991 resultados para Tag ownership transfer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transfer schemes are an alternative means of acquiring control of a company to making a takeover bid under the provisions in Ch 6 of the Corporations Act 2001 (Cth). The recent decision Re Kumarina Resources Ltd [2013] FCA 549 overturned long-standing practice in relation to a certain type of transfer scheme. If followed, the decision would allow a “bidder” to vote at scheme meetings where the scheme consideration for the acquisition of the target shares are shares in another company, and the scheme results in a merger. But the bidder is not allowed to vote where the scheme consideration is cash. The article points out the difficulties arising from this decision and argues that it should not be followed. In providing a “no objection” statement, the Australian Securities and Investments Commission (ASIC) has created uncertainty as to the approach it will take towards the bidders being allowed to vote at scheme meetings where the scheme consideration for the acquisition of target shares are shares in another company. The article also points out that in providing the no objection statement in Kumarina, ASIC appears to have ignored breaches of s 606(1) of the Corporations Act. There is a pressing need for ASIC to clarify its position and, in particular, whether or not it will provide a no objection statement in respect of future transfer schemes where a bidder (or its parent company) votes at the scheme meeting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research studies aimed at advancing cancer prevention, diagnosis, and treatment depend on a number of key resources, including a ready supply of high-quality annotated biospecimens from diverse ethnic populations that can be used to test new drugs, assess the validity of prognostic biomarkers, and develop tailor-made therapies. In November 2011, KHCCBIO was established at the King Hussein Cancer Center (KHCC) with the support of Seventh Framework Programme (FP7) funding from the European Union (khccbio.khcc.jo). KHCCBIO was developed for the purpose of achieving an ISO accredited cancer biobank through the collection, processing, and preservation of high-quality, clinically annotated biospecimens from consenting cancer patients, making it the first cancer biobank of its kind in Jordan. The establishment of a state-of-the-art, standardized biospecimen repository of matched normal and lung tumor tissue, in addition to blood components such as serum, plasma, and white blood cells, was achieved through the support and experience of its European partners, Trinity College Dublin, Biostor Ireland, and accelopment AG. To date, KHCCBIO along with its partners, have worked closely in establishing an ISO Quality Management System (QMS) under which the biobank will operate. A Quality Policy Manual, Validation, and Training plan have been developed in addition to the development of standard operating procedures (SOPs) for consenting policies on ethical issues, data privacy, confidentiality, and biobanking bylaws. SOPs have also been drafted according to best international practices and implemented for the donation, procurement, processing, testing, preservation, storage, and distribution of tissues and blood samples from lung cancer patients, which will form the basis for the procurement of other cancer types. KHCCBIO will be the first ISO accredited cancer biobank from a diverse ethnic Middle Eastern and North African population. It will provide a unique and valuable resource of high-quality human biospecimens and anonymized clinicopathological data to the cancer research communities world-wide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrochemical aptamer-based (E-AB) sensors represent an emerging class of recently developed sensors. However, numerous of these sensors are limited by a low surface density of electrode-bound redox-oligonucleotides which are used as probe. Here we propose to use the concept of electrochemical current rectification (ECR) for the enhancement of the redox signal of E-AB sensors. Commonly, the probe-DNA performs a change in conformation during target binding and enables a nonrecurring charge transfer between redox-tag and electrode. In our system, the redox-tag of the probe-DNA is continuously replenished by solution-phase redox molecules. A unidirectional electron transfer from electrode via surface-linked redox-tag to the solution-phase redox molecules arises that efficiently amplifies the current response. Using this robust and straight-forward strategy, the developed sensor showed a substantial signal amplification and consequently improved sensitivity with a calculated detection limit of 114 nM for ATP, which was improved by one order of magnitude compared with the amplification-free detection and superior to other previous detection results using enzymes or nanomaterials-based signal amplification. To the best of our knowledge, this is the first demonstration of an aptamer-based electrochemical biosensor involving electrochemical rectification, which can be presumably transferred to other biomedical sensor systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper is to obtain the momentum transfer coefficient between the two phases, denoted by f and p, occupying a bi-disperse porous medium by mapping the available experimental data to the theoretical model proposed by Nield and Kuznetsov. Data pertinent to plate-fin heat exchangers, as bi-disperse porous media, were used. The measured pressure drops for such heat exchangers are then used to give the overall permeability which is linked to the porosity and permeability of each phase as well as the interfacial momentum transfer coefficient between the two phases. Accordingly, numerical values are obtained for the momentum transfer coefficient for three different fin spacing values considered in the heat exchanger experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modelling of food processing is complex because it involves sophisticated material and transport phenomena. Most of the agricultural products such fruits and vegetables are hygroscopic porous media containing free water, bound water, gas and solid matrix. Considering all phase in modelling is still not developed. In this article, a comprehensive porous media model for drying has been developed considering bound water, free water separately, as well as water vapour and air. Free water transport was considered as diffusion, pressure driven and evaporation. Bound water assumed to be converted to free water due to concentration difference and also can diffuse. Binary diffusion between water vapour and air was considered. Since, the model is fundamental physics based it can be applied to any drying applications and other food processing where heat and mass transfer takes place in porous media with significant evaporation and other phase change.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The evaluation of retinal image quality in cataract eyes has gained importance and the clinical modulation transfer functions (MTF) can obtained by aberrometer and double pass (DP) system. This study aimed to compare MTF derived from a ray tracing aberrometer and a DP system in early cataractous and normal eyes. METHODS: There were 128 subjects with 61 control eyes and 67 eyes with early cataract defined according to the Lens Opacities Classification System III. A laser ray-tracing wavefront aberrometer (iTrace) and a double pass (DP) system (OQAS) assessed ocular MTF for 6.0 mm pupil diameters following dilation. Areas under the MTF (AUMTF) and their correlations were analyzed. Stepwise multiple regression analysis assessed factors affecting the differences between iTrace- and OQAS-derived AUMTF for the early cataract group. RESULTS: For both early cataract and control groups, iTrace-derived MTFs were higher than OQAS-derived MTFs across a range of spatial frequencies (P < 0.01). No significant difference between the two groups occurred for iTrace-derived AUMTF, but the early cataract group had significantly smaller OQAS-derived AUMTF than did the control group (P < 0.01). AUMTF determined from both the techniques demonstrated significant correlations with nuclear opacities, higher-order aberrations (HOAs), visual acuity, and contrast sensitivity functions, while the OQAS-derived AUMTF also demonstrated significant correlations with age and cortical opacity grade. The factors significantly affecting the difference between iTrace and OQAS AUMTF were root-mean-squared HOAs (standardized beta coefficient = -0.63, P < 0.01) and age (standardized beta coefficient = 0.26, P < 0.01). CONCLUSIONS: MTFs determined from a iTrace and a DP system (OQAS) differ significantly in early cataractous and normal subjects. Correlations with visual performance were higher for the DP system. OQAS-derived MTF may be useful as an indicator of visual performance in early cataract eyes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To reduce the natural convection heat loss from enclosures many researchers used convection suppression devices in the past. In this study a single baffle is used under the top tip to investigate numerically the natural convection heat loss in an attic shaped enclosure which is a cost effective approach. The case considered here is one inclined wall of the enclosure is uniformly heated while the other inclined wall is uniformly cooled with adiabatic bottom wall. The finite volume method has been used to discretize the governing equations, with the QUICK scheme approximating the advection term. The diffusion terms are discretized using central-differencing with second order accuracy. A wide range of governing parameters are studied (Rayleigh number, aspect ratio, baffle length etc.). It is observed that the heat transfer due to natural convection in the enclosure reduces when the baffle length is increased. Effects of other parameters on heat transfer and flow field are described in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports a hybrid of two metal-organic semiconductors that are based on organic charge transfer complexes of 7,7,8,8-tetracyanoquinodimethane (TCNQ). It is shown that the spontaneous reaction between semiconducting microrods of CuTCNQ with Ag+ ions leads to the formation of a CuTCNQ/AgTCNQ hybrid, both in aqueous solution and acetonitrile, albeit with completely different reaction mechanisms. In an aqueous environment, the reaction proceeds by a complex galvanic replacement (GR) mechanism, wherein in addition to AgTCNQ nanowires, Ag0 nanoparticles and Cu(OH)2 crystals decorate the surface of CuTCNQ microrods. Conversely, in acetonitrile, a GR mechanism is found to be thermodynamically unfavorable and instead a corrosion-recrystallization mechanism leads to the decoration of CuTCNQ microrods with AgTCNQ nanoplates, resulting in a pure CuTCNQ/AgTCNQ hybrid metal-organic charge transfer complex. While hybrids of two different inorganic semiconductors are regularly reported, this report pioneers the formation of a hybrid involving two metal-organic semiconductors that will expand the scope of TCNQ-based charge transfer complexes for improved catalysis, sensing, electronics and biological applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

100 year old gasoline engine technology vehicles have now become one of the major contributors of greenhouse gases. Plug-in Electric Vehicles (PEVs) have been proposed to achieve environmental friendly transportation. Even though the PEV usage is currently increasing, a technology breakthrough would be required to overcome battery related drawbacks. Although battery technology is evolving, drawbacks inherited with batteries such as; cost, size, weight, slower charging characteristic and low energy density would still be dominating constrains for development of EVs. Furthermore, PEVs have not been accepted as preferred choice by many consumers due to charging related issues. To address battery related limitations, the concept of dynamic Wireless Power Transfer (WPT) enabled EVs have been proposed in which EV is being charged while it is in motion. WPT enabled infrastructure has to be employed to achieve dynamic EV charging concept. The weight of the battery pack can be reduced as the required energy storage is lower if the vehicle can be powered wirelessly while driving. Stationary WPT charging where EV is charged wirelessly when it is stopped, is simpler than dynamic WPT in terms of design complexity. However, stationary WPT does not increase vehicle range compared to wired-PEVs. State-of-art WPT technology for future transportation is discussed in this chapter. Analysis of the WPT system and its performance indices are introduced. Modelling the WPT system using different methods such as equivalent circuit theory, two port network theory and coupled mode theory is described illustrating their own merits in Sect. 2.3. Both stationary and dynamic WPT for EV applications are illustrated in Sect. 2.4. Design challenges and optimization directions are analysed in Sect. 2.5. Adaptive tuning techniques such as adaptive impedance matching and frequency tuning are also discussed. A case study for optimizing resonator design is presented in Sect. 2.6. Achievements by the research community is introduced highlighting directions for future research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Unidirectional inductive power transfer (UIPT) systems allow loads to consume power while bidirectional IPT (BIPT) systems are more suitable for loads requiring two way power flow such as vehicle to grid (V2G) applications with electric vehicles (EVs). Many attempts have been made to improve the performance of BIPT systems. In a typical BIPT system, the output power is control using the pickup converter phase shift angle (PSA) while the primary converter regulates the input current. This paper proposes an optimized phase shift modulation strategy to minimize the coil losses of a series – series (SS) compensated BIPT system. In addition, a comprehensive study on the impact of power converters on the overall efficiency of the system is also presented. A closed loop controller is proposed to optimize the overall efficiency of the BIPT system. Theoretical results are presented in comparison to both simulations and measurements of a 0.5 kW prototype to show the benefits of the proposed concept. Results convincingly demonstrate the applicability of the proposed system offering high efficiency over a wide range of output power.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerical study has been performed in this study to investigate the turbulent convection heat transfer on a rectangular plate mounted over a flat surface. Thermal and fluid dynamic performances of extended surfaces having various types of lateral perforations with square, circular, triangular and hexagonal cross sections are investigated. RANS (Reynolds averaged Navier–Stokes) based modified k–ω turbulence model is used to calculate the fluid flow and heat transfer parameters. Numerical results are compared with the results of previously published experimental data and obtained results are in reasonable agreement. Flow and heat transfer parameters are presented for Reynolds numbers from 2000 to 5000 based on the fin thickness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flexor digitorum longus transfer and medial displacement alcaneal osteotomy is a wellrecognised form of treatment or stage II posterior tibial tendon dysfunction. Although excellent short- and medium-term results have been reported, the long-term outcome is unknown. We reviewed the clinical outcome of 31 patients with a symptomatic flexible flatfoot deformity who underwent this procedure between 1994 and 1996. There were 21 women and ten men with a mean age of 54.3 years (42 to 70). The mean follow-up was 15.2 years (11.4 to 16.5). All scores improved significantly (p < 0.001). The mean American Orthopedic Foot and Ankle Society (AOFAS) score improved from 48.4 pre-operatively to 90.3 (54 to 100) at the final follow-up. The mean pain component improved from 12.3 to 35.2 (20 to 40). The mean function score improved from 35.2 to 45.6 (30 to 50). The mean visual analogue score for pain improved from 7.3 to 1.3 (0 to 6). The mean Short Form-36 physical component score was 40.6 (SD 8.9), and this showed a significant correlation with the mean AOFAS score (r = 0.68, p = 0.005). A total of 27 patients (87%) were pain free and functioning well at the final follow-up. We believe that flexor digitorum longus transfer and calcaneal osteotomy provides long-term pain relief and satisfactory function in the treatment of stage II posterior tibial tendon dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Typical wireless power transfer systems utilize series compensation circuit which is based on magnetic coupling and resonance principles that was first developed by Tesla. However, changes in coupling caused by gap distance, alignment and orientation variations can lead to reduce power transfer efficiencies and the transferred power levels. This paper proposes impedance matched circuit to reduce frequency bifurcation effect and improve on the transferred power level, efficiency and total harmonic distortion (THD) performance of the series compensation circuit. A comprehensive mathematical analysis is performed for both series and impedance matched circuits to show the frequency bifurcation effects in terms of input impedance, variations in transferred power levels and efficiencies. Matlab/Simulink results validate the theoretical analysis and shows the circuits’ THD performance when circuits are fed with power electronic converters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Achieving high efficiency with improved power transfer range and misalignment tolerance is the major design challenge in realizing Wireless Power Transfer (WPT) systems for industrial applications. Resonant coils must be carefully designed to achieve highest possible system performance by fully utilizing the available space. High quality factor and enhanced electromagnetic coupling are key indices which determine the system performance. In this paper, design parameter extraction and quality factor optimization of multi layered helical coils are presented using finite element analysis (FEA) simulations. In addition, a novel Toroidal Shaped Spiral (TSS) coil is proposed to increase power transfer range and misalignment tolerance. The proposed shapes and recommendations can be used to design high efficiency WPT resonator in a limited space.