965 resultados para hydraulic pump


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work aims to conduct a study of the economic feasibility of the implementation of variable frequency inverters in pump systems with variable flow rates. The concern with the reduction of energy expenditure in industries raised in 2001 due to the energy crisis that hit Brazil at that time, forcing industries to reduce their electric costs under penalty of fines if this were not done (MOREIRA, 2008). Frequency inverter is an electronic device that allow greater control in the operation of pumping systems and also a reduction in electrical consumption, being a viable solution to achieve a reduction in energy consumption. For the development of this work, approaching important topics in pumping systems was necessary in order to make a correct choice of hydraulic pumping and also other components responsible for the operation of the system , such as electric motors and frequency inverters. In the case study, a theoretical analysis of the behavior of electrical consumption in systems with variable flow rates was performed, comparing when the system is operated via frequency inverters and when the system is operated without such a device. As expected, the result of the implantation of the device was quite satisfactory, and the primary goal of reducing energy expenditure was achieved. Also important to highlight the environmental issue of this work, as all forms of energy production affects nature in some way, achieving a reduction in consumption also contributes indirectly in environmental conservation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In situ megascale hydraulic diffusivities (D) of a confined loess aquifer were estimated at various scales (10 <= L <= 1500 m) by a finite difference model, and laboratory microscale diffusivities of a loess sample by empirical formulas. A scatter plot reveals that D fits to a single power function of L, providing that microscale diffusivities are assigned to L = 1 m and that differences in diffusivity observed between micro- and megascales are assigned to medium heterogeneity appraised by variations in the curvature and slope of natural hydraulic head waves propagating through the aquifer. Subsequently, a general power relationship between D and L is defined where the base and exponent terms stand for the aquifer storage capability under a confined regime of flow, for the microscale hydraulic conductivity and specific yield of loess, and for the changes in curvature and slope of hydraulic head waves relative to values defined at unit scale.[GRAPHICS]Editor Z.W. Kundzewicz

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temporomandibular joint arthrocentesis is a method of flushing out the synovial fluid that is currently performed by providing a double puncture to the upper joint space. The traditional 2-needle technique has some restrictions, such as the difficulty in performing it in the presence of intra-articular adherences and in the female patients, because the space is very small. The adoption of a single-needle for fluid injection might have some advantages with respect to the traditional 2-needle approach in terms of easily, time of execution and tolerability. We describe a single needle technique and we recommend the use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of alternative energy systems in the current days is an urgent necessity due to the problems that the planet is facing as the heating and loss of ozone layer. The scarcity of conventional energy is another problem that must be solved for the future of humanity. It must be considered that the people are inhabiting places moved away not always with available energy. The application of technologies as automation and control can help us to solve this problem. Therefore, this work aimed at apply an equipment of industrial usage, the Programmable Logical Controller, PLC, in alternative energies systems, as eolic generation and fotovoltaic generation used for water pumping, aiming the automatic control and the efficiency in the places where it has simultaneous availability of these sources, based in criterion of priority that previously established itself between them. It was made a hydraulic and energetic evaluation of the energy system, eolic and fotovoltaic, used in the automatic control system of pumping, in the place of accomplishment of the experiment, according to previously established physical conditions. The results have shown that the control system using the PLC is practicable and has trustworthiness. The program developed can be adapted for the use with several power plants in a specific application place. The fotovoltaic system of pumping, using a polycrystalline of 70 Watts connected to a pump Shurflo 8000, showed to be efficient with significant flows in almost all the months. The eolic system of pumping, using an eolic generator of 400 Watts assembled in place of experiment, did not demonstrate energetic capacity for use in this specific type of application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since ancient times, it has been a huge challenge to all people around the world to manage to get their fresh water, keeping it clean and providing it to every human being, so that it can be used for their daily needs. This is especially true for small properties in the countryside and in isolated areas with low demographic density. Pumping the water in those regions is a solution that rationalizes its use in domestic chores, in animal rearing and in the irrigation systems of cultivated areas. Making feasible local, renewable and non-polluted energetic alternatives is the aim for those areas that are usually far away from the public electric network. Using photovoltaic solar energy is the alternative now proposed. For this objective was built a system with two monocrystalline panels, one pump, two water tanks, two level sensors and a solenoid valve to pump water, using a pump powered an array of monocrystalline solar panels. The main goal was to compare their rate of water flow and their energy consumption. The use of one data acquisition equipment allowed collecting meteorological, electrical and hydraulic values, and also serving for the control and activation of the pumping system. During four months in a row as from April 2009, arrangements with one or two panels were tested. Mathematics correlations and adjustment lines were used to interpret the behavior of obtained dataset. During the analyzed period the system followed the linear equations with great accuracy. The daily average amount of water pumped by the several tested arrays stayed between 1,100 and 2,500 liters, and that is enough to supply a small rural property. The pumping system with two panels effectively showed the major amount of water, but a system with one panel can be an economical solution until 1,500 liters on day. It did not characterize a direct relationship between power or quantity of photovoltaic panels and daily outflow of water pumping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flow pumps act as important devices in areas such as Bioengineering, Medicine, and Pharmacy, among other areas of Engineering, mainly for delivering liquids or gases at small-scale and precision flow rate quantities. Principles for pumping fluids based on piezoelectric actuators have been widely studied, since they allow the construction of pump systems for displacement of small fluid volumes with low power consumption. This work studies valveless piezoelectric diaphragm pumps for flow generation, which uses a piezoelectric ceramic (PZT) as actuator to move a membrane (diaphragm) up and down as a piston. The direction of the flow is guaranteed by valveless configuration based on a nozzle-diffuser system that privileges the flow in just one pumping direction. Most research efforts on development of valveless flow pump deal either with computational simulations based on simplified models or with simplified physical approaches based on analytical models. The main objective of this work is the study of a methodology to develop a low-cost valveless piezoelectric diaphragm flow pump using computational simulations, parametric study, prototype manufacturing, and experimental characterization. The parametric study has shown that the eccentricity of PZT layer and metal layer plays a key role in the performance of the pump.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background-The clinical significance of the interaction between clopidogrel and proton pump inhibitors (PPIs) remains unclear. Methods and Results-We examined the relationship between PPI use and 1-year cardiovascular events (cardiovascular death, myocardial infarction, or stroke) in patients with acute coronary syndrome randomized to clopidogrel or ticagrelor in a prespecified, nonrandomized subgroup analysis of the Platelet Inhibition and Patient Outcomes (PLATO) trial. The primary end point rates were higher for individuals on a PPI (n = 6539) compared with those not on a PPI (n = 12 060) at randomization in both the clopidogrel (13.0% versus 10.9%; adjusted hazard ratio [HR], 1.20; 95% confidence interval [CI], 1.04 -1.38) and ticagrelor (11.0% versus 9.2%; HR, 1.24; 95% CI, 1.07-1.45) groups. Patients on non-PPI gastrointestinal drugs had similar primary end point rates compared with those on a PPI (PPI versus non-PPI gastrointestinal treatment: clopidogrel, HR, 0.98; 95% CI, 0.79-1.23; ticagrelor, HR, 0.89; 95% CI, 0.73-1.10). In contrast, patients on no gastric therapy had a significantly lower primary end point rate (PPI versus no gastrointestinal treatment: clopidogrel, HR, 1.29; 95% CI, 1.12-1.49; ticagrelor, HR, 1.30; 95% CI, 1.14-1.49). Conclusions-The use of a PPI was independently associated with a higher rate of cardiovascular events in patients with acute coronary syndrome receiving clopidogrel. However, a similar association was observed between cardiovascular events and PPI use during ticagrelor treatment and with other non-PPI gastrointestinal treatment. Therefore, in the PLATO trial, the association between PPI use and adverse events may be due to confounding, with PPI use more of a marker for, than a cause of, higher rates of cardiovascular events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess adherence to proton pump inhibitor (PPI) treatment and associated variables in patients with gastroesophageal reflux disease (GERD). Cross-sectional and prospective comprising 240 consecutive adult patients, diagnosed with GERD for whom continuous use of standard or double dose of omeprazole had been prescribed. Patients were ranked as ne-GERD (162: 67.5%) or e-GERD classified according to the Los Angeles classification as A (48:20.0%), B (21:8.6%), C (1:0.5%), D (1:0.5%), and Barrett's esophagus (7:2.9%). The Morisky questionnaire was applied to assess adherence to therapy and a GERD questionnaire to assess symptoms and their impact. Adherence was correlated with demographics, cotherapies, comorbidities, treatment duration, symptoms scores, endoscopic findings, and patient awareness of their disease. 126 patients (52.5%) exhibited high level of adherence and 114 (47.5%) low level. Youngers (P= 0.002) or married (O.R. 2.41, P= 0.03 vs. widowers) patients had lower levels of adherence; symptomatic patients exhibited lower adherence (P= 0.02). All other variables studied had no influence on adherence. Patients with GERD attending a tertiary referral hospital in Sao Paulo exhibited a high rate of low adherence to the prescribed PPI therapy that may play a role in the therapy failure. Age <60 years, marital status and being symptomatic were risk factors for low adherence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN] Migrant biota transports carbon to the mesopelagic zone due to their feeding at the shallower layers and their defecation, respiration, excretion and mortality at depth. The so-called active flux has been considered a small number compared to gravitational sinking. Recent assessments in subtropical waters show an important effect due to predation by interzonal diel vertical migrants (DVMs). The consumption and subsequent transport of epipelagic zooplankton by DVMs (mainly micronekton) to the mesopelagic zone seemed similar to the mean gravitational export. However, the consequences of this active transport to the bathypelagic zone are almost unknown. Here, we show the effect of the Atlantic and Pacific equatorial upwelling systems on the vertical distribution of acoustic backscatter from the surface to bathypelagic depths. The enhancement of the acoustic signal below the upwelling zone was observed to reach 4000 m depth, coinciding with high abundances and activity of bacteria at those depths. The results suggest an active carbon transport from the epipelagic driven by zooplankton and micronekton, enhancing the efficiency of the biological pump and giving an insight about the fate of an increased productivity at the shallower layers of the ocean

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water distribution networks optimization is a challenging problem due to the dimension and the complexity of these systems. Since the last half of the twentieth century this field has been investigated by many authors. Recently, to overcome discrete nature of variables and non linearity of equations, the research has been focused on the development of heuristic algorithms. This algorithms do not require continuity and linearity of the problem functions because they are linked to an external hydraulic simulator that solve equations of mass continuity and of energy conservation of the network. In this work, a NSGA-II (Non-dominating Sorting Genetic Algorithm) has been used. This is a heuristic multi-objective genetic algorithm based on the analogy of evolution in nature. Starting from an initial random set of solutions, called population, it evolves them towards a front of solutions that minimize, separately and contemporaneously, all the objectives. This can be very useful in practical problems where multiple and discordant goals are common. Usually, one of the main drawback of these algorithms is related to time consuming: being a stochastic research, a lot of solutions must be analized before good ones are found. Results of this thesis about the classical optimal design problem shows that is possible to improve results modifying the mathematical definition of objective functions and the survival criterion, inserting good solutions created by a Cellular Automata and using rules created by classifier algorithm (C4.5). This part has been tested using the version of NSGA-II supplied by Centre for Water Systems (University of Exeter, UK) in MATLAB® environment. Even if orientating the research can constrain the algorithm with the risk of not finding the optimal set of solutions, it can greatly improve the results. Subsequently, thanks to CINECA help, a version of NSGA-II has been implemented in C language and parallelized: results about the global parallelization show the speed up, while results about the island parallelization show that communication among islands can improve the optimization. Finally, some tests about the optimization of pump scheduling have been carried out. In this case, good results are found for a small network, while the solutions of a big problem are affected by the lack of constraints on the number of pump switches. Possible future research is about the insertion of further constraints and the evolution guide. In the end, the optimization of water distribution systems is still far from a definitive solution, but the improvement in this field can be very useful in reducing the solutions cost of practical problems, where the high number of variables makes their management very difficult from human point of view.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to its practical importance and inherent complexity, the optimisation of distribution networks for supplying drinking water has been the subject of extensive study for the past 30 years. The optimization is governed by sizing the pipes in the water distribution network (WDN) and / or optimises specific parts of the network such as pumps, tanks etc. or try to analyse and optimise the reliability of a WDN. In this thesis, the author has analysed two different WDNs (Anytown City and Cabrera city networks), trying to solve and optimise a multi-objective optimisation problem (MOOP). The main two objectives in both cases were the minimisation of Energy Cost (€) or Energy consumption (kWh), along with the total Number of pump switches (TNps) during a day. For this purpose, a decision support system generator for Multi-objective optimisation used. Its name is GANetXL and has been developed by the Center of Water System in the University of Exeter. GANetXL, works by calling the EPANET hydraulic solver, each time a hydraulic analysis has been fulfilled. The main algorithm used, was a second-generation algorithm for multi-objective optimisation called NSGA_II that gave us the Pareto fronts of each configuration. The first experiment that has been carried out was the network of Anytown city. It is a big network with a pump station of four fixed speed parallel pumps that are boosting the water dynamics. The main intervention was to change these pumps to new Variable speed driven pumps (VSDPs), by installing inverters capable to diverse their velocity during the day. Hence, it’s been achieved great Energy and cost savings along with minimisation in the number of pump switches. The results of the research are thoroughly illustrated in chapter 7, with comments and a variety of graphs and different configurations. The second experiment was about the network of Cabrera city. The smaller WDN had a unique FS pump in the system. The problem was the same as far as the optimisation process was concerned, thus, the minimisation of the energy consumption and in parallel the minimisation of TNps. The same optimisation tool has been used (GANetXL).The main scope was to carry out several and different experiments regarding a vast variety of configurations, using different pump (but this time keeping the FS mode), different tank levels, different pipe diameters and different emitters coefficient. All these different modes came up with a large number of results that were compared in the chapter 8. Concluding, it should be said that the optimisation of WDNs is a very interested field that has a vast space of options to deal with. This includes a large number of algorithms to choose from, different techniques and configurations to be made and different support system generators. The researcher has to be ready to “roam” between these choices, till a satisfactory result will convince him/her that has reached a good optimisation point.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Il CP-ESFR è un progetto integrato di cooperazione europeo sui reattori a sodio SFR realizzato sotto il programma quadro EURATOM 7, che unisce il contributo di venticinque partner europei. Il CP-ESFR ha l'ambizione di contribuire all'istituzione di una "solida base scientifica e tecnica per il reattore veloce refrigerato a sodio, al fine di accelerare gli sviluppi pratici per la gestione sicura dei rifiuti radioattivi a lunga vita, per migliorare le prestazioni di sicurezza, l'efficienza delle risorse e il costo-efficacia di energia nucleare al fine di garantire un sistema solido e socialmente accettabile di protezione della popolazione e dell'ambiente contro gli effetti delle radiazioni ionizzanti. " La presente tesi di laurea è un contributo allo sviluppo di modelli e metodi, basati sull’uso di codici termo-idraulici di sistema, per l’ analisi di sicurezza di reattori di IV Generazione refrigerati a metallo liquido. L'attività è stata svolta nell'ambito del progetto FP-7 PELGRIMM ed in sinergia con l’Accordo di Programma MSE-ENEA(PAR-2013). Il progetto FP7 PELGRIMM ha come obbiettivo lo sviluppo di combustibili contenenti attinidi minori 1. attraverso lo studio di due diverse forme: pellet (oggetto della presente tesi) e spherepac 2. valutandone l’impatto sul progetto del reattore CP-ESFR. La tesi propone lo sviluppo di un modello termoidraulico di sistema dei circuiti primario e intermedio del reattore con il codice RELAP5-3D© (INL, US). Tale codice, qualificato per il licenziamento dei reattori nucleari ad acqua, è stato utilizzato per valutare come variano i parametri del core del reattore rilevanti per la sicurezza (es. temperatura di camicia e di centro combustibile, temperatura del fluido refrigerante, etc.), quando il combustibile venga impiegato per “bruciare” gli attinidi minori (isotopi radioattivi a lunga vita contenuti nelle scorie nucleari). Questo ha comportato, una fase di training sul codice, sui suoi modelli e sulle sue capacità. Successivamente, lo sviluppo della nodalizzazione dell’impianto CP-ESFR, la sua qualifica, e l’analisi dei risultati ottenuti al variare della configurazione del core, del bruciamento e del tipo di combustibile impiegato (i.e. diverso arricchimento di attinidi minori). Il testo è suddiviso in sei sezioni. La prima fornisce un’introduzione allo sviluppo tecnologico dei reattori veloci, evidenzia l’ambito in cui è stata svolta questa tesi e ne definisce obbiettivi e struttura. Nella seconda sezione, viene descritto l’impianto del CP-ESFR con attenzione alla configurazione del nocciolo e al sistema primario. La terza sezione introduce il codice di sistema termico-idraulico utilizzato per le analisi e il modello sviluppato per riprodurre l’impianto. Nella sezione quattro vengono descritti: i test e le verifiche effettuate per valutare le prestazioni del modello, la qualifica della nodalizzazione, i principali modelli e le correlazioni più rilevanti per la simulazione e le configurazioni del core considerate per l’analisi dei risultati. I risultati ottenuti relativamente ai parametri di sicurezza del nocciolo in condizioni di normale funzionamento e per un transitorio selezionato sono descritti nella quinta sezione. Infine, sono riportate le conclusioni dell’attività.