903 resultados para high pressure liquid-vapor equilibria


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Implementing precise techniques in routine diagnosis of chronic granulomatous disease (CGD), which expedite the screening of molecular defects, may be critical for a quick assumption of patient prognosis. This study compared the efficacy of single-strand conformation polymorphism analysis (SSCP) and high-performance liquid chromatography under partially denaturing conditions (dHPLC) for screening mutations in CGD patients. We selected 10 male CGD patients with a clinical history of severe recurrent infections and abnormal respiratory burst function. gDNA, mRNA and cDNA samples were prepared by standard methods. CYBB exons were amplified by PCR and screened by SSCP or dHPLC. Abnormal DNA fragments were sequenced to reveal the nature of the mutations. The SSCP and dHPLC methods showed DNA abnormalities, respectively, in 55% and 100% of the cases. Sequencing of the abnormal DNA samples confirmed mutations in all cases. Four novel mutations in CYBB were identified which were picked up only by the dHPLC screening (c.904 insC, c.141+5 g>t, c.553 T>C, and c.665 A>T). This work highlights the relevance of dHPLC, a sensitive, fast, reliable and cost-effective method for screening mutations in CGD, which in combination with functional assays assessing the phagocyte respiratory burst will contribute to expedite the definitive diagnosis of X-linked CGD, direct treatment, genetic counselling and to have a clear assumption of the prognosis. This strategy is especially suitable for developing countries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, rapid and selective method using high-performance liquid chromatography with ultraviolet detection (267 nm) was applied for the determination of tryptophan in plasma. Separation was carried out on a C18 column (150 x 4.6 mm internal diameter) in 6 min. The mobile phase consisted of 5 mM the sodium acetate and acetonitrile (92:8, v/v). The method was shown to be precise and accurate, and good recovery of analyte was achieved, characterizing the method as efficient and reliable for use in laboratory analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Styrax camporum Pohl, known in Brazil as estoraque do campo or cuia de brejo, has been used in the treatment of gastrointestinal diseases. The therapeutic action of S. camporum has been attributed to the ethyl acetate fraction, although the chemical composition of this fraction has not yet been analyzed. In this study, a high-performance liquid chromatography photodiode array detection (HPLC-PAD) method for analysis of Brazilian Styrax species has been developed. The compounds egonol (1) and homoegonol (2) were found to be present in all the samples investigated by HPLC. These compounds were isolated by open column chromatography followed by preparative TLC, and were identified by 1H NMR. Compounds 1 and 2 were thus proposed as phytochemical markers for Styrax, owing to their biological properties and presence in other Styrax species. The developed method has been validated and successfully applied for quantification of 1 and 2 in S. camporum dried leaves and crude ethanolic extracts from S. ferrugineus and S. pohlii aerial parts. Copyright (c) 2011 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents simple, rapid, precise and accurate stability-indicating HPLC and CE methods, which were developed and validated for the determination of nitrendipine, nimodipine and nisoldipine. These drugs are calcium channel antagonists of the 1,4-dihydropyridine type which are used in the treatment of cardiovascular diseases. Experimental results showed a good linear correlation between the area and the concentration of drugs covering a relatively large domain of concentration in all cases. The linearity of the analytical procedures was in the range of 2.0-120.0 mu g mL-1 for nitrendipine, 1.0-100.0 mu g mL(-1) for nimodipine and 100.0-600.0 mu g mL(-1) for nisoldipine, the regression determination coefficient being higher than 0.99 in all cases. The proposed methods were found to have good precision and accuracy. The chemical stability of these drugs was determined under various conditions and the methods have shown adequate separation for their enantiomers and degradation products. In addition, degradation products produced as a result of stress studies did not interfere with the detection of the drugs' enantiomers and the assays can thus be considered stability-indicating.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, rapid and selective method using high-performance liquid chromatography with ultraviolet detection (267 nm) was applied for the determination of tryptophan in plasma. Separation was carried out on a C18 column (150 x 4.6 mm internal diameter) in 6 min. The mobile phase consisted of 5 mM the sodium acetate and acetonitrile (92:8, v/v). The method was shown to be precise and accurate, and good recovery of analyte was achieved, characterizing the method as efficient and reliable for use in laboratory analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives The current study investigated to what extent task-specific practice can help reduce the adverse effects of high-pressure on performance in a simulated penalty kick task. Based on the assumption that practice attenuates the required attentional resources, it was hypothesized that task-specific practice would enhance resilience against high-pressure. Method Participants practiced a simulated penalty kick in which they had to move a lever to the side opposite to the goalkeeper's dive. The goalkeeper moved at different times before ball-contact. Design Before and after task-specific practice, participants were tested on the same task both under low- and high-pressure conditions. Results Before practice, performance of all participants worsened under high-pressure; however, whereas one group of participants merely required more time to correctly respond to the goalkeeper movement and showed a typical logistic relation between the percentage of correct responses and the time available to respond, a second group of participants showed a linear relationship between the percentage of correct responses and the time available to respond. This implies that they tended to make systematic errors for the shortest times available. Practice eliminated the debilitating effects of high-pressure in the former group, whereas in the latter group high-pressure continued to negatively affect performance. Conclusions Task-specific practice increased resilience to high-pressure. However, the effect was a function of how participants responded initially to high-pressure, that is, prior to practice. The results are discussed within the framework of attentional control theory (ACT).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid, sensitive and specific method for quantifying hydroxocobalamin in human plasma using paracetamol as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using an organic solvent (ethanol 100%; -20°C). The extracts were analyzed by high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS-MS). Chromatography was performed on Prevail C8 3 μm, analytical column (2.1×100 mm i.d.). The method had a chromatographic run time of 3.4 min and a linear calibration curve over the range 5-400 ng.mL-1 (r>0.9983). The limit of quantification was 5 ng.mL-1. The method was also validated without the use of the internal standard. The precision in the intra-batch validation with IS was 9.6%, 8.9%, 1.0% and 2.8% whereas without IS was 9.2%, 8.2%, 1.8% and 1.5% for 5, 15, 80 and 320 ng/mL, respectively. The accuracy in intra-batch validation with IS was 108.9%, 99.9%, 98.9% and 99.0% whereas without IS was 101.1%, 99.3%, 97.5% and 92.5% for 5, 15, 80 and 320 ng/mL, respectively. The precision in the inter-batch validation with IS was 9.4%, 6.9%, 4.6% and 5.5% whereas without IS was 10.9%, 6.4%, 5.0% and 6.2% for 5, 15, 80 and 320 ng/mL, respectively. The accuracy in inter-batch validation with IS was 101.9%, 104.1%, 103.2% and 99.7% whereas without IS was 94.4%, 101.2%, 101.6% and 96.0% for 5, 15, 80 and 320 ng/mL, respectively. This HPLC-MS-MS procedure was used to assess the pharmacokinetics of Hydroxo cobalamin following intramuscular injection 5000 μg in healthy volunteers of both sexes (10 males and 10 females). The volunteers had the following clinical characteristics (according to gender and expressed as mean ± SD [range]): males: age: 32.40 ± 8.00 y [23.00-46.00], height: 1.73 ± 0.07 m [1.62-1.85], body weight: 72.48 ± 10.22 Kg [60.20- 88.00]; females: age: 28.60 ± 9.54 y [18.00-44.00], height: 1.60 ± 0.05 m [1.54-1.70], body weight: 58.64 ± 6.09 Kg [51.70- 66.70]. The following pharmacokinetic parameters were obtained from the hydroxocobalamin plasma concentration vs. time curves: AUClast, T1/2, Tmax, Vd, Cl, Cmax and Clast. The pharmacokinetic parameters were 120 (± 25) ng/mL for Cmax, 2044 (± 641) ng.h/mL for AUClast, 8 (± 3.2) ng.mL-1 for Clast, 38 (± 15.8) hr for T1/2 and 2.5 (range 1-6) hr for Tmax. Female volunteers presented significant (p=0.0136) lower AUC (1706 ± 704) ng.h/mL) and larger (p=0.0205) clearance (2.91 ± 1.41 L/hr), as compared to male 2383 ± 343 ng.h/mL and 1.76 ± 0.23 L/hr, respectively. These pharmacokinetic differences could explain the higher prevalence of vitamin B12 deficiency in female patients. The method described validated well without the use of the internal standard and this approach should be investigated in other HPLC-MS-MS methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Der Einfluß von Druck auf die Eigenschaften dünner dielektrischer Filme wurde mit Hilfe von Oberflächenplasmonen-Spektroskopie untersucht. Die Arbeit kann aus der Perspektive der Materialcharakterisierung und aus apparativer Sicht betrachtet werden, da z.B. eine neue Hochdruckzelle konstruiert wurde, die kombinierte Oberflächenplasmonen-Elektrochemie Messungen erlaubt. SiO2-Solgel Filme wurden optimiert und auf ihre Widerstandsfähigkeit in Bufferlösungen und ihre Oberflächeneigenschaften hin untersucht. Eine Anwendung lag in der Charakterisierung von thermoresponsiven Acrylsäureisopropylamid Hydrogelen, die einen Volumenphasenübergang aufwiesen, dessen Eigenschaften durch Druck und die Beschränktheit des Films auf die Oberfläche beeinflußt wurden.Die Charakterisierung von DNA Hybridisierungsreaktionen an Oberflächen wurde mit einer Fluoreszenz-erweiterten Hochdruckapparatur durchgeführt. Zunächst wurde die Stabilität der zugrundeliegenden Bindematrix sichergestellt. Bei DNA Einzelsträngen führten Temperatur und Druck zu jeweils verringertem bzw. erhöhtem Signal. Entropie und Änderungen der Lösungsmitteleigenschaften wurden für die Signaländerungen verantwortlich gemacht. Die Eigenschaften der Doppelhelix wurden im Langmuir-Bild beschrieben. Der Brechungsindex von Kohlendioxid wurde bis zu 200 MPa gemessen und mit vorhandenen Gleichungen verglichen. Weiterhin wurde das Schwellverhalten von PMMA in scCO2/MMA-Mischungen untersucht. Mit Druck und MMA-Konzentration nimmt das Polymer vermehrt Kohlendioxid auf. Dadurch schwillt es an und sein Brechungsindex nimmt ab. Berechnungen unter Annahme einer idealen Mixtur ergaben gute qualitative Übereinstimmung mit den Meßwerten.Abschließend wurde eine neue Elektrochemie-Hochdruckzelle vorgestellt, die an Kaliumhexacyanoferrat(III)-(II) getestet wurde. Die Elektropolymerisation von Thiophen optisch untersucht.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this PhD thesis was to evaluate the effect of a sub-lethal HPH treatment on some probiotic properties and on cell response mechanisms of already-known functional strains, isolated from Argentinean dairy products. The results achieved showed that HPH treatments, performed at a sub-lethal level of 50 MPa, increased some important functional and technological characteristics of the considered non intestinal probiotic strains. In particular, HPH could modify cell hydrophobicity, autoaggregation and resistance to acid gastric conditions (tested in in vitro model), cell viability and cell production of positive aroma compounds, during a refrigerate storage in a simulated dairy product. In addition, HPH process was able to increase also some probiotic properties exerted in vivo and tested for two of the considered strains. In fact, HPH-treated cells were able to enhance the number of IgA+ cells more than other not treated cells, although this capacity was time dependent. On the other hand, HPH treatment was able to modify some important characteristics that are linked to the cell wall and, consequently, could alter the adhesion capacity in vivo and the interaction with the intestinal cells. These modifications, involving cell outermost structures, were highlighted also by Trasmission Electron Microscopy (TEM) analysis. In fact, the micrographs obtained showed a significant effect of the pressure treatment on the cell morphology and particularly on the cell wall. Moreover, the results achieved showed that composition of plasma membranes and their level of unsaturation are involved in response mechanisms adopted by cells exposed to the sub-lethal HPH treatment. Although the response to the treatment varied according to the characteristics of individual strains, time of storage and suspension media employed, the results of present study, could be exploited to enhance the quality of functional products and to improve their organoleptic properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Questa tesi di laurea nasce dall’esperienza maturata presso la VM Motori S.p.A., ufficio CRM (Centro Ricerca Motori) di ingegneria, divisione del reparto R&D (Research and Development) situato a Cento di Ferrara. Durante tale esperienza sono state affrontate le problematiche inerenti al settore automotive riguardo la ricerca e lo sviluppo dei motori endotermici diesel. Dopo un approccio introduttivo, che definisce l’ambito lavorativo in cui opera VM Motori S.p.A. e l’oggetto della tesi, si passa alla definizione ed alla calibrazione di un circuito low pressure EGR di un propulsore diesel da 200HP@3800rpm di potenza e 500Nm@1600rpm di coppia per uso automobilistico, mediante l’ausilio dei software AδαMO, INCA, Controldesk Next Generation, DoE, DIAdem ed INDICOM, software per lo studio della calibrazione al banco sviluppo. Si analizzano gli aspetti che contraddistinguono la VM Motori S.p.A. dalle altre aziende specializzate nel settore automotive, facendo riferimento ai campi produttivi in cui si applica l’ingegneria meccanica ed analizzandone gli aspetti tecnici, metodici e gestionali. Da notare il ruolo fondamentale delle automotive nell’economia mondiale in riferimento alla produzione dei principali propulsori diesel, primarie fonti produttive della VM.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die causa finalis der vorliegenden Arbeit ist das Verständnis des Phasendiagramms von Wasserstoff bei ultrahohen Drücken, welche von nichtleitendem H2 bis hin zu metallischem H reichen. Da die Voraussetzungen für ultrahohen Druck im Labor schwer zu schaffen sind, bilden Computersimulationen ein wichtiges alternatives Untersuchungsinstrument. Allerdings sind solche Berechnungen eine große Herausforderung. Eines der größten Probleme ist die genaue Auswertung des Born-Oppenheimer Potentials, welches sowohl für die nichtleitende als auch für die metallische Phase geeignet sein muss. Außerdem muss es die starken Korrelationen berücksichtigen, die durch die kovalenten H2 Bindungen und die eventuellen Phasenübergänge hervorgerufen werden. Auf dieses Problem haben unsere Anstrengungen abgezielt. Im Kontext von Variationellem Monte Carlo (VMC) ist die Shadow Wave Function (SWF) eine sehr vielversprechende Option. Aufgrund ihrer Flexibilität sowohl lokalisierte als auch delokalisierte Systeme zu beschreiben sowie ihrer Fähigkeit Korrelationen hoher Ordnung zu berücksichtigen, ist sie ein idealer Kandidat für unsere Zwecke. Unglücklicherweise bringt ihre Formulierung ein Vorzeichenproblem mit sich, was die Anwendbarkeit limitiert. Nichtsdestotrotz ist es möglich diese Schwierigkeit zu umgehen indem man die Knotenstruktur a priori festlegt. Durch diesen Formalismus waren wir in der Lage die Beschreibung der Elektronenstruktur von Wasserstoff signifikant zu verbessern, was eine sehr vielversprechende Perspektive bietet. Während dieser Forschung haben wir also die Natur des Vorzeichenproblems untersucht, das sich auf die SWF auswirkt, und dabei ein tieferes Verständnis seines Ursprungs erlangt. Die vorliegende Arbeit ist in vier Kapitel unterteilt. Das erste Kapitel führt VMC und die SWF mit besonderer Ausrichtung auf fermionische Systeme ein. Kapitel 2 skizziert die Literatur über das Phasendiagramm von Wasserstoff bei ultrahohem Druck. Das dritte Kapitel präsentiert die Implementierungen unseres VMC Programms und die erhaltenen Ergebnisse. Zum Abschluss fasst Kapitel 4 unsere Bestrebungen zur Lösung des zur SWF zugehörigen Vorzeichenproblems zusammen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lamellar bodies are the storage sites for lung surfactant within type II alveolar epithelial cells. The structure-function models of lamellar bodies are based on microscopic analyses of chemically fixed tissue. Despite available alternative fixation methods that are less prone to artifacts, such as cryofixation by high-pressure freezing, the nature of the lung, being mostly air filled, makes it difficult to take advantage of these improved methods. In this paper, we propose a new approach and show for the first time the ultrastructure of intracellular lamellar bodies based on cryo-electron microscopy of vitreous sections in the range of nanometer resolution. Thus, unspoiled by chemical fixation, dehydration and contrasting agents, a close to native structure is revealed. Our approach uses perfluorocarbon to substitute the air in the alveoli. Lung tissue was subsequently high-pressure frozen, cryosectioned and observed in a cryo-electron microscope. The lamellar bodies clearly show a tight lamellar morphology. The periodicity of these lamellae was 7.3 nm. Lamellar bifurcations were observed in our cryosections. The technical approach described in this paper allows the examination of the native cellular ultrastructure of the surfactant system under near in vivo conditions, and therefore opens up prospectives for scrutinizing various theories of lamellar body biogenesis, exocytosis and recycling.