934 resultados para corneal oedema


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate distance and near image quality after hybrid bi-aspheric multifocal central presbyLASIK treatments. Design: Consecutive case series. Methods: Sixty-four eyes of 32 patients consecutively treated with central presbyLASIK were assessed. The mean age of the patients was 51 ± 3 years with a mean spherical equivalent refraction of-1.08 ± 2.62 diopters (D) and mean astigmatism of 0.52 ± 0.42 D. Monocular corrected distance visual acuity (CDVA), corrected near visual acuity (CNVA), and distance corrected near visual acuity (DCNVA) of nondominant eyes; binocular uncorrected distance visual acuity (UDVA); uncorrected intermediate visual acuity (UIVA); distance corrected intermediate visual acuity (DCIVA); and uncorrected near visual acuity (UNVA) were assessed pre- and postoperatively. Subjective quality of vision and near vision was assessed using the 10-item Rasch-scaled Quality of Vision and Near Activity Visual Questionnaire, respectively. Results: At 1 year postoperatively, 93% of patients achieved 20/20 or better binocular UDVA; 90% and 97% of patients had J2 or better UNVA and UIVA, respectively; 7% lost 2 Snellen lines of CDVA; Strehl ratio reduced by ~-4% ± 14%. Defocus curves revealed a loss of half a Snellen line at best focus, with no change for intermediate vergence (-1.25 D) and a mean gain of 2 lines for near vergence (-3 D). Conclusions: Presbyopic treatment using a hybrid bi-aspheric micro-monovision ablation profile is safe and efficacious. The postoperative outcomes indicate improvements in binocular vision at far, intermediate, and near distances with improved contrast sensitivity. A 19% retreatment rate should be considered to increase satisfaction levels, besides a 3% reversal rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/aims: Retinal screening programmes in England and Scotland have similar photographic grading schemes for background (non-proliferative) and proliferative diabetic retinopathy, but diverge over maculopathy. We looked for the most cost-effective method of identifying diabetic macular oedema from retinal photographs including the role of automated grading and optical coherence tomography, a technology that directly visualises oedema. Methods: Patients from seven UK centres were recruited. The following features in at least one eye were required for enrolment: microaneurysms/dot haemorrhages or blot haemorrhages within one disc diameter, or exudates within one or two disc diameters of the centre of the macula. Subjects had optical coherence tomography and digital photography. Manual and automated grading schemes were evaluated. Costs and QALYs were modelled using microsimulation techniques. Results: 3540 patients were recruited, 3170 were analysed. For diabetic macular oedema, England's scheme had a sensitivity of 72.6% and specificity of 66.8%; Scotland 's had a sensitivity of 59.5% and specificity of 79.0%. When applying a ceiling ratio of £30 000 per quality adjusted life years (QALY) gained, Scotland's scheme was preferred. Assuming automated grading could be implemented without increasing grading costs, automation produced a greater number of QALYS for a lower cost than England's scheme, but was not cost effective, at the study's operating point, compared with Scotland's. The addition of optical coherence tomography, to each scheme, resulted in cost savings without reducing health benefits. Conclusions: Retinal screening programmes in the UK should reconsider the screening pathway to make best use of existing and new technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To determine the best photographic surrogate markers for detecting sight-threatening macular oedema (MO) in people with diabetes attending UK national screening programmes. Design: A multicentre, prospective, observational cohort study of 3170 patients with photographic signs of diabetic retinopathy visible within the macular region [exudates within two disc diameters, microaneurysms/dot haemorrhages (M/DHs) and blot haemorrhages (BHs)] who were recruited from seven study centres. Setting: All patients were recruited and imaged at one of seven study centres in Aberdeen, Birmingham, Dundee, Dunfermline, Edinburgh, Liverpool and Oxford. Participants: Subjects with features of diabetic retinopathy visible within the macular region attending one of seven diabetic retinal screening programmes. Interventions: Alternative referral criteria for suspected MO based on photographic surrogate markers; an optical coherence tomographic examination in addition to the standard digital retinal photograph. Main outcome measures: (1) To determine the best method to detect sight-threatening MO in people with diabetes using photographic surrogate markers. (2) Sensitivity and specificity estimates to assess the costs and consequences of using alternative strategies. (3) Modelled long-term costs and quality-adjusted life-years (QALYs). Results: Prevalence of MO was strongly related to the presence of lesions and was roughly five times higher in subjects with exudates or BHs or more than two M/DHs within one disc diameter. Having worse visual acuity was associated with about a fivefold higher prevalence of MO. Current manual screening grading schemes that ignore visual acuity or the presence of M/DHs could be improved by taking these into account. Health service costs increase substantially with more sensitive/less specific strategies. A fully automated strategy, using the automated detection of patterns of photographic surrogate markers, is superior to all current manual grading schemes for detecting MO in people with diabetes. The addition of optical coherence tomography (OCT) to each strategy, prior to referral, results in a reduction in costs to the health service with no decrement in the number of MO cases detected. Conclusions: Compared with all current manual grading schemes, for the same sensitivity, a fully automated strategy, using the automated detection of patterns of photographic surrogate markers, achieves a higher specificity for detecting MO in people with diabetes, especially if visual acuity is included in the automated strategy. Overall, costs to the health service are likely to increase if more sensitive referral strategies are adopted over more specific screening strategies for MO, for only very small gains in QALYs. The addition of OCT to each screening strategy, prior to referral, results in a reduction in costs to the health service with no decrement in the number of MO cases detected. © Queen's Printer and Controller of HMSO 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of presbyopia has been the focus of much scientific and clinical research over recent years, not least due to an increasingly aging population but also the desire for spectacle independence. Many lens and nonlens-based approaches have been investigated, and with advances in biomaterials and improved surgical methods, removable corneal inlays have been developed. One such development is the KAMRA™ inlay where a small entrance pupil is exploited to create a pinhole-type effect that increases the depth of focus and enables improvement in near visual acuity. Short- and long-term clinical studies have all reported significant improvement in near and intermediate vision compared to preoperative measures following monocular implantation (nondominant eye), with a large proportion of patients achieving Jaeger (J) 2 to J1 (~0.00 logMAR to ~0.10 logMAR) at the final follow-up. Although distance acuity is reduced slightly in the treated eye, binocular visual acuity and function remain very good (mean 0.10 logMAR or better). The safety of the inlay is well established and easily removable, and although some patients have developed corneal changes, these are clinically insignificant and the incidence appears to reduce markedly with advancements in KAMRA design, implantation technique, and femtosecond laser technology. This review aims to summarize the currently published peer-reviewed studies on the safety and efficacy of the KAMRA inlay and discusses the surgical and clinical outcomes with respect to the patient’s visual function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interaction of the wound dressing as a biomaterial with the wound bed is the central issue of this chapter. The interfacial phenomenon that encompasses the biological and biochemical consequences that arise when a biomaterial is introduced to a host biological environment is discussed. A great deal can be learned from observations arising from the behaviour of biomaterials at other body sites; one particularly relevant body site in the context of wound healing is the anterior eye. The cornea, tear film and posterior surface of the contact lens provide an informative model of the parallel interface that exists between the chronic wound bed, wound fluid and the dressing biomaterial. © 2011 Woodhead Publishing Limited All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the correlation between changes in corneal aberrations and the 2-year change in axial length in children fitted with orthokeratology (OK) contact lenses. METHODS: Thirty-one subjects 6 to 12 years of age and with myopia −0.75 to −4.00DS and astigmatism ≤1.00DC were fitted with OK. Measurements of axial length and corneal topography were taken at regular intervals over a 2-year period. Corneal topography at baseline and after 3 and 24 months of OK lens wear was used to derive higher-order corneal aberrations (HOA) that were correlated with OK-induced axial length changes at 2 years. RESULTS: Significant changes in C3, C4, C4, root mean square (RMS) secondary astigmatism and fourth and total HOA were found with both 3 and 24 months of OK lens wear in comparison with baseline (all P0.05). Coma angle of orientation changed significantly pre-OK in comparison with 3 and 24 months post-OK as well as secondary astigmatism angle of orientation pre-OK in comparison with 24 months post-OK (all P0.05). DISCUSSION: Short-term and long-term OK lens wear induces significant changes in corneal aberrations that are not significantly correlated with changes in axial elongation after 2-years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is estimated that 69-75 million people worldwide will suffer a traumatic brain injury (TBI) or stroke each year. Brain oedema caused by TBI or following a stroke, together with other disorders of the brain cost Europe €770 billion in 2014. Aquaporins (AQP) are transmembrane water channels involved in many physiologies and are responsible for the maintenance of water homeostasis. They react rapidly to changes in osmolarity by transporting water through their highly selective central pore to maintain tonicity and aid in cell volume regulation. We have previously shown that recombinant AQP1-GFP trafficking occurs in a proteinkinase C-microtubule dependant manner in HEK-293 cells in response to hypotonicity. This trafficking mechanism is also reliant on the presence of calcium and its messenger-binding protein calmodulin and results in increased cell surface expression of AQP1 in a time-scale of ~30 seconds. There is currently very little research into the trafficking mechanisms of endogenous AQPs in primary cells. AQP4 is the most abundantly expressed AQP within the brain, it is localised to the astrocytic end-feet, in contact with the blood vessels at the blood-brain-barrier. In situations where the exquisitely-tuned osmotic balance is disturbed, high water permeability can become detrimental. AQP4-mediated water influx causes rapid brain swelling, resulting in death or long term brain damage. Previous research has shown that AQP4 knock-out mice were protected from the formation of cytotoxic brain oedema in a stroke model, highlighting AQP4 as a key drug target for this pathology. As there are currently no treatments available to restrict the flow of water through AQP4 as all known inhibitors are either cytotoxic or non-specific, controlling the mechanisms involved in the regulation of AQP4 in the brain could provide a therapeutic solution to such diseases. Using cell surface biontinylation of endogenous AQP4 in primary rat astrocytes followed by neutraavidin based ELISA we have shown that AQP4 cell surface localisation increases by 2.7 fold after 5 minutes hypotonic treatment at around 85 mOsm/kg H2O. We have also shown that this rapid relocalisation of AQP4 is regulated by PKA, calmodulin, extra-cellular calcium and actin. In summary we have shown that rapid translocation of endogenous AQP4 occurs in primary rat astrocytes in response to hypotonic stimuli; this mechanism is PKA, calcium, actin and calmodulin dependant. AQP4 has the potential to provide a treatment for the development of brain oedema.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El Ap4A es una molécula con un amplio papel biológico en el ojo. Se ha descrito su implicación en procesos de secreción lagrimal, cicatrización epitelial, regulación de la presión intraocular, y presenta también un papel neuroprotector sobre los terminales simpáticos que inervan el cuerpo ciliar. El objetivo de este trabajo ha sido analizar la participación del Ap4A en otras posibles funciones a nivel ocular. En concreto se ha estudiado la capacidad de este dinucléotido para estimular la liberación de proteínas lagrimales de acción antibacteriana tales como la lisozima y la lactoferrina. Por otra parte se ha investigado su efecto como modulador de la función de barrera de la córnea a través de la regulación de los niveles de expresión de proteínas constituyentes de las tight junctions (TJ). Dicho efecto sobre la barrera puede tener una importante repercusión en la entrada de fármacos y en la consiguiente eficacia terapéutica de los mismos. Por último, se ha estudiado la posible implicación del dinucleótido en el proceso de edematización descrito en modelos animales glaucomatosos tales como el ratón DBA/2J. Con el objetivo de averiguar si la activación de Ap4A inducía un efecto sobre la producción de dos proteínas antimicrobianas relevantes de la lágrima (lisozima y lactoferrina) se realizaron ensayos en la lágrima de conejos albinos de Nueva Zelanda, mediante las técnicas de agar-agar y ELISA. Los resultados obtenidos demostraron que Ap4A produce un aumento en la concentración de lisozima y de lactoferrina del 93% y 24%, respectivamente, frente a valores basales, y este efecto está mediado por receptores de tipo P2...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La citología de impresión corneal es una técnica atraumática, simple, rápida y carente de efectos secundarios que permite estudiar las capas celulares más externas de la superficie ocular, posibilitando el diagnóstico de enfermedades de la misma y su monitorización durante y después del tratamiento. Los objetivos de la presente Tesis Doctoral han sido normalizar la técnica de obtención y procesamiento de muestras obtenidas por citología de impresión corneal en la especie canina, determinar los parámetros morfológicos y morfométricos fisiológicos de las células epiteliales corneales en perros sanos y establecer las alteraciones celulares corneales en el transcurso de la QCS canina. Además, se ha estudiado la existencia de una correlación entre las alteraciones del epitelio corneal y la producción lagrimal valorada mediante la prueba lagrimal de Schirmer I (PLS I). En este estudio se han incluido 60 perros de diferentes razas que han sido divididos en dos poblaciones: el grupo I, formado por pacientes sanos, con unos valores en la prueba lagrimal de Schirmer I (PLS I) iguales o superiores a 15 mm/min y el grupo II, formado por pacientes diagnosticados de QCS con unos valores en la PLS I comprendidos entre 0 y 14 mm/min. Los ojos de los animales del grupo II han sido categorizados a su vez en 3 subgrupos, estableciendo la gravedad de la enfermedad en función de los resultados obtenidos en la PLS I como grave, moderada o leve. Para facilitar la recogida y el manejo de las muestras, adecuar la técnica para su empleo en animales y disminuir al mínimo cualquier tipo de lesión iatrogénica sobre la superficie ocular se ha utilizado un dispositivo simple y eficaz, diferente a los que se han venido empleando tradicionalmente en oftalmología humana y veterinaria. La valoración morfométrica de las células se ha realizado atendiendo a los criterios de celularidad de la muestra, separación intercelular, morfología de las células, tinción citoplasmática, área celular, área nuclear, ratio núcleo/citoplasma (ratio N:C) y alteraciones nucleares...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We thank Darrin Sheppard and other staff at the University of Aberdeen Medical Research Facility for specialist technical assistance. We thank Patsy D. Goast for overnight microscope monitoring. This work was performed under the Biotechnology and Bioscience Research Council Grant number BB/E015840/1 to JMC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To better understand knowledge and attitudes concerning corneal donation among Chinese adults.
METHODS: Randomly selected residents in predetermined age strata 20 to 60+ years completed home-based questionnaires in each of 12 randomly chosen communities in Guangzhou, southern China.
RESULTS: Among 1217 selected persons, 430 (35.3%) completed the questionnaires (mean age 40.4 yrs, 57.9% female). Refusers were older (44.8 yrs, P < 0.001), but sex did not differ (52.2% female, P = 0.07). Among participants, 175 (40.7%) were willing to donate their corneas (WTD). Differences between WTD and not WTD included donation knowledge score (range, 1-12) [WTD (SD) 6.91 ± 2.21, not WTD 5.62 ± 2.43, P < 0.001]; having discussed donation (WTD 26.3%, not WTD 8.63%, P < 0.001); viewing donation as unpopular (WTD 88.0%, not WTD 96.5%, P = 0.001); and feeling donation "damages the body" (WTD 15.4%, not WTD 25.7%, P = 0.013). Associated significantly with WTD in multiple regression models were higher knowledge score [odds ratio (OR) = 1.18, 95% confidence interval (CI), 1.04-1.32, P = 0.008]; not feeling donation "damages the body" (OR = 1.91, 95% CI, 1.07-3.43, P = 0.030); and willingness to discuss donation (OR = 10.6, 95% CI, 3.35-33.9, P < 0.001). WTD did not differ by age (>60 yrs: 22/51, 43.1%; ≤60 yrs: 153/379, 40.4%, P = 0.706). Assuming all those refusing the survey would not donate, 14.4% (175/1217) were WTD for themselves, though only 7.1% (86/1217) would do so on behalf of a family member if they did not know the deceased's preference.
CONCLUSIONS: Interventions to increase knowledge and promote discussions about donation, and policies allowing widespread expression of donation preference, are needed in this setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Procedimiento de reconstrucción de la topografía corneal a partir de datos altimétricos o de curvatura. La invención consiste en un método de reconstrucción de la superficie de la cara anterior de la córnea, a partir de los datos medidos en un conjunto discreto de puntos por medio de un topógrafo corneal o equipo equivalente. Se trata de un procedimiento que obtiene una expresión analítica de la superficie, combinando un ajuste por polinomios de Zernike o con esfera de mejor ajuste, con una reconstrucción por funciones de base radial gaussianas. Se logra obtener una descripción detallada de la superficie corneal, permitiendo un diagnóstico más fiable de patologías, o la implementación de tratamientos customizados. Este procedimiento es fácilmente implementable en cualquier topógrafo corneal, tomógrafo de coherencia óptica, equipos de lámpara de hendidura y equivalentes, de los existentes en el mercado, como sustituto del método estándar basado en polinomios de Zernike.