999 resultados para dynamic decomposition


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methanol decomposition is one of the key reactions in direct methanol fuel cell (DMFC) state-of-the-art technology, research, and development. However, its mechanism still presents many uncertainties, which, if answered, would permit us to refine the manufacture of DMFCs. The mechanism of methanol decomposition on ruthenium surfaces was investigated using density functional theory and a periodic supercell approach. The possible pathways, involving either initial C−H, C−O or O−H scission, were defined from experimental evidence regarding the methanol decomposition on ruthenium and other metallic surfaces. The study yielded the O−H scission pathway as having both the most favorable energetics and kinetics. The computational data, which present a remarkable closeness with the experimental results, also indicate methanol adsorption, the starting point in all possible pathways, to be of weak nature, implying a considerable rate of methanol desorption from the ruthenium, compromising the reaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Container Loading Problem (CLP) literature has traditionally evaluated the dynamic stability of cargo by applying two metrics to box arrangements: the mean number of boxes supporting the items excluding those placed directly on the floor (M1) and the percentage of boxes with insufficient lateral support (M2). However, these metrics, that aim to be proxies for cargo stability during transportation, fail to translate real-world cargo conditions of dynamic stability. In this paper two new performance indicators are proposed to evaluate the dynamic stability of cargo arrangements: the number of fallen boxes (NFB) and the number of boxes within the Damage Boundary Curve fragility test (NB_DBC). Using 1500 solutions for well-known problem instances found in the literature, these new performance indicators are evaluated using a physics simulation tool (StableCargo), replacing the real-world transportation by a truck with a simulation of the dynamic behaviour of container loading arrangements. Two new dynamic stability metrics that can be integrated within any container loading algorithm are also proposed. The metrics are analytical models of the proposed stability performance indicators, computed by multiple linear regression. Pearson’s r correlation coefficient was used as an evaluation parameter for the performance of the models. The extensive computational results show that the proposed metrics are better proxies for dynamic stability in the CLP than the previous widely used metrics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of our study was to evaluate the accuracy of dynamic incremental bolus-enhanced conventional CT (DICT) with intravenous contrast administration, early phase, in the diagnosis of malignancy of focal liver lesions. A total of 122 lesions were selected in 74 patients considering the following criteria: lesion diameter 10 mm or more, number of lesions less than six per study, except in multiple angiomatosis and the existence of a valid criteria of definitive diagnosis. Lesions were categorized into seven levels of diagnostic confidence of malignancy compared with the definitive diagnosis for acquisition of a receiver-operator-characteristic (ROC) curve analysis and to determine the sensitivity and specificity of the technique. Forty-six and 70 lesions were correctly diagnosed as malignant and benign, respectively; there were 2 false-positive and 4 false-negative diagnoses of malignancy and the sensitivity and specificity obtained were 92 and 97%. The DICT early phase was confirmed as a highly accurate method in the characterization and diagnosis of malignancy of focal liver lesions, requiring an optimal technical performance and judicious analysis of existing semiological data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have studied the cardiac chronotropic responses to the Valsalva maneuver and to dynamic exercise of twenty chronic chagasic patients with normal left ventricular function and no segmental wall abnormalities by two-dimensional echocardiogram. The absolute increase in heart rate of the patients (Δ = 21.5 ± 10 bpm, M±SD) during the maneuver was significantly diminished when compared to controls (Δ = 31.30 ± 70, M±SD, p = 0.03). The minimum heart rate (58.24 ± 8.90 vs. 62.80 ± 10, p = 0.68) and the absolute decrease in heart rate at the end of the maneuver (Δ = 38.30 ± 13 vs. Δ = 31.47 ± 17, p = 0.10) were not different from controls. The initial heart rate acceleration during dynamic exercise (Δ = 12 ± 7.55 vs. Δ = 19 ± 7.27, M±SD, p = 0.01) was also diminished, but the heart rate recovery during the first ten seconds was more prominent in the sero-positive patients (Median: 14, Interquartile range: (9.75-17.50 vs. 5(0-8.75, p = 0.001). The serum levels of muscarinic cardiac auto-antibodies were significantly higher in the chagasic patients (Median: 34.58, Interquartile Range: 17-46.5, Optical Density) than in controls (Median: 0, Interquartile Range: 0-22.25, p = 0.001) and correlated significantly and directly (r = 0.68, p = 0.002) with early heart rate recovery during dynamic exercise. The results of this investigation indirectly suggest that, the cardiac muscarinic auto-antibodies may have positive agonist effects on parasympathetic heart rate control of chagasic patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Gelastic seizures are a frequent and well established manifestation of the epilepsy associated with hypothalamic hamartomas. The scalp EEG recordings very seldom demonstrate clear spike activity and the information about the ictal epilepsy dynamics is limited. In this work, we try to isolate epileptic rhythms in gelastic seizures and study their generators. Methods: We extracted rhythmic activity from EEG scalp recordings of gelastic seizures using decomposition in independent components (ICA) in three patients, two with hypothalamic hamartomas and one with no hypothalamic lesion. Time analysis of these rhythms and inverse source analysis was done to recover their foci of origin and temporal dynamics. Results: In the two patients with hypothalamic hamartomas consistent ictal delta (2–3 Hz) rhythms were present, with subcortical generators in both and a superficial one in a single patient. The latter pattern was observed in the patient with no hypothalamic hamartoma visible in MRI. The deep generators activated earlier than the superficial ones, suggesting a consistent sub-cortical origin of the rhythmical activity. Conclusions: Our data is compatible with early and brief epileptic generators in deep sub-cortical regions and more superficial ones activating later. Significance: Gelastic seizures express rhythms on scalp EEG compatible with epileptic activity originating in sub-cortical generators and secondarily involving cortical ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Civil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain the Ph.D degree in Biology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Canine brains infected with rabies virus were submitted to decomposition by being left at room temperature of 25 to 29oC for up to 168h. At 24h intervals, brain fragments were analyzed by immunofluorescence (IF) and by the mouse intracerebral inoculation (MI) test to confirm the diagnosis of rabies and to measure the putrefaction effect on the accuracy of the diagnosis. Forty eight h after the beginning of the experiment, the MI test showed signs of impairment with four negative results, while after 72h, 100% of the results were negative to the MI test and only one result was negative to the IF test, indicating that the threshold period for accurate diagnosis is 24 to 48h before putrefaction. The authors recommend the shipment of suspected cases of rabies to the laboratory for confirmation, but the use of putrid materials for diagnosis is meaningless because of false-negative results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Informática

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Informática