897 resultados para gabor filters
Resumo:
We investigate the use of nonlinear optical loop mirrors as saturable absorbers in picosecond soliton transmission systems. It is found that they allow short (1–5-ps) pulses to be propagated through chains of optical amplifiers spaced at intervals of typically 10 km. The loop mirror removes dispersive waves and stabilizes the peak amplitude of the soliton. An additional advantage is that the self-frequency shift of the soliton may be suppressed by bandwidth filtering without causing growth of dispersive waves at the center of the passband. The timing jitter and soliton interactions present in the scheme are also described.
Resumo:
The microwave photonic responses of superstructured fiber Bragg gratings in combination with dispersive fiber are investigated theoretically and experimentally. The superstructured gratings are optimized, taking account of the spectral response of the broad-band source, Erbium-doped fiber amplifier, and optical tunable filter to achieve a filter response with sidelobe suppression of more than 60 dB. © 2004 IEEE.
Resumo:
Gestalt grouping rules imply a process or mechanism for grouping together local features of an object into a perceptual whole. Several psychophysical experiments have been interpreted as evidence for constrained interactions between nearby spatial filter elements and this has led to the hypothesis that element linking might be mediated by these interactions. A common tacit assumption is that these interactions result in response modulation which disturbs a local contrast code. We addressed this possibility by performing contrast discrimination experiments using two-dimensional arrays of multiple Gabor patches arranged either (i) vertically, (ii) in circles (coherent conditions), or (iii) randomly (incoherent condition), as well as for a single Gabor patch. In each condition, contrast increments were applied to either the entire test stimulus (experiment 1) or a single patch whose position was cued (experiment 2). In experiment 3, the texture stimuli were reduced to a single contour by displaying only the central vertical strip. Performance was better for the multiple-patch conditions than for the single-patch condition, but whether the multiple-patch stimulus was coherent or not had no systematic effect on the results in any of the experiments. We conclude that constrained local interactions do not interfere with a local contrast code for our suprathreshold stimuli, suggesting that, in general, this is not the way in which element linking is achieved. The possibility that interactions are involved in enhancing the detectability of contour elements at threshold remains unchallenged by our experiments.
Resumo:
The microwave photonic responses of superstructured fiber Bragg gratings in combination with dispersive fiber are investigated theoretically and experimentally. The superstructured gratings are optimized, taking account of the spectral response of the broad-band source, erbium-doped fiber amplifier, and optical tunable filter to achieve a filter response with sidelobe suppression of more than 60 dB.
Resumo:
We propose and demonstrate single- and multiple-passband fiber grating transmission filters that are remotely tunable by exploitation of the optical pump-induced thermal effects in Er Yb-codoped fiber sections. A repeatable, wavelength-independent induced phase shift of 0.1p mW is obtained without hysteresis and anisotropic effects. A transmission extinction ratio of .23 dB with a 3-mW change in pump power is achieved.
Resumo:
We report all-fiber polarization interference filters, known as Lyot and Lyot-Ohman filters, based on alternative concatenation of UV-inscribed fiber gratings with structure tilted at 45° and polarization maintaining (PM) fiber cavities. Such filters generate comb-like transmission of linear polarization output. The free spectral range (FSR) of a single-stage (Lyot) filter is PM fiber cavity length dependent, as a 20 cm long cavity showed a 26.6 nm FSR while the 40 cm one exhibited a 14.8 nm FSR. Furthermore, we have theoretically and experimentally demonstrated all-fiber 2-stage and 3-stage Lyot-Ohman filters, giving more freedom in tailoring the transmission characteristics.
Resumo:
The suitability of a new plastic supporting medium for biofiltration was tested over a three year period. Tests were carried out on the stability, surface properties, mechanical strength, and dimensions of the medium. There was no evidence to suggest that the medium was deficient in any of these respects. The specific surface (320m2m-3) and the voidage (94%) of the new medium are unlike any other used in bio-filtration and a pilot plant containing two filters was built to observe its effects on ecology and performance. Performance was estimated by chemical analysis and ecology studied by film examination and fauna counts. A system of removable sampling baskets was designed to enable samples to be obtained from two intermediate depths of filter. One of the major operating problems of percolating filters is excessive accumulation of film. The amount of film is influenced by hydraulic and organic load and each filter was run at a different loading. One was operated at 1.2m3m-3day-1 (DOD load 0.24kgm-3day-1) judged at the time to be the lowest filtration rate to offer advantages over conventional media. The other filter was operated at more than twice this loading (2.4m3m-3day-lBOD load 0.55kgm-3day-1) giving a roughly 2.5x and 6x the conventional loadings recommended for a Royal Commission effluent. The amount of film in each filter was normally low (0.05-3kgm(3 as volatile solids) and did not affect efficiency. The evidence collected during the study indicated that the ecology of the filters was normal when compared with the data obtained from the literature relating to filters with mineral media. There were indications that full ecological stability was yet to be reached and this was affecting the efficiency of the filters. The lower rate filter produced an average 87% BOD removal giving a consistent Royal Commission effluent during the summer months. The higher rate filter produced a mean 83% BOD removal but at no stage a consistent Royal Commission effluent. From the data on ecology and performance the filters resembled conventional filters rather than high rate filters.
Resumo:
Pilot scale studies of high rate filtration were initiated to assess its potential as either a primary 'roughing' filter to alleviate the seasonal overloading of low rate filters on Hereford sewage treatment works - caused by wastes from cider production - or as a two stage high rate process to provide complete sewage treatment. Four mineral and four plastic primary filter media and two plastic secondary filter media were studied. The hydraulic loading applied to the primary plastic media (11.2 m3 /m3 .d) was twice that applied to the mineral media. The plastic media removed an average around 66 percent and the mineral media around 73 percent of the BOD applied when the 90 percentile BOD concentration was 563 mg/1. At a hydraulic loading of 4 m3 /m3 .d the secondary filters removed most of the POD from partially settled primary filter effluents, with one secondary effluent satisfying a 25 mg/1 BOD and 30 mg/1 SS standard. No significant degree of nitrification was achieved. Fungi dominated the biological film of the primary filters, with invertebrate grazers having little influence on film levels. Ponding did not arise, and modular media supported lower film levels than random-fill types. Secondary filter film levels were low, being dominated by bacteria. The biological loading applied to the filters was related to sludge dewaterability, with the most readily conditionable sludges produced by filters supporting heavy film. Sludges produced by random-fill media could be dewatered as readily as those produced by low rate filters treating the same sewage. Laboratory scale studies showed a relationship between log effluent BOD and nitrification achieved by biological filters. This relationship and the relationship between BOD load applied and removed observed in all filter media could he used to optimise operating conditions required in biological filters to achieve given effluent BOD and ammoniacal nitrogen standards.
Resumo:
Background Yellow filters are sometimes recommended to people with low vision. Our aim was investigate the effects of three commercial yellow filters on visual acuity and contrast sensitivity (with and without glare) and reading (without glare) under conditions of forward light scatter (FLS). Method Fifty-five healthy subjects were assessed with Corning Photochromic Filters (CPFs) 450, 511 and 527 and a filter producing FLS. The effects on log MAR visual acuity, Pelli–Robson contrast sensitivity with and without glare, and reading (measured with MNRead charts) without glare were determined. Results Statistically significant differences were found between the overall effect of glare and between CPFs for visual acuity and contrast sensitivity. A gradual decline in visual acuity, contrast sensitivity and reading with increasing CPF absorption was noted. Conclusion Effects of CPF450, 511, 527 on visual acuity, contrast sensitivity and reading under conditions of FLS were negative but not clinically significant.
Resumo:
This paper presents a new method for human face recognition by utilizing Gabor-based region covariance matrices as face descriptors. Both pixel locations and Gabor coefficients are employed to form the covariance matrices. Experimental results demonstrate the advantages of this proposed method.
Resumo:
Visual stress is a condition characterised by symptoms of eyestrain, headaches and distortions of visual perception when reading text. The symptoms are frequently alleviated with spectral filters and precision tinted ophthalmic lenses. Visual stress is thought to arise due to cortical hyperexcitability and is associated with a range of neurological conditions. Cortical hyperexcitability is known to occur following stroke. The case presented describes visual stress symptoms resulting from stroke, subsequently managed with spectral filters and precision tinted ophthalmic lenses. The case also highlights that the spectral properties of the tint may need to be modified if the disease course alters.