961 resultados para high vaccine dose


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work aimed to create a mailable and OSLD-based phantom with accuracy suitable for RPC audits of HDR brachytherapy sources at institutions participating in NCI-funded cooperative clinical trials. An 8 × 8 × 10 cm3 prototype with two slots capable of holding nanoDot Al2O3:C OSL dosimeters (Landauer, Glenwood, IL) was designed and built. The phantom has a single channel capable of accepting all 192Ir HDR brachytherapy sources in current clinical use in the United States. Irradiations were performed with an 192Ir HDR source to determine correction factors for linearity with dose, dose rate, and the combined effect of irradiation energy and phantom construction. The uncertainties introduced by source positioning in the phantom and timer resolution limitations were also investigated. It was found that the linearity correction factor was where dose is in cGy, which differed from that determined by the RPC for the same batch of dosimeters under 60Co irradiation. There was no significant dose rate effect. Separate energy+block correction factors were determined for both models of 192Ir sources currently in clinical use and these vendor-specific correction factors differed by almost 2.6%. For Nucletron sources, this correction factor was 1.026±0.004 (99% Confidence Interval) and for Varian sources it was 1.000±0.007 (99% CI). Reasonable deviations in source positioning within the phantom and the limited resolution of the source timer had insignificant effects on the ability to measure dose. Overall measurement uncertainty of the system was estimated to be ±2.5% for both Nucletron and Varian source audits (95% CI). This uncertainty was sufficient to establish a ±5% acceptance criterion for source strength audits under a formal RPC audit program. Trial audits of eight participating institutions resulted in an average RPC-to-institution dose ratio of 1.000 with a standard deviation of 0.011.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The effectiveness of the Anisotropic Analytical Algorithm (AAA) implemented in the Eclipse treatment planning system (TPS) was evaluated using theRadiologicalPhysicsCenteranthropomorphic lung phantom using both flattened and flattening-filter-free high energy beams. Radiation treatment plans were developed following the Radiation Therapy Oncology Group and theRadiologicalPhysicsCenterguidelines for lung treatment using Stereotactic Radiation Body Therapy. The tumor was covered such that at least 95% of Planning Target Volume (PTV) received 100% of the prescribed dose while ensuring that normal tissue constraints were followed as well. Calculated doses were exported from the Eclipse TPS and compared with the experimental data as measured using thermoluminescence detectors (TLD) and radiochromic films that were placed inside the phantom. The results demonstrate that the AAA superposition-convolution algorithm is able to calculate SBRT treatment plans with all clinically used photon beams in the range from 6 MV to 18 MV. The measured dose distribution showed a good agreement with the calculated distribution using clinically acceptable criteria of ±5% dose or 3mm distance to agreement. These results show that in a heterogeneous environment a 3D pencil beam superposition-convolution algorithms with Monte Carlo pre-calculated scatter kernels, such as AAA, are able to reliably calculate dose, accounting for increased lateral scattering due to the loss of electronic equilibrium in low density medium. The data for high energy plans (15 MV and 18 MV) showed very good tumor coverage in contrast to findings by other investigators for less sophisticated dose calculation algorithms, which demonstrated less than expected tumor doses and generally worse tumor coverage for high energy plans compared to 6MV plans. This demonstrates that the modern superposition-convolution AAA algorithm is a significant improvement over previous algorithms and is able to calculate doses accurately for SBRT treatment plans in the highly heterogeneous environment of the thorax for both lower (≤12 MV) and higher (greater than 12 MV) beam energies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In Filipino infants, 1 dose of an adjuvanted, 11-valent pneumococcal conjugate vaccine (serotypes 1, 4, 5, 7F, 9V, 19F, and 23F conjugated to tetanus protein; and serotypes 3, 6B, 14, and 18C conjugated to diphtheria toxoid) administered alone at age 18 weeks (11PncTD1) elicited similar antibody concentrations at age 9 months as those elicited by 3 doses (11PncTD3) administered concomitantly with national program vaccines, at ages 6, 10, and 14 weeks. Geometric mean antibody concentrations ranged from 0.36 mug/mL ( for serotype 18C) to 5.81 mug/mL (for serotype 4), for the 11PncTD1 vaccine, and from 0.32 mug/mL (for serotype 18C) to 5.01 mug/mL (for serotype 19F), for the 11PncTD3 vaccine. The proportion of infants with threshold antibody concentrations greater than or equal to0.35 mug/mL was also similar (ranges, 55.6%-100% for the 11PncTD1 vaccine and 42.9%-100% for the 11PncTD3 vaccine). The functional activity of antibodies expressed as opsonophagocytic activity titers was similar in the 11PncTD1 and 11PncTD3 groups. This finding is an important one for countries with financial constraints and high pneumococcal disease burden.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Using native chemical ligation, we synthesized a group A streptococcal. (GAS) vaccine that contained three different GAS M protein peptide epitopes in a chemically well-characterized construct in high purity. Two of the peptide epitopes represented variable amino terminal serotype determinants, and the third represented a carboxyl terminal conserved region determinant of the GAS M protein. We also synthesized a lipid core peptide (LCP) construct containing the same three peptides. Upon immunization of mice, the non-LCP construct only elicited antibody responses to all three epitopes with the use of adjuvant. The LCP construct, however, elicited excellent antibody responses to all three epitopes without the need for any additional adjuvant or carrier. We have synthesized the LCP synthetic vaccine system with good reproducibility.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Many viruses including HIV, hepatitis C and hepatitis B, have an outer lipid envelope which maintains inserted viral peptides in the “correct” functional conformation and orientation. Disruption of the lipid envelope by most solvents destroys infectivity and often results in a loss of antigenicity. This communication outlines a novel approach to viral inactivation by specific solvent delipidation which modifies the whole virion rendering it non-infective, but antigenic. Duck hepatitis B virus (DHBV) was delipidated using a diisopropylether (DIPE) and butanol mixture and residual infectivity tested by inoculation into day-old ducks. Delipidation completely inactivated the DHBV (p < 0.001). Delipidated DHBV was then used to vaccinate ducks. Three doses of delipidated DHBV induced anti-DHBs antibody production and prevented high dose challenge infection in five out of six ducks. In comparison, five of six ducks vaccinated with undelipidated DHBV and four of four ducks vaccinated with glutaraldehyde inactivated DHBV were unprotected (p < 0.05). Although this solvent system completely inactivated DHBV, viral antigens were retained in an appropriate form to induce immunity. Delipidation of enveloped viruses with specific organic solvents has potential as the basis for development of vaccines.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to compare the outcomes associated with two differing right unilateral (RUL) electroconvulsive therapy (ECT) dosing protocols: 2-3X seizure threshold (2-3X ST) and fixed high dose (FHD) at 353 mC. A retrospective chart review was performed to compare patient outcomes during the implementation of two different dosing protocols: 2-3X ST from October 2000 to May 2001 and FHD from June 2001 to February 2002. A total of 56 patients received ECT under the 2-3X ST protocol, and 46 received ECT under the FHD protocol. In total, 13.6% of patients receiving ECT according to the 2-3X ST protocol received more than 12 ECT, whereas none of the FHD group received more than 12 ECT. The mean number of ECT per treatment course reduced significantly from 7.6 to 5.7 following the switch from the 2-3X ST protocol to the FHD protocol. There were no significant differences between the two groups in the incidence of adverse cognitive effects. ECT practitioners adhered to the 2-3X ST protocol for only 51.8% of ECT courses, with protocol adherence improving to 87% following introduction of the FHD protocol. Although this naturalistic retrospective chart survey had significant methodological limitations, it found that practitioners are more likely to correctly adhere to a fixed dose protocol, therefore, increasing its 'real world' effectiveness in comparison to titrated suprathreshold dosing techniques. The FHD protocol was associated with shorter courses of ECT than the 2-3X ST protocol, with no significant difference between the two protocols in clinically discernable adverse cognitive effects.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A randomized double-blind Phase I Trial was conducted to evaluate safety, tolerability, and immunogenicity of a yellow fever (YF)-dengue 2 (DEN2) chimera (ChimeriVax™-DEN2) in comparison to that of YF vaccine (YF-VAX®). Forty-two healthy YF naïve adults randomly received a single dose of either ChimeriVax™-DEN2 (high dose, 5 log plaque forming units [PFU] or low dose, 3 log PFU) or YF-VAXâ by the subcutaneous route (SC). To determine the effect of YF pre-immunity on the ChimeriVaxTM-DEN2 vaccine, 14 subjects previously vaccinated against YF received a high dose of ChimeriVax™-DEN2 as an open-label vaccine. Most adverse events were similar to YF-VAX® and of mild to moderate intensity, with no serious side-effects. One hundred percent and 92.3% of YF naïve subjects inoculated with 5.0 and 3.0 log10 PFU of ChimeriVaxTM-DEN2, respectively, seroconverted to wt DEN2 (strain 16681); 92% of subjects inoculated with YF-VAX® seroconverted to YF 17D virus but none of YF naïve subjects inoculated with ChimeriVax-DEN2 seroconverted to YF 17D virus. Low seroconversion rates to heterologous DEN serotypes 1, 3, and 4 were observed in YF naïve subjects inoculated with either ChimeriVax™-DEN2 or YF-VAX®. In contrast, 100% of YF immune subjects inoculated with ChimeriVax™-DEN2 seroconverted to all 4 DEN serotypes. Surprisingly, levels of neutralizing antibodies to DEN 1, 2, and 3 viruses in YF immune subjects persisted after 1 year. These data demonstrated that 1) the safety and immunogenicity profile of the ChimeriVax™-DEN2 vaccine is consistent with that of YF-VAX®, and 2) pre-immunity to YF virus does not interfere with ChimeriVaxTM-DEN2 immunization, but induces a long lasting and cross neutralizing antibody response to all 4 DEN serotypes. The latter observation can have practical implications toward development of a dengue vaccine.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background. Postoperative cognitive dysfunction (POCD) after coronary artery bypass graft surgery is a common complication for which, despite many clinical investigations, no definitive etiology has been found. The current use of both high and low-dose fentanyl as anesthetic techniques allowed us to investigate the effect of fentanyl on the incidence of POCD. Methods. Three hundred fifty patients scheduled to undergo elective coronary artery bypass graft surgery were randomized to receive either high-dose fentanyl (50 mu g/kg) or low-dose fentanyl (10 mu g/kg) as the basis of the anesthetic. All patients underwent neuropsychological testing before surgery and at 1 week, 3 months, and 12 months after surgery. Results. One hundred sixty-eight patients in the low-dose group and 158 patients in the high-dose group were included in the final analysis. Neuropsychological testing was performed on 88%, 93%, and 92% of patients at 1 week, 3 months, and 12 months, respectively. There was no difference between group mean scores at any of the three testing times. Analysis of individual patients by the 20% rule did not detect any differences between groups. The one SD rule, which has fewer false-positive results, detected significantly more patients with POCD in the low-dose group than in the high-dose group at 1 week (23.6% vs. 13.7%; P = 0.03) but not at the other testing times. Patients with POCD spent an average of 1.2 days longer in the hospital than those without POCD (P = 0.021). Conclusions: High-dose fentanyl is not associated with a difference in the incidence of POCD at 3 or 12 months after surgery. Low-dose fentanyl leads to shorter postoperative ventilation times and may be associated with a greater incidence of POCD 1 week after surgery. Early POCD is associated with an increased duration of stay in the hospital.