987 resultados para blood volume
Resumo:
Obstructive apnea (OA) can exert significant effects on renal sympathetic nerve activity (RSNA) and hemodynamic parameters. The present study focuses on the modulatory actions of RSNA on OA-induced sodium and water retention. The experiments were performed in renal-denervated rats (D; N = 9), which were compared to sham (S; N = 9) rats. Mean arterial pressure (MAP) and heart rate (HR) were assessed via an intrafemoral catheter. A catheter was inserted into the bladder for urinary measurements. OA episodes were induced via occlusion of the catheter inserted into the trachea. After an equilibration period, OA was induced for 20 s every 2 min and the changes in urine, MAP, HR and RSNA were recorded. Renal denervation did not alter resting MAP (S: 113 ± 4 vs D: 115 ± 4 mmHg) or HR (S: 340 ± 12 vs D: 368 ± 11 bpm). An OA episode resulted in decreased HR and MAP in both groups, but D rats showed exacerbated hypotension and attenuated bradycardia (S: -12 ± 1 mmHg and -16 ± 2 bpm vs D: -16 ± 1 mmHg and 9 ± 2 bpm; P < 0.01). The basal urinary parameters did not change during or after OA in S rats. However, D rats showed significant increases both during and after OA. Renal sympathetic nerve activity in S rats increased (34 ± 9%) during apnea episodes. These results indicate that renal denervation induces elevations of sodium content and urine volume and alters bradycardia and hypotension patterns during total OA in unconscious rats.
Resumo:
OBJECTIVE: The assessment of an easy to prepare and low cost control material for Hematology, available for manual and automated methods. MATERIAL AND METHOD: Aliquots of stabilized whole blood were prepared by partial fixation with aldehydes; the stability at different temperatures (4. 20 and 37 °C) during periods of up to 8-9 weeks and aliquot variability with both methods were controlled. RESULTS: Aliquot variability with automated methods at day 1, expressed as CV% (coefficient of variation) was: white blood cells (WBC) 2.7, red blood cells (RBC) 0.7, hemoglobin (Hb) 0.6, hematocrit (Hct) 0.7, mean cell volume (MCV) 0.3, mean cell hemoglobin (MCH) 0.6, mean cell hemoglobin concentration (MCHC) 0.7, and platelets (PLT) 4.6. The CV (coefficient of variation) percentages obtained with manual methods in one of the batches were: WBC 23, Hct 2.8, Hb 4.5, MCHC 5.9, PLT 41. Samples stored at 4ºC and 20ºC showed good stability, only a very low initial hemolysis being observed, whereas those stored at 37ºC deteriobed a rapidly (metahemoglobin formation, aggregation of WBC and platelets, as well as alteration of erythrocyte indexes). CONCLUSIONS: It was confirmed that, as long as there is no exposure to high temperatures during distribution, this material is stable, allowing assessment, both esternal and internal, for control purposes, with acceptable reproductivity, both for manual and auttomatic methods.
Resumo:
The sand fly Lutzomyia cruzi is considered as one of vectors of visceral leishmaniasis in Brazil. This work examined optimum feeding age, feeding time, host preference, fecundity rates, and female blood meal volume taken by single females from a closed colony of L. cruzi. Mean feeding time was longer on hamsters, 6.6 minutes, than on humans, 5.7 minutes. 49.1% of the 48h-old flies fed on humans and 43.3% of 72h-old flies fed on hamsters. Of a total of 120 females, 61% fed on humans and 25% fed on hamsters. Total fecundity was significantly higher in females fed on hamster than on human or opossum. Laboratory-reared L. cruzi females fed earlier, more promptly, and preferably on humans than on hamsters when offered these blood-meal sources simultaneously. The blood-meal volume is higher in females fed on hamsters than other hosts (human and opossum).
Resumo:
Background:Left atrial volume (LAV) is a predictor of prognosis in patients with heart failure.Objective:We aimed to evaluate the determinants of LAV in patients with dilated cardiomyopathy (DCM).Methods:Ninety patients with DCM and left ventricular (LV) ejection fraction ≤ 0.50 were included. LAV was measured with real-time three-dimensional echocardiography (eco3D). The variables evaluated were heart rate, systolic blood pressure, LV end-diastolic volume and end-systolic volume and ejection fraction (eco3D), mitral inflow E wave, tissue Doppler e´ wave, E/e´ ratio, intraventricular dyssynchrony, 3D dyssynchrony index and mitral regurgitation vena contracta. Pearson´s coefficient was used to identify the correlation of the LAV with the assessed variables. A multiple linear regression model was developed that included LAV as the dependent variable and the variables correlated with it as the predictive variables.Results:Mean age was 52 ± 11 years-old, LV ejection fraction: 31.5 ± 8.0% (16-50%) and LAV: 39.2±15.7 ml/m2. The variables that correlated with the LAV were LV end-diastolic volume (r = 0.38; p < 0.01), LV end-systolic volume (r = 0.43; p < 0.001), LV ejection fraction (r = -0.36; p < 0.01), E wave (r = 0.50; p < 0.01), E/e´ ratio (r = 0.51; p < 0.01) and mitral regurgitation (r = 0.53; p < 0.01). A multivariate analysis identified the E/e´ ratio (p = 0.02) and mitral regurgitation (p = 0.02) as the only independent variables associated with LAV increase.Conclusion:The LAV is independently determined by LV filling pressures (E/e´ ratio) and mitral regurgitation in DCM.
Resumo:
PURPOSE: To understand the reasons for differences in the delineation of target volumes between physicians. MATERIAL AND METHODS: 18 Swiss radiooncology centers were invited to delineate volumes for one prostate and one head-and-neck case. In addition, a questionnaire was sent to evaluate the differences in the volume definition (GTV [gross tumor volume], CTV [clinical target volume], PTV [planning target volume]), the various estimated margins, and the nodes at risk. Coherence between drawn and stated margins by centers was calculated. The questionnaire also included a nonspecific series of questions regarding planning methods in each institution. RESULTS: Fairly large differences in the drawn volumes were seen between the centers in both cases and also in the definition of volumes. Correlation between drawn and stated margins was fair in the prostate case and poor in the head-and-neck case. The questionnaire revealed important differences in the planning methods between centers. CONCLUSION: These large differences could be explained by (1) a variable knowledge/interpretation of ICRU definitions, (2) variable interpretations of the potential microscopic extent, (3) difficulties in GTV identification, (4) differences in the concept, and (5) incoherence between theory (i.e., stated margins) and practice (i.e., drawn margins).
Resumo:
Red blood cell (RBC) parameters such as morphology, volume, refractive index, and hemoglobin content are of great importance for diagnostic purposes. Existing approaches require complicated calibration procedures and robust cell perturbation. As a result, reference values for normal RBC differ depending on the method used. We present a way for measuring parameters of intact individual RBCs by using digital holographic microscopy (DHM), a new interferometric and label-free technique with nanometric axial sensitivity. The results are compared with values achieved by conventional techniques for RBC of the same donor and previously published figures. A DHM equipped with a laser diode (lambda = 663 nm) was used to record holograms in an off-axis geometry. Measurements of both RBC refractive indices and volumes were achieved via monitoring the quantitative phase map of RBC by means of a sequential perfusion of two isotonic solutions with different refractive indices obtained by the use of Nycodenz (decoupling procedure). Volume of RBCs labeled by membrane dye Dil was analyzed by confocal microscopy. The mean cell volume (MCV), red blood cell distribution width (RDW), and mean cell hemoglobin concentration (MCHC) were also measured with an impedance volume analyzer. DHM yielded RBC refractive index n = 1.418 +/- 0.012, volume 83 +/- 14 fl, MCH = 29.9 pg, and MCHC 362 +/- 40 g/l. Erythrocyte MCV, MCH, and MCHC achieved by an impedance volume analyzer were 82 fl, 28.6 pg, and 349 g/l, respectively. Confocal microscopy yielded 91 +/- 17 fl for RBC volume. In conclusion, DHM in combination with a decoupling procedure allows measuring noninvasively volume, refractive index, and hemoglobin content of single-living RBCs with a high accuracy.
Resumo:
BACKGROUND: For over 50 years, radiocephalic wrist arteriovenous fistulae (RCAVF) have been the primary and best vascular access for haemodialysis. Nevertheless, early failure due to thrombosis or non-maturation is a major complication resulting in their abandonment. This prospective study was designed to investigate the predictive value of intra-operative blood flow on early failure of primary RCAVF before the first effective dialysis. METHODS: We enrolled patients undergoing creation of primary RCAVF for haemodialysis based on the pre-operative ultrasound vascular mapping discussed in a multidisciplinary approach. Intra-operative blood flow measurement was systematically performed once the anastomosis had been completed using a transit-time ultrasonic flowmeter. During the follow-up, blood flow was estimated by colour flow ultrasound at various intervals. Any events related to the RCAVF were recorded. RESULTS: Autogenous RCAVFs (n = 58) in 58 patients were constructed and followed up for an average of 30 days. Thrombosis and non-maturation occurred in eight (14%) and four (7%) patients, respectively. The intra-operative blood flow in functioning RCAVFs was significantly higher compared to non-functioning RCAVFs (230 vs 98 mL/min; P = 0.007), as well as 1 week (753 vs 228 mL/min; P = 0.0008) and 4 weeks (915 vs 245 mL/min, P < 0.0001) later. Blood flow volume measurements with a cut-off value of 120 mL/min had a sensitivity of 67%, specificity of 75% and positive predictive value of 91%. CONCLUSIONS: Blood flow <120 mL has a good predictive value for early failure in RCAVF. During the procedure, this cut-off value may be used to select appropriately which RCAVF should be investigated in the operation theatre in order to correct in real time any abnormality.
Resumo:
Background: Previous studies reported an increase of mean platelet volume (MPV) in patients with acute ischemic stroke. However, its correlation with stroke severity has not been investigated. Moreover, studies on the association of MPV with functional outcome yielded inconsistent results. Methods: We included all consecutive ischemic stroke patients admitted to CHUV (Centre Hospitalier Universitaire Vaudois) Neurology Service within 24 h after stroke onset who had MPV measured on admission. The association of MPV with stroke severity (NIHSS score at admission and at 24 h) and outcome (Rankin Scale score at 3 and 12 months) was analyzed in univariate analysis. The chi(2) test was performed to compare the frequency of minor strokes (NIHSS score </=4) and good functional outcome (Rankin Scale score </=2) across MPV quartiles. The ANOVA test was used to compare MPV between stroke subtypes according to the TOAST classification. Student's two-tailed unpaired t test was performed to compare MPV between lacunar and nonlacunar strokes. MPV was generated at admission by the Sysmex XE-2100 automated cell counter (Sysmex Corporation, Kobe, Japan) from EDTA blood samples. Results: There was no significant difference in the frequency of minor strokes (p = 0.46) and good functional outcome (p = 0.06) across MPV quartiles. MPV was not associated with stroke severity or outcome in univariate analysis. There was no significant difference in MPV between stroke subtypes according to the TOAST classification (p = 0.173) or between lacunar and nonlacunar strokes (10.50 +/- 0.91 vs. 10.40 +/- 0.81 fl, p = 0.322). Conclusions: MPV, assessed within 24 h after ischemic stroke onset, is not associated with stroke severity or functional outcome.
Resumo:
PURPOSE: Visualization of coronary blood flow by means of a slice-selective inversion pre-pulse in concert with bright-blood coronary MRA. MATERIALS AND METHODS: Coronary magnetic resonance angiography (MRA) of the right coronary artery (RCA) was performed in eight healthy adult subjects on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Medical Systems, Best, NL) using a free-breathing navigator-gated and cardiac-triggered 3D steady-state free-precession (SSFP) sequence with radial k-space sampling. Imaging was performed with and without a slice-selective inversion pre-pulse, which was positioned along the main axis of the coronary artery but perpendicular to the imaging volume. Objective image quality parameters such as SNR, CNR, maximal visible vessel length, and vessel border definition were analyzed. RESULTS: In contrast to conventional bright-blood 3D coronary MRA, the selective inversion pre-pulse provided a direct measure of coronary blood flow. In addition, CNR between the RCA and right ventricular blood pool was increased and the vessels had a tendency towards better delineation. Blood SNR and CNR between right coronary blood and epicardial fat were comparable in both sequences. CONCLUSION: The combination of a free-breathing navigator-gated and cardiac-triggered 3D SSFP sequence with a slice-selective inversion pre-pulse allows for direct and directional visualization of coronary blood flow with the additional benefit of improved contrast between coronary and right ventricular blood pool.
Resumo:
The increase of the body's capacity to transport oxygen is a prime target for doping athletes in all endurance sports. For this pupose, blood transfusions or erythropoiesis stimulating agents (ESA), such as erythropoietin, NESP, and CERA are used. As direct detection of such manipulations is difficult, biomarkers that are connected to the haematopoietic system (haemoglobin concentration, reticulocytes) are monitored over time (Athlete Biological Passport (ABP)) and analyzed using mathematical models to identify patterns suspicious of doping. With this information, athletes can either be sanctioned directly based on their profile or targeted with conventional doping tests. Key issues for the appropriate use of the ABP are correct targeting and use of all available information (e.g. whereabouts, cross sectional population data) in a forensic manner. Future developments of the passport include the correction of all concentration-based variables for shifts in plasma volume, which might considerably increase sensitivity. New passport markers from the genomic, proteomic, and metabolomic level might add further information, but need to be validated before integration into the passport procedure. A first assessment of blood data of federations that have implemented the passport show encouraging signs of a decreased blood-doping prevalence in their athletes, which adds scientific credibility to this innovative concept in the fight against ESA- and blood doping. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
Digital holographic microscopy (DHM) is a technique that allows obtaining, from a single recorded hologram, quantitative phase image of living cell with interferometric accuracy. Specifically the optical phase shift induced by the specimen on the transmitted wave front can be regarded as a powerful endogenous contrast agent, depending on both the thickness and the refractive index of the sample. Thanks to a decoupling procedure cell thickness and intracellular refractive index can be measured separately. Consequently, Mean corpuscular volume (MCV) and mean corpuscular hemoglobin concentration (MCHC), two highly relevant clinical parameters, have been measured non-invasively at a single cell level. The DHM nanometric axial and microsecond temporal sensitivities have permitted to measure the red blood cell membrane fluctuations (CMF) on the whole cell surface. ©2009 COPYRIGHT SPIE--The International Society for Optical Engineering.
Resumo:
In spite of its widespread use, benznidazole's (BNZ) toxicity and low efficacy remains as major drawbacks that impair successful treatments against Chagas disease. Previously, attempting to increase the selectivity and reduce its toxicity on infected tissues, multilamellar liposomes (MLV) composed of hydrogenated soybean phosphatidylcholine (HSPC): distearoyl-phosphatidylglycerol (DSPG): cholesterol (CHOL) 2:1:2 mol:mol loaded with BNZ (MLV-BNZ) were designed. In this work we compared different properties of MLV-BNZ with those of BNZ. Opposite to other hydrophobic drugs, the results indicated that slight changes of BNZ×s association degree to proteins and lipoproteins should not modify the percentage of unbound drug available to exert pharmacological action. On the other hand, when loaded in MLV, BNZ reduced its association to plasma proteins in 45% and became refractory to the sinking effect of blood, dropping 4.5 folds. Additionally, when loaded in MLV, BNZ had higher volume distribution (160 ± 20 vs 102 ± 15 ml/kg) and total clearance (35.23 ± 2.3 vs 21.9 ± 1.4 ml/h.kg), and lower concentration-time curve (7.23 ± 0.2 vs 9.16 ± 0.5 µg.h/ml) than BNZ. Hence, these studies showed that for MLV-BNZ, the amount of BNZ can be substantially increased, from 25 to 70%, being this formulation more rapidly cleared from circulation than free drug; also due to the lower interaction with blood components, lower side effects can be expected.
Resumo:
The Atripump is a motorless, volume displacement pump based on artificial muscle technology that could reproduce the pump function of normal atrium. It could help prevent blood clots due to blood stagnation and eventually avoid anticoagulation therapy in atrial fibrillation (AF). An animal study has been designed to assess mechanical effects of this pump on fibrillating atrium. The Atripump is a dome shaped silicone coated nitinol actuator. A pacemaker like control unit drives the actuator. In five adult sheep, the right atrium (RA) was exposed and dome sutured onto the epicardium. Atrial fibrillation was induced using rapid epicardial pacing (600 beats/min). Ejection fraction of the RA was obtained with intracardiac ultrasound in baseline, AF and Atripump assisted AF conditions. The dome's contraction rate was 60/min with power supply of 12V, 400 mA for 200 ms and ran for 2 hours in total. Mean temperature on the RA was 39+/-1.5 degrees C. Right atrium ejection fraction was 31% in baseline conditions, 5% and 20% in AF and assisted AF, respectively. In two animals a thrombus appeared in the right appendix and washed out once the pump was turned on. The Atripump washes blood out the RA acting as an anticoagulant device. Possible clinical implications in patients with chronic AF are prevention of embolism of cardiac origin and avoidance of hemorrhagic complication due to chronic anticoagulation.
Resumo:
Numerous trials have reported that some haematological and biochemical parameters could be put together and be used to detect and fight recombinant erythropoietin doping. Unfortunately, none of the studies mentioned the necessity of taking pre-analytical precautions to avoid possible suspicious results coming from major plasma volume changes caused notably by dehydration. Therefore we studied the behaviour of the most common secondary blood markers before and after a strenuous physical activity to find out how reliable these parameters were. The soluble transferrin receptor and the haemoglobin concentrations as well as the haematocrit level increased significantly after effort, whereas the plasma EPO concentration and the reticulocyte count remained constant. On the other hand, if the values were corrected for haemoconcentration, the soluble transferrin receptor concentration remained stable.
Resumo:
INTRODUCTION Hemodynamic resuscitation should be aimed at achieving not only adequate cardiac output but also sufficient mean arterial pressure (MAP) to guarantee adequate tissue perfusion pressure. Since the arterial pressure response to volume expansion (VE) depends on arterial tone, knowing whether a patient is preload-dependent provides only a partial solution to the problem. The objective of this study was to assess the ability of a functional evaluation of arterial tone by dynamic arterial elastance (Ea(dyn)), defined as the pulse pressure variation (PPV) to stroke volume variation (SVV) ratio, to predict the hemodynamic response in MAP to fluid administration in hypotensive, preload-dependent patients with acute circulatory failure. METHODS We performed a prospective clinical study in an adult medical/surgical intensive care unit in a tertiary care teaching hospital, including 25 patients with controlled mechanical ventilation who were monitored with the Vigileo(®) monitor, for whom the decision to give fluids was made because of the presence of acute circulatory failure, including arterial hypotension (MAP ≤65 mmHg or systolic arterial pressure <90 mmHg) and preserved preload responsiveness condition, defined as a SVV value ≥10%. RESULTS Before fluid infusion, Ea(dyn) was significantly different between MAP responders (MAP increase ≥15% after VE) and MAP nonresponders. VE-induced increases in MAP were strongly correlated with baseline Ea(dyn) (r(2) = 0.83; P < 0.0001). The only predictor of MAP increase was Ea(dyn) (area under the curve, 0.986 ± 0.02; 95% confidence interval (CI), 0.84-1). A baseline Ea(dyn) value >0.89 predicted a MAP increase after fluid administration with a sensitivity of 93.75% (95% CI, 69.8%-99.8%) and a specificity of 100% (95% CI, 66.4%-100%). CONCLUSIONS Functional assessment of arterial tone by Ea(dyn), measured as the PVV to SVV ratio, predicted arterial pressure response after volume loading in hypotensive, preload-dependent patients under controlled mechanical ventilation.