945 resultados para constituintes do esgoto
Resumo:
The process of environmental impact assessment (EIA), in the extent of previous environmental studies, has as one of its functions to provide subsidies to the actions of environmental managment of enterprises. However, the proper estructuring of programs that allows to support this managment does not often occurs. This research sought as one of its objectives to evaluate in which extent the process of EIA can be a subsidie for the EMS, providing basic elements of this system. In addition, more specifically, the research had as one of its objetives the development of subsidies for the implantation of an Environmental Managment System (EMS), based on the model of ISO 14001 (2004), for a sewage treatment plant yet to be constructed in the city of President Venceslau / SP. In order to achieve theses objetives, a discussion was held based on the evaluation of environmental studies available in the library of Cetesb / SMA. Still, for the elaboration of subsidies for the EMS of the treatment plant, the research was focused on the structuring of environmental management program, based on the information contained in its Preliminary Environmental Report (PER). The research had as one of its products, the development of subsidies for the planning and control of the environmental aspects and impacts and for the environmental program of the enterprise, based on the use of environmental indicators. It was concluded, based on the results that, in general, the previous environmental studies analyzed showed little emphasis on the phase of development of structured environmental programs that offer guidelines to achieve the desired results for the environmental performance of the company.
Resumo:
The non existence of sewage services creates an unhealthy environmental, causing impact extremely prejudicial to the human health. In Brazil, this item represents the biggest deficit in the basic sanitation these days, and only about 50% of the population is attended. The sewage collection network is a needful system for the basic sanitation. Between the parameters of the project of a system of collection and sewage transportation, the definition of the population that will be attended is one of the most important variables, and that should be done based on criterion of population growth and in accordant to directrix presents in the comprehensive city plan. In this paper, were evaluated methods of growth based on the geometric growth rate, on the population density and on the number of residents per dwelling, and also mathematics models of growth prediction, emphasizing in the geometric growth and on the logistic curve method. That way, the goal of this paper were value the hydraulic performance in one of the watersheds delimited by the sewage network magnification work existent in the city of Cacoal–RO. Using simulation with different scenarios, the results pointed that the hydraulic performance of the system were strongly affected by the population determination method used. For the same drained area the diameters range from 150 to 250 mm as well as the trench’s deep, where some stretches exceeded the maximum values contained in the standard. Besides, the variation of the sewage contribution rate due the population variation estimated in different scenarios, led to alterations in others important project parameters, such as slope, shallow pool, tensile stress and spreading velocity
Resumo:
The use of rainwater for non-potable purposes generates a reduction in the consumption of treated water, however, this reduction is not observed in the generation of wastewater, as this is independent of the water source. In Brazil, the pricing on the services of collection and treatment of sewage, in general, is based on the coefficient of return of the sewage disposal system, which has a relation sewer / water proportional to the consumption of treated water measured at the consumer unit. The use of rainwater originating from utilization systems infer on the coefficient, underestimating the volume of wastewater generated. Therefore, this study presents a methodology for setting the coefficient of return. Different roof areas, reservoir volumes and rates of water consumption situations were simulated. The behavior of adjustment of the coefficient of return were also analyzed for the average area per capita roof (m² / inhabitant) of Rio Claro - SP. As a result, it can be seen that the adjustment of the coefficient of return is directly proportional to the increase of the roof areas and the volumes of reservoirs, and inversely proportional to the total water demand. The corrected coefficient of return showed the minimum value of 0.83 and a maximum value of 1.45, this variation corresponds to the maximum ratio between the demands of total water and rainwater, since the exploitation of rain water should be used only for non-potable uses, according to NBR 15527 / 07. To the municipality of Rio Claro - SP was noted an adjustment of the coefficient of return ranging from 0.99 to 6.61
Resumo:
The anaerobic treatment of sewage is widely employed in Brazil and it is an appreciated way for the treatment of effluents, helping to reduce the environmental impact in rivers. The methane gas obtained from the process can be applied to improve the energetic efficiency of the system, reducing the amount of waste and the cost of the treatment process. This work presents the net energy balance of anaerobic reactors applied to the treatment of sewage. The analysis was performed considering full-scale and laboratory-scale treatment systems. In laboratory scale, the results from three kinds of systems were compared regarding the biological treatment of greywater. Two of them (UASB7 and UASB12) were anaerobic and the other one was a combined anaerobic-aerobic system (UASB7/SBR6). Greywater methanization (compared to theoretical maximum) was calculated considering 100% removal (g BOD/day), the literature percentage removal and the anionic surfactant presence in the effluentt. For each of these three cases, the efficiencies were, respectively, 16.9%, 43.6% and 51.3% in UASB7 reactor, 25.6%, 50.3% and 59.2% in UASB12 reactor and 30.6%, 61.2% and 71.9% in UASB7/SBR6 reactor. The energetic potential was found to be 4.66x10-4, 7.77x10-4 and 5.12x10-4 kWh/L for the UASB7, UASB12 and UASB7/SBR6 reactors, respectively. The pumping system, the aeration (in the anaerobic-aerobic system) and the temperature controlled heating system were considered to calculate the energetic consumption. However, the third one was not employed since tropical regions like Brazil do not need heating systems and also because of its high energetic consumption. The calculated net energy balance in the reactors was negative in the case of greywater, respectively -0.16, -0.28 and -0.18 kWh/L for the reactors UASB7, UASB12 and UASB7/SRB6. In full scale (ETE Jardim das Flores - Rio Claro, SP), the average energy... (Complete abstract click electronic access below)
Resumo:
Não disponível
Resumo:
Não disponível
Resumo:
The actual work broaches a study about the collection and treatment of sanitary sewage from the municipality of Ubatuba in its operational aspects and the tariff policy from the service. Themes related to the subject like the history of collection and treatment of sewage, its development in Brazil and its importance for public health and environmental preservation, as well as historical and geographical aspects of Ubatuba/SP, are present in the literature review. The methodology consists in guided visit in the colletion and treatment of sewage facilities and interview with technical managers. With the technical data obtained, it is made a discussion of the results and possible recommendations
Resumo:
The purpose of this project is to verify whether anaerobic reactors applied to sewage treatment are energetically self-sufficient. This evaluation can be made by balancing the methane produced through the anaerobic transformation stages (hydrolysis, acidogenesis, acetogenesis and methanogenesis) and the reactor energy consumption requirements. The original project included methanogenic activity tests, which could not be performed due to setbacks in the installation of an analytical instrument. Scientific articles about bench- and full-scale anaerobic reactors were investigated instead. An average substrate-to-methane conversion efficiency of 58,2±18,6% was found for the bench-scale reactors and higher efficiencies (89,2%) were found for the cases which had higher Organic Loading Rates (OLRs) values. The average energy output was 0,013 kWh/Lsewage, value unable to meet the energy needs for the reactor operation, considering equipments normally used such as temperature controller. This balance can become positive if few hypotheses are made, for example (i) to eliminate the use of temperature controller (ii) to alter the operation pattern from continuous to intermittent. Based on energy balance assessment of eight bench-scale reactors, it was observed that the implementation of a system for biogas utilization is not energetically feasible. However, interesting results were found for a full-scale sewage treatment plant, ETE Ouro Verde – Foz do Iguaçu, PR, Brazil. Even though its substrate-tomethane conversion efficiency was about 10% only, the energy balance was quite positive, with energy consumption of 68 kWh/month and energy production of 660 kWh/month. This analysis leads us to conclude that energy recovery from full-scale sewage treatment plants should be practiced by other plants
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Agronomia (Produção Vegetal) - FCAV
Resumo:
Pós-graduação em Agronomia (Ciência do Solo) - FCAV
Resumo:
Based on Hengeveld and Mackenzie (2008)’s Functional Discourse Grammar (FDG), this article aims to analyze the natural and marked orderings of argument constituents in declarative sentences of Brazilian Portuguese taken in IBORUNA corpora. In this way, we conclude that the two natural orderings, proposed by Pezatti (1992), are determined by semantic factor, especially by semantic functions, while the marked ordering ir determined by pragmatic factor, especially by the attribution of pragmatic functions.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
CHEMICAL CONSTITUENTS OF Hyptidendron canum (Pohl ex Benth.) R. Harley (LAMIACEAE). Chemical investigation of Hyptidendron canum stems resulted in the isolation of betulinic, ursolic and euscaphic acids. From the leaves were isolated 3β-O- β-galactopiranosilsitosterol, ursolic aldehyde, and mixtures of maslinic acid and 2α-hydroxyursolic acid, α and β-amyrin, uvaol and erythrodiol, sitosterol and stigmasterol, spathulenol and globulol. Hexane and chloroform leave fractions as well as ursolic and betulinic acids showed antifungal activities against the yeast form of Paracoccidioides brasiliensis.
Resumo:
Pós-graduação em Engenharia Civil - FEIS