988 resultados para Sun: magnetic fields
Resumo:
As wind power generation undergoes rapid growth, lightning damages involving wind turbines have come to be regarded with more attention. Electric and magnetic fields generated by lightning represent a serious hazard to wind turbines. A new case study is presented with two interconnected wind turbines, considering that lightning strikes directly the blade of one wind turbine. Computer simulations obtained by using EMTP-RV are presented and conclusions are duly drawn.
Resumo:
The main objective of this review is to provide a descriptive analysis of the biological and physiological markers of tactile sensorial processing in healthy, full-term newborns. Research articles were selected according to the following study design criteria: (a) tactile stimulation for touch sense as an independent variable; (b) having at least one biological or physiological variable as a dependent variable; and (c) the group of participants were characterized as full-term and healthy newborns; a mixed group of full-term newborns and preterm newborns; or premature newborns with appropriate-weight-for-gestational age and without clinical differences or considered to have a normal, healthy somatosensory system. Studies were then grouped according to the dependent variable type, and only those that met the aforementioned three major criteria were described. Cortisol level, growth measures, and urinary catecholamine, serotonin, and melatonin levels were reported as biological-marker candidates for tactile sensorial processing. Heart rate, body temperature, skin-conductance activity, and vagal reactivity were described as neurovegetative-marker candidates. Somatosensory evoked potentials, somatosensory evoked magnetic fields, and functional neuroimaging data also were included.
Resumo:
The CMS Safety Closing Sensors System (SCSS, or CSS for brevity) is a remote monitoring system design to control safety clearance and tight mechanical movements of parts of the CMS detector, especially during CMS assembly phases. We present the different systems that makes SCSS: its sensor technologies, the readout system, the data acquisition and control software. We also report on calibration and installation details, which determine the resolution and limits of the system. We present as well our experience from the operation of the system and the analysis of the data collected since 2008. Special emphasis is given to study positioning reproducibility during detector assembly and understanding how the magnetic fields influence the detector structure.
Resumo:
The quasi two-dimensional electron gas (q2DEG) hosted in the interface of an epitaxially grown lanthanum aluminate (LaAlO3) thin film with a TiO2-termi-nated strontium titanate (SrTiO3) substrate (001) has been massively studied in the last few years. The confinement of mobile electrons to within a few nanome-ters from the interface, superconductive behavior at low temperatures and elec-tron mobility exceeding 1000 cm2/(V.s) make this system an interesting candi-date to explore the physics of spin injection and transport. However, due to the critical thickness for conduction of 4 unit cells (uc) of LaAlO3, a high tunneling resistance hampers electrical access to the q2DEG, preventing proper injection of spin polarized current. Recently, our group found that depositing a thin overlayer of Co on LaAlO3 reduces the critical thickness, enabling conduction with only 1 uc of LaAlO3. Two scenarios arise to explain this phenomenon: a pinning of the Fermi level in the metal, inducing charge transfer in the SrTiO3; the creation of oxygen vacancies at the interface between LaAlO3 and the metal, leading to an n-type doping of the SrTiO3. In this dissertation, we will report on magnetotransport of metal/LaAlO3/SrTiO3 (metal: Ti, Ta, Co, Py, Au, Pt, Pd) heterostructures with 2 uc of LaAlO3 studied at low temperatures (2 K) and high magnetic fields (9 T). We have analyzed the transport properties of the gas, namely, the carrier concen-tration, mobility and magnetotransport regime and we will discuss the results in the light of the two scenarios mentioned above.
Resumo:
Companies and researchers involved in developing miniaturized electronic devices face the basic problem of the needed batteries size, finite life of time and environmental pollution caused by their final deposition. The current trends to overcome this situation point towards Energy Harvesting technology. These harvesters (or scavengers) store the energy from sources present in the ambient (as wind, solar, electromagnetic, etc) and are costless for us. Piezoelectric devices are the ones that show a higher power density, and materials as ceramic PZT or polymeric PVDF have already demonstrated their ability to act as such energy harvester elements. Combinations between piezoelectric and electromagnetic mechanism have been also extensively investigated. Nevertheless, the power generated by these combinations is limited under the application of small magnetic fields, reducing the performance of the energy harvester [1]. In the last years the appearance of magnetoelectric (ME) devices, in which the piezoelectric deformation is driven by the magnetostrictive element, enables to extract the energy of very small electromagnetic signals through the generated magnetoelectric voltage at the piezoelectric element. However, very little work has been done testing PVDF polymer as piezoelectric constituent of the ME energy harvester device, and only to be proposed as a possibility of application [2]. Among the advantages of using piezopolymers for vibrational energy harvesting we can remember that they are ductile, resilient to shock, deformable and lightweight. In this work we demonstrate the feasibility of using magnetostrictive Fe-rich magnetic amorphous alloys/piezoelectric PVDF sandwich-type laminated ME devices as energy harvesters. A very simple experimental set-up will show how these laminates can extract energy, in amounts of W, from an external AC field.
Resumo:
We investigate the spontaneous emission rate of a two-level quantum emitter near a graphene-coated substrate under the influence of an external magnetic field or strain induced pseudo-magnetic field. We demonstrate that the application of the magnetic field can substantially increase or decrease the decay rate. We show that a suppression as large as 99$\%$ in the Purcell factor is achieved even for moderate magnetic fields. The emitter's lifetime is a discontinuous function of $|{\bf B}|$, which is a direct consequence of the occurrence of discrete Landau levels in graphene. We demonstrate that, in the near-field regime, the magnetic field enables an unprecedented control of the decay pathways into which the photon/polariton can be emitted. Our findings strongly suggest that a magnetic field could act as an efficient agent for on-demand, active control of light-matter interactions in graphene at the quantum level.
Resumo:
Dissertao de mestrado integrado em Engenharia Eletrnica Industrial e Computadores
Resumo:
Dissertao de mestrado integrado em Engenharia Eletrnica Industrial e Computadores
Resumo:
Dissertao de mestrado em Biofsica e Bionanossistemas
Resumo:
() () .
Resumo:
La Teoria de la Relativitat General preveu que quan un objecte massiu s sotms a una certa acceleraci en certes condicions ha demetre ones gravitacionals. Es tracta dun tipus don altament energtica per que interacciona amb la matria de manera molt feble i el seu punt demissi s fora lluny. Per la qual cosa la seva detecci s una tasca extraordinriament complicada. Conseqentment, la detecci daquestes ones es creu molt ms factible utilitzant instruments situats a lespai. Amb aquest objectiu, neis la missi LISA (Laser Interferometer Space Antenna). Es tracta aquesta duna missi conjunta entre la NASA i lESA amb llanament previst per 2020-2025. Per reduir els riscs que comporta una primera utilitzaci de tecnologia no testejada, unit a lalt cost econmic de la missi LISA. Aquesta missi contindr instruments molt avanats: el LTP (LISA Technoplogy Package), desenvolupat per la Uni Europea, que provar la tecnologia de LISA i el Drag Free flying system, que sencarregar de provar una srie de propulsors (thrusters) utilitzats per al control dactitud i posici de satllit amb precisi de nanmetres. Particularment, el LTP, est composat per dues masses de prova separades per 35 centmetres, i dun interfermetre lser que mesura la variaci de la distncia relativa entre elles. Daquesta manera, el LTP mesurar les prestacions dels equips i les possibles interferncies que afecten a la mesura. Entre les fonts de soroll es troben, entre daltres, el vent i pressi de radiaci solar, les crregues electrosttiques, el gradient trmic, les fluctuacions de voltatge o les forces internes. Una de les possibles causes de soroll s aquella que ser lobjecte destudi en aquest projecte de tesi doctoral: la presncia dintre del LTP de camps magntics, que exerceixen una fora sobre les masses de prova, la seva estimaci i el seu control, prenent en compte les caracterrstiques magntiques de lexperiment i la dinmica del satllit.
Resumo:
The large spatial inhomogeneity in transmit B, field (B-1(+)) observable in human MR images at hi h static magnetic fields (B-0) severely impairs image quality. To overcome this effect in brain T-1-weighted images the, MPRAGE sequence was modified to generate two different images at different inversion times MP2RAGE By combining the two images in a novel fashion, it was possible to create T-1-weigthed images where the result image was free of proton density contrast, T-2* contrast, reception bias field, and, to first order transmit field inhomogeneity. MP2RAGE sequence parameters were optimized using Bloch equations to maximize contrast-to-noise ratio per unit of time between brain tissues and minimize the effect of B-1(+) variations through space. Images of high anatomical quality and excellent brain tissue differentiation suitable for applications such as segmentation and voxel-based morphometry were obtained at 3 and 7 T. From such T-1-weighted images, acquired within 12 min, high-resolution 3D T-1 maps were routinely calculated at 7 T with sub-millimeter voxel resolution (0.65-0.85 mm isotropic). T-1 maps were validated in phantom experiments. In humans, the T, values obtained at 7 T were 1.15 +/- 0.06 s for white matter (WM) and 1.92 +/- 0.16 s for grey matter (GM), in good agreement with literature values obtained at lower spatial resolution. At 3 T, where whole-brain acquisitions with 1 mm isotropic voxels were acquired in 8 min the T-1 values obtained (0.81 +/- 0.03 S for WM and 1.35 +/- 0.05 for GM) were once again found to be in very good agreement with values in the literature. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
One of the unresolved questions of modern physics is the nature of Dark Matter. Strong experimental evidences suggest that the presence of this elusive component in the energy budget of the Universe is quite significant, without, however, being able to provide conclusive information about its nature. The most plausible scenario is that of weakly interacting massive particles (WIMPs), that includes a large class of non-baryonic Dark Matter candidates with a mass typically between few tens of GeV and few TeVs, and a cross section of the order of weak interactions. Search for Dark Matter particles using very high energy gamma-ray Cherenkov telescopes is based on the model that WIMPs can self-annihilate, leading to production of detectable species, like photons. These photons are very energetic, and since unreflected by the Universe's magnetic fields, they can be traced straight to the source of their creation. The downside of the approach is a great amount of background radiation, coming from the conventional astrophysical objects, that usually hides clear signals of the Dark Matter particle interactions. That is why good choice of the observational candidates is the crucial factor in search for Dark Matter. With MAGIC (Major Atmospheric Gamma-ray Imaging Cherenkov Telescopes), a two-telescope ground-based system located in La Palma, Canary Islands, we choose objects like dwarf spheroidal satellite galaxies of the Milky Way and galaxy clusters for our search. Our idea is to increase chances for WIMPs detection by pointing to objects that are relatively close, with great amount of Dark Matter and with as-little-as-possible pollution from the stars. At the moment, several observation projects are ongoing and analyses are being performed.
Resumo:
Els monopols es defineixen, tericament, com crregues que generen camps amb divergncia diferent de cero. Malgrat aix, les entitats amb comportament mimtic al dels monopols magntics, segueix sent compatible amb B=0, han estat detectades experimentalment en gels despn (spin-ices). Aquesta aparent contradicci pot generar confusi i, per tant, requereix explicaci. Daltra banda, sestudien propietats duals del materials amb crregues magntiques efectives tals com la magnetricity en els spinices (conductivitat de les crregues magntiques davant un camp magntic extern). Com una conseqncia de la magnetricitat, lapantallament del camp magntic en materials amb crregues magntiques s analitzat. Estudio la propagaci dones electromagntiques transversals en medis materials infinits i en plasmes magntics diluts davant la presncia de camps elctrics externs constants. Aquesta propagaci s dual a la propagaci dones en plasmes de crregues elctriques davant la presncia de camps magntics externs, constants. Finalment, estudio el frenat elctric dun conductor de crregues magntiques amb un efecte dual al frenat magntic en conductors elctrics.
Resumo:
In vivo localized proton magnetic resonance spectroscopy (1H MRS) became a powerful and unique technique to non-invasively investigate brain metabolism of rodents and humans. The main goal of 1H MRS is the reliable quantification of concentrations of metabolites (neurochemical profile) in a well-defined region of the brain. The availability of very high magnetic field strengths combined with the possibility of acquiring spectra at very short echo time have dramatically increased the number of constituents of the neurochemical profile. The quantification of spectra measured at short echo times is complicated by the presence of macromolecule signals of particular importance at high magnetic fields. An error in the macromolecule estimation can lead to substantial errors in the obtained neurochemical profile. The purpose of the present review is to overview methods of high field 1H MRS with a focus on the metabolite quantification, in particular in handling signals of macromolecules. Three main approaches of handling signals of macromolecules are described, namely mathematical estimation of macromolecules, measurement of macromolecules in vivo, and direct acquisition of the in vivo spectrum without the contribution of macromolecules.