920 resultados para espectroscopia de impedância


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, it was developed and validated methodologies that were based on the use of Infrared Spectroscopy Mid (MIR) combined with multivariate calibration Square Partial Least (PLS) to quantify adulterants such as soybean oil and residual soybean oil in methyl and ethyl palm biodiesels in the concentration range from 0.25 to 30.00 (%), as well as to determine methyl and ethyl palm biodiesel content in their binary mixtures with diesel in the concentration range from 0.25 to 30.00 (%). The prediction results showed that PLS models constructed are satisfactory. Errors Mean Square Forecast (RMSEP) of adulteration and content determination showed values of 0.2260 (%), with mean error (EM) with values below 1.93 (%). The models also showed a strong correlation between actual and predicted values, staying above 0.99974. No systematic errors were observed, in accordance to ASTM E1655- 05. Thus the built PLS models, may be a promising alternative in the quality control of this fuel for possible adulterations or to content determination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biodiesel is a renewable fuel derived from vegetable oils or animal fats, which can be a total or partial substitute for diesel. Since 2005, this fuel was introduced in the Brazilian energy matrix through Law 11.097 that determines the percentage of biodiesel added to diesel oil as well as monitoring the insertion of this fuel in market. The National Agency of Petroleum, Natural Gas and Biofuels (ANP) establish the obligation of adding 7% (v/v) of biodiesel to diesel commercialized in the country, making crucial the analytical control of this content. Therefore, in this study were developed and validated methodologies based on the use of Mid Infrared Spectroscopy (MIR) and Multivariate Calibration by Partial Least Squares (PLS) to quantify the methyl and ethyl biodiesels content of cotton and jatropha in binary blends with diesel at concentration range from 1.00 to 30.00% (v/v), since this is the range specified in standard ABNT NBR 15568. The biodiesels were produced from two routes, using ethanol or methanol, and evaluated according to the parameters: oxidative stability, water content, kinematic viscosity and density, presenting results according to ANP Resolution No. 45/2014. The built PLS models were validated on the basis of ASTM E1655-05 for Infrared Spectroscopy and Multivariate Calibration and ABNT NBR 15568, with satisfactory results due to RMSEP (Root Mean Square Error of Prediction) values below 0.08% (<0.1%), correlation coefficients (R) above 0.9997 and the absence of systematic error (bias). Therefore, the methodologies developed can be a promising alternative in the quality control of this fuel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Se investiga la concentración de cationes (Ca,Fe,K,Mg),en el frijol negro,(Phaseolus vulgaris L. var. Tineco), usando un analizador de absorción atómica. Para tal efecto se procede a secar la muestra y luego se digiere en un medio acido. Se preparan las soluciones standard correspondiente a los cationes que se quiere investigar y luego se comparan estas concentraciones con las concentraciones de los iones en la muestra. El cálculo de la concentración (desconocida), de los cationes en la muestra, se hace por medio de simple aritmética. En este trabajo se reporta la cantidad en p. p. m. de los elementos arriba mencionados, presente en un gramo de la muestra original. Los resultados obtenidos fueron: Fe = 337.5 p. p. m. ; Ca = 150 p. p. m. ; Mg = 150 p. p. m. y K = 4X104p. p. m.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho descreve um estudo sobre a metodologia matemática para a solução do problema direto e inverso na Tomografia por Impedância Elétrica. Este estudo foi motivado pela necessidade de compreender o problema inverso e sua utilidade na formação de imagens por Tomografia por Impedância Elétrica. O entendimento deste estudo possibilitou constatar, através de equações e programas, a identificação das estruturas internas que constituem um corpo. Para isto, primeiramente, é preciso conhecer os potencias elétricos adquiridos nas fronteiras do corpo. Estes potenciais são adquiridos pela aplicação de uma corrente elétrica e resolvidos matematicamente pelo problema direto através da equação de Laplace. O Método dos Elementos Finitos em conjunção com as equações oriundas do eletromagnetismo é utilizado para resolver o problema direto. O software EIDORS, contudo, através dos conceitos de problema direto e inverso, reconstrói imagens de Tomografia por Impedância Elétrica que possibilitam visualizar e comparar diferentes métodos de resolução do problema inverso para reconstrução de estruturas internas. Os métodos de Tikhonov, Noser, Laplace, Hiperparamétrico e Variação Total foram utilizados para obter uma solução aproximada (regularizada) para o problema de identificação. Na Tomografia por Impedância Elétrica, com as condições de contorno preestabelecidas de corrente elétricas e regiões definidas, o método hiperparamétrico apresentou uma solução aproximada mais adequada para reconstrução da imagem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering the social and economic importance that the milk has, the objective of this study was to evaluate the incidence and quantifying antimicrobial residues in the food. The samples were collected in dairy industry of southwestern Paraná state and thus they were able to cover all ten municipalities in the region of Pato Branco. The work focused on the development of appropriate models for the identification and quantification of analytes: tetracycline, sulfamethazine, sulfadimethoxine, chloramphenicol and ampicillin, all antimicrobials with health interest. For the calibration procedure and validation of the models was used the Infrared Spectroscopy Fourier Transform associated with chemometric method based on Partial Least Squares regression (PLS - Partial Least Squares). To prepare a work solution antimicrobials, the five analytes of interest were used in increasing doses, namely tetracycline from 0 to 0.60 ppm, sulfamethazine 0 to 0.12 ppm, sulfadimethoxine 0 to 2.40 ppm chloramphenicol 0 1.20 ppm and ampicillin 0 to 1.80 ppm to perform the work with the interest in multiresidues analysis. The performance of the models constructed was evaluated through the figures of merit: mean square error of calibration and cross-validation, correlation coefficients and offset performance ratio. For the purposes of applicability in this work, it is considered that the models generated for Tetracycline, Sulfadimethoxine and Chloramphenicol were considered viable, with the greatest predictive power and efficiency, then were employed to evaluate the quality of raw milk from the region of Pato Branco . Among the analyzed samples by NIR, 70% were in conformity with sanitary legislation, and 5% of these samples had concentrations below the Maximum Residue permitted, and is also satisfactory. However 30% of the sample set showed unsatisfactory results when evaluating the contamination with antimicrobials residues, which is non conformity related to the presence of antimicrobial unauthorized use or concentrations above the permitted limits. With the development of this work can be said that laboratory tests in the food area, using infrared spectroscopy with multivariate calibration was also good, fast in analysis, reduced costs and with minimum generation of laboratory waste. Thus, the alternative method proposed meets the quality concerns and desired efficiency by industrial sectors and society in general.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The routine analysis for quantization of organic acids and sugars are generally slow methods that involve the use and preparation of several reagents, require trained professional, the availability of special equipment and is expensive. In this context, it has been increasing investment in research whose purpose is the development of substitutive methods to reference, which are faster, cheap and simple, and infrared spectroscopy have been highlighted in this regard. The present study developed multivariate calibration models for the simultaneous and quantitative determination of ascorbic acid, citric, malic and tartaric and sugars sucrose, glucose and fructose, and soluble solids in juices and fruit nectars and classification models for ACP. We used methods of spectroscopy in the near infrared (Near Infrared, NIR) in association with the method regression of partial least squares (PLS). Were used 42 samples between juices and fruit nectars commercially available in local shops. For the construction of the models were performed with reference analysis using high-performance liquid chromatography (HPLC) and refractometry for the analysis of soluble solids. Subsequently, the acquisition of the spectra was done in triplicate, in the spectral range 12500 to 4000 cm-1. The best models were applied to the quantification of analytes in study on natural juices and juice samples produced in the Paraná Southwest Region. The juices used in the application of the models also underwent physical and chemical analysis. Validation of chromatographic methodology has shown satisfactory results, since the external calibration curve obtained R-square value (R2) above 0.98 and coefficient of variation (%CV) for intermediate precision and repeatability below 8.83%. Through the Principal Component Analysis (PCA) was possible to separate samples of juices into two major groups, grape and apple and tangerine and orange, while for nectars groups separated guava and grape, and pineapple and apple. Different validation methods, and pre-processes that were used separately and in combination, were obtained with multivariate calibration models with average forecast square error (RMSEP) and cross validation (RMSECV) errors below 1.33 and 1.53 g.100 mL-1, respectively and R2 above 0.771, except for malic acid. The physicochemical analysis enabled the characterization of drinks, including the pH working range (variation of 2.83 to 5.79) and acidity within the parameters Regulation for each flavor. Regression models have demonstrated the possibility of determining both ascorbic acids, citric, malic and tartaric with successfully, besides sucrose, glucose and fructose by means of only a spectrum, suggesting that the models are economically viable for quality control and product standardization in the fruit juice and nectars processing industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação (Mestrado em Tecnologia Nuclear)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plasma process like ionic nitriding and cathodic cage plasma nitriding are utilized in order to become hard surface of steels. The ionic nitriding is already accepted in the industry while cathodic cage plasma nitriding process is in industrial implementation stage. Those process depend of plasma parameters like electronic and ionic temperature (Te, Ti), species density (ne, ni) and of distribution function of these species. In the present work, the plasma used to those two processes has been observed through Optical Emission Spectroscopy OES technique in order to identify presents species in the treatment ambient and relatively quantify them. So plasma of typical mixtures like N2 H2 has been monitored through in order to study evolution of those species during the process. Moreover, it has been realized a systematic study about leaks, also thought OES, that accomplish the evolution of contaminant species arising because there is flux of atmosphere to inside nitriding chamber and in what conditions the species are sufficiently reduced. Finally, to describe the physic mechanism that acts on both coating techniques ionic nitriding and cathodic cage plasma nitriding

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com o objetivo de diminuir a incidência das leveduras encapsulas em alginato se aglomerarem na segunda fermentação em garrafa e reduzir custos associados à sua eliminação, pretendeu-se utilizar a metodologia NIR para determinar a quantidade de cálcio no vinho. Foram quantificados outros minerais para avaliar hipotéticos antagonismos iónicos. Observou-se também que este controlo de qualidade poderá ser efetuado no mosto. Atualmente este controlo é realizado por metodologias de análise de referência bastante morosas como EAA. Contudo a metodologia NIR demonstrou ser uma boa alternativa no controlo dos parâ-metros de qualidade na produção de vinho espumante, permitindo a diminuição do tempo de análise e de resíduos. No desenvolvimento dos modelos matemáticos para a calibração do NIR utilizaram-se 79 vinhos brancos e 60 amostras de mosto. Foram desenvolvidos 11 modelos de calibração onde o coeficiente de correlação foi, em aproximadamente 58% dos casos, maior que 0,99; ABSTRACT: In order to reduce the incidence of alginate beads aggregation during the second fermentation in the bottle and to reduce costs associated with their disposal, it was used the NIR technology to quantify calcium content in the wine. Other minerals were also quantified in order to evaluate possible ionic antagonisms. Quality control is usually done in the base wine but it can also be evaluated in the must. Currently this control was carried out by reference analysis methodologies generally rather slow as AAS. However NIR proved to be a good alternative technique in the control of quality parameters of wine production, allowing the reduction of the analysis time and waste. In order to develop mathematical models for the calibration of NIR it was used 79 white wine samples and 60 must samples. Eleven calibration models have been developed, where the correlation coeffi-cient was, in approximately 58% of cases, greater than 0,99.