253 resultados para embolization
Resumo:
This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). It addresses the diagnosis and management of nonvariceal upper gastrointestinal hemorrhage (NVUGIH). Main Recommendations MR1. ESGE recommends immediate assessment of hemodynamic status in patients who present with acute upper gastrointestinal hemorrhage (UGIH), with prompt intravascular volume replacement initially using crystalloid fluids if hemodynamic instability exists (strong recommendation, moderate quality evidence). MR2. ESGE recommends a restrictive red blood cell transfusion strategy that aims for a target hemoglobin between 7 g/dL and 9 g/dL. A higher target hemoglobin should be considered in patients with significant co-morbidity (e. g., ischemic cardiovascular disease) (strong recommendation, moderate quality evidence). MR3. ESGE recommends the use of the Glasgow-Blatchford Score (GBS) for pre-endoscopy risk stratification. Outpatients determined to be at very low risk, based upon a GBS score of 0 - 1, do not require early endoscopy nor hospital admission. Discharged patients should be informed of the risk of recurrent bleeding and be advised to maintain contact with the discharging hospital (strong recommendation, moderate quality evidence). MR4. ESGE recommends initiating high dose intravenous proton pump inhibitors (PPI), intravenous bolus followed by continuous infusion (80 mg then 8 mg/hour), in patients presenting with acute UGIH awaiting upper endoscopy. However, PPI infusion should not delay the performance of early endoscopy (strong recommendation, high quality evidence). MR5. ESGE does not recommend the routine use of nasogastric or orogastric aspiration/lavage in patients presenting with acute UGIH (strong recommendation, moderate quality evidence). MR6. ESGE recommends intravenous erythromycin (single dose, 250 mg given 30 - 120 minutes prior to upper gastrointestinal [GI] endoscopy) in patients with clinically severe or ongoing active UGIH. In selected patients, pre-endoscopic infusion of erythromycin significantly improves endoscopic visualization, reduces the need for second-look endoscopy, decreases the number of units of blood transfused, and reduces duration of hospital stay (strong recommendation, high quality evidence). MR7. Following hemodynamic resuscitation, ESGE recommends early (≤ 24 hours) upper GI endoscopy. Very early (< 12 hours) upper GI endoscopy may be considered in patients with high risk clinical features, namely: hemodynamic instability (tachycardia, hypotension) that persists despite ongoing attempts at volume resuscitation; in-hospital bloody emesis/nasogastric aspirate; or contraindication to the interruption of anticoagulation (strong recommendation, moderate quality evidence). MR8. ESGE recommends that peptic ulcers with spurting or oozing bleeding (Forrest classification Ia and Ib, respectively) or with a nonbleeding visible vessel (Forrest classification IIa) receive endoscopic hemostasis because these lesions are at high risk for persistent bleeding or rebleeding (strong recommendation, high quality evidence). MR9. ESGE recommends that peptic ulcers with an adherent clot (Forrest classification IIb) be considered for endoscopic clot removal. Once the clot is removed, any identified underlying active bleeding (Forrest classification Ia or Ib) or nonbleeding visible vessel (Forrest classification IIa) should receive endoscopic hemostasis (weak recommendation, moderate quality evidence). MR10. In patients with peptic ulcers having a flat pigmented spot (Forrest classification IIc) or clean base (Forrest classification III), ESGE does not recommend endoscopic hemostasis as these stigmata present a low risk of recurrent bleeding. In selected clinical settings, these patients may be discharged to home on standard PPI therapy, e. g., oral PPI once-daily (strong recommendation, moderate quality evidence). MR11. ESGE recommends that epinephrine injection therapy not be used as endoscopic monotherapy. If used, it should be combined with a second endoscopic hemostasis modality (strong recommendation, high quality evidence). MR12. ESGE recommends PPI therapy for patients who receive endoscopic hemostasis and for patients with adherent clot not receiving endoscopic hemostasis. PPI therapy should be high dose and administered as an intravenous bolus followed by continuous infusion (80 mg then 8 mg/hour) for 72 hours post endoscopy (strong recommendation, high quality evidence). MR13. ESGE does not recommend routine second-look endoscopy as part of the management of nonvariceal upper gastrointestinal hemorrhage (NVUGIH). However, in patients with clinical evidence of rebleeding following successful initial endoscopic hemostasis, ESGE recommends repeat upper endoscopy with hemostasis if indicated. In the case of failure of this second attempt at hemostasis, transcatheter angiographic embolization (TAE) or surgery should be considered (strong recommendation, high quality evidence). MR14. In patients with NVUGIH secondary to peptic ulcer, ESGE recommends investigating for the presence of Helicobacter pylori in the acute setting with initiation of appropriate antibiotic therapy when H. pylori is detected. Re-testing for H. pylori should be performed in those patients with a negative test in the acute setting. Documentation of successful H. pylori eradication is recommended (strong recommendation, high quality evidence). MR15. In patients receiving low dose aspirin for secondary cardiovascular prophylaxis who develop peptic ulcer bleeding, ESGE recommends aspirin be resumed immediately following index endoscopy if the risk of rebleeding is low (e. g., FIIc, FIII). In patients with high risk peptic ulcer (FIa, FIb, FIIa, FIIb), early reintroduction of aspirin by day 3 after index endoscopy is recommended, provided that adequate hemostasis has been established (strong recommendation, moderate quality evidence).
Resumo:
Recombinant activated factor VII (rFVIIa) is a powerful hemostatic agent developed for use in hemophilia. It has been used increasingly in life-threatening hemorrhage in a variety of other settings in which conventional medical or surgical therapy is unsuccessful. This report describes the successful use of rFVIIa for pulmonary hemorrhage due to a focal bleeding source in a regional hospital where bronchial artery embolization or surgery were not available. rFVIIa may be a useful temporizing measure in the unstable patient with pulmonary hemorrhage without coagulopathic bleeding when conventional treatment. is not immediately available.
Resumo:
The objective of this study was to gain further understanding and elucidation of the fluid dynamic factors and flow-induced mechanisms of the thrombogenic process of platelet deposition onto, and possible subsequent embolization from, the walls of an arterial stenosis. This has been accomplished by measurement of the axial dependence of platelet deposition within a modeled arterial stenosis for a transitional flow and a completely laminar flow field. The stenotic region of the model was collagen-coated to simulate a damaged endothelial lining of an artery. Fluid dynamics within a stenosis was studied using qualitative flow visualization, and was further compared to the in vitro platelet deposition studies. Normalized platelet density (NPD) measurements indicate decreased levels of NPD in the high shear throat region of the stenosis for a Reynolds number of 300 and a drastic increase in NPD at the throat for a Reynolds number of 175. This study provides further understanding of the flow dynamic effects on thrombus development within a stenosis. ^
Resumo:
Copyright © 2015 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Resumo:
Les maladies cardiovasculaires sont la première cause de mortalité dans le monde et les anévrismes de l’aorte abdominale (AAAs) font partie de ce lot déplorable. Un anévrisme est la dilatation d’une artère pouvant conduire à la mort. Une rupture d’AAA s’avère fatale près de 80% du temps. Un moyen de traiter les AAAs est l’insertion d’une endoprothèse (SG) dans l’aorte, communément appelée la réparation endovasculaire (EVAR), afin de réduire la pression exercée par le flux sanguin sur la paroi. L’efficacité de ce traitement est compromise par la survenue d’endofuites (flux sanguins entre la prothèse et le sac anévrismal) pouvant conduire à la rupture de l’anévrisme. Ces flux sanguins peuvent survenir à n’importe quel moment après le traitement EVAR. Une surveillance par tomodensitométrie (CT-scan) annuelle est donc requise, augmentant ainsi le coût du suivi post-EVAR et exposant le patient à la radiation ionisante et aux complications des contrastes iodés. L’endotension est le concept de dilatation de l’anévrisme sans la présence d’une endofuite apparente au CT-scan. Après le traitement EVAR, le sang dans le sac anévrismal coagule pour former un thrombus frais, qui deviendra progressivement un thrombus plus fibreux et plus organisé, donnant lieu à un rétrécissement de l’anévrisme. Il y a très peu de données dans la littérature pour étudier ce processus temporel et la relation entre le thrombus frais et l’endotension. L’étalon d’or du suivi post-EVAR, le CT-scan, ne peut pas détecter la présence de thrombus frais. Il y a donc un besoin d’investir dans une technique sécuritaire et moins coûteuse pour le suivi d’AAAs après EVAR. Une méthode récente, l’élastographie dynamique, mesure l’élasticité des tissus en temps réel. Le principe de cette technique repose sur la génération d’ondes de cisaillement et l’étude de leur propagation afin de remonter aux propriétés mécaniques du milieu étudié. Cette thèse vise l’application de l’élastographie dynamique pour la détection des endofuites ainsi que de la caractérisation mécanique des tissus du sac anévrismal après le traitement EVAR. Ce projet dévoile le potentiel de l’élastographie afin de réduire les dangers de la radiation, de l’utilisation d’agent de contraste ainsi que des coûts du post-EVAR des AAAs. L’élastographie dynamique utilisant le « Shear Wave Imaging » (SWI) est prometteuse. Cette modalité pourrait complémenter l’échographie-Doppler (DUS) déjà utilisée pour le suivi d’examen post-EVAR. Le SWI a le potentiel de fournir des informations sur l’organisation fibreuse du thrombus ainsi que sur la détection d’endofuites. Tout d’abord, le premier objectif de cette thèse consistait à tester le SWI sur des AAAs dans des modèles canins pour la détection d’endofuites et la caractérisation du thrombus. Des SGs furent implantées dans un groupe de 18 chiens avec un anévrisme créé au moyen de la veine jugulaire. 4 anévrismes avaient une endofuite de type I, 13 avaient une endofuite de type II et un anévrisme n’avait pas d’endofuite. Des examens échographiques, DUS et SWI ont été réalisés à l’implantation, puis 1 semaine, 1 mois, 3 mois et 6 mois après le traitement EVAR. Une angiographie, un CT-scan et des coupes macroscopiques ont été produits au sacrifice. Les régions d’endofuites, de thrombus frais et de thrombus organisé furent identifiées et segmentées. Les valeurs de rigidité données par le SWI des différentes régions furent comparées. Celles-ci furent différentes de façon significative (P < 0.001). Également, le SWI a pu détecter la présence d’endofuites où le CT-scan (1) et le DUS (3) ont échoué. Dans la continuité de ces travaux, le deuxième objectif de ce projet fut de caractériser l’évolution du thrombus dans le temps, de même que l’évolution des endofuites après embolisation dans des modèles canins. Dix-huit anévrismes furent créés dans les artères iliaques de neuf modèles canins, suivis d’une endofuite de type I après EVAR. Deux gels embolisants (Chitosan (Chi) ou Chitosan-Sodium-Tetradecyl-Sulfate (Chi-STS)) furent injectés dans le sac anévrismal pour promouvoir la guérison. Des examens échographiques, DUS et SWI ont été effectués à l’implantation et après 1 semaine, 1 mois, 3 mois et 6 mois. Une angiographie, un CT-scan et un examen histologique ont été réalisés au sacrifice afin d’évaluer la présence, le type et la grosseur de l’endofuite. Les valeurs du module d’élasticité des régions d’intérêts ont été identifiées et segmentées sur les données pathologiques. Les régions d’endofuites et de thrombus frais furent différentes de façon significative comparativement aux autres régions (P < 0.001). Les valeurs d’élasticité du thrombus frais à 1 semaine et à 3 mois indiquent que le SWI peut évaluer la maturation du thrombus, de même que caractériser l’évolution et la dégradation des gels embolisants dans le temps. Le SWI a pu détecter des endofuites où le DUS a échoué (2) et, contrairement au CT-scan, détecter la présence de thrombus frais. Finalement, la dernière étape du projet doctoral consistait à appliquer le SWI dans une phase clinique, avec des patients humains ayant déjà un AAA, pour la détection d’endofuite et la caractérisation de l’élasticité des tissus. 25 patients furent sélectionnés pour participer à l’étude. Une comparaison d’imagerie a été produite entre le SWI, le CT-scan et le DUS. Les valeurs de rigidité données par le SWI des différentes régions (endofuite, thrombus) furent identifiées et segmentées. Celles-ci étaient distinctes de façon significative (P < 0.001). Le SWI a détecté 5 endofuites sur 6 (sensibilité de 83.3%) et a eu 6 faux positifs (spécificité de 76%). Le SWI a pu détecter la présence d’endofuites où le CT-scan (2) ainsi que le DUS (2) ont échoué. Il n’y avait pas de différence statistique notable entre la rigidité du thrombus pour un AAA avec endofuite et un AAA sans endofuite. Aucune corrélation n’a pu être établie de façon significative entre les diamètres des AAAs ainsi que leurs variations et l’élasticité du thrombus. Le SWI a le potentiel de détecter les endofuites et caractériser le thrombus selon leurs propriétés mécaniques. Cette technique pourrait être combinée au suivi des AAAs post-EVAR, complémentant ainsi l’imagerie DUS et réduisant le coût et l’exposition à la radiation ionisante et aux agents de contrastes néphrotoxiques.
Resumo:
Aim. We report a case of ulnar and palmar arch artery aneurysm in a 77 years old man without history of any occupational or recreational trauma, vasculitis, infections or congenital anatomic abnormalities. We also performed a computed search of literature in PUBMED using the keywords “ulnar artery aneurysm” and “palmar arch aneurysm”. Case report. A 77 years old male patient was admitted to hospital with a pulsing mass at distal right ulnar artery and deep palmar arch; at ultrasound and CT examination a saccular aneurysm of 35 millimeters at right ulnar artery and a 15 millimeters dilatation at deep palmar arch were detected. He was asymptomatic for distal embolization and pain. In local anesthesia ulnar artery and deep palmar arch dilatations were resected. Reconstruction of vessels was performed through an end-to-end microvascular repair. Histological examination confirmed the absence of vasculitis and collagenopaties. In postoperative period there were no clinical signs of peripheral ischemia, Allen’s test and ultrasound examination were normal. At follow-up of six months, the patient was still asymptomatic with a normal Allen test, no signs of distal digital ischemia and patency of treated vessel with normal flow at duplex ultrasound. Conclusion. True spontaneous aneurysms of ulnar artery and palmar arch are rare and can be successfully treated with resection and microvascular reconstruction.
Resumo:
We report a rare case of a 50 year old man with renal squamous cell carcinoma (SCC) who first came to our attention with renal colic and fever not responding to antibiotic or analgesic treatment. He had a long history of kidney stones, but had not undergone any imaging in the last 5 years. Physical examination revealed tenderness and a palpable mass in the right flank and lumbar region. A whole body CT scan was performed, revealing an 11 cm mass in the right kidney infiltrating the inferior vena cava. There were areas of calcification within the mass and multiple stones within the renal pelvis. The tumor was considered unsuitable for resection according to radiological and clinical criteria. The mass was biopsied percutaneously under CT guidance and histological examination revealed squamous cell carcinoma of the renal pelvis. The patient was treated with neoadjuvant chemotherapy and embolization of the renal artery. He died one month after diagnosis. To our knowledge this is the second reported case in the world of renal SCC infiltrating the inferior vena cava and with kidney stones.
Resumo:
Purpose. The present report describes a full endovascular treatment of a multiple anomalous (Splenic artery aneurysms) SAA with combination of coils embolization and proximal occlusion of the splenic artery with the Amplatzer vascular plug. Case report. A 53-year-old Jehovah witness woman presented with multiple aneurysms arising from an anomalous splenic artery. An endovascular treatment was performed by implantation of multiple coils and an Amplatzer Vascular Plug. A CT scan 2 months after the procedure showed complete thrombosis of the aneurysms. Discussion. Aneurysms involving an anomalous or aberrant splenic artery are rarely reported in the literature. Their surgical treatment involves potential difficulties as a consequence of anatomical position and vascular anomalies. A fully endovascular technique can be much more attractive compared to any surgical management, providing an effective and minimally invasive option. Splenic artery - Aberrant splenic artery - Aneurysm - Endovascular treatment - Jehovah witness.
Resumo:
We describe the case of a 68-year-old man, who presented with an ischemic stroke due to cardiac embolization related to mitral valve endocarditis. Blood cultures were always negative and post-operative valve histology did not show microorganisms. The patient also presented further recurrent peripheral embolic events. These clinical aspects were the first sign of a pancreas adenocarcinoma, which was only diagnosed in the clinical autopsy. In conclusion, these clinical findings of recurrent thromboembolic events with no microorganisms isolated suggests the diagnostic of a marantic endocarditis.
Resumo:
Les maladies cardiovasculaires sont la première cause de mortalité dans le monde et les anévrismes de l’aorte abdominale (AAAs) font partie de ce lot déplorable. Un anévrisme est la dilatation d’une artère pouvant conduire à la mort. Une rupture d’AAA s’avère fatale près de 80% du temps. Un moyen de traiter les AAAs est l’insertion d’une endoprothèse (SG) dans l’aorte, communément appelée la réparation endovasculaire (EVAR), afin de réduire la pression exercée par le flux sanguin sur la paroi. L’efficacité de ce traitement est compromise par la survenue d’endofuites (flux sanguins entre la prothèse et le sac anévrismal) pouvant conduire à la rupture de l’anévrisme. Ces flux sanguins peuvent survenir à n’importe quel moment après le traitement EVAR. Une surveillance par tomodensitométrie (CT-scan) annuelle est donc requise, augmentant ainsi le coût du suivi post-EVAR et exposant le patient à la radiation ionisante et aux complications des contrastes iodés. L’endotension est le concept de dilatation de l’anévrisme sans la présence d’une endofuite apparente au CT-scan. Après le traitement EVAR, le sang dans le sac anévrismal coagule pour former un thrombus frais, qui deviendra progressivement un thrombus plus fibreux et plus organisé, donnant lieu à un rétrécissement de l’anévrisme. Il y a très peu de données dans la littérature pour étudier ce processus temporel et la relation entre le thrombus frais et l’endotension. L’étalon d’or du suivi post-EVAR, le CT-scan, ne peut pas détecter la présence de thrombus frais. Il y a donc un besoin d’investir dans une technique sécuritaire et moins coûteuse pour le suivi d’AAAs après EVAR. Une méthode récente, l’élastographie dynamique, mesure l’élasticité des tissus en temps réel. Le principe de cette technique repose sur la génération d’ondes de cisaillement et l’étude de leur propagation afin de remonter aux propriétés mécaniques du milieu étudié. Cette thèse vise l’application de l’élastographie dynamique pour la détection des endofuites ainsi que de la caractérisation mécanique des tissus du sac anévrismal après le traitement EVAR. Ce projet dévoile le potentiel de l’élastographie afin de réduire les dangers de la radiation, de l’utilisation d’agent de contraste ainsi que des coûts du post-EVAR des AAAs. L’élastographie dynamique utilisant le « Shear Wave Imaging » (SWI) est prometteuse. Cette modalité pourrait complémenter l’échographie-Doppler (DUS) déjà utilisée pour le suivi d’examen post-EVAR. Le SWI a le potentiel de fournir des informations sur l’organisation fibreuse du thrombus ainsi que sur la détection d’endofuites. Tout d’abord, le premier objectif de cette thèse consistait à tester le SWI sur des AAAs dans des modèles canins pour la détection d’endofuites et la caractérisation du thrombus. Des SGs furent implantées dans un groupe de 18 chiens avec un anévrisme créé au moyen de la veine jugulaire. 4 anévrismes avaient une endofuite de type I, 13 avaient une endofuite de type II et un anévrisme n’avait pas d’endofuite. Des examens échographiques, DUS et SWI ont été réalisés à l’implantation, puis 1 semaine, 1 mois, 3 mois et 6 mois après le traitement EVAR. Une angiographie, un CT-scan et des coupes macroscopiques ont été produits au sacrifice. Les régions d’endofuites, de thrombus frais et de thrombus organisé furent identifiées et segmentées. Les valeurs de rigidité données par le SWI des différentes régions furent comparées. Celles-ci furent différentes de façon significative (P < 0.001). Également, le SWI a pu détecter la présence d’endofuites où le CT-scan (1) et le DUS (3) ont échoué. Dans la continuité de ces travaux, le deuxième objectif de ce projet fut de caractériser l’évolution du thrombus dans le temps, de même que l’évolution des endofuites après embolisation dans des modèles canins. Dix-huit anévrismes furent créés dans les artères iliaques de neuf modèles canins, suivis d’une endofuite de type I après EVAR. Deux gels embolisants (Chitosan (Chi) ou Chitosan-Sodium-Tetradecyl-Sulfate (Chi-STS)) furent injectés dans le sac anévrismal pour promouvoir la guérison. Des examens échographiques, DUS et SWI ont été effectués à l’implantation et après 1 semaine, 1 mois, 3 mois et 6 mois. Une angiographie, un CT-scan et un examen histologique ont été réalisés au sacrifice afin d’évaluer la présence, le type et la grosseur de l’endofuite. Les valeurs du module d’élasticité des régions d’intérêts ont été identifiées et segmentées sur les données pathologiques. Les régions d’endofuites et de thrombus frais furent différentes de façon significative comparativement aux autres régions (P < 0.001). Les valeurs d’élasticité du thrombus frais à 1 semaine et à 3 mois indiquent que le SWI peut évaluer la maturation du thrombus, de même que caractériser l’évolution et la dégradation des gels embolisants dans le temps. Le SWI a pu détecter des endofuites où le DUS a échoué (2) et, contrairement au CT-scan, détecter la présence de thrombus frais. Finalement, la dernière étape du projet doctoral consistait à appliquer le SWI dans une phase clinique, avec des patients humains ayant déjà un AAA, pour la détection d’endofuite et la caractérisation de l’élasticité des tissus. 25 patients furent sélectionnés pour participer à l’étude. Une comparaison d’imagerie a été produite entre le SWI, le CT-scan et le DUS. Les valeurs de rigidité données par le SWI des différentes régions (endofuite, thrombus) furent identifiées et segmentées. Celles-ci étaient distinctes de façon significative (P < 0.001). Le SWI a détecté 5 endofuites sur 6 (sensibilité de 83.3%) et a eu 6 faux positifs (spécificité de 76%). Le SWI a pu détecter la présence d’endofuites où le CT-scan (2) ainsi que le DUS (2) ont échoué. Il n’y avait pas de différence statistique notable entre la rigidité du thrombus pour un AAA avec endofuite et un AAA sans endofuite. Aucune corrélation n’a pu être établie de façon significative entre les diamètres des AAAs ainsi que leurs variations et l’élasticité du thrombus. Le SWI a le potentiel de détecter les endofuites et caractériser le thrombus selon leurs propriétés mécaniques. Cette technique pourrait être combinée au suivi des AAAs post-EVAR, complémentant ainsi l’imagerie DUS et réduisant le coût et l’exposition à la radiation ionisante et aux agents de contrastes néphrotoxiques.
Resumo:
Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014
Resumo:
Este relatório foi elaborado no âmbito do estágio curricular do Mestrado Integrado em Medicina Veterinária. Encontra-se dividido em duas partes. Na primeira parte é feita uma análise da casuística seguida durante o estágio. A segunda parte é constituída por uma monografia de revisão bibliográfica sobre o tema ”Tromboembolismo Arterial Felino”(TAF), bem como a descrição e discussão de dois casos clínicos acompanhados durante o estágio. O TAF é caracterizado pela embolização de um trombo numa artéria da circulação sistémica, sendo a localização mais frequente a trifurcação ilíaca da artéria aorta. Na maioria dos casos, o trombo tem origem no átrio esquerdo, como resultado de cardiomiopatia. Apesar do diagnóstico ser facilmente obtido através de sinais clínicos, o tratamento e a prevenção desta afeção representam um desafio para o médico veterinário, já que a taxa de reincidência de tromboembolismo e mortalidade são elevadas, projectando um prognóstico reservado; Clinic and Surgery of Small Animals Abstract: This report was done within the scope of the internship integrated master’s degree in Veterinay Medicine. It is divided in two parts. In the first part, an analisys of the casuistic followed during the internship is done. The second part is composed by a literature review about the theme ”Feline Arterial Thromboembolism”(FAT), as well as the description and discussion of two clinical cases followed during the internship. FAT is characterized by the embolization of a thrombus in a artery of systemic circulation, being its location more frequently in iliac trifurcation of aorta artery. On most of the cases the thrombus has its origins on the left atrium, as a result of cardiomyopathy. Besides the diagnosis being easily obtained through clinical signs, the treatment and prevention of this disease represents a challenge to the veterinarian clinician, due to the FAT recurrance rate and high mortality, projecting a pour/reserved prognosis.
Resumo:
Abdominal aortic aneurysm is the pathological dilation of the abdominal tract of the aorta and, if left untreated, could undergo rupture with a mortality rate of up to 90%. EVAR is the most common method for AAA treatment consisting in the internal coverage of the aorta with a metallic stent to isolate the aneurysmatic segment from the systemic circulation. Although EVAR technical success rate is high, reinterventions are common. Among the causes of reinterventions typeII endoleaks are the most frequent and consist in retrograde blood flow into the aneurysmal sac from collateral aortic branches. Continued perfusion of the aneurysm sac may lead to aneurysm rupture, therefore AAA sac embolization is performed using metallic coils. However, the presence of artifacts caused by the presence of metallic coils is a limitation because they are radiopaque and can hamper the endoleak during imaging follow-up. This study is aimed at developing a biocompatible hydrogel that could be injected into the aneurysmal sac and may allow a selective intraprocedural sac embolization to reduce post procedural typeII endoleak and eventual AAA rupture. P(BT75BSI25) was synthesized by polycondensation and its biocompatibility tested to assess whether the polymers had no toxic effects. HUVEC cell line was used to mimic the environment in which the polymer would be in contact with, PBS was used as a positive control and MTT assay was performed to evaluate cellular viability after being in contact with the hydrogel. MTT assay showed no significant difference between PBS and P(BT75BSI25), thus the polymer is biocompatible, as confirmed by the analysis of apoptosis by flow cytometry. An aromatic copolymer was obtained via polycondensation and was found to be biocompatible in contact with endothelial cells. This suggests that the hydrogel could be potentially used in the clinical setting for the treatment of type II endoleak after EVAR.