872 resultados para Validation of test results
Resumo:
Background: It has been previously shown with English speaking children that food allergy clearly affects their quality of life. The first allergy quality of life questionnaire has been validated in English in 2008, however to date no questionnaire was available in French. Objectives: To validate the French version of the Food Allergy Quality of Life Questionnaire- Parent Form (FAQLQ-PF) already existing version developed and validated in English by DunnGalvin et al. Methods: The questionnaire was translated from English to French by two independent French-speaking translators and retranslated by an independent English-speaking translator. We then recruited 30 patients between 0 and 12 years with a food allergy. Parents of these children answered the questionnaire during a clinic visit. The results obtained were then analysed and compared with the results provided by DunnGalvin's study and the Food Allergy independent Measure (FAIM). Results: 27 questionnaires were fully completed and available for analysis. Median age was 6 years with a range from 18 months to 12 years. We had a girl/boy ratio of 1:1.14. A Cronbach's a correlation index of 0.748 was found. Validity was demonstrated by significant correlations between FAQLQ-PF and the FAIM. Conclusion: The French version of the FAQLQ was validated and will permit to assess degree of Quality of Life for French-speaking children with food allergy. It will be an important tool for clinical research and will allow research collaboration between French and English speaking research teams.
Resumo:
The study was designed to investigate the psychometric properties of the French version and the cross-language replicability of the Hierarchical Personality Inventory for Children (HiPIC). The HiPIC is an instrument aimed at assessing the five dimensions of the Five-Factor Model for Children. Subjects were 552 children aged between 8 and 12 years, rated by one or both parents. At the domain level, reliability ranged from .83 to .93 and at the facet level, reliability ranged from .69 to .89. Differences between genders were congruent with those found in the Dutch sample. Girls scored higher on Benevolence and Conscientiousness. Age was negatively correlated with Extraversion and Imagination. For girls, we also observed a decrease of Emotional Stability. A series of exploratory factor analyses confirmed the overall five-factor structure for girls and boys. Targeted factor analyses and congruence coefficients revealed high cross-language replicability at the domain and at the facet levels. The results showed that the French version of the HiPIC is a reliable and valid instrument for assessing personality with children and has a particularly high cross-language replicability.
Resumo:
BACKGROUND: Hepcidin, a 25 amino acid peptide, plays an important role in iron homeostasis. Some hepcidin truncated peptides have antibiotic effects. RESULTS: A new analytical method for hepcidin determination in human plasma using LC-HRMS operating in full-scan acquisition mode has been validated. The extraction consists of protein precipitation and a drying reconstitution step; a 2.1 x 50 mm (idxL) C18 analytical column was used. Detection specificity, stability, accuracy, precision and recoveries were determined. The LOQ/LOD were 0.25/0.1 nM, respectively. More than 600 injections of plasma extracts were performed, allowing evaluation of the assay robustness. Hepcidin-20, hepcidin-22 and a new isoform, hepcidin-24, were detected in patients. CONCLUSION: The data underscore the usefulness of LC-HRMS for in-depth investigations related to hepcidin levels and pathways.
Resumo:
Lymphocytic choriomeningitis virus (LCMV) is a rare cause of central nervous system disease in humans. Screening by real-time RT-PCR assay is of interest in the case of aseptic meningitis of unknown etiology. A specific LCMV real-time RT-PCR assay, based on the detection of genomic sequences of the viral nucleoprotein (NP), was developed to assess the presence of LCMV in cerebrospinal fluids (CSF) sent for viral screening to a Swiss university hospital laboratory. A 10-fold dilution series assay using a plasmid containing the cDNA of the viral NP of the LCMV isolate Armstrong (Arm) 53b demonstrated the high sensitivity of the assay with a lowest detection limit of ≤50 copies per reaction. High sensitivity was confirmed by dilution series assays in a pool of human CSF using four different LCMV isolates (Arm53b, WE54, Traub and E350) with observed detection limits of ≤10PFU/ml (Arm53b and WE54) and 1PFU/ml (Traub and E350). Analysis of 130 CSF showed no cases of acute infection. The absence of positive cases was confirmed by a published PCR assay detecting all Old World arenaviruses. This study validates a specific and sensitive real-time RT-PCR assay for the diagnosis of LCMV infections. Results showed that LCMV infections are extremely rare in hospitalized patients western in Switzerland.
Resumo:
BACKGROUND: The Multiple Sclerosis International Quality Of Life (MusiQoL) questionnaire, a 31-item, multidimensional, self-administrated questionnaire that is available in 14 languages including Spanish, has been validated using a large international sample. We investigated the validity and reliability of the Spanish version of MusiQoL in Spain. METHODS: Consecutive patients with different types and severities of multiple sclerosis (MS) were recruited from 22 centres across Spain. All patients completed the MusiQoL questionnaire, the 36-Item Short Form (SF-36) health survey, and a symptoms checklist at baseline and 21 days later. External validity, internal consistency, reliability and reproducibility were tested. RESULTS: A total of 224 Spanish patients were evaluated. Dimensions of MusiQoL generally demonstrated a high internal consistency (Cronbach's alpha: 0.70-0.92 for all but two MusiQoL domain scores). External validity testing revealed that the MusiQoL index score correlated significantly with all SF-36 dimension scores (Pearson's correlation: 0.46-0.76), reproducibility was satisfactory (intraclass correlation coefficient: 0.60-0.91), acceptability was high, and the time taken to complete the 31-item questionnaire was reasonable (mean [standard deviation]: 9.8 [11.8] minutes). CONCLUSIONS: The Spanish version of the MusiQoL questionnaire appears to be a valid and reliable instrument for measuring quality of life in patients with MS in Spain and constitutes a useful instrument to measure health-related quality of life in the clinical setting.
Resumo:
The aim of our study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable for the routine determination of blood CO concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature for CO measurement is the absence of a specific CO internal standard necessary for performing quantification. Even if stable isotope of CO is commercially available in the gaseous state, it is essential to develop a safer method to limit the manipulation of gaseous CO and to precisely control the injected amount of CO for spiking and calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in a vial in situ, an internal labeled standard gas ((13)CO) formed by the reaction of labeled formic acid formic acid (H(13)COOH) with sulfuric acid. As sulfuric acid can also be employed to liberate the CO reagent from whole blood, the procedure allows for the liberation of CO simultaneously with the generation of (13)CO. This method allows for precise measurement of blood CO concentrations from a small amount of blood (10 μL). Finally, this method was applied to measure the CO concentration of intoxicated human blood samples from autopsies.
Resumo:
The performance of the immunochromatographic assay, SD BIOLINE TB Ag MPT64 RAPID®, was evaluated in Madagascar. Using mouse anti-MPT64 monoclonal antibodies for rapid discrimination between the Mycobacterium tuberculosis complex and nontuberculous mycobacteria, the kit was tested on mycobacteria and other pathogens using conventional methods as the gold standard. The results presented here indicate that this kit has excellent sensitivity (100%) and specificity (100%) compared to standard biochemical detection and can be easily used for the rapid identification of M. tuberculosis complex.
Resumo:
RATIONALE AND OBJECTIVE:. The information assessment method (IAM) permits health professionals to systematically document the relevance, cognitive impact, use and health outcomes of information objects delivered by or retrieved from electronic knowledge resources. The companion review paper (Part 1) critically examined the literature, and proposed a 'Push-Pull-Acquisition-Cognition-Application' evaluation framework, which is operationalized by IAM. The purpose of the present paper (Part 2) is to examine the content validity of the IAM cognitive checklist when linked to email alerts. METHODS: A qualitative component of a mixed methods study was conducted with 46 doctors reading and rating research-based synopses sent on email. The unit of analysis was a doctor's explanation of a rating of one item regarding one synopsis. Interviews with participants provided 253 units that were analysed to assess concordance with item definitions. RESULTS AND CONCLUSION: The content relevance of seven items was supported. For three items, revisions were needed. Interviews suggested one new item. This study has yielded a 2008 version of IAM.
Resumo:
BACKGROUND: The Outpatient Bleeding Risk Index (OBRI) and the Kuijer, RIETE and Kearon scores are clinical prognostic scores for bleeding in patients receiving oral anticoagulants for venous thromboembolism (VTE). We prospectively compared the performance of these scores in elderly patients with VTE. METHODS: In a prospective multicenter Swiss cohort study, we studied 663 patients aged ≥ 65 years with acute VTE. The outcome was a first major bleeding at 90 days. We classified patients into three categories of bleeding risk (low, intermediate and high) according to each score and dichotomized patients as high vs. low or intermediate risk. We calculated the area under the receiver-operating characteristic (ROC) curve, positive predictive values and likelihood ratios for each score. RESULTS: Overall, 28 out of 663 patients (4.2%, 95% confidence interval [CI] 2.8-6.0%) had a first major bleeding within 90 days. According to different scores, the rate of major bleeding varied from 1.9% to 2.1% in low-risk, from 4.2% to 5.0% in intermediate-risk and from 3.1% to 6.6% in high-risk patients. The discriminative power of the scores was poor to moderate, with areas under the ROC curve ranging from 0.49 to 0.60 (P = 0.21). The positive predictive values and positive likelihood ratios were low and varied from 3.1% to 6.6% and from 0.72 to 1.59, respectively. CONCLUSION: In elderly patients with VTE, existing bleeding risk scores do not have sufficient accuracy and power to discriminate between patients with VTE who are at a high risk of short-term major bleeding and those who are not.
Resumo:
BACKGROUND Identifying individuals at high risk of excess weight gain may help targeting prevention efforts at those at risk of various metabolic diseases associated with weight gain. Our aim was to develop a risk score to identify these individuals and validate it in an external population. METHODS We used lifestyle and nutritional data from 53°758 individuals followed for a median of 5.4 years from six centers of the European Prospective Investigation into Cancer and Nutrition (EPIC) to develop a risk score to predict substantial weight gain (SWG) for the next 5 years (derivation sample). Assuming linear weight gain, SWG was defined as gaining ≥ 10% of baseline weight during follow-up. Proportional hazards models were used to identify significant predictors of SWG separately by EPIC center. Regression coefficients of predictors were pooled using random-effects meta-analysis. Pooled coefficients were used to assign weights to each predictor. The risk score was calculated as a linear combination of the predictors. External validity of the score was evaluated in nine other centers of the EPIC study (validation sample). RESULTS Our final model included age, sex, baseline weight, level of education, baseline smoking, sports activity, alcohol use, and intake of six food groups. The model's discriminatory ability measured by the area under a receiver operating characteristic curve was 0.64 (95% CI = 0.63-0.65) in the derivation sample and 0.57 (95% CI = 0.56-0.58) in the validation sample, with variation between centers. Positive and negative predictive values for the optimal cut-off value of ≥ 200 points were 9% and 96%, respectively. CONCLUSION The present risk score confidently excluded a large proportion of individuals from being at any appreciable risk to develop SWG within the next 5 years. Future studies, however, may attempt to further refine the positive prediction of the score.
Resumo:
BACKGROUND/OBJECTIVES: (1) To cross-validate tetra- (4-BIA) and octopolar (8-BIA) bioelectrical impedance analysis vs dual-energy X-ray absorptiometry (DXA) for the assessment of total and appendicular body composition and (2) to evaluate the accuracy of external 4-BIA algorithms for the prediction of total body composition, in a representative sample of Swiss children. SUBJECTS/METHODS: A representative sample of 333 Swiss children aged 6-13 years from the Kinder-Sportstudie (KISS) (ISRCTN15360785). Whole-body fat-free mass (FFM) and appendicular lean tissue mass were measured with DXA. Body resistance (R) was measured at 50 kHz with 4-BIA and segmental body resistance at 5, 50, 250 and 500 kHz with 8-BIA. The resistance index (RI) was calculated as height(2)/R. Selection of predictors (gender, age, weight, RI4 and RI8) for BIA algorithms was performed using bootstrapped stepwise linear regression on 1000 samples. We calculated 95% confidence intervals (CI) of regression coefficients and measures of model fit using bootstrap analysis. Limits of agreement were used as measures of interchangeability of BIA with DXA. RESULTS: 8-BIA was more accurate than 4-BIA for the assessment of FFM (root mean square error (RMSE)=0.90 (95% CI 0.82-0.98) vs 1.12 kg (1.01-1.24); limits of agreement 1.80 to -1.80 kg vs 2.24 to -2.24 kg). 8-BIA also gave accurate estimates of appendicular body composition, with RMSE < or = 0.10 kg for arms and < or = 0.24 kg for legs. All external 4-BIA algorithms performed poorly with substantial negative proportional bias (r> or = 0.48, P<0.001). CONCLUSIONS: In a representative sample of young Swiss children (1) 8-BIA was superior to 4-BIA for the prediction of FFM, (2) external 4-BIA algorithms gave biased predictions of FFM and (3) 8-BIA was an accurate predictor of segmental body composition.
Resumo:
BACKGROUND The purpose of the present study is to translate and validate the "Hip and Knee Outcomes Questionnaire", developed in English, into Spanish. The 'Hip and Knee Outcomes Questionnaire is a questionnaire planned to evaluate the impact in quality of life of any problem related to the human musculoskeletal system. 10 scientific associations developed it. METHODS The questionnaire underwent a validated translation/retro-translation process. Patients undergoing primary knee arthroplasty, before and six months postoperative, tested the final version in Spanish. Psychometric properties of feasibility, reliability, validity and sensitivity to change were assessed. Convergent validity with SF-36 and WOMAC questionnaires was evaluated. RESULTS 316 patients were included. Feasibility: a high number of missing items in questions 3, 4 and 5 were observed. The number of patients with a missing item was 171 (51.35%) in the preoperative visit and 139 (44.0%) at the postoperative. Internal validity: revision of coefficients in the item-rest correlation recommended removing question 6 during the preoperative visit (coefficient <0.20). Convergent validity: coefficients of correlation with WOMAC and SF-36 scales confirm the questionnaire's validity. Sensitivity to change: statistically significant differences were found between the mean scores of the first visit compared to the postoperative. CONCLUSION The proposed translation to Spanish of the 'Hip and Knee Questionnaire' is found to be reliable, valid and sensible to changes produced at the clinical practice of patients undergoing primary knee arthroplasty. However, some changes at the completion instructions are recommended. LEVEL OF EVIDENCE Level I. Prognostic study.
Resumo:
Most ventricular assist devices (VADs) currently used in infants are extracorporeal. These VADs require long-term anticoagulation therapy and extensive surgery, and two devices are needed for biventricular support. We designed a biventricular assist device based on shape memory alloy that reproduces the hemodynamic effects of cardiomyoplasty, supporting the heart with a compressing movement, and evaluated its performance in a dedicated mockup system. Nitinol fibers are the device's key component. Ejection fraction (EF), cardiac output (CO), and generated systolic pressure were measured on a test bench. Our test bench settings were a preload range of 0-15 mm Hg, an afterload range of 0-160 mm Hg, and a heart rate (HR) of 20, 30, 40, and 60 beats/min. A power supply of 15 volts and 3.5 amperes was necessary. The EF range went from 34.4% to 1.2% as the afterload and HR increased, along with a CO from 180 to 6 ml/min. The device generated a maximal systolic pressure of 25 mm Hg. Cardiac compression for biventricular assistance in child-sized heart using shape memory alloy is technically feasible. Further testing remains necessary to assess this VAD's in vivo performance range and its reliability.
Resumo:
Study design:Cross-sectional validation study.Objectives:To develop and validate a self-report version of the Spinal Cord Independence Measure (SCIM III).Setting:Two SCI rehabilitation facilities in Switzerland.Methods:SCIM III comprises 19 questions on daily tasks with a total score between 0 and 100 and subscales for 'self-care', 'respiration & sphincter management' and 'mobility'. A self-report version (SCIM-SR) was developed by expert discussions and pretests in individuals with spinal cord injury (SCI) using a German translation. A convenience sample of 99 inpatients with SCI was recruited. SCIM-SR data were analyzed together with SCIM III data obtained from attending health professionals.Results:High correlations between SCIM III and SCIM-SR were observed. Pearson's r for the total score was 0.87 (95% confidence interval (CI) 0.82-0.91), for the subscales self-care 0.87 (0.81-0.91); respiration & sphincter management 0.81 (0.73-0.87); and mobility 0.87 (0.82-0.91). Intraclass correlations were: total score 0.90 (95% CI 0.85-0.93); self-care 0.86 (0.79-0.90); respiration & sphincter management 0.80 (0.71-0.86); and mobility 0.83 (0.76-0.89). Bland-Altman plots showed that patients rated their functioning higher than professionals, in particular for mobility. The mean difference between SCIM-SR and SCIM III for the total score was 5.14 (point estimate 95% CI 2.95-7.34), self-care 0.89 (0.19-1.59), respiration & sphincter management 1.05 (0.18-2.28 ) and mobility 3.49 (2.44-4.54). Particularly patients readmitted because of pressure sores rated their independence higher than attending professionals.Conclusion:Our results support the criterion validity of SCIM-SR. The self-report version may facilitate long-term evaluations of independence in persons with SCI in their home situation.
Resumo:
PURPOSE: Cardiovascular magnetic resonance (CMR) has become a robust and important diagnostic imaging modality in cardiovascular medicine. However,insufficient image quality may compromise its diagnostic accuracy. No standardized criteria are available to assess the quality of CMR studies. We aimed todescribe and validate standardized criteria to evaluate the quality of CMR studies including: a) cine steady-state free precession, b) delayed gadoliniumenhancement, and c) adenosine stress first-pass perfusion. These criteria will serve for the assessment of the image quality in the setting of the Euro-CMR registry.METHOD AND MATERIALS: First, a total of 45 quality criteria were defined (35 qualitative criteria with a score from 0-3, and 10 quantitative criteria). Thequalitative score ranged from 0 to 105. The lower the qualitative score, the better the quality. The quantitative criteria were based on the absolute signal intensity (delayed enhancement) and on the signal increase (perfusion) of the anterior/posterior left ventricular wall after gadolinium injection. These criteria were then applied in 30 patients scanned with a 1.5T system and in 15 patients scanned with a 3.0T system. The examinations were jointly interpreted by 3 CMR experts and 1 study nurse. In these 45 patients the correlation between the results of the quality assessment obtained by the different readers was calculated.RESULTS: On the 1.5T machine, the mean quality score was 3.5. The mean difference between each pair of observers was 0.2 (5.7%) with a mean standarddeviation of 1.4. On the 3.0T machine, the mean quality score was 4.4. The mean difference between each pair of onservers was 0.3 (6.4%) with a meanstandard deviation of 1.6. The quantitative quality assessments between observers were well correlated for the 1.5T machine: R was between 0.78 and 0.99 (pCONCLUSION: The described criteria for the assessment of CMR image quality are robust and have a low inter-observer variability, especially on 1.5T systems.CLINICAL RELEVANCE/APPLICATION: These criteria will allow the standardization of CMR examinations. They will help to improve the overall quality ofexaminations and the comparison between clinical studies.