992 resultados para WF 668
Resumo:
A new compound [H(2)en](2)[H3O](6)[Co(H2O)(2)(VO)(8)(OH)(4)(PO4)(8)] has been hydrothermally synthesized. Single crystal X-ray analysis indicates that this compound crystallizes in a monoclinic system, space group P2(1)/n with a=1.438 5(3) nm, b=1.012 2(2) nm, c=1.832 5(4) nm, beta=90.21degrees, V=2.668 2 (9) nm(3), Z = 2, D-c = 2.112 g/cm(3), R = 0.055, wR = 0.149 7, S = 1.037. The structure of [H(2)en](2)[H3O](6)[Co(H2O)(2)(VO)(8)(OH)(4)(PO4)(8)] is characterized by P-V-O layers constructed by [(VO)4 (OH)(2)(PO4)(4)](6-) non-symmetric units. The P-V-O layers are pillared by [Co(H2O)(2)](2+) group, resulting in the channels within which the protonated diaminoethane and H3O+ are located.
Resumo:
The graft copolymer of high impact polystyrene (HIPS) grafted with malice anhydride (MA) (HIPS-g-MA) was prepared with melt mixing in the presence of a free-radical initiator. The grafting reaction was confirmed by IR analyses and the amount of MA grafted on HIPS was evaluated by a titration method. 1-5 wt% of MA can be grafted on HIPS. HIPS-g-MA is miscible with HIPS. Its anhydride group can react with the PA6 during melt mixing the two components. The compatibility of HIPS-g-MA in the HIPS/PA6 blends was evident. Evidence of reactions in the blends was confirmed in the morphology and mechanical properties of the blends. A significant reduction in domain size was observed because of the compatibilization of HIPS-g-MA in the blends of HIPS and PA6. The tensile mechanical properties of the prepared blends were investigated and the fracture surfaces of the blends were examined by means of the scanning electron microscope (SEM). The improved adhesion in a 16%HIPS/75%PA6 blend with 9%HIPS-g-MA copolymer was detected. The morphology of fibrillar ligaments formed by PA6 connecting HIPS particles was observed.
Resumo:
The structure and thermal properties of polyamide-1010 (PA1010), treated at 250degreesC for 30 min under pressures of 0.7-2.5 GPa, were studied with wide-angle X-ray diffraction (WAXD), infrared (IR), differential scanning calorimetry (DSC), and thermogravimetric analysis (TGA). Crystals were formed when the pressures were less than 1.0 GPa or greater than 1.2 GPa. With increasing pressure, the intensity of the diffraction peak at approximately 24degrees was enhanced, whereas the peak at approximately 20degrees was depressed. The triclinic crystal structure of PA1010 was preserved. The highest melting temperature of the crystals obtained in this work was 208degreesC for PA1010 treated at 1.5 GPa. Crosslinking occurred under pressures of 1.0-1.2 GPa. Only a broad diffraction peak centered at approximately 20degrees was observed on WAXD patterns, and no melting and crystallization peaks were found on DSC curves. IR spectra of crosslinked PA1010 showed a remarkable absorption band at 1370 cm(-1). The N-H stretching vibration band at 3305 cm(-1) was weakened. Crystallized PA1010 had a higher thermal stability than crosslinked PA1010, as indicated on TGA curves by a higher onset temperature of decomposition.
Resumo:
量子尺寸氧化锌是重要的氧化物半导体材料之一 ,文中简单介绍了它的溶胶法制备及粒子生长和聚集过程 ,着重阐述了其光学性质研究现状和光致发光机理 ,并展望了未来的发展方向。
Resumo:
The paper studies the morphology and mechanical properties of immiscible binary blends of the nylon 1010 and HIPS through the radiation crosslinking method. In this blend, the HIPS particles were the dispersed phases in the nylon 1010 matrix. With increasing of dose, the elastic modulus increased, However, the tensile strength. elongation at bleak and the energy of fracture increased to a maximum at a dose of 0.34 MGy, then reduced with the increasing of dose. SEM photographs show that the hole sizes are not changed obviously at low dose and at high dose, remnants that cannot be dissolved in formic acid and THF can be observed in the holes and on the surface. TEM photographs showed that radiation destroys the rubber phases in the polymer blend. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
Effects of La3+ and Gd3+ on Ca2+ influx were investigated in rat hepatoma H-35 cells by measuring the initial rate of Ca-45(2+) uptake. It was found that the maximum initial rate of Ca2+ uptake was increased six- to ten-fold at low concentrations of La3+ and Gd3+. Kinetic analyses by measuring the initial rate of Ca2+ influx at different external Ca2+ concentrations indicated the existence of two intracellular exchangeable components in the basal Ca2+ system, with low and high affinities for Ca2+, and only one class of Ca2+ binding sites was observed in the La3+- or Gd3+-treated cells. For high affinity, La3+ and Gc(3+) increased both kinetic parameters K-m and V-max of basal Ca2+ influx. La3+ and Gd3+ compete directly with Ca2+ for Ca2+ binding site for low affinity. The kinetics is competitive.
Resumo:
[La(NO3)(3)(OH2)(2)(phen)]. 15-crown-5 is hexagonal, P6(5), with a = 10.955(2), c = 43.769(9) Angstrom, and D-calc = 1.668 g cm(-3) for Z = 6. In the complex, two nitrogen atoms (from phen) and eight oxygen atoms (six from three bidentate nitrate anions and two from water molecules) are coordinated to the central La(III) ion, forming a coordination polyhedron which is approximately a bicapped square antiprism. The coordinated water molecules donate hydrogen bonds to the oxygen atoms of the crown ether, forming polymeric hydrogen bonded chains which wrap helically along the unit cell direction c.
Resumo:
Using two methods: (1) three-step excitation and (2) single UV photon excitation in an atomic beam with direct observation of the decay of the fluorescence light, we have measured the lifetimes of the Rydberg levels of YbI belonging to the perturbed series 6snp J = 1 levels. The measured values have been interpreted by the multichannel quantum defect theory (MQDT).
Resumo:
In chemical ionization mass spectrometry (CIMS) gas phase C-60(+) or C-60 can react with fragment ions from three chloromethane and four multichloroethane molecular ions via ion-molecule reactions. A dozen of gas-phase adduct ions of C-60 are observed, and most of them contain chlorine atoms. The results of the comparison and analysis show that the relative intensities of adductions are not directly proportional to the corresponding fragment ions in the MS of reagents,which implies that some fragment ions containing radicals are more reactive with C-60(+) or C-60. This indicates that the alkene-like C-60(+) or C-60 can act as a radical sponge in addition reactions.
Resumo:
A wall-jet cell/carbon fibre microelectrode detector was designed and used for the micellar liquid chromatographic assay of acetaminophen. The separations were carried out in an analytical column packed with C-18 stationary phase and the mobile phase was
Resumo:
A novel wall-jet cell with parallel dual cylinder (PDC) microelectrodes was constructed and used for flow injection analysis (FLA). The detector takes the advantages of ''redox recycling'' between bipotentiostated microcylinder electrodes (- 0.4 V/SCE an
Resumo:
A novel device of multiple cylinder microelectrodes coupled with a parallel planar electrode was proposed. The feedback diffusion current at this device was studied using bilinear transformation of coordinates in the diffusion space, where lines of mass flux and equiconcentration are represented by orthogonal circular functions. The derived expression for the steady-state current shows that as the gap between cylindrical microelectrodes and planar electrode diminishes, greatly enhanced currents can be obtained with high signal-to-noise ratio. Other important geometrical parameters such as distance between adjacent microcylinders, cylinder radius, and number of microcylinders were also discussed in detail.
Resumo:
A multi-cylinder microelectrode coupled with a conventional glassy carbon disc electrode (MCM/GC) was prepared and characterized using cyclic voltammetry and chronoamperometry. It was demonstrated that in the same way as one observed a steady-state current at closely spaced microelectrodes when redox recycling takes place, the same effect can be obtained with the MCM/GC device. The experimental results obtained with K3Fe(CN)6 solutions were compared with a previously developed theory. Further, it was demonstrated that with a carbon fibre MCM/GC device, the voltammetric behaviour of dopamine is greatly improved by virtue of redox recycling, hence giving high sensitivity. The steady-state collection current was linearly related to dopamine concentration in the range 1 X 10(-4) to 5 x 10(-7) Mol l-1, and the detection limit was 2 x 10(-7) mol l-1. The influence of coexisting ascorbic acid was also investigated. This device was applied successfully in the determination of dopamine hydrochloride in pharmaceutical preparations.