The climate is typical wet tropical (15ºS latitude). Anthropophilic phlebotomine sandfly species were sampled at 20 sites, all forested. The importance of species from the Psychodopygus group, already suspected as a vector in the transmission of Leishmania from the braziliensis complex, was confirmed by: 1) the aggressiveness and diversity of the species encountered (83% of catches, nine species), 2) the discovery of a new anthropophilic species, P. yucumensis and 3) the isolation of a strain of Leishmania braziliensis braziliensis indistinguishable from human strains from the same area, from two species, P. llanosmartinsi and P. yucumensis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Molecular monitoring of BCR/ABL transcripts by real time quantitative reverse transcription PCR (qRT-PCR) is an essential technique for clinical management of patients with BCR/ABL-positive CML and ALL. Though quantitative BCR/ABL assays are performed in hundreds of laboratories worldwide, results among these laboratories cannot be reliably compared due to heterogeneity in test methods, data analysis, reporting, and lack of quantitative standards. Recent efforts towards standardization have been limited in scope. Aliquots of RNA were sent to clinical test centers worldwide in order to evaluate methods and reporting for e1a2, b2a2, and b3a2 transcript levels using their own qRT-PCR assays. Total RNA was isolated from tissue culture cells that expressed each of the different BCR/ABL transcripts. Serial log dilutions were prepared, ranging from 100 to 10-5, in RNA isolated from HL60 cells. Laboratories performed 5 independent qRT-PCR reactions for each sample type at each dilution. In addition, 15 qRT-PCR reactions of the 10-3 b3a2 RNA dilution were run to assess reproducibility within and between laboratories. Participants were asked to run the samples following their standard protocols and to report cycle threshold (Ct), quantitative values for BCR/ABL and housekeeping genes, and ratios of BCR/ABL to housekeeping genes for each sample RNA. Thirty-seven (n=37) participants have submitted qRT-PCR results for analysis (36, 37, and 34 labs generated data for b2a2, b3a2, and e1a2, respectively). The limit of detection for this study was defined as the lowest dilution that a Ct value could be detected for all 5 replicates. For b2a2, 15, 16, 4, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. For b3a2, 20, 13, and 4 labs showed a limit of detection at the 10-5, 10-4, and 10-3 dilutions, respectively. For e1a2, 10, 21, 2, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. Log %BCR/ABL ratio values provided a method for comparing results between the different laboratories for each BCR/ABL dilution series. Linear regression analysis revealed concordance among the majority of participant data over the 10-1 to 10-4 dilutions. The overall slope values showed comparable results among the majority of b2a2 (mean=0.939; median=0.9627; range (0.399 - 1.1872)), b3a2 (mean=0.925; median=0.922; range (0.625 - 1.140)), and e1a2 (mean=0.897; median=0.909; range (0.5174 - 1.138)) laboratory results (Fig. 1-3)). Thirty-four (n=34) out of the 37 laboratories reported Ct values for all 15 replicates and only those with a complete data set were included in the inter-lab calculations. Eleven laboratories either did not report their copy number data or used other reporting units such as nanograms or cell numbers; therefore, only 26 laboratories were included in the overall analysis of copy numbers. The median copy number was 348.4, with a range from 15.6 to 547,000 copies (approximately a 4.5 log difference); the median intra-lab %CV was 19.2% with a range from 4.2% to 82.6%. While our international performance evaluation using serially diluted RNA samples has reinforced the fact that heterogeneity exists among clinical laboratories, it has also demonstrated that performance within a laboratory is overall very consistent. Accordingly, the availability of defined BCR/ABL RNAs may facilitate the validation of all phases of quantitative BCR/ABL analysis and may be extremely useful as a tool for monitoring assay performance. Ongoing analyses of these materials, along with the development of additional control materials, may solidify consensus around their application in routine laboratory testing and possible integration in worldwide efforts to standardize quantitative BCR/ABL testing.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Captan and folpet are fungicides largely used in agriculture. They have similar chemical structures, except that folpet has an aromatic ring unlike captan. Their half-lives in blood are very short, given that they are readily broken down to tetrahydrophthalimide (THPI) and phthalimide (PI), respectively. Few authors measured these biomarkers in plasma or urine, and analysis was conducted either by gas chromatography coupled to mass spectrometry or liquid chromatography with UV detection. The objective of this study was thus to develop simple, sensitive and specific liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS) methods to quantify both THPI and PI in human plasma and urine. Briefly, deuterated THPI was added as an internal standard and purification was performed by solid-phase extraction followed by LC/APCI-MS/MS analysis in negative ion mode for both compounds. Validation of the methods was conducted using spiked blank plasma and urine samples at concentrations ranging from 1 to 250 μg/L and 1 to 50 μg/L, respectively, along with samples of volunteers and workers exposed to captan or folpet. The methods showed a good linearity (R (2) > 0.99), recovery (on average 90% for THPI and 75% for PI), intra- and inter-day precision (RSD, <15%) and accuracy (<20%), and stability. The limit of detection was 0.58 μg/L in urine and 1.47 μg/L in plasma for THPI and 1.14 and 2.17 μg/L, respectively, for PI. The described methods proved to be accurate and suitable to determine the toxicokinetics of both metabolites in human plasma and urine.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Clenbuterol is a β2 agonist agent with anabolic properties given by the increase in the muscular mass in parallel to the decrease of the body fat. For this reason, the use of clenbuterol is forbidden by the World Anti-Doping Agency (WADA) in the practice of sport. This compound is of particular interest for anti-doping authorities and WADA-accredited laboratories due to the recent reporting of risk of unintentional doping following the eating of meat contaminated with traces of clenbuterol in some countries. In this work, the development and the validation of an ultra-high pressure liquid chromatography coupled to electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS) method for the quantification of clenbuterol in human urine is described. The analyte was extracted from urine samples by liquid-liquid extraction (LLE) in basic conditions using tert butyl-methyl ether (TBME) and analyzed by UHPLC-MS/MS with a linear gradient of acetonitrile in 9min only. The simple and rapid method presented here was validated in compliance with authority guidelines and showed a limit of quantification at 5pg/mL and a linearity range from 5pg/mL to 300pg/mL. Good trueness (85.8-105%), repeatability (5.7-10.6% RSD) and intermediate precision (5.9-14.9% RSD) results were obtained. The method was then applied to real samples from eighteen volunteers collecting urines after single oral doses administration (1, 5 and 10μg) of clenbuterol-enriched yogurts.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Furosemide (FD: Lasix) is a loop diuretic which strongly increases both urine flow and electrolyte urinary excretion. Healthy volunteers were administered 40 mg orally (dissolved in water) and concentrations of FD were determined in serum and urine for up to 6 h for eight subjects, who absorbed water at a rate of 400 ml/h. Quantification was performed by HPLC with fluorescence detection (excitation at 233 nm, emission at 389 nm) with a limit of detection of 5 ng/ml for a 300-microliters sample. The elution of FD was completed within 4 min using a gradient of acetonitrile concentration rising from 30 to 50% in 0.08 M phosphoric acid. The delay to the peak serum concentration ranged from 60 to 120 min. FD was still easily measurable in the sera from all subjects 6 h after administration. In urine, the excretion rates reached their maximum between 1 and 3 h. The total amount of FD excreted in the urine averaged 11.2 mg (range 7.6-14.0 mg), with a mean urine volume of 3024 ml (range 2620-3596 ml). Moreover, the urine density was lower than 1.010 (recommended as an upper limit in doping analysis to screen diuretics) only for 2 h. An additional volunteer was administered 40 mg of FD and his urine was collected over a longer period. FD was still detectable 48 h after intake. Gas chromatography-mass spectrometry with different types of ionization was used to confirm the occurrence of FD after permethylation of the extract. Negative-ion chemical ionization, with ammonia as reactant gas, was found to be the most sensitive method of detection.