973 resultados para TRAP assay
Resumo:
The LPT (Lanzhou Penning Trap) is under construction and its task is to perforin direct mass measurement of fusion-evaporation residue, and if possible for heavy isotopes. Detailed simulations have been clone for a good understanding to the ion's movement and mechanics in the trap. The optimizal ion of the LPT is also performed based on the simulation. With a scale of 0.5 mm per grid used in the, simulation and many other limitations a highest mass resolution has been achieved to be 1.9 x 10(-5). An unexpected behavioin in the simulation related to magnetron motion has been found.
Resumo:
DNA damage and cell reproductive death determined by alkaline comet and clonogenic survival assays were examined in Lewis lung carcinoma cells after exposure to 89.63 MeV/u carbon ion and 6 MV X-ray irradiations, respectively. Based on the survival data, Lewis lung carcinoma cells were verified to be more radiosensitive to the carbon ion beam than to the X-ray irradiation. The relative biological effectiveness (RBE) value, which was up to 1.77 at 10% survival level, showed that the DNA damage induced by the high-LET carbon ion beam was more remarkable than that induced by the low-LET X-ray irradiation. The dose response curves of '' Tail DNA (%)'' (TD) and "Olive tail moment" (OTM) for the carbon ion irradiation showed saturation beyond about 8 Gy. This behavior was not found in the X-ray curves. Additionally, the carbon ion beam produced a lower survival fraction at 2 Gy (SF2) value and a higher initial Olive tail moment 2 Gy (OTM2) than those for the X-ray irradiation. These results suggest that carbon ion beams having high-LET values produced more severe cell reproductive death and DNA damage in Lewis lung carcinoma cells in comparison with X-rays and comet assay might be an effective predictive test even combining with clonogenic assay to assess cellular radio sensitivity
Resumo:
Aim: To determine whether the number of non-rejoining G2-chromatid breaks can predict the radiosensitivity of human cell lines. Methods: Cell lines of human ovary carcinoma cells (HO8910), human hepatoma cells (HepG2) and liver cells (L02) were irradiated with a range of doses and assessed both of cell survival and non-rejoining G2-chromatid breaks at 24 h after irradiation. Cell survival was documented by a colony assay. Non-rejoining G2-chromatid breaks were measured by counting the number of non-rejoining G2 chromatid breaks at 24 h after irradiation, detected by the prematurely chromosome condensed (PCC) technique. Results: A linear-quadratic survival curve was observed in three cell lines, and HepG2 was the most sensitive to gamma-radiation. A dose-dependent linear increase was observed in radiation-induced non-rejoining G2-PCC breaks measured at 24 h after irradiation in all cell lines, and HepG2 was the most susceptible to induction of non-rejoining G2-PCC breaks. A close correlation was found between the clonogenic radiosensitivity and the radiation-induced non-rejoining G2-PCC breaks (r=0.923). Furthermore, survival-aberration correlations for two or more than two doses lever were also significant. Conclusion: The number of non-rejoining G2 PCC breaks holds considerable promise for predicting the radiosensitivity of normal and tumor cells when two or more than two doses lever is tested.
Resumo:
The Penning trap mass spectrometer SHIPTRAP at GSI Darmstadt allows accurate mass measurements of radionuclides, produced in fusion-evaporation reactions and separated by the velocity filter SHIP from the primary beam. Recently, the masses of the three nobelium isotopes No252-254 were determined. These are the first direct mass measurements of transuranium elements, which provide new anchor points in this region. The heavy nuclides were produced in cold-fusion reactions by irradiating a PbS target with a Ca-48 beam, resulting in production rates of the nuclei of interest of about one atom per second. In combination with data from decay spectroscopy our results are used to perform a new atomic-mass evaluation in this region.
Resumo:
A Penning trap system called Lanzhou Penning Trap (LPT) is now being developed for precise mass measurements at the Institute of Modern Physics (IMP). One of the key components is a 7 T actively shielded superconducting magnet with a clear warm bore of 156 mm. The required field homogeneity is 3 x 10(-7) over two 1 cubic centimeter volumes lying 220 mm apart along the magnet axis. We introduce a two-step method which combines linear programming and a nonlinear optimization algorithm for designing the multi-section superconducting magnet. This method is fast and flexible for handling arbitrary shaped homogeneous volumes and coils. With the help of this method an optimal design for the LPT superconducting magnet has been obtained.
Resumo:
A penning trap system called LPT (LANZHOU PENNING TRAP) is now being developed for precise mass measurements in IMP (Institute of Modern Physics). The most key component of LPT is a superconducting magnet. A Phi 156 mm warm bore and two cylinder good field regions with a distance of 220 mm are required for trapping ions and measurements. As the required homogeneity is better than 0.5 ppm, several complicated coaxial coils are used to produce such a magnetic field. The size and position of these coils are optimized by using a method combining linear program with multiobjective optimization. Superconducting shim coils and passive shim pieces are used to eliminate inevitable winding tolerances and environmental influence. The fringe field is decreased to 5 Gs at 2 m line from the center of the magnet by active shielding coils. The designs of the mechanical structure, the quench protection system are also introduced in this paper.
Resumo:
Since protein phosphorylation is a dominant mechanism of information transfer in cells, there is a great need for methods capable of accurately elucidating sites of phosphorylation. In recent years mass spectrometry has become an increasingly viable alternative to more traditional methods of phosphorylation analysis. The present study used immobilized metal affinity chromatography (IMAC coupled with a linear ion trap mass spectrometer to analyze phosphorylated proteins in mouse liver. A total of 26 peptide sequences defining 26 sites of phosphorylation were determined. Although this number of identified phosphoproteins is not large, the approach is still of interest because a series of conservative criteria were adopted in data analysis. We note that, although the binding of non-phosphorylated peptides to the IMAC column was apparent, the improvements in high-speed scanning and quality of MS/MS spectra provided by the linear ion trap contributed to the phosphoprotein identification. Further analysis demonstrated that MS/MS/MS analysis was necessary to exclude the false-positive matches resulting from the MS/MS experiments, especially for multiphosphorylated peptides. The use of the linear ion trap considerably enabled exploitation of nanoflow-HPLC/MS/MS, and in addition MS/MS/MS has great potential in phosphoproteome research of relatively complex samples. Copyright (C) 2004 John Wiley Sons, Ltd.
Resumo:
A method for calibration of an audio-frequency (AF) ion trap mass spectrometer is described. The method is proposed to surmount the obstacle that there is a lack of a proper calibrant for mass spectrometers in the mass-to-charge ratio (m/z) range of 10(6) to 10(10). To calibrate such mass spectra, we determine the point of ejection, q(eject), on the stability diagram of the ion trap operated in a mass-selective axial instability mode. This is accomplished by measuring the radial secular frequencies (and therefore, the m/z value) of a single trapped particle using a light scattering method, followed by monitoring the action of particle ejection in real time to obtain the q(eject). A delayed ejection with q(eject) = 0.949 +/- 0.004 is found at a trap driving frequency of Ohm/2pi = 200-600Hz. Theoretical analysis for the origin of the delayed ejection indicates that the delay is predominantly resulted from the existence of multipole components in the fields due to trap imperfections. Inclusion of -3% of the octopole with respect to the basic quadrupole field can satisfactorily account for our observations. An m/z accuracy approaching 0.1% is attainable after proper calibration of the AF ion trap mass spectrometer. (Int J Mass Spectrom 214 (2002) 63-73) (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
Colorimetric assay based on the unique surface plasmon resonance properties of metallic nanoparticles has received considerable attention in bioassay due to its simplicity, high sensitivity, and low cost. Most of colorimetric methods previously reported employed gold nanoparticles (GNPs) as sensing elements. In this work, we develop a sensitive, selective, simple, and label-free colorimetric assay using unmodified silver nanoparticle (AgNP) probes to detect enzymatic reactions. Enzymatic reactions concerning adenosine triphosphate (ATP) dephosphorylation by calf intestine alkaline phosphatase (CLAP) and peptide phosphorylation by protein kinase A (PKA) were studied.
Resumo:
A simple, rapid and ultrasensitive colorimetric detection of protein using aptamer-Au nanoparticles (AuNPs) conjugates based on a dot-blot array has been developed, which was combined with the unique optical properties of AuNPs, enabling the visual detection of protein within minutes without any instrument.
Resumo:
Based on the dimer-monomer equilibrium movement of the fluorescent dye Pyronin Y (PY), a rapid, simple, highly sensitive, label-free method for protein detection was developed by microchip electrophoresis with LIF detection. PY formed a nonfluorescent dimer induced by the premicellar aggregation of an anionic surfactant, SDS, however, the fluorescence intensity of the system increased dramatically when proteins such as BSA, bovine hemoglobin, cytochrome c, and trypsin were added to the solution due to the transition of dimer to fluorescent monomer. Furthermore, 1-ethyl-3-methylimidazolium tetrafluoroborate (EMImBF(4)) instead of PBS was applied as running buffers in microchip electrophoresis.