Purpose: Polyvinyl alcohol (PVA) is a successful tear film stabiliser and is widely used in comfort drops and some soft contact lens materials. A PVA-containing lens, nelfilcon A has been modified to include additional (non-functional) PVA in order to provide improved comfort. This study aims to examine the clinical performance of this nelfilcon A lens with AquaRelease™ (AquaRelease). Methods: Two contralateral, investigator masked, open label, subjective and objective evaluations were conducted. The first examined the effect of adding increased molecular weight PVA to nelfilcon A (n = 5), and the second compared this AquaRelease lens to ocufilcon B (n = 34). The principal measures were non-invasive break-up time (NIBUT) and subjective comfort, which were assessed at the beginning and end of a week of daily wear, and three times throughout 1 day at 8, 12 and 16 h. Results: All subjects successfully completed the daily wearing schedule of 16 h. On initial insertion, subjective comfort and NIBUT improved for AquaRelease than original nelfilcon A lenses (p < 0.05). Initial comfort was better for AquaRelease compared to ocufilcon B lenses (p = 0.01); however, NIBUT was not statistically different (11.7 ± 15.6 s versus 8.4 ± 6.8 s; p = 0.26). Subjective comfort decreased with time (p < 0.001), but there was no significant difference between AquaRelease and ocufilcon B lenses (p = 0.16). NIBUT was not significantly affected by time (p = 0.56) or between lenses (p = 0.33). At the end of a weeks' wear, subjective initial, end-of-day, overall comfort and vision were rated significantly better with AquaRelease than ocufilcon B (p < 0.01). Conclusions: Release of additional non-functionalised PVA from the nelfilcon A lenses appears to enhance comfortable contact lens wear. © 2006 British Contact Lens Association.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The American Academy of Optometry (AAO) had their annual meeting in San Diego in December 2005 and the BCLA and CLAE were well represented there. The BCLA does have a reasonable number of non-UK based members and hopefully in the future will attract more. This will certainly be beneficial to the society as a whole and may draw more delegates to the BCLA annual conference. To increase awareness of the BCLA at the AAO a special evening seminar was arranged where BCLA president Dr. James Wolffsohn gave his presidential address. Dr. Wolffsohn has given the presidential address in the UK, Ireland, Hong Kong and Japan – making it the most travelled presidential address for the BCLA to date. Aside from the BCLA activity at the AAO there were numerous lectures of interest to all, truly a “something for everyone” meeting. All the sessions were multi-track (often up to 10 things occurring at the same time) and the biggest dilemma was often deciding what to attend and more importantly what you will miss! Nearly 200 new AAO Fellows were inducted at the Gala Dinner from many countries including 3 new fellows from the UK (this year they all just happened to be from Aston University!). It is certainly one of the highlights of the AAO to see fellows from different schools of training from around the world fulfilling the same criteria and being duly rewarded for their commitment to the profession. BCLA members will be aware that 2006 sees the introduction of the new fellowship scheme of the BCLA and by the time you read this the first set of fellowship examinations will have taken place. For more details of the FBCLA scheme see the BCLA web site http://www.bcla.org.uk. Since many of CLAE's editorial panel were at the AAO an informal meeting and dinner was arranged for them where ideas were exchanged about the future of the journal. It is envisaged that the panel will meet twice a year – the next meeting will be at the BCLA conference. The biggest excitement by far was the fact that CLAE is now Medline/PubMed indexed. You may ask why is this significant to CLAE? PubMed is the free web-based service from the US National Library of Medicine. It holds over 15 million biomedical citations and abstracts from the Medline database. Medline is the largest component of PubMed and covers over 4800 journals published in more than 70 countries. The impact of this is that CLAE is starting to attract more submissions as researchers and authors are not worried that their work will not be hidden from other colleagues in the field but rather the work is available to view on the World Wide Web. CLAE is one of a very small number of contact lens journals that is indexed this way. Amongst the other CL journals listed you will note that the International Contact Lens Clinic has now merged with CLAE and the journal CLAO has been renamed Eye and Contact Lenses – making the list of indexed CL journals even smaller than it appears. The on-line submission and reviewing system introduced in 2005 has also made it easier for authors to submit their work and easier for reviewers to check the content. This ease of use has lead to quicker times from submission to publication. Looking back at the articles published in CLAE in 2005 reveals some interesting facts. The majority of the material still tends to be from UK groups related to the field of Optometry, although we hope that in the future we will attract more work from non-UK groups and also from non-Optometric areas such as refractive surgery or anterior eye pathology. Interestingly in 2005 the most downloaded article from CLAE was “Wavefront technology: Past, present and future” by Professor W. Neil Charman, who was also the recipient of the Charles F. Prentice award at the AAO – one of the highest awards honours that the AAO can bestow. Professor Charman was also the keynote speaker at the BCLA's first Pioneer's Day meeting in 2004. In 2006, readers of CLAE will notice more changes, firstly we are moving to 5 issues per year. It is hoped that in the future, depending on increased submissions, a move to 6 issues may be feasible. Secondly, CLAE will aim to have one article per issue that carries CL CET points. You will see in this issue there is an article from Professor Mark Wilcox (who was a keynote speaker at the BCLA conference in 2005). In future articles that carry CET points will be either reviews from BCLA conference keynote speakers, members of the editorial panel or material from other invited persons that will be of interest to the readership of CLAE. Finally, in 2006, you will notice a change to the Editorial Panel, some of the distinguished panel felt that it was good time to step down and new members have been invited to join the remaining panel. The panel represent some of the most eminent names in the fields of contact lenses and/or anterior eye and have varying backgrounds and interests from many of the prominent institutions around the world. One of the tasks that the Editorial Panel undertake is to seek out possible submissions to the journal, either from conferences they attend (posters and papers that they will see and hear) and from their own research teams. However, on behalf of CLAE I would like to extend that invitation to seek original articles to all readers – if you hear a talk and think it could make a suitable publication to CLAE please ask the presenters to submit the work via the on-line submission system. If you found the work interesting then the chances are so will others. CLAE invites submissions that are original research, full length articles, short case reports, full review articles, technical reports and letters to the editor. The on-line submission web page is http://www.ees.elsevier.com/clae/.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: Theoretically myopes are required to exert more accommodation and vergence when wearing single vision contact lenses compared to glasses and hypermetropes less. This study aims to quantify the effects clinically. Method: Thirty subjects (21 female, nine male, average age 21.0 ± 2.2 years) with a range of refractive errors (-7.87 D to +3.50 D) viewed in a random order, static targets at 0.1, 0.5, 1.0, 2.0, 3.0, 4.0 and 5.0 D accommodative demand that were matched for angular subtense. The subjects were fully corrected with spectacles and daily disposable contact lenses to their full prescription. Accommodation was monitored objectively with the PowerRefractor and Shin-Nippon SRW5000 and vergence and pupil size with the PowerRefractor. Results: Myopes exerted greater accommodative effort for viewing near targets with contact lenses than glasses and hypermetropes less (r2 = 0.35, p = 0.001 PowerRefractor). Myopes also exerted greater vergence effort for viewing near targets with contact lenses than glasses and hypermetropes less (r2 = 0.22, p < 0.01). Conclusion: Theoretical calculation of the accommodative and vergence requirements with glasses compared to contact lenses reflect clinical findings, although there is reasonable variability between individuals. © 2006 British Contact Lens Association.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. This study reports data from an 18-month longitudinal study of neophyte contact lens wearers and compares changes in ocular refraction and biometry induced by daily wear and continuous wear of two different silicone hydrogel (SiH) materials. Methods. Forty-five subjects were enrolled in the study and randomly assigned to wear one of the two silicone hydrogel materials: Lotrafilcon A or Balafilcon A lenses on either a daily or continuous wear basis. Measurements of objective refraction, axial length, anterior chamber depth, corneal curvature, and the rate of peripheral corneal flattening were performed before and 1, 3, 6, 12, and 18 months after initial fitting. Results. Mean spherical equivalent refractive error increased in the myopic direction in all contact lens groups across time (p < 0.001). Axial length was the main biometric contributor to the development of myopia. After 18 months of lens wear, subjects in the Lotrafilcon A group showed the greater mean increase in myopia (i.e., -0.50 D). Conclusions. The results of this study show that increases in myopia, similar if not higher than those found to occur normally in young adult noncontact lens wearers, still occur with silicone hydrogel contact lens wear. The main biometric contributor to the progression of myopia was an increase in axial length. Differences between our results and those of previous studies with silicone hydrogel contact lenses could be attributed to the differing populations used in which both age and occupation may have played a role. Copyright © 2005 American Academy of Optometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Autofluorescence of ultraviolet (UV) light has been shown to occur in localised areas of the bulbar conjunctiva, which map to active cellular changes due to UV and environmental exposure. This study examined the presence of conjunctival UV autofluorescence in eye care practitioners (ECPs) across Europe and the Middle East and its associated risk factors. Method: Images were captured of 307 ECPs right eyes in the Czech Republic, Germany, Greece, Kuwait, Netherlands, Sweden, Switzerland, United Arab Emirates and the United Kingdom using a Nikon D100 camera and dual flash units through UV filters. UV autofluorescence was outlined using ImageJ software and the nasal and temporal area quantified. Subjects were required to complete a questionnaire on their demographics and lifestyle including general exposure to UV and refractive correction. Results: Average age of the subjects was 38.5±12.2 years (range 19-68) and 39.7% were male. Sixty-two percent of eyes had some conjunctival damage as indicated by UV autofluorescence. The average area of damage was higher (p=0.005) nasally (2.95±4.52mm2) than temporally (2.19±4.17mm2). The area of UV damage was not related to age (r=0.03, p=0.674), gender (p=0.194), self-reported sun exposure lifestyle (p>0.05), geographical location (p=0174), sunglasses use (p>0.05) or UV-blocking contact lens use (p>0.05), although it was higher in those wearing contact lenses with minimal UV-blocking and no spectacles (p=0.015). The area of UV damage was also less nasally in those who wore contact lenses and spectacles compared to those with no refractive correction use (p=0.011 nasal; p=0.958 temporal). Conclusion: UV conjunctival damage is common even in Europe, Kuwait and UAE, and among ECPs. The area of damage appears to be linked with the use of refractive correction, with greater damage nasally than temporally which may be explained by the peripheral light focusing effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper focuses on the effects of wear regime on the deposition pattern of important immunoregulatory proteins on FDA Group IV etafilcon-A lenses. Specifically, the aim was to assess the extent to which the daily disposable wear modality produces a different deposition of proteins from the conventional daily wear regime which is coupled with cleaning and disinfection. Counter immunoelectrophoresis (CIE) was employed to detect individual proteins in lens extracts from individual patients and focused on the analysis of five proteins, IgA, IgG, lactoferrin, albumin and kininogen. Deposition was monitored as a function of time; significantly lower deposition was detected on the daily disposable lenses. cr 2002 British Contact Lens Association. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The kinin family are a group of bioactive peptides that are closely involved in the modulation of vascular inflammation and local injury. We have demonstrated here, for the first time, a link between kinin activity and contact lens wear. Protein extracts from daily and extended wear etafilcon A, Group IV, Acuvue lenses (Vistakon), were analysed by counter immunoelectrophoresis. In this way, kinin activity associated with contact lens wear was detected. High molecular weight kininogen was used as the marker protein. In contrast, no kinin activity was detected in the non-lens wearing normal eye. © 2002 British Contact Lens Association. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Refraction simulators used for undergraduate training at Aston University did not realistically reflect variations in the relationship between vision and ametropia. This was because they used an algorithm, taken from the research literature, that strictly only applied to myopes or older hyperopes and did not factor in age and pupil diameter. The aim of this study was to generate new algorithms that overcame these limitations. Clinical data were collected from the healthy right eyes of 873 white subjects aged between 20 and 70 years. Vision and refractive error were recorded along with age and pupil diameter. Re-examination of 34 subjects enabled the calculation of coefficients of repeatability. The study population was slightly biased towards females and included many contact lens wearers. Sex and contact lens wear were, therefore, recorded in order to determine whether these might influence the findings. In addition, iris colour and cylinder axis orientation were recorded as these might also be influential. A novel Blur Sensitivity Ratio (BSR) was derived by dividing vision (expressed as minimum angle of resolution) by refractive error (expressed as a scalar vector, U). Alteration of the scalar vector, to account for additional vision reduction due to oblique cylinder axes, was not found to be useful. Decision tree analysis showed that sex, contact lens wear, iris colour and cylinder axis orientation did not influence the BSR. The following algorithms arose from two stepwise multiple linear regressions: BSR (myopes) = 1.13 + (0.24 x pupil diameter) + (0.14 x U) BSR (hyperopes) = (0.11 x pupil diameter) + (0.03 x age) - 0.22 These algorithms together accounted for 84% of the observed variance. They showed that pupil diameter influenced vision in both forms of ametropia. They also showed the age-related decline in the ability to accommodate in order to overcome reduced vision in hyperopia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study investigated how aberration-controlling, customised soft contact lenses corrected higher-order ocular aberrations and visual performance in keratoconic patients compared to other forms of refractive correction (spectacles and rigid gas-permeable lenses). Methods: Twenty-two patients (16 rigid gas-permeable contact lens wearers and six spectacle wearers) were fitted with standard toric soft lenses and customised lenses (designed to correct 3rd-order coma aberrations). In the rigid gas-permeable lens-wearing patients, ocular aberrations were measured without lenses, with the patient's habitual lenses and with the study lenses (Hartmann-Shack aberrometry). In the spectacle-wearing patients, ocular aberrations were measured both with and without the study lenses. LogMAR visual acuity (high-contrast and low-contrast) was evaluated with the patient wearing their habitual correction (of either spectacles or rigid gas-permeable contact lenses) and with the study lenses. Results: In the contact lens wearers, the habitual rigid gas-permeable lenses and customised lenses provided significant reductions in 3rd-order coma root-mean-square (RMS) error, 3rd-order RMS and higher-order RMS error (p ≤ 0.004). In the spectacle wearers, the standard toric lenses and customised lenses significantly reduced 3rd-order RMS and higher-order RMS errors (p ≤ 0.005). The spectacle wearers showed no significant differences in visual performance measured between their habitual spectacles and the study lenses. However, in the contact lens wearers, the habitual rigid gas-permeable lenses and standard toric lenses provided significantly better high-contrast acuities compared to the customised lenses (p ≤ 0.006). Conclusions: The customised lenses provided substantial reductions in ocular aberrations in these keratoconic patients; however, the poor visual performances achieved with these lenses are most likely to be due to small, on-eye lens decentrations. © 2014 The College of Optometrists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background - The aim was to derive equations for the relationship between unaided vision and age, pupil diameter, iris colour and sphero-cylindrical refractive error. Methods - Data were collected from 663 healthy right eyes of white subjects aged 20 to 70 years. Subjective sphero-cylindrical refractive errors ranged from -6.8 to +9.4 D (mean spherical equivalent), -1.5 to +1.9 D (orthogonal component, J0) and -0.8 to 1.0 D (oblique component, J45). Cylinder axis orientation was orthogonal in 46 per cent of the eyes and oblique in 18 per cent. Unaided vision (-0.3 to +1.3 logMAR), pupil diameter (2.3 to 7.5 mm) and iris colour (67 per cent light/blue irides) was recorded. The sample included mostly females (60 per cent) and many contact lens wearers (42 per cent) and so the influences of these parameters were also investigated. Results - Decision tree analysis showed that sex, iris colour, contact lens wear and cylinder axis orientation did not influence the relationship between unaided vision and refractive error. New equations for the dependence of the minimum angle of resolution on age and pupil diameter arose from step backwards multiple linear regressions carried out separately on the myopes (2.91.scalar vector +0.51.pupil diameter -3.14 ) and hyperopes (1.55.scalar vector + 0.06.age – 3.45 ). Conclusion - The new equations may be useful in simulators designed for teaching purposes as they accounted for 81 per cent (for myopes) and 53 per cent (for hyperopes) of the variance in measured data. In comparison, previously published equations accounted for not more than 76 per cent (for myopes) and 24 per cent (for hyperopes) of the variance depending on whether they included pupil size. The new equations are, as far as is known to the authors, the first to include age. The age-related decline in accommodation is reflected in the equation for hyperopes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Editorial: The 2015 BCLA annual conference was another fantastic affair. It was the first time the conference was held in the beautiful city of Liverpool. The venue was great and the programme was excellent. The venue overlooked the River Mersey and many of the hotels were local boutique hotels. I stayed in one which was formerly the offices of White Star Liners—where the RMS Titanic was originally registered. The hotel decor was consistent with its historic significance. The BCLA gala dinner was held in the hugely impressive Anglican Cathedral with entertainment from a Beatles tribute band. That will certainly be a hard act to follow at the next conference in 2017. Brian Tompkins took the reigns as the new BCLA president. Professor Fiona Stapleton was the recipient of the BCLA Gold Medal Award. The winner of the poster competition was Dorota Szczesna-Iskander with a poster entitled ‘Dry Contact lens poor wettability and visual performance’. Second place was Renee Reeder with her poster entitled ‘Abnormal Rosacea as a differential diagnosis in corneal scarring’. And third place was Maria Jesus Gonzalez-Garcia with her poster entitled ‘Dry Effect of the Environmental Conditions on Tear Inflammatory Mediators Concentration in Contact Lens Wearers’. The photographic competition winner was Professor Wolfgang Sickenberger from Jena in Germany. The Editorial Panel of CLAE met at the BCLA conference for their first biannual meeting. The journal metrics were discussed. In terms of number of submissions of new papers CLAE seems to have plateaued after seeing a rapid growth in the number of submissions over the last few years. The increase over the last few years could be attributed to the fact that CLAE was awarded an impact factor for the first time in 2012. This year it seems that impact factors across nearly all ophthalmic related journals has dropped. This could in part be due to the fact that last year was a ‘Research Exercise Framework (REF) year for UK universities, where they are judged on quality of their research output. The next REF is in 2020 so we may see changes nearing that time. Looking at article downloads, there seems to be a continued rise in figures. Currently CLAE attracts around 85,000 downloads per year (this is an increase of around 10,000 per year for the last few years) and the 2015 prediction is 120,000! With this in mind and with other contributing factors too, the BCLA has decided to move to online delivery of CLAE to its members starting from issue 5 of 2015. Some members do like to flick through the pages of a hard copy of the journal so members will still have the option of receiving a hard copy through the post but the default journal delivery method will now be online. The BCLA office will send various alerts and content details to members email addresses. To access CLAE online you will need to log in via the BCLA web page, currently you then click on ‘Resources’ and then under ‘Free and Discounted Publications’ you will see CLAE. This actually takes you to CLAE’s own webpage (www.contactlensjournal.com) but you need to log in via the BCLA web page. The BCLA plans to change these weblinks so that from the BCLA web page you can link to the journal website much more easily and you have the choice of going directly into the general website for CLAE or straight to the current issue. In 2016 you will see an even easier way of accessing CLAE online as the BCLA will launch a CLAE application for mobile devices where the journal can be downloaded as a ‘flick-book’. This is a great way of bringing CLAE into the modern era where people access their information in newer ways. For many the BCLA conference was part of a very busy conference week as it was preceded by the International Association of Contact Lens Educators’ (IACLE) Third World Congress, held in Manchester on the 4 days before the BCLA conference. The first and second IACE World Congresses were held in Waterloo, Canada in 1994 and 2000 respectively and hosted by Professor Des Fonn. Professor Fonn was the recipient of the first ever IACLE lifetime achievement award. The Third IACLE World Congress saw more than 100 contact lens educators and industry representatives from around 30 countries gather in the UK for the four-day event, hosted by The University of Manchester. Delegates gained hands-on experience of innovations in teaching, such as learning delivery systems, the use of iPads in the classroom and for creating ePub content, and augmented and virtual reality technologies. IACLE members around the world also took part via a live online broadcast. The Third IACLE World Congress was made possible by the generous support of Sponsors Alcon, CooperVision and Johnson & Johnson Vision Care., for more information look at the IACLE web page (www.iacle.org).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To assess the performance of four commercially available silicone hydrogel multifocal monthly contact lens designs against monovision. METHODS: A double-masked randomized crossover trial of Air Optix Aqua multifocal, PureVision 2 for Presbyopia, Acuvue OASYS for Presbyopia, Biofinity multifocal, and monovision with Biofinity contact lenses was conducted on 35 presbyopes (54.3 ± 6.2 years). After 4 weeks of wear, visual performance was quantified by high- and low-contrast visual acuity under photopic and mesopic conditions, reading speed, defocus curves, stereopsis, halometry, aberrometry, Near Activity Visual Questionnaire rating, and subjective quality of vision scoring. Bulbar, limbal, and palpebral hyperemia and corneal staining were graded to monitor the impact of each contact lens on ocular physiology. RESULTS: High-contrast photopic visual acuity (p = 0.102), reading speed (F = 1.082, p = 0.368), and aberrometry (F = 0.855, p = 0.493) were not significantly different between presbyopic lens options. Defocus curve profiles (p <0.001), stereopsis (p <0.001), halometry (F = 4.101, p = 0.004), Near Activity Visual Questionnaire (F = 3.730, p = 0.007), quality of vision (p = 0.002), bulbar hyperemia (p = 0.020), and palpebral hyperemia (p = 0.012) differed significantly between lens types, with the Biofinity multifocal lens design principal (center-distance lens was fitted to the dominant eye and a center-near lens to the nondominant eye) typically outperforming the other lenses. CONCLUSIONS: Although ocular aberration variation between individuals largely masks the differences in optics between current multifocal contact lens designs, certain design strategies can outperform monovision, even in early presbyopes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To assess the surface tear breakup time and clinical performance of three daily disposable silicone hydrogel contact lenses over 16 hours of wear. METHODS: Thirty-nine patients (mean [±SD] age, 22.1 [±3.5] years) bilaterally wore (narafilcon A, filcon II-3, and delefilcon A) contact lenses in a prospective, randomized, masked, 1-week crossover clinical trial. Tear film was assessed by the tear meniscus height (TMH), ocular/contact lens surface temperature dynamics, and lens surface noninvasive breakup time at 8, 12, and 16 hours of wear. Clinical performance and ocular physiology were assessed by subjective questionnaire, by high-/low-contrast logMAR (logarithm of the minimum angle of resolution) acuity, and through bulbar and limbal hyperemia grading. Corneal and conjunctival staining were assessed after lens removal. RESULTS: Delefilcon A demonstrated a longer noninvasive breakup time (13.4 [±4.4] seconds) than filcon II-3 (11.6 [±3.7] seconds; p < 0.001) and narafilcon A (12.3 [±3.7] seconds; p < 0.001). A greater TMH (0.35 [±0.11] mm) was shown by delefilcon A than filcon II-3 (0.32 [±0.10] seconds; p = 0.016). Delefilcon A showed less corneal staining after 16 hours of lens wear (0.7 [±0.6] Efron grade) than filcon II-3 (1.1 [±0.7]; p < 0.001) and narafilcon A (0.9 [±0.7]; p = 0.031). Time was not a significant factor for prelens tear film stability (F = 0.594, p = 0.555) or TMH (F = 0.632, p = 0.534). Lens brand did not affect temperature (F = 1.220, p = 0.308), but it decreased toward the end of the day (F = 19.497, p < 0.001). Comfort, quality of vision, visual acuity and contrast acuity, and limbal grading were similar between the lens brands but decreased with time during the day (p < 0.05). CONCLUSIONS: The tear breakup time over the contact lens surface differed between lens types and may have a role in protecting the ocular surface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Full text: Welcome to issue 1 of 2012 and a belated Happy New Year to all CLAE readers and BCLA members. The hardest job I had for this issue was to decide which papers to include and which papers to hang on to and save for issue 2 of 2012. At the end of December when I was choosing the content for this issue there were additional 5 papers that could have been included. The final choice came down to various factors; such as first come first served – i.e. which papers had been ready and waiting the longest; secondly which papers had been submitted the earliest; are there similar papers so that it may be beneficial to publish them alongside this paper; and also was the content something which needed to be out there quicker than other papers as it was a current hot topic? But it should be noted that once papers are proofed and deemed ready by authors they are published in the epub version and put online for others to see in their final version. An epub version is given a DOI number (digital object identifier) so that it can be cited by other authors. Apart from being on line the only other difference is that an epub version is essentially waiting to be assigned to a particular issue. So those papers that are being held off for issue 2 of this year are actually already available for you to read (and cite) on line. In this issue there is a paper related to the cost of different contact lens replacement schedules – this may be a topic that is debated more in the future since as a society we are thinking more ‘green’ and all trying to help by reducing our carbon footprint, whether that be by recycling or using less in the first place. A timely review paper on the management of allergic eye disease may help us to better manage those patients we see in the spring with pollen allergies. We have two papers looking at different aspects in keratoconus patients, another looking at a modified fluoret strip and its application in measuring tear break up time and a review paper on corneal erosions. Another interesting paper comes from Professor Harminder Dua and his team. Professor Dua is the UK Royal College of Ophthalmologists’ president and has been interested in corneal anatomy and physiology for much of his research career. Finally, an unusual case of an ocular injury related to a snake bite. Overall I would say there is enough to sink your ‘fangs’ into! Finally, it gives me great pleasure in announcing the newest person to join our Editorial Board, Dr Florence Malet. Dr Malet is an Ophthalmologist and since September 2000 she has been at the Bordeaux Hospital in France developing the Contact Lens Unit of in the Ophthalmology University Department. She is ex-president of the French Contact Lens Society and president of the European Contact Lens Society of Ophthalmologists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose - To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods - The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00 D and +6.00 D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results - The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p < 0.001) but no significant difference was found between the two powers of CLs. Conclusions - Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.