957 resultados para VeriStand, Custom devices, Hardware in the loop, LabView, FPGA, ECU


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the plant-beneficial bacterium Pseudomonas fluorescens CHA0, the expression of antifungal exoproducts is controlled by the GacS/GacA two-component system. Two RNA binding proteins (RsmA, RsmE) ensure effective translational repression of exoproduct mRNAs. At high cell population densities, GacA induces three small RNAs (RsmX, RsmY, RsmZ) which sequester both RsmA and RsmE, thereby relieving translational repression. Here we systematically analyse the features that allow the RNA binding proteins to interact strongly with the 5' untranslated leader mRNA of the P. fluorescens hcnA gene (encoding hydrogen cyanide synthase subunit A). We obtained evidence for three major RsmA/RsmE recognition elements in the hcnA leader, based on directed mutagenesis, RsmE footprints and toeprints, and in vivo expression data. Two recognition elements were found in two stem-loop structures whose existence in the 5' leader region was confirmed by lead(II) cleavage analysis. The third recognition element, which overlapped the hcnA Shine-Dalgarno sequence, was postulated to adopt either an open conformation, which would favour ribosome binding, or a stem-loop structure, which may form upon interaction with RsmA/RsmE and would inhibit access of ribosomes. Effective control of hcnA expression by the Gac/Rsm system appears to result from the combination of the three appropriately spaced recognition elements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For the detection and management of osteoporosis and osteoporosis-related fractures, quantitative ultrasound (QUS) is emerging as a relatively low-cost and readily accessible alternative to dual-energy X-ray absorptiometry (DXA) measurement of bone mineral density (BMD) in certain circumstances. The following is a brief, but thorough review of the existing literature with respect to the use of QUS in 6 settings: 1) assessing fragility fracture risk; 2) diagnosing osteoporosis; 3) initiating osteoporosis treatment; 4) monitoring osteoporosis treatment; 5) osteoporosis case finding; and 6) quality assurance and control. Many QUS devices exist that are quite different with respect to the parameters they measure and the strength of empirical evidence supporting their use. In general, heel QUS appears to be most tested and most effective. Overall, some, but not all, heel QUS devices are effective assessing fracture risk in some, but not all, populations, the evidence being strongest for Caucasian females over 55 years old. Otherwise, the evidence is fair with respect to certain devices allowing for the accurate diagnosis of likelihood of osteoporosis, and generally fair to poor in terms of QUS use when initiating or monitoring osteoporosis treatment. A reasonable protocol is proposed herein for case-finding purposes, which relies on a combined assessment of clinical risk factors (CR.F) and heel QUS. Finally, several recommendations are made for quality assurance and control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

SIRT1 is a NAD(+)-dependent deacetylase that governs a number of genetic programs to cope with changes in the nutritional status of cells and organisms. Behavioral responses to food abundance are important for the survival of higher animals. Here we used mice with increased or decreased brain SIRT1 to show that this sirtuin regulates anxiety and exploratory drive by activating transcription of the gene encoding the monoamine oxidase A (MAO-A) to reduce serotonin levels in the brain. Indeed, treating animals with MAO-A inhibitors or selective serotonin reuptake inhibitors (SSRIs) normalized anxiety differences between wild-type and mutant animals. SIRT1 deacetylates the brain-specific helix-loop-helix transcription factor NHLH2 on lysine 49 to increase its activation of the MAO-A promoter. Both common and rare variations in the SIRT1 gene were shown to be associated with risk of anxiety in human population samples. Together these data indicate that SIRT1 mediates levels of anxiety, and this regulation may be adaptive in a changing environment of food availability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

TWEAK (TNF homologue with weak apoptosis-inducing activity) and Fn14 (fibroblast growth factor-inducible protein 14) are members of the tumor necrosis factor (TNF) ligand and receptor super-families. Having observed that Xenopus Fn14 cross-reacts with human TWEAK, despite its relatively low sequence homology to human Fn14, we examined the conservation in tertiary fold and binding interfaces between the two species. Our results, combining NMR solution structure determination, binding assays, extensive site-directed mutagenesis and molecular modeling, reveal that, in addition to the known and previously characterized β-hairpin motif, the helix-loop-helix motif makes an essential contribution to the receptor/ligand binding interface. We further discuss the insight provided by the structural analyses regarding how the cysteine-rich domains of the TNF receptor super-family may have evolved over time. DATABASE: Structural data are available in the Protein Data Bank/BioMagResBank databases under the accession codes 2KMZ, 2KN0 and 2KN1 and 17237, 17247 and 17252. STRUCTURED DIGITAL ABSTRACT: TWEAK binds to hFn14 by surface plasmon resonance (View interaction) xeFn14 binds to TWEAK by enzyme linked immunosorbent assay (View interaction) TWEAK binds to xeFn14 by surface plasmon resonance (View interaction) hFn14 binds to TWEAK by enzyme linked immunosorbent assay (View interaction).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the major changes introduced in the GPLv3 and LGPLv3 is the clause preventing "tivoisation". Richard Stallman defines Tivoisation as "the practice of designing hardware so that a modified version cannot function properly". In this presentation we will go through the reasons of why the information installation requirement was introduced, how you can comply with this requirement and why you may want to think about it now rather than later.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Water delivered by dental units during routine dental practice is densely contaminated by bacteria. The aim of this study was to determine actual isolation of the microorganisms sprayed from Dental Unit Water Lines (DUWLs) when enrichment cultures are performed and to compare frequencies with those obtained without enrichment cultures. Moreover, the antimicrobial susceptibilities of the microorganisms isolated were also studied. Water samples were collected from one hundred dental equipments in use at Dental Hospital of our University in order to evaluate the presence/absence of microorganisms and to perform their presumptive identification. Aliquots from all of the samples were inoculated in eight different media including both enrichment and selective media. Minimal inhibitory concentrations (MIC) were determined by the broth dilution method. The results herein reported demonstrate that most of the DUWLs were colonized by bacteria from human oral cavity; when enrichment procedures were applied the percentage of DUWLs with detectable human bacteria was one hundred percent. The results showed that in order to evaluate the actual risk of infections spread by DUWLs the inclusion of a step of pre-enrichment should be performed. The need for devices preventing bacterial contamination of DUWLs is a goal to be achieved in the near future that would contribute to maintain safety in dental medical assistance

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper analyses the determinants of broadband Internet access prices in a group of 15 EU countries between 2008 and 2011. Using a rich panel dataset of broadband plans, we show the positive effect of downstream speed on prices, and report that cable and fibre-to-the-home technologies are available at lower prices per Mbps than x DSL technology. Operators’marketing strategies are also analysed as we show how much prices rise when the broadband service is offered in a bundle with voice telephony and/or television, and how much they fall when download volume caps are included. The most insightful results of this study are provided by a group of metrics that represent the situation of competition and entry patterns in the broadband market. We show that consumer segmentation positively affects prices. On the other hand, broadband prices are higher in countries where entrants make greater use of bitstream access and lower when they use more intensively direct access -local loop unbundling-. However, we do not find a significant effect of inter-platform competition on prices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neurophysiology is an essential tool for clinicians dealing with patients in the intensive care unit. Because of consciousness disorders, clinical examination is frequently limited. In this setting, neurophysiological examination provides valuable information about seizure detection, treatment guidance, and neurological outcome. However, to acquire reliable signals, some technical precautions need to be known. EEG is prone to artifacts, and the intensive care unit environment is rich in artifact sources (electrical devices including mechanical ventilation, dialysis, and sedative medications, and frequent noise, etc.). This review will discuss and summarize the current technical guidelines for EEG acquisition and also some practical pitfalls specific for the intensive care unit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The World Health Organization (WHO) plans to submit the 11th revision of the International Classification of Diseases (ICD) to the World Health Assembly in 2018. The WHO is working toward a revised classification system that has an enhanced ability to capture health concepts in a manner that reflects current scientific evidence and that is compatible with contemporary information systems. In this paper, we present recommendations made to the WHO by the ICD revision's Quality and Safety Topic Advisory Group (Q&S TAG) for a new conceptual approach to capturing healthcare-related harms and injuries in ICD-coded data. The Q&S TAG has grouped causes of healthcare-related harm and injuries into four categories that relate to the source of the event: (a) medications and substances, (b) procedures, (c) devices and (d) other aspects of care. Under the proposed multiple coding approach, one of these sources of harm must be coded as part of a cluster of three codes to depict, respectively, a healthcare activity as a 'source' of harm, a 'mode or mechanism' of harm and a consequence of the event summarized by these codes (i.e. injury or harm). Use of this framework depends on the implementation of a new and potentially powerful code-clustering mechanism in ICD-11. This new framework for coding healthcare-related harm has great potential to improve the clinical detail of adverse event descriptions, and the overall quality of coded health data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AbstractObjective:To evaluate by magnetic resonance imaging changes in bone marrow of patients undergoing treatment for type I Gaucher’s disease.Materials and Methods:Descriptive, cross-sectional study of Gaucher’s disease patients submitted to 3 T magnetic resonance imaging of femurs and lumbar spine. The images were blindly reviewed and the findings were classified according to the semiquantitative bone marrow burden (BMB) scoring system.Results:All of the seven evaluated patients (three men and four women) presented signs of bone marrow infiltration. Osteonecrosis of the femoral head was found in three patients, Erlenmeyer flask deformity in five, and no patient had vertebral body collapse. The mean BMB score was 11, ranging from 9 to 14.Conclusion:Magnetic resonance imaging is currently the method of choice for assessing bone involvement in Gaucher’s disease in adults due to its high sensitivity to detect both focal and diffuse bone marrow changes, and the BMB score is a simplified method for semiquantitative analysis, without depending on advanced sequences or sophisticated hardware, allowing for the classification of the disease extent and assisting in the treatment monitoring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Intraocular pressure (IOP) is the pressure inside the eye that helps to maintain the integrity and the suitable form of the ocular globe. Precise and accurate measures of IOP are needed for the diagnosis as well as follow-up of glaucoma. In daily clinical practice, Goldmann applanation tonometer (GAT) and Non-contact tonometer (NCT) are the most common devices for measuring IOP. A close agreement between these methods has been showed, particularly in normotensive patients and a poor agreement, especially when IOP levels are above the normal range. Ophthalmologists have noticed a poor agreement between NCT and GAT, observing that by using NCT and after comparing with GAT, there is an overestimation of IOP readings, and particularly it occurs when the eyes are tearful. Previous studies investigate the effect of tears in Non-contact tonometer readings by the instillation of artificial tears, concluding in one of the studies that the variation was less than 1mmHg and not clinically significant, in contrast with another study which the increases were sadistically significant. Tear menisci are a thin strip of tear fluid located between the bulbar conjunctiva and the eyelid margins. We think that the overestimation of IOP readings using NCT could be due to the presence of a higher volume of tear in the lower tear meniscus which might cause an optical interference in the optoelectronic applanation monitoring system of this deviceObjectives: To research the influence of a certain volume of fluid in the lower tear meniscus on IOP measurements using the NCT in healthy eyes. Moreover, to investigate the agreement between IOP readings obtained by NCT and GAT in the presence and absence of this volume of fluidMethods: The study design will be transversal for diagnostic tests of repeated measures. We will study patients with no ocular pathology and IOP<21mmHg. It will consist in the measurement of IOP using NCT before and after the instillation of COLIRCUSÍ FLUOTEST, used as a volume of fluid in the lower tear meniscus, to observe if there will be differences using the paired t-test. Moreover, we will take IOP measures by GAT in order to know the agreement between these methods after and before the application of these eyedrops, using the ICC (intraclass correlation coefficient) and the Bland-Altmann method

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The presented thesis is devoted to investigation of wave processes in hybrid ferrite / ferroelectric structures. Spin wave devices based on ferrite films have such disadvantages, as huge size of the magnetic systems, low tuning velocity, considerable power inputs for parameters control that limits possible device applications. The considered layered structures allow to overcome the disadvantages mentioned and to promote the development of novel class of tunable microwave devices. The proposed theoretical analysis is intended to construct a model of hybrid electromagnetic-spin waves. Based on the theoretical analysis the experimental investigations were carried out. The experimental resonance characteristics of ferrite / ferroelectric resonator were obtained and their tunability by means of magnetic and electric field was demonstrated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Airlift reactors are pneumatically agitated reactors that have been widely used in chemical, petrochemical, and bioprocess industries, such as fermentation and wastewater treatment. Computational Fluid Dynamics (CFD) has become more popular approach for design, scale-up and performance evaluation of such reactors. In the present work numerical simulations for internal-loop airlift reactors were performed using the transient Eulerian model with CFD package, ANSYS Fluent 12.1. The turbulence in the liquid phase is described using κ- ε the model. Global hydrodynamic parameters like gas holdup, gas velocity and liquid velocity have been investigated for a range of superficial gas velocities, both with 2D and 3D simulations. Moreover, the study of geometry and scale influence on the reactor have been considered. The results suggest that both, geometry and scale have significant effects on the hydrodynamic parameters, which may have substantial effects on the reactor performance. Grid refinement and time-step size effect have been discussed. Numerical calculations with gas-liquid-solid three-phase flow system have been carried out to investigate the effect of solid loading, solid particle size and solid density on the hydrodynamic characteristics of internal loop airlift reactor with different superficial gas velocities. It was observed that averaged gas holdup is significantly decreased with increasing slurry concentration. Simulations show that the riser gas holdup decreases with increase in solid particle diameter. In addition, it was found that the averaged solid holdup increases in the riser section with the increase of solid density. These produced results reveal that CFD have excellent potential to simulate two-phase and three-phase flow system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effectiveness of water removal on press section is very important for a paper and board machine’s functioning, efficiency and economy. Today, the most effective method for wet pressing is shoe press technology. Metso has carried out a number of studies concerning anew type of water removal method for a press section, which has also been patented. These studies include rough sketches and some test runs. These issues form the basis of this thesis. The objective of this work was to gather together information for a new and enhanced waterremoval method for a press section by studying the functioning of the device andcarrying out test runs. This method is referred to here as Hydronip. The main goal was tobuild a functional test site which fulfills all the necessary requirements and has all thenecessary information gathering devices. The design process was carried out by emphasizing the safety aspects. The goal was also to gather together information about the nip structure in running conditions, the seal function, and to carry out the nip tests with paper or board wads. This thesis consists of a theory part, the design and construction of the test site, and carrying out test runs through information gathering. The theory part consists of the principals of water removal from a press section, Hydronip construction, and the requirements for the test place. The safety aspects were taken into account especially in test runs, but also in the assembly stages. The design and construction of the test site includes the selection of equipment and surroundings that are needed for managing the test runs in the best possible way at certain premises. The test site included the equipment that was already on the premises. Some equipment could be used as it was but some equipment had to be manufactured or modified from existing equipment. A functional test site with information gathering devices was accomplished as a result of thethesis. Test runs demonstrated that the Hydronip concept is, at least on a small scale,functional. Short-term tests for seal functioning showed that the seal can be lubricatedsufficiently under different kinds of nip load situations. Wad tests demonstrated that the metal belt is durable against different sizes of external particles. The seal also endured wad tests even though the pressure impacts impaired the lubrication. MTS tests showing dry content increases, combined with a rough cost calculation and the basic function of the machine in test runs, show that with some further study Hydronip could be a promising new product for water removal from a paper or board machine’s press section.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The process of cold storage chambers contributes largely to the quality and longevity of stored products. In recent years, it has been intensified the study of control strategies in order to decrease the temperature change inside the storage chamber and to reduce the electric power consumption. This study has developed a system for data acquisition and process control, in LabVIEW language, to be applied in the cooling system of a refrigerating chamber of 30m³. The use of instrumentation and the application developed fostered the development of scientific experiments, which aimed to study the dynamic behavior of the refrigeration system, compare the performance of control strategies and the heat engine, even due to the controlled temperature, or to the electricity consumption. This system tested the strategies for on-off control, PID and fuzzy. Regarding power consumption, the fuzzy controller showed the best result, saving 10% when compared with other tested strategies.