950 resultados para accuracy of estimation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigated the influence of age, familiarity, and level of exposure on the metamemorial skill of prediction accuracy on a future test. Young (17 to 23 years old) and middle-aged adults (35 to 50 years old) were asked to predict their memory for text material. Participants made predictions on a familiar text and an unfamiliar text, at three different levels of exposure to each. The middle-aged adults were superior to the younger adults at predicting performance. This finding indicates that metamemory may increase from youth to middle age. Other findings include superior prediction accuracy for unfamiliar compared to familiar material, a result conflicting with previous findings, and an interaction between level of exposure and familiarity that appears to modify the main effects of those variables.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives  To determine the diagnostic accuracy of World Health Organization (WHO) 2010 and 2006 as well as United States Department of Health and Human Services (DHHS) 2008 definitions of immunological failure for identifying virological failure (VF) in children on antiretroviral therapy (ART). Methods  Analysis of data from children (<16 years at ART initiation) at South African ART sites at which CD4 count/per cent and HIV-RNA monitoring are performed 6-monthly. Incomplete virological suppression (IVS) was defined as failure to achieve ≥1 HIV-RNA ≤400 copies/ml between 6 and 15 months on ART and viral rebound (VR) as confirmed HIV-RNA ≥5000 copies/ml in a child on ART for ≥18 months who had achieved suppression during the first year on treatment. Results  Among 3115 children [median (interquartile range) age 48 (20-84) months at ART initiation] on treatment for ≥1 year, sensitivity of immunological criteria for IVS was 10%, 6% and 26% for WHO 2006, WHO 2010 and DHHS 2008 criteria, respectively. The corresponding positive predictive values (PPV) were 31%, 20% and 20%. Diagnostic accuracy for VR was determined in 2513 children with ≥18 months of follow-up and virological suppression during the first year on ART with sensitivity of 5% (WHO 2006/2010) and 27% (DHHS 2008). PPV results were 42% (WHO 2010), 43% (WHO 2006) and 20% (DHHS 2008). Conclusion  Current immunological criteria are unable to correctly identify children failing ART virologically. Improved access to viral load testing is needed to reliably identify VF in children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to simulate pulmonary emboli (PE) and image quality at low tube energy and reduced contrast material volume in normal-dose pulmonary CT angiography (CTA) images and to analyze the diagnostic accuracy with normal- and low-dose pulmonary CTA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To show the effect of standard magnetic resonance imaging (MRI) in patients with suspected appendicitis on negative laparotomy and perforation rate. Moreover, the economic impact on hospital resources was evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background and Aims: Data on the influence of calibration on accuracy of continuous glucose monitoring (CGM) are scarce. The aim of the present study was to investigate whether the time point of calibration has an influence on sensor accuracy and whether this effect differs according to glycemic level. Subjects and Methods: Two CGM sensors were inserted simultaneously in the abdomen on either side of 20 individuals with type 1 diabetes. One sensor was calibrated predominantly using preprandial glucose (calibration(PRE)). The other sensor was calibrated predominantly using postprandial glucose (calibration(POST)). At minimum three additional glucose values per day were obtained for analysis of accuracy. Sensor readings were divided into four categories according to the glycemic range of the reference values (low, ≤4 mmol/L; euglycemic, 4.1-7 mmol/L; hyperglycemic I, 7.1-14 mmol/L; and hyperglycemic II, >14 mmol/L). Results: The overall mean±SEM absolute relative difference (MARD) between capillary reference values and sensor readings was 18.3±0.8% for calibration(PRE) and 21.9±1.2% for calibration(POST) (P<0.001). MARD according to glycemic range was 47.4±6.5% (low), 17.4±1.3% (euglycemic), 15.0±0.8% (hyperglycemic I), and 17.7±1.9% (hyperglycemic II) for calibration(PRE) and 67.5±9.5% (low), 24.2±1.8% (euglycemic), 15.5±0.9% (hyperglycemic I), and 15.3±1.9% (hyperglycemic II) for calibration(POST). In the low and euglycemic ranges MARD was significantly lower in calibration(PRE) compared with calibration(POST) (P=0.007 and P<0.001, respectively). Conclusions: Sensor calibration predominantly based on preprandial glucose resulted in a significantly higher overall sensor accuracy compared with a predominantly postprandial calibration. The difference was most pronounced in the hypo- and euglycemic reference range, whereas both calibration patterns were comparable in the hyperglycemic range.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Glial fibrillary acidic protein (GFAP) is a biomarker candidate indicative of intracerebral hemorrhage (ICH) in patients with symptoms of acute stroke. GFAP is released rapidly in the presence of expanding intracerebral bleeding, whereas a more gradual release occurs in ischemic stroke. In this study the diagnostic accuracy of plasma GFAP was determined in a prospective multicenter approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Helicopter emergency medical services (HEMSs) have become a standard element of modern prehospital emergency medicine. This study determines the percentage of injured HEMS patients whose injuries were correctly recognized by HEMS physicians.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To assess the ability of low-dose CT to detect and characterize the most common CT patterns of pulmonary disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A variety of research has documented high levels of depression among older adults in the health care setting. Additional research has shown that care providers in health care settings are not very effective at diagnosing comorbid depression.This is a troublesome finding since comorbid depression has been linked to a number of negative outcomes in older adults. Early results have indicated that comorbid depression may be associated with a number of unfavorable consequences ranging from impairments in physical functioning to increased mortality.The health care setting with arguably the highest rate of physical impairment is the nursing home and it is the nursing home where the effects of comorbid depression may be most costly. Therefore, the current analysis uses data from the Institutional Population Component of the NationalMedical Expenditure Survey (US Department of Health and Human Services, 1990) to explore rates of both recognized and unrecognized comorbid depression in the nursing home setting. Using a constructed proxy variable representative of the DSM-III-R diagnosis of depression, results indicate that approximately 8.1% of nursing home residents have an unrecognized potential comorbid depression.