1000 resultados para Variables didácticas
Resumo:
Roche tomography is a technique used for imaging the Roche-lobe-filling secondary stars in cataclysmic variables (CVs). In order to interpret Roche tomograms correctly, one must determine whether features in the reconstruction are real, or the result of statistical or systematic errors. We explore the effects of systematic errors using reconstructions of simulated data sets, and show that systematic errors result in characteristic distortions of the final reconstructions that can be identified and corrected. In addition, we present a new method of estimating statistical errors on tomographic reconstructions using a Monte Carlo bootstrapping algorithm, and show this method to be much more reliable than Monte Carlo methods which 'jiggle' the data points in accordance with the size of their error bars.
Resumo:
Background: Psychological models of behaviour change are used to predict patients’ health behaviours but have rarely been used to explore healthcare professionals’ health-related behaviour. Aim: To explore the association between self-reported handwashing and a range of psychological variables in a sample of nurses in a large acute hospital. Results and discussion: Nurses in this study were more likely to wash their hands if they perceived it to be important and if they thought their workplace helped them in doing so. The best predictor of perceived importance was how strongly a nurse believed that poor handwashing practice contributes to spreading infection. Conclusion: In this study, psychological variables such as perception of importance, perception of workplace support, occupational stress and perception of risk were important predictors of handwashing behaviour.
Resumo:
Although many studies have looked at the perceptual-cognitive strategies used to make anticipatory judgments in sport, few have examined the informational invariants that our visual system may be attuned to. Using immersive interactive virtual reality to simulate the aerodynamics of the trajectory of a ball with and without sidespin, the present study examined the ability of expert and novice soccer players to make judgments about the ball's future arrival position. An analysis of their judgment responses showed how participants were strongly influenced by the ball's trajectory. The changes in trajectory caused by sidespin led to erroneous predictions about the ball's future arrival position. An analysis of potential informational variables that could explain these results points to the use of a first-order compound variable combining optical expansion and optical displacement.
Resumo:
Aims: We investigated whether the predictions and results of Stanishev et al. (2002, A&A, 394, 625) concerning a possible relationship between eclipse depths in PX And and its retrograde disc precession phase, could be confirmed in long term observations made by SuperWASP. In addition, two further CVs (DQ Her and V795 Her) in the same SuperWASP data set were investigated to see whether evidence of superhump periods and disc precession periods were present and what other, if any, long term periods could be detected. Methods: Long term photometry of PX And, V795 Her and DQ Her was carried out and Lomb-Scargle periodogram analysis undertaken on the resulting light curves. For the two eclipsing CVs, PX And and DQ Her, we analysed the potential variations in the depth of the eclipse with cycle number. Results: The results of our period and eclipse analysis on PX And confirm that the negative superhump period is 0.1417 ± 0.0001d. We find no evidence of positive superhumps in our data suggesting that PX And may have been in a low state during our observations. We improve on existing estimates of the disc precession period and find it to be 4.43 ± 0.05d. Our results confirm the predictions of Stanishev et al. (2002). We find that DQ Her does not appear to show a similar variation for we find no evidence of negative superhumps or of a retrograde disc precession. We also find no evidence of positive superhumps or of a prograde disc precession and we attribute the lack of positive superhumps in DQ Her to be due to the high mass ratio of this CV. We do however find evidence for a modulation of the eclipse depth over a period of 100 days which may be linked with solar-type magnetic cycles which give rise to long term photometric variations. The periodogram analysis for V795 Her detected the likely positive superhump period 0.1165d, however, neither the 0.10826d orbital period nor the prograde 1.53d disc precession period were seen. Here though we have found a variation in the periodogram power function at the positive superhump period, over a period of at least 120 days.
Resumo:
This article applies the panel stationarity test with a break proposed by Hadri and Rao (2008) to examine whether 14 macroeconomic variables of OECD countries can be best represented as random walk or stationary fluctuations around a deterministic trend. In contrast to previous studies, based essentially on visual inspection of the break type or just applying the most general break model, we use a model selection procedure based on BIC. We do this for each time series so that heterogeneous break models are allowed for in the panel. Our results suggest, overwhelmingly, that if we account for a structural break, cross-sectional dependence and choose the break models to be congruent with the data, then the null of stationarity cannot be rejected for all the 14 macroeconomic variables examined in this article. This is in sharp contrast with the results obtained by Hurlin (2004), using the same data but a different methodology.
Resumo:
The work presented in this paper takes advantage of newly developed instrumentation suitable for in process monitoring of an industrial stretch blow molding machine. The instrumentation provides blowing pressure and stretch rod force histories along with the kinematics of polymer contact with the mould wall. A Design of Experiments pattern was used to qualitatively relate machine inputs with these process parameters and the thickness distribution of stretch blow molded PET (polyethylene terephtalate) bottles. Material slippage at the mold wall and thickness distribution is also discussed in relation to machine inputs. The key process indicators defined have great potential for use in a closed loop process control system and for validation of process simulations.
Resumo:
We present Roche tomograms of the secondary star in the dwarf nova system RU Pegasi derived from blue and red arm ISIS data taken on the 4.2-m William Herschel Telescope. We have applied the entropy landscape technique to determine the system parameters and obtained component masses of M1 = 1.06 Msun, M2 = 0.96 Msun, an orbital inclination angle of i = 43 degrees, and an optimal systemic velocity of gamma = 7 km/s. These are in good agreement with previously published values. Our Roche tomograms of the secondary star show prominent irradiation of the inner Lagrangian point due to illumination by the disc and/or bright spot, which may have been enhanced as RU Peg was in outburst at the time of our observations.We find that this irradiation pattern is axi-symmetric and confined to regions of the star which have a direct view of the accretion regions. This is in contrast to previous attempts to map RU Peg which suggested that the irradiation pattern was non-symmetric and extended beyond the terminator. We also detect additional inhomogeneities in the surface distribution of stellar atomic absorption that we ascribe to the presence of a large star-spot. This spot is centred at a latitude of about 82 degrees and covers approximately 4 per cent of the total surface area of the secondary. In keeping with the high latitude spots mapped on the cataclysmic variables AE Aqr and BV Cen, the spot on RU Peg also appears slightly shifted towards the trailing hemisphere of the star. Finally, we speculate that early mapping attempts which indicated non-symmetric irradiation patterns which extended beyond the terminator of CV donors could possibly be explained by a superposition of symmetric heating and a large spot.
Resumo:
The effects of the process variables, pH of aqueous phase, rate of addition of organic, polymeric, drug-containing phase to aqueous phase, organic:aqueous phase volume ratio and aqueous phase temperature on the entrapment of propranolol hydrochloride in ethylcellulose (N4) microspheres prepared by the solvent evaporation method were examined using a factorial design. The observed range of drug entrapment was 1.43 +/- 0.02%w/w (pH 6, 25 degrees C, phase volume ratio 1:10, fast rate of addition) to 16.63 +/- 0.92%w/w (pH 9, 33 degrees C, phase volume ratio 1:10, slow rate of addition) which corresponded to mean entrapment efficiencies of 2.86 and 33.26, respectively. Increased pH, increased temperature and decreased rate of addition significantly enhanced entrapment efficiency. However, organic:aqueous phase volume ratio did not significantly affect drug entrapment. Statistical interactions were observed between pH and rate of addition, pH and temperature, and temperature and rate of addition. The observed interactions involving pH are suggested to be due to the abilities of increased temperature and slow rate of addition to sufficiently enhance the solubility of dichloromethane in the aqueous phase, which at pH 9, but not pH 6, allows partial polymer precipitation prior to drug partitioning into the aqueous phase. The interaction between temperature and rate of addition is due to the relative lack of effect of increased temperature on drug entrapment following slow rate of addition of the organic phase. In comparison to the effects of pH on drug entrapment, the contributions of the other physical factors examined were limited.
Resumo:
The effects of four process factors: pH, emulsifier (gelatin) concentration, mixing and batch, on the % w/w entrapment of propranolol hydrochloride in ethylcellulose microcapsules prepared by the solvent evaporation process were examined using a factorial design. In this design the minimum % w/w entrapments of propranolol hydrochloride were observed whenever the external aqueous phase contained 1.5% w/v gelatin at pH 6.0 (0.71-0.91% w/w) whereas maximum entrapments occurred whenever the external aqueous phase was composed of 0.5% w/v gelatin at pH 9.0,(8.9-9.1% w/w). The theoretical maximum loading was 50% w/w. Statistical evaluation of the results by analysis of variance showed that emulsifer (gelatin) concentration and pH, but not mixing and batch significantly affected entrapment. An interaction between pH and gelatin concentration was observed in the factorial design which was accredited to the greater effect of gelatin concentration on % w/w entrapment at pH 9.0 than at pH 6.0. Maximum theoretical entrapment was achieved by increasing the pH of the external phase to 12.0. Marked increases in drug entrapment were observed whenever the pH of the external phase exceeded the pK(2) of propranolol hydrochloride. It was concluded that pH, and hence ionisation, was the greatest determinant of entrapment of propranolol hydrochloride into microcapsules prepared by the solvent evaporation process.