974 resultados para congenital diaphragmatic bochdaleck hernia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate long-term outcome of initial aortic valve intervention in a paediatric population with congenital aortic stenosis, and to determine risk factors associated with reintervention. PATIENTS AND METHODS: From 1985 to 2009, 77 patients with congenital aortic stenosis and a mean age of 5.8±5.6 years at diagnosis were followed up in our institution for 14.8±9.1 years. RESULTS: First intervention was successful with 86% of patients having a residual peak aortic gradient 1 regurgitation increased by 7%. Long-term survival after the first procedure was excellent, with 91% survival at 25 years. At a mean interval of 7.6±5.3 years, 30 patients required a reintervention (39%), mainly because of a recurrent aortic stenosis. Freedom from reintervention was 97, 89, 75, 53, and 42% at 1, 10, 15, 20, and 25 years, respectively. Predictors of reintervention were residual peak aortic gradient (p=0.0001), aortic regurgitation post-intervention >1 (p=0.02), prior balloon aortic valvuloplasty (p=0.04), and increased left ventricular posterior wall thickness (p=0.1). CONCLUSIONS: Aortic valve intervention is a safe and effective procedure for congenital aortic stenosis with excellent survival results. However, rate of reintervention is high and influenced by increased left ventricular posterior wall thickness pre-intervention, prior balloon valvuloplasty, higher residual peak systolic valve gradient, and more than mild regurgitation post-intervention. The study highlights that long-term follow-up is recommended for these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: In 2005-2006, several studies noted an increased risk of cardiovascular birth defects associated with maternal use of paroxetine compared with other antidepressants in the same class. In this study, the authors sought to determine whether paroxetine was associated with an increased risk of cardiovascular defects in infants of women exposed to the drug during the first trimester of pregnancy. METHOD: From teratology information services around the world, the authors collected prospectively ascertained, unpublished cases of infants exposed to paroxetine early in the first trimester of pregnancy and compared them with an unexposed cohort. The authors also contacted the authors of published database studies on antidepressants as a class to determine how many of the women in those studies had been exposed to paroxetine and the rates of cardiovascular defects in their infants. RESULTS: The authors were able to ascertain the outcomes of 1,174 infants from eight services. The rates of cardiac defects in the paroxetine group and in the unexposed group were both 0.7%. The rate in the database studies (2,061 cases from four studies) was 1.5%. CONCLUSIONS: Paroxetine does not appear to be associated with an increased risk of cardiovascular defects following use in early pregnancy, as the incidence in more than 3,000 infants was well within the population incidence of approximately 1%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study determines the prevalence of Congenital Heart Defects (CHD), diagnosed prenatally or in infancy, and fetal and perinatal mortality associated with CHD in Europe. METHODS AND RESULTS: Data were extracted from the European Surveillance of Congenital Anomalies central database for 29 population-based congenital anomaly registries in 16 European countries covering 3.3 million births during the period 2000 to 2005. CHD cases (n=26 598) comprised live births, fetal deaths from 20 weeks gestation, and terminations of pregnancy for fetal anomaly (TOPFA). The average total prevalence of CHD was 8.0 per 1000 births, and live birth prevalence was 7.2 per 1000 births, varying between countries. The total prevalence of nonchromosomal CHD was 7.0 per 1000 births, of which 3.6% were perinatal deaths, 20% prenatally diagnosed, and 5.6% TOPFA. Severe nonchromosomal CHD (ie, excluding ventricular septal defects, atrial septal defects, and pulmonary valve stenosis) occurred in 2.0 per 1000 births, of which 8.1% were perinatal deaths, 40% were prenatally diagnosed, and 14% were TOPFA (TOPFA range between countries 0% to 32%). Live-born CHD associated with Down syndrome occurred in 0.5 per 1000 births, with > 4-fold variation between countries. CONCLUSION: Annually in the European Union, we estimate 36 000 children are live born with CHD and 3000 who are diagnosed with CHD die as a TOFPA, late fetal death, or early neonatal death. Investing in primary prevention and pathogenetic research is essential to reduce this burden, as well as continuing to improve cardiac services from in utero to adulthood.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To elucidate the aetiology of congenital Brown syndrome. METHODS: Four consecutive patients diagnosed with unilateral congenital Brown syndrome had a comprehensive standardized ocular motility examination. Any compensatory head posture was measured. Brain magnetic resonance imaging (MRI) with regard for the IV cranial nerve (CN) was performed in all patients. Orbital MRI was performed in 2/4 patients, with images acquired in eight directions of gaze and superior oblique (SO) muscle areas compared. RESULTS: CN IV could not be identified bilaterally in two patients, but was absent only on the side of the Brown syndrome in the two other patients. On the normal side, orbital MRI revealed a smaller SO muscle area in upgaze than in downgaze, demonstrating normal actions of this muscle. On the side of the Brown syndrome, the SO area remained the same in upgaze and in downgaze and approximately symmetric to the area of SO in downgaze on the normal side. CONCLUSIONS: These cases add further anatomical support to the theory of paradoxical innervation in congenital Brown syndrome. CN IV was absent in two patients on the side of the Brown syndrome, but without muscle hypoplasia. SO muscle size did not vary in up- and downgaze, which we interpreted as a sign of constant innervation through branches of CN III.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We evaluated the prenatal detection of gastrointestinal obstruction (GIO, including atresia, stenosis, absence or fistula) by routine ultrasonographic examination in an unselected population all over Europe. METHODS: Data from 18 congenital malformation registries in 11 European countries were analysed. These multisource registries used the same methodology. All fetuses/neonates with GIO confirmed within 1 week after birth who had prenatal sonography and were born during the study period (1 July 1996 to 31 December 1998) were included. RESULTS: There were 670 793 births in the area covered and 349 fetuses/neonates had GIO. The prenatal detection rate of GIO was 34%; of these 40% were detected < or = 24 weeks of gestation (WG). A total of 31% (60/192) of the isolated GIO were detected prenatally, as were 38% (59/157) of the associated GIO (p=0.26). The detection rate was 25% for esophageal obstruction (31/122), 52% for duodenal obstruction (33/64), 40% for small intestine obstruction (27/68) and 29% for large intestine obstruction (28/95) (p=0.002). The detection rate was higher in countries with a policy of routine obstetric ultrasound. Fifteen percent of pregnancies were terminated (51/349). Eleven of these had chromosomal anomalies, 31 multiple malformations, eight non-chromosomal recognized syndromes, and one isolated GIO. The participating registries reflect the various national policies for termination of pregnancy (TOP), but TOPs after 24 WG (11/51) do not appear to be performed more frequently in countries with a liberal TOP policy. CONCLUSION: This European study shows that the detection rate of GIO depends on the screening policy and on the sonographic detectability of GIO subgroups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The EUROCAT website www.eurocat-network.eu publishes prenatal detection rates for major congenital anomalies using data from European population-based congenital anomaly registers, covering 28% of the EU population as well as non-EU countries. Data are updated annually. This information can be useful for comparative purposes to clinicians and public health service managers involved in the antenatal care of pregnant women as well as those interested in perinatal epidemiology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION. Patient-ventilator asynchrony is a frequent issue in non invasivemechanical ventilation (NIV) and leaks at the patient-mask interface play a major role in itspathogenesis. NIV algorithms alleviate the deleterious impact of leaks and improve patient-ventilator interaction. Neurally adusted ventilatory assist (NAVA), a neurally triggered modethat avoids interferences between leaks and the usual pneumatic trigger, could further improvepatient-ventilator interaction in NIV patients.OBJECTIVES. To evaluate the feasibility ofNAVAin patients receiving a prophylactic postextubationNIV and to compare the respective impact ofPSVandNAVAwith and withoutNIValgorithm on patient-ventilator interaction.METHODS. Prospective study conducted in 16 beds adult critical care unit (ICU) in a tertiaryuniversity hospital. Over a 2 months period, were included 17 adult medical ICU patientsextubated for less than 2 h and in whom a prophylactic post-extubation NIV was indicated.Patients were randomly mechanically ventilated for 10 min with: PSV without NIV algorithm(PSV-NIV-), PSV with NIV algorithm (PSV-NIV+),NAVAwithout NIV algorithm (NAVANIV-)and NAVA with NIV algorithm (NAVA-NIV+). Breathing pattern descriptors, diaphragmelectrical activity, leaks volume, inspiratory trigger delay (Tdinsp), inspiratory time inexcess (Tiexcess) and the five main asynchronies were quantified. Asynchrony index (AI) andasynchrony index influenced by leaks (AIleaks) were computed.RESULTS. Peak inspiratory pressure and diaphragm electrical activity were similar in thefour conditions. With both PSV and NAVA, NIV algorithm significantly reduced the level ofleak (p\0.01). Tdinsp was not affected by NIV algorithm but was shorter in NAVA than inPSV (p\0.01). Tiexcess was shorter in NAVA and PSV-NIV+ than in PSV-NIV- (p\0.05).The prevalence of double triggering was significantly lower in PSV-NIV+ than in NAVANIV+.As compared to PSV,NAVAsignificantly reduced the prevalence of premature cyclingand late cycling while NIV algorithm did not influenced premature cycling. AI was not affectedby NIV algorithm but was significantly lower in NAVA than in PSV (p\0.05). AIleaks wasquasi null with NAVA and significantly lower than in PSV (p\0.05).CONCLUSIONS. NAVA is feasible in patients receiving a post-extubation prophylacticNIV. NAVA and NIV improve patient-ventilator synchrony in different manners. NAVANIV+offers the best patient-ventilator interaction. Clinical studies are required to assess thepotential clinical benefit of NAVA in patients receiving NIV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Four different types of internal hernias (IH) are known to occur after laparoscopic Roux-en-Y gastric bypass (LRYGBP) performed for morbid obesity. We evaluate multidetector row helical computed tomography (MDCT) features for their differentiation. METHODS: From a prospectively collected database including 349 patients with LRYGBP, 34 acutely symptomatic patients (28 women, mean age 32.6), operated on for IH immediately after undergoing MDCT, were selected. Surgery confirmed 4 (11.6%) patients with transmesocolic, 10 (29.4%) with Petersen's, 15 (44.2%) with mesojejunal, and 5 (14.8%) with jejunojejunal IH. In consensus, 2 radiologists analyzed 13 MDCT features to distinguish the four types of IH. Statistical significance was calculated (p < 0.05, Fisher's exact test, chi-square test). RESULTS: MDCT features of small bowel obstruction (SBO) (n = 25, 73.5%), volvulus (n = 22, 64.7%), or a cluster of small bowel loops (SBL) (n = 27, 79.4%) were inconsistently present and overlapped between the four IH. The following features allowed for IH differentiation: left upper quadrant clustered small bowel loops (p < 0.0001) and a mesocolic hernial orifice (p = 0.0003) suggested transmesocolic IH. SBL abutting onto the left abdominal wall (p = 0.0021) and left abdominal shift of the superior mesenteric vessels (SMV) (p = 0.0045) suggested Petersen's hernia. The SMV predominantly shifted towards the right anterior abdominal wall in mesojejunal hernia (p = 0.0033). Location of the hernial orifice near the distal anastomosis (p = 0.0431) and jejunojejunal suture widening (p = 0.0005) indicated jejunojejunal hernia. CONCLUSIONS: None of the four IH seems associated with a higher risk of SBO. Certain MDCT features, such as the position of clustered SBL and hernial orifice, help distinguish between the four IH and may permit straightforward surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Syngnathia is an extremely rare condition involving congenital fusion of the maxilla with the mandible. Clinical presentations vary from simple mucosal bands (synechiae) to complete bony fusion (synostosis). Most cases are unilateral incomplete fusions. We report the case of a severely growth-retarded newborn infant with complete synostosis of the mandible with the maxilla and the zygoma associated with cleft palate, choanal atresia, deafness, delayed cerebral white matter development, and genital and limb malformations. Extensive genetic analysis did not reveal any mutations. This association of multiple congenital malformations may represent an entity distinct from previously described syndromes associated with syngnathia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Thyroid ectopy results from the failure of the thyroid precursor cells to migrate from the primordial pharynx to the anterior part of the neck. Most ectopic thyroids are revealed by congenital hypothyroidism and present as a single round mass at the base of the tongue, with no other thyroid tissue. However, some cases have dual ectopy, with part of the tissue having partially migrated. We hypothesized that this occurs more frequently than previously reported.¦METHODS: To determine the prevalence of dual ectopy, we reviewed the pertechnetate scintigraphies of 81 patients with congenital hypothyroidism from thyroid ectopy diagnosed between 2002 and 2011 at our institution.¦RESULTS: We report a series of seven cases (9%) of dual ectopy, representing an incidence ranging from 1:50,000 to 1:70,000.¦CONCLUSIONS: Almost one in 10 cases with congenital hypothyroidism due to thyroid ectopy has dual ectopy. This suggests that two populations of cells diverged at an early stage of development, which may arise from insufficient signaling gradients in surrounding tissues during early organogenesis or may indirectly support the polyclonal nature of the thyroid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Non-invasive monitoring of respiratory muscle function is an area of increasing research interest, resulting in the appearance of new monitoring devices, one of these being piezoelectric contact sensors. The present study was designed to test whether the use of piezoelectric contact (non-invasive) sensors could be useful in respiratory monitoring, in particular in measuring the timing of diaphragmatic contraction.Methods: Experiments were performed in an animal model: three pentobarbital anesthetized mongrel dogs. The motion of the thoracic cage was acquired by means of a piezoelectric contact sensor placed on the costal wall. This signal is compared with direct measurements of the diaphragmatic muscle length, made by sonomicrometry. Furthermore, to assess the diaphragmatic function other respiratory signals were acquired: respiratory airflow and transdiaphragmatic pressure. Diaphragm contraction time was estimated with these four signals. Using diaphragm length signal as reference, contraction times estimated with the other three signals were compared with the contraction time estimated with diaphragm length signal.Results: The contraction time estimated with the TM signal tends to give a reading 0.06 seconds lower than the measure made with the DL signal (-0.21 and 0.00 for FL and DP signals, respectively), with a standard deviation of 0.05 seconds (0.08 and 0.06 for FL and DP signals, respectively). Correlation coefficients indicated a close link between time contraction estimated with TM signal and contraction time estimated with DL signal (a Pearson correlation coefficient of 0.98, a reliability coefficient of 0.95, a slope of 1.01 and a Spearman's rank-order coefficient of 0.98). In general, correlation coefficients and mean and standard deviation of the difference were better in the inspiratory load respiratory test than in spontaneous ventilation tests.Conclusion: The technique presented in this work provides a non-invasive method to assess the timing of diaphragmatic contraction in canines, using a piezoelectric contact sensor placed on the costal wall.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectif Evaluer l'évolution à long-terme d'une population de patients pédiatriques souffrant de sténose aortique congénitale et ayant subi une intervention chirurgicale sur cette valve, et déterminer les facteurs de risques associés à une ré-intervention. Patients et méthode De 1985 à 2009, 77 patients, en moyenne âgés de 5.8 ± 5-6 ans, ont été suivis dans notre Service durant 14.8 ± 9-1 années. Résultats La première intervention montre d'excellents résultats avec 86% des patients ayant un gradient aortique résiduel < 50 mmHg et seulement 7% avec une nouvelle fuite aortique >1. La survie à long terme est de 91% A 25 ans. A un intervalle de 7.6 ± 5-3 ans, 30 patients 011t nécessité une ré-intervention (39%), principalement à cause d'une récidive de la sténose aortique. Le pourcentage de patients libre de ré¬intervention était de 97, 89, 75, 53, and 42% à respectivement 1, 10,15, 20, et 25 ans. Les facteurs de risques cle ré-interventions étaient le gradient aortique residuel plus élevé (p=0.00 01), la fuite aortique post-intervention >1 (p=0.02), la valvuloplasty au ballon préalable (p-0.04) et l'épaisseur augmentée de la paroi postérieure du ventricule gauche (p=o.i). Conclusions L'intervention chirurgicale sur la valve aortique est un procédé sûr et efficace pour les sténoses aortiques congénitales et démontre d'excellents résultats au niveau de la survie. Cependant le taux de ré-intervention est élevé et influencé par le gradient aortique résiduel plus élevé, la fuite aortique post-intervention >1, la valvuloplasty au ballon préalable et l'épaisseur augmentée de la paroi postérieure du ventricule gauche. L'étude démontre qu'un suivi à long-terme est recommandé pour ces patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Prenatal diagnosis has been shown to decrease pre-operative acidosis and might prevent the occurrence of disturbed developmental outcome. The aim of this study is to evaluate parameters for acidosis and their predictive value on developmental outcome in newborns with congenital heart disease. METHODS: A total of 117 patients requiring surgery for structural heart disease in the first 31 days of life were included. Diagnosis was established either pre- or postnatally. Preoperative values of lactate, pH and base excess levels were compared to the occurrence of disturbed developmental outcome, i.e. an underperformance of more than 10% on the P90 of a standardized Dutch developmental scale. Patients were divided into groups according to blood levels of acidosis parameters, using receiver operating characteristics curves to determine cut-off values for pH, base excess and lactate. RESULTS: No significant difference in developmental outcome was found using values for pH or base excess as a cut-off level. Preoperative lactate values exceeding 6.1 mmol/l resulted in a significant increase in impaired development compared to infants with a pre-operative lactate lower than 6.1 mmol/l: 40.9% vs 15.1% in (p=0.03). CONCLUSIONS: Pre-operative lactate values might have a prognostic value on developmental outcome in newborns with congenital heart disease. The limited prognostic value of pH can be explained by the fact that pH can be easily corrected, while lactate better reflects the total oxygen debt experienced by these patients.