989 resultados para Solid-surfaces
Resumo:
This paper, reports experimental work on the use of new heterogeneous solid basic catalysts for biodiesel production: double oxides of Mg and Al, produced by calcination, at high temperature, of MgAl lamellar structures, the hydrotalcites (HT). The most suitable catalyst system studied are hydrotalcite Mg:Al 2:1 calcinated at 507 degrees C and 700 degrees C, leading to higher values of FAME also in the second reaction stage. One of the prepared catalysts resulted in 97.1% Fatty acids methyl esters (FAME) in the 1st reaction step, 92.2% FAME in the 2nd reaction step and 34% FAME in the 3rd reaction step. The biodiesel obtained in the transesterification reaction showed composition and quality parameters within the limits specified by the European Standard EN 14214. 2.5% wt catalyst/oil and a molar ratio methanol:oil of 9:1 or 12:1 at 60 -65 degrees C and 4 h of reaction time are the best operating conditions achieved in this study. This study showed the potential of Mg/Al hydrotalcites as heterogeneous catalysts for biodiesel production. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Na indústria farmacêutica, a limpeza dos equipamentos e superfícies é muito importante no processo de fabrico/embalagem dos produtos farmacêuticos. Possíveis resíduos contaminantes devem ser removidos dos equipamentos e das superfícies envolvidas no processo. De acordo com as Boas Práticas de Fabrico (GMP), os procedimentos de limpeza e os métodos analíticos usados para determinar as quantidades de resíduos devem ser validados. O método analítico combinado com o método de amostragem utilizado na colheita de amostras deve ser sujeito a um ensaio de “recovery”. Neste trabalho apresenta-se uma estratégia inovadora para a validação de limpeza de formas farmacêuticas semi-sólidas. Propõe-se o uso de um método de amostragem que consiste na colheita direta de amostra após o seu fabrico, sendo a análise de resíduos feita directamente nesta amostra. Os produtos escolhidos para a avaliação da estratégia foram dois medicamentos dermatológicos, apresentados na forma de pomada e produzidos numa unidade de fabrico de vários produtos, pela Schering Plough Farma/ Merck Sharp & Dohme (Cacém, Portugal). Como métodos analíticos para a quantificação dos resíduos, utilizaram-se métodos validados por via espectrofotométrica (HPLC), usados na análise do produto acabado. A validação de limpeza foi avaliada através da análise de uma quantidade conhecida de pomada (produto B (*)), usando o método de análise da pomada fabricada anteriormente (produto A (*)), de modo a verificar-se a existência ou não de agente de limpeza e substâncias ativas deixadas após a limpeza do produto A, e vice-versa. As concentrações residuais das substâncias ativas e do agente de limpeza encontradas após a limpeza foram nulas, ou seja, inferiores ao limite de deteção (LOD), sendo que o critério de aceitação da limpeza utilizado foi de 6,4 x 10-4 mg/g para a substância ativa 1 (*); 1,0 x 10-2 mg/g para a substância ativa 2 (*); 1,0 x 10-3 mg/g para a substância ativa 3 (*) e de 10 ppm para o agente de limpeza. No ensaio de “recovery”, obtiveram-se resultados acima de 70% para todas as substâncias ativas e para o agente de limpeza nas duas pomadas. Antes de se proceder a este ensaio de “recovery”, houve a necessidade de ajustar as condições cromatográficas dos métodos analíticos de ambos os produtos e do agente de limpeza, por forma a obter-se valores da conformidade do sistema (fator de tailling e de resolução) de acordo com as especificações. A precisão dos resultados, reportada como desvio padrão relativo (RSD), deu abaixo de 2,0%, excepto nos ensaios que envolvem a substância ativa 3, cuja especificação é inferior a 10,0%. Os resultados obtidos demonstraram que os procedimentos de limpeza usados na unidade de fabrico em causa são eficazes, eliminando assim a existência de contaminação cruzada.
Resumo:
A multiresidue gas chromatographic method for the determination of six fungicides (captan, chlorthalonil, folpet, iprodione, procymidone and vinclozolin) and one acaricide (dicofol) in still and fortified wines was developed. Solid-phase microextraction (SPME) was chosen for the extraction of the compounds from the studied matrices and tandem mass spectrometry (MS/MS) detection was used. The extraction consists in a solvent free and automated procedure and the detection is highly sensitive and selective. Good linearity was obtained with correlation coefficients of regression (R2) > 0.99 for all the compounds. Satisfactory results of repeatability and intermediate precision were obtained for most of the analytes (RSD < 20%). Recoveries from spiked wine ranged from 80.1% to 112.0%. Limits of quantification (LOQs) were considerably below the proposedmaximumresidue limits (MRLs) for these compounds in grapes and below the suggested limits for wine (MRLs/10), with the exception of captan.
Resumo:
During the last years there has been an increasing concern about occupational exposure to cytostatic drugs in hospitals. The first findings on occupational exposures among hospital personnel administering chemotherapy were reported only in 1979. Since then, a great number of studies have been publishing describing possible exposure-related health effects. Consequently, rigorous guidelines for the safe handling of cancer chemotherapeutic agents were devised and the handling facilities in hospitals were extensively improved. However, recent studies developed in European countries revealed detectable amounts of several drugs in surface wipe samples. Dermal absorption after contact with contaminated surfaces can play an important role in exposure to antineoplastic drugs. Therefore, the existence of contamination in workplace surfaces implies an increased risk of exposure for health care workers. Since there is no recent report in Portugal, regarding the occupational exposure to antineoplastic drugs, a study was developed aiming to determine the 5-fluorouracil (5-FU) contamination on work surfaces of two Portuguese hospitals.
Resumo:
Organic waste is a rich substrate for microbial growth, and because of that, workers from waste industry are at higher risk of exposure to bioaerosols. This study aimed to assess fungal contamination in two plants handling solid waste management. Air samples from the two plants were collected through an impaction method. Surface samples were also collected by swabbing surfaces of the same indoor sites. All collected samples were incubated at 27◦C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. Air samples were also subjected to molecular methods by real-time polymerase chain reaction (RT PCR) using an impinger method to measure DNA of Aspergillus flavus complex and Stachybotrys chartarum. Assessment of particulate matter (PM) was also conducted with portable direct-reading equipment. Particles concentration measurement was performed at five different sizes (PM0.5; PM1; PM2.5; PM5; PM10). With respect to the waste sorting plant, three species more frequently isolated in air and surfaces were A. niger (73.9%; 66.1%), A. fumigatus (16%; 13.8%), and A. flavus (8.7%; 14.2%). In the incineration plant, the most prevalent species detected in air samples were Penicillium sp. (62.9%), A. fumigatus (18%), and A. flavus (6%), while the most frequently isolated in surface samples were Penicillium sp. (57.5%), A. fumigatus (22.3%) and A. niger (12.8%). Stachybotrys chartarum and other toxinogenic strains from A. flavus complex were not detected. The most common PM sizes obtained were the PM10 and PM5 (inhalable fraction). Since waste is the main internal fungal source in the analyzed settings, preventive and protective measures need to be maintained to avoid worker exposure to fungi and their metabolites.
Resumo:
Despite the classification as known or suspected human carcinogens, by the International Agency for Research on Cancer, the antineoplastic drugs are extensively used in cancer treatment due to their specificity and efficacy. As human carcinogens, these drugs represent a serious threat to the healthcare workers involved in their preparation and administration. This work aims to contribute to better characterize the occupational exposure of healthcare professionals to antineoplastic drugs, by assessing workplace surfaces contamination of pharmacy and administration units of two Portuguese hospitals. Surface contamination was assessed by the determination of cyclophosphamide, 5-fluorouracil, and paclitaxel. These three drugs were used as surrogate markers for surfaces contamination by cytotoxic drugs. Wipe samples were taken and analyzed by HPLCDAD. From the total of 327 analyzed samples, in 121 (37%) was possible to detect and quantify at least one drug. Additionally, 28 samples (8.6 %) indicate contamination by more than one antineoplastic drug, mainly in the administration unit, in both hospitals. Considering the findings in both hospitals, specific measures should be taken, particularly those related with the promotion of good practices and safety procedures and also routine monitoring of surfaces contamination in order to guarantee the appliance of safety measures.
Resumo:
Background - The use of antineoplastic drugs in cancer therapy is increasing due to their action in cancer cells. Carcinogenic, mutagenic and teratogenic effects. Some studies demonstrated that nurses and pharmacy personnel involved in preparation or administration are exposed to antineoplastic drugs. Aim: assess 5-Fluorouracil (5-FU) contamination on the surfaces of two Portuguese Hospitals (preparation and administration units). 5-FU is one of the most frequently antineoplastic agent used in Portuguese Hospitals and can be easily absorbed through the skin. This drug can be used as an marker of surfaces contamination and exposure and have been extensively discussed in other studies.
Resumo:
A nanohybrid electrochemical transducer surface was developed using carbon and gold nanomaterials. The strategy relayed on casting multiwalled carbon nanotubes or carbon nanofibers onto a screen-printed carbon electrode surface, followed by in situ generation of gold nanoparticles by electrochemical deposition of ionic gold, in a reproducible manner. These transducers, so fabricated, were characterized using both electrochemical and microscopic techniques. Biofunctionality was evaluated using the streptavidin-biotin interaction system as the biological reaction model. These platforms allow to achieve low detection limits (in the order of pmoles), are reproducible and stable at least for a month after their preparation, being a perfect candidate to be used as transducer of different sensor devices.
Resumo:
A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.
Resumo:
A SPME-GC-MS/MS method for the determination of eight organophosphorus pesticides (azinphos-methyl, chlorpyriphos, chlorpyriphos-methyl, diazinon, fenitrothion, fenthion, malathion, and methidathion) in still and fortified wine was developed. The extraction procedure is simple, solvent free, and without any sample pretreatment. Limits of detection (LOD) and quantitation (LOQ) values in the range 0.1–14.3 lg/L and 0.2–43.3 lg/L, respectively, were obtained. The LOQ values are below the maximum residue levels (MRLs) established by European Regulation for grapes, with the exception of methidathion. Coefficients of correlation (R2) higher than 0.99 were obtained for the majority of the pesticides, in all different wines analyzed.
Resumo:
The present work describes a solid-phase microextraction (SPME) gas chromatography_tandem mass spectrometry (MS/MS) method to quantify 24 pesticides in fortified white wine and fortified red wine. In this study “fortified wine” refers to a wine in which fermentation is arrested before completion by alcohol distillate addition, allowing sugar and alcoholic contents to be higher (around 80-100 g/L total sugars and 19-22% alcohol strength (v/v)). The analytical method showed good linearity, presenting correlation coefficients (R2) ≥ 0.989 for all compounds. Limits of detection (LOD) and quantitation (LOQ) in the ranges of 0.05-72.35 and 0.16-219.23 μg/L, respectively, were obtained. LOQs are below the maximum residue levels (MRL) set by European Regulation for grapes. The proposed method was applied to 17 commercial fortified wines. The analyzed pesticides were not detected in the wines tested.
Resumo:
This work proposes a new biomimetic sensor material for trimethoprim. It is prepared by means of radical polymerization, having trimethylolpropane trimethacrylate as cross-linker, benzoyl peroxide as radicalar iniciator, chloroform as porogenic solvent, and methacrylic acid and 2-vinyl pyridine as monomers. Different percentages of sensor in a range between 1 and 6% were studied. Their behavior was compared to that obtained with ion-exchanger quaternary ammonium salt (additive tetrakis(p-chlorophenyl)borate or tetraphenylborate). The effect of an anionic additive in the sensing membrane was also tested. Trimethoprim sensors with 1% of imprinted particles from methacrylic acid monomers showed the best response in terms of slope (59.7 mV/decade) and detection limit (4.01×10−7 mol/L). These electrodes displayed also a good selectivity towards nickel, manganese aluminium, ammonium, lead, potassium, sodium, iron, chromium, sulfadiazine, alanine, cysteine, tryptophan, valine and glycine. The sensors were not affected by pH changes from 2 to 6. They were successfully applied to the analysis of water from aquaculture.
Resumo:
QuEChERS original method was modified into a new version for pesticides determination in soils. The QuEChERS method is based on liquid–liquid portioning with ACN and was followed by cleanup step using dispersive SPE and disposable pipette tips. Gas chromatographic separation with MS detection was carried out for pesticides quantification. The method was validated using recovery experiments for 36 multiclass pesticides. Mean recoveries of pesticides at each of the four spiking levels between 10–300 µg/kg of soil ranged from 70–120% for 26 pesticides with RSD values less than 15%. The method achieved low limit of detection less than 7.6 µ g/kg. Matrix effects were observed for 13 pesticides. Matrix effects were compensated by using matrix-matched calibration. The method was applied successfully using d-SPE or DPX in the analysis of the pesticides in soils from organic farming and integrated pest management.
Resumo:
This paper describes a modular solid-state switching cell derived from the Marx generator concept to be used in topologies for generating multilevel unipolar and bipolar high-voltage (HV) pulses into resistive loads. The switching modular cell comprises two ON/OFF semiconductors, a diode, and a capacitor. This cell can be stacked, being the capacitors charged in series and their voltages balanced in parallel. To balance each capacitor voltage without needing any parameter measurement, a vector decision diode algorithm is used in each cell to drive the two switches. Simulation and experimental results, for generating multilevel unipolar and bipolar HV pulses into resistive loads are presented.
Resumo:
The electrooxidative behavior of pravastatin (PRV) in aqueous media was studied by square-wave voltammetry at a glassycarbon electrode (GCE) and at a screen-printed carbon electrode (SPCE). Maximum peak current intensities in a pH 5.0 buffer were obtained at +1.3 V vs. AgCl/Ag and +1.0 V vs. Ag for the GCE and SPCE surface respectively. Validation of the developed methodologies revealed good performance characteristics and confirmed their applicability to the quantification of PRV in pharmaceutical products, without significant sample pretreatment. A comparative analysis between the two electrode types showed that SPCEs are preferred as an electrode surface because of their higher sensitivity and the elimination of the need to clean the electrode’s surface for its renewal, which frequently is, if not always, the rate-limiting step in voltammetric analysis.