886 resultados para Technology Assessment
Resumo:
S/N 052-003-00859-9
Resumo:
Mode of access: Internet.
Resumo:
Item 1070-M
Resumo:
"OTA-TM-STI-19"--P. [4] of cover.
Resumo:
"OTA-ISC-240"--P. [36]
Resumo:
Item 1070-M.
Resumo:
Item 1070-M
Resumo:
"OTA-E-246"--P. [4] of cover
Resumo:
Mode of access: Internet.
Resumo:
Background The 2001 Australian census revealed that adults aged 65 years and over constituted 12.6% of the population, up from 12.1% in 1996. It is projected that this figure will rise to 21% or 5.1 million Australians by 2031. In 1998, 6% (134 000) of adults in Australia aged 65 years and over were residing in nursing homes or hostels and this number is also expected to rise. As skin ages, there is a decreased turnover and replacement of epidermal skin cells, a thinning subcutaneous fat layer and a reduced production of protective oils. These changes can affect the normal functions of the skin such as its role as a barrier to irritants and pathogens, temperature and water regulation. Generally, placement in a long-term care facility indicates an inability of the older person to perform all of the activities of daily living such as skin care. Therefore, skin care management protocols should be available to reduce the likelihood of skin irritation and breakdown and ultimately promote comfort of the older person. Objectives The objective of this review was to determine the best available evidence for the effectiveness and safety of topical skin care regimens for older adults residing in long-term aged care facilities. The primary outcome was the incidence of adverse skin conditions with patient satisfaction considered as a secondary outcome. Search strategy A literature search was performed using the following databases: PubMed (NLM) (1966–4/2003), Embase (1966–4/2003), CINAHL (1966–4/2003), Current Contents (1993–4/2003), Cochrane Library (1966–2/2003), Web of Science (1995–12/2002), Science Citation Index Expanded and ProceedingsFirst (1993–12/2002). Health Technology Assessment websites were also searched. No language restrictions were applied. Selection criteria Systematic reviews of randomised controlled trials, randomised and non-randomised controlled trials evaluating any non-medical intervention or program that aimed to maintain or improve the integrity of skin in older adults were considered for inclusion. Participants were 65 years of age or over and residing in an aged care facility, hospital or long-term care in the community. Studies were excluded if they evaluated pressure-relieving techniques for the prevention of skin breakdown. Data collection and analysis Two independent reviewers assessed study eligibility for inclusion. Study design and quality were tabulated and relative risks, odds ratios, mean differences and associated 95% confidence intervals were calculated from individual comparative studies containing count data. Results The resulting evidence of the effectiveness of topical skin care interventions was variable and dependent upon the skin condition outcome being assessed. The strongest evidence for maintenance of skin condition in incontinent patients found that disposable bodyworn incontinence protection reduced the odds of deterioration of skin condition compared with non-disposable bodyworns. The best evidence for non-pressure relieving topical skin care interventions on pressure sore formation found the no-rinse cleanser Clinisan to be more effective than soap and water at maintaining healthy skin (no ulcers) in elderly incontinent patients in long-term care. The quality of studies examining the effectiveness of topical skin care interventions on the incidence of skin tears was very poor and inconclusive. Topical skin care for prevention of dermatitis found that Sudocrem could reduce the redness of skin compared with zinc cream if applied regularly after each pad change, but not the number of lesions. Topical skin care on dry skin found the Bag Bath/Travel Bath no-rinse skin care cleanser to be more effective at preventing overall skin dryness and most specifically flaking and scaling when compared with the traditional soap and water washing method in residents of a long-term care facility. Information on the safety of topical skin care interventions is lacking. Therefore, because of the lack of evidence, no recommendation on the safety on any intervention included in this review can be made.
Resumo:
Background: Fetal pulse oximetry (FPO) may improve the assessment of the fetal well-being in labour. Reports of health-care provider's evaluations of new technology are important in the overall evaluation of that technology. Aims: To determine doctors' and midwives' perceptions of their experience placing FPO sensors. Methods: We surveyed clinicians (midwives and doctors) following placement of a FPO sensor during the FOREMOST trial (multicentre randomised trial of fetal pulse oximetry). Clinicians rated ease of sensor placement (poor, fair, good and excellent). Potential influences on ease of sensor placement (staff category, prior experience in Birth Suite, prior experience in placing sensors, epidural analgesia, cervical dilatation and fetal station) were examined by ordinal regression. Results: There were 281 surveys returned for the 294 sensor placement attempts (response rate 96%). Sensors were placed by midwives (29%), research midwives (48%), registrars (22%) and obstetricians (1%). The majority of clinicians had 1 or more years' Birth Suite experience, had placed six or more sensors previously, and rated ease of sensor placement as good. Advancing fetal station (P < 0.001) and the presence of epidural analgesia prior to sensor placement (P = 0.029) predicted improved ease of sensor placement. Having a clinician placing a sensor for the first time predicted a lower rating for ease of sensor placement (P = 0.001), compared to having placed one or more sensors previously. Conclusions: Clinicians with varying levels of Birth Suite experience successfully placed fetal oxygen saturation sensors, with the majority rating ease of sensor placement as good.
Resumo:
This systematic review aimed to evaluate the best available evidence regarding the effectiveness of topical skin care interventions for residents of aged care facilities. Introduction. Natural changes to skin, as well as increased predisposition to pressure sores and incontinence, means residents of aged care facilities readily require topical skin care. A range of interventions exist that aim to maintain or improve the integrity of skin of older adults. Methods. Pubmed, Embase, Current Contents, CINAHL and The Cochrane Library databases were searched, as well as Health Technology Assessment websites up to April 2003. Systematic reviews and randomized or non-randomized controlled trials were evaluated for quality and data were independently extracted by two reviewers. Results. The effectiveness of topical skin interventions was variable and dependent on the skin condition being treated. Studies examined the effectiveness of washing products on incontinence irritated skin. Disposable bodyworns may prevent deterioration of skin condition better than non-disposable underpads or bodyworns. Clinisan, a no-rinse cleanser may reduce the incidence of incontinence associated pressure ulcers when compared with soap and water. Conclusion. In general the quality of evidence for interventions to improve or maintain the skin condition in the older person was poor and more research in this area is needed. Relevance to Clinical Practice. Skin care is a major issue for nurses working with older people. On the basis of this review no clear recommendations can be made. This lack of strong evidence for nurses to base effective practice decisions is problematic. However, the 'best' evidence suggests that disposable bodyworns are a good investment in the fight against skin deterioration. No rinse cleansers are to be preferred over soap and the use of the bag bath appears to be a useful practice to reduce the risk of dry skin ( a risk factor for breaches in skin integrity).
Resumo:
OBJECTIVE: To determine the accuracy, acceptability and cost-effectiveness of polymerase chain reaction (PCR) and optical immunoassay (OIA) rapid tests for maternal group B streptococcal (GBS) colonisation at labour. DESIGN: A test accuracy study was used to determine the accuracy of rapid tests for GBS colonisation of women in labour. Acceptability of testing to participants was evaluated through a questionnaire administered after delivery, and acceptability to staff through focus groups. A decision-analytic model was constructed to assess the cost-effectiveness of various screening strategies. SETTING: Two large obstetric units in the UK. PARTICIPANTS: Women booked for delivery at the participating units other than those electing for a Caesarean delivery. INTERVENTIONS: Vaginal and rectal swabs were obtained at the onset of labour and the results of vaginal and rectal PCR and OIA (index) tests were compared with the reference standard of enriched culture of combined vaginal and rectal swabs. MAIN OUTCOME MEASURES: The accuracy of the index tests, the relative accuracies of tests on vaginal and rectal swabs and whether test accuracy varied according to the presence or absence of maternal risk factors. RESULTS: PCR was significantly more accurate than OIA for the detection of maternal GBS colonisation. Combined vaginal or rectal swab index tests were more sensitive than either test considered individually [combined swab sensitivity for PCR 84% (95% CI 79-88%); vaginal swab 58% (52-64%); rectal swab 71% (66-76%)]. The highest sensitivity for PCR came at the cost of lower specificity [combined specificity 87% (95% CI 85-89%); vaginal swab 92% (90-94%); rectal swab 92% (90-93%)]. The sensitivity and specificity of rapid tests varied according to the presence or absence of maternal risk factors, but not consistently. PCR results were determinants of neonatal GBS colonisation, but maternal risk factors were not. Overall levels of acceptability for rapid testing amongst participants were high. Vaginal swabs were more acceptable than rectal swabs. South Asian women were least likely to have participated in the study and were less happy with the sampling procedure and with the prospect of rapid testing as part of routine care. Midwives were generally positive towards rapid testing but had concerns that it might lead to overtreatment and unnecessary interference in births. Modelling analysis revealed that the most cost-effective strategy was to provide routine intravenous antibiotic prophylaxis (IAP) to all women without screening. Removing this strategy, which is unlikely to be acceptable to most women and midwives, resulted in screening, based on a culture test at 35-37 weeks' gestation, with the provision of antibiotics to all women who screened positive being most cost-effective, assuming that all women in premature labour would receive IAP. The results were sensitive to very small increases in costs and changes in other assumptions. Screening using a rapid test was not cost-effective based on its current sensitivity, specificity and cost. CONCLUSIONS: Neither rapid test was sufficiently accurate to recommend it for routine use in clinical practice. IAP directed by screening with enriched culture at 35-37 weeks' gestation is likely to be the most acceptable cost-effective strategy, although it is premature to suggest the implementation of this strategy at present.
Resumo:
Background - Menorrhagia is a common problem, yet evidence to inform decisions about therapy is limited. In a pragmatic, multicenter, randomized trial, we compared the levonorgestrel-releasing intrauterine system (levonorgestrel-IUS) with usual medical treatment in women with menorrhagia who presented to their primary care providers. Methods - We randomly assigned 571 women with menorrhagia to treatment with levonorgestrel-IUS or usual medical treatment (tranexamic acid, mefenamic acid, combined estrogen–progestogen, or progesterone alone). The primary outcome was the patient-reported score on the Menorrhagia Multi-Attribute Scale (MMAS) (ranging from 0 to 100, with lower scores indicating greater severity), assessed over a 2-year period. Secondary outcomes included general quality-of-life and sexual-activity scores and surgical intervention. Results - MMAS scores improved from baseline to 6 months in both the levonorgestrel-IUS group and the usual-treatment group (mean increase, 32.7 and 21.4 points, respectively; P<0.001 for both comparisons). The improvements were maintained over a 2-year period but were significantly greater in the levonorgestrel-IUS group than in the usual-treatment group (mean between-group difference, 13.4 points; 95% confidence interval, 9.9 to 16.9; P<0.001). Improvements in all MMAS domains (practical difficulties, social life, family life, work and daily routine, psychological well-being, and physical health) were significantly greater in the levonorgestrel-IUS group than in the usual-treatment group, and this was also true for seven of the eight quality-of-life domains. At 2 years, more of the women were still using the levonorgestrel-IUS than were undergoing the usual medical treatment (64% vs. 38%, P<0.001). There were no significant between-group differences in the rates of surgical intervention or sexual-activity scores. There were no significant differences in serious adverse events between groups. Conclusions - In women with menorrhagia who presented to primary care providers, the levonorgestrel-IUS was more effective than usual medical treatment in reducing the effect of heavy menstrual bleeding on quality of life. (Funded by the National Institute of Health Research Health Technology Assessment Programme; ECLIPSE Controlled-Trials.com number, ISRCTN86566246.)
Resumo:
Background: Screening for congenital heart defects (CHDs) relies on antenatal ultrasound and postnatal clinical examination; however, life-threatening defects often go undetected. Objective: To determine the accuracy, acceptability and cost-effectiveness of pulse oximetry as a screening test for CHDs in newborn infants. Design: A test accuracy study determined the accuracy of pulse oximetry. Acceptability of testing to parents was evaluated through a questionnaire, and to staff through focus groups. A decision-analytic model was constructed to assess cost-effectiveness. Setting: Six UK maternity units. Participants: These were 20,055 asymptomatic newborns at = 35 weeks’ gestation, their mothers and health-care staff. Interventions: Pulse oximetry was performed prior to discharge from hospital and the results of this index test were compared with a composite reference standard (echocardiography, clinical follow-up and follow-up through interrogation of clinical databases). Main outcome measures: Detection of major CHDs – defined as causing death or requiring invasive intervention up to 12 months of age (subdivided into critical CHDs causing death or intervention before 28 days, and serious CHDs causing death or intervention between 1 and 12 months of age); acceptability of testing to parents and staff; and the cost-effectiveness in terms of cost per timely diagnosis. Results: Fifty-three of the 20,055 babies screened had a major CHD (24 critical and 29 serious), a prevalence of 2.6 per 1000 live births. Pulse oximetry had a sensitivity of 75.0% [95% confidence interval (CI) 53.3% to 90.2%] for critical cases and 49.1% (95% CI 35.1% to 63.2%) for all major CHDs. When 23 cases were excluded, in which a CHD was already suspected following antenatal ultrasound, pulse oximetry had a sensitivity of 58.3% (95% CI 27.7% to 84.8%) for critical cases (12 babies) and 28.6% (95% CI 14.6% to 46.3%) for all major CHDs (35 babies). False-positive (FP) results occurred in 1 in 119 babies (0.84%) without major CHDs (specificity 99.2%, 95% CI 99.0% to 99.3%). However, of the 169 FPs, there were six cases of significant but not major CHDs and 40 cases of respiratory or infective illness requiring medical intervention. The prevalence of major CHDs in babies with normal pulse oximetry was 1.4 (95% CI 0.9 to 2.0) per 1000 live births, as 27 babies with major CHDs (6 critical and 21 serious) were missed. Parent and staff participants were predominantly satisfied with screening, perceiving it as an important test to detect ill babies. There was no evidence that mothers given FP results were more anxious after participating than those given true-negative results, although they were less satisfied with the test. White British/Irish mothers were more likely to participate in the study, and were less anxious and more satisfied than those of other ethnicities. The incremental cost-effectiveness ratio of pulse oximetry plus clinical examination compared with examination alone is approximately £24,900 per timely diagnosis in a population in which antenatal screening for CHDs already exists. Conclusions: Pulse oximetry is a simple, safe, feasible test that is acceptable to parents and staff and adds value to existing screening. It is likely to identify cases of critical CHDs that would otherwise go undetected. It is also likely to be cost-effective given current acceptable thresholds. The detection of other pathologies, such as significant CHDs and respiratory and infective illnesses, is an additional advantage. Other pulse oximetry techniques, such as perfusion index, may enhance detection of aortic obstructive lesions.