923 resultados para Solar radiation sensors
Resumo:
The seasonal evolution of daily and hourly values of global and diffuse solar radiation at the surface are compared for the cities of Sao Paulo and Botucatu, both located in Southeast Brazil and representative of urban and rural areas, respectively. The comparisons are based on measurements of global and diffuse solar irradiance carried out at the surface during a six year simultaneous period in these two cities. Despite the similar latitude and altitude, the seasonal evolution of daily values indicate that Sao Paulo receives, during clear sky days, 7.8% less global irradiance in August and 5.1% less in June than Botucatu. On the other hand, Sao Paulo receives, during clear sky days, 3.6% more diffuse irradiance in August and 15.6% more in June than Botucatu. The seasonal variation of the diurnal cycle confirms these differences and indicates that they are more pronounced during the afternoon. The regional differences are related to the distance from the Atlantic Ocean, systematic penetration of the sea breeze and daytime evolution of the particulate matter in Sao Paulo. An important mechanism controlling the spatial distribution of solar radiation, on a regional scale, is the sea breeze penetration in Sao Paulo, bringing moisture and maritime aerosol that in turn further increases the solar radiation scattering due to pollution and further reduces the intensity of the direct component of solar radiation at the surface. Surprisingly, under clear sky conditions the atmospheric attenuation of solar radiation in Botucatu during winter - the biomass burning period due to the sugar cane harvest - is equivalent to that at Sao Paulo City, indicating that the contamination during sugar cane harvest in Southeast Brazil has a large impact in the solar radiation field at the surface.
Resumo:
The effect of increased UV radiation on photosynthesis estimated as in vivo chlorophyll fluorescence i.e. optimal quantum yield (F(v)/F(m)) and electron transport rate (ETR) in the green filamentous alga Zygnemopsis decussata (Streptophyta, Zygnematales) growing in the high mountain lake ""La Caldera"" (Sierra Nevada, Spain) at 3050 m altitude was evaluated. Two sets of in situ experiments were conducted: (1) On July 2006, F(v)/F(m) was measured throughout the day at different depths (0.1, 0.25, 0.5 and 1 m) and in the afternoon. ETR and phenolic compounds were determined. In addition, in order to analyze the effect of UV radiation, F(v)/F(m) was determined in algae incubated for 3 days at 0.5m under three different light treatments: PAR+UVA+UVB (PAB). PAR+UVA (PA) and PAR (P). (2) On August 2007, F(v)/F(m) was determined under PAB, PA and P treatments and desiccation/rehydration conditions. F(v)/F(m) decreased in algae growing in surface waters (0.1 m) but also at 1 m depth compared to that at 0.5 in depth. The decrease of F(v)/F(m) at noon due to photoinhibition was small (less than 10%) except in algae growing at 1 m depth (44%). The maximal electron transport rate was 3.5-5 times higher in algae growing at 0.25-0.5 m respectively than that at 0.1 and 1 m depth. These results are related to the accumulation of phenolic compounds: i.e. the algae at 0.25-0.5 in presentedrespectively about a 3-5 times higher concentration of phenolic compounds than that of algae at 0.1-1 m depth. The protection mechanisms seem to be stimulated by UVB radiation, since F(v)/F(m) was higher in the presence of UVB (PAB treatment) compared to PA or P treatments. UVA exerts the main photoinhibitory effect, not Only at midday, but also in the afternoon. UVB radiation also had a protective effect in algae grown under desiccation conditions for three days. During re-hydration, the rapid increase of F(v)/F(m) (after 1 h) was higher in the UVB-grown algae than in algae grown under UVA radiation. After 5 h. F(v)/F(m) values were similar in algae submitted to desiccation/rehydration under PAB and P treatments as they were in the control (submerged algae). The combined effect of desiccation and UVA produced the greatest decrease of photosynthesis in Z. decussata. Thifs UVB, in contrast to other species, may support the recovery process. Z. decussata can acclimate to severe stress, conditions in this high mountain lake by the photoprotection mechanism induced by UVB radiation through dynamic photoinhibition and the accumulation of phenolic compounds (UV screen and antioxidant substances).
Resumo:
Solar radiation sustains and affects all life forms on Earth. The increase in solar UV-radiation at environmental levels, due to depletion of the stratospheric ozone layer, highlights serious issues of social concern. This becomes still more dramatic in tropical and subtropical regions where radiation-intensity is still higher. Thus, there is the need to evaluate the harmful effects of solar UV-radiation on the DNA molecule as a basis for assessing the risks involved for human health, biological productivity and ecosystems. In order to evaluate the profile of DNA damage induced by this form of radiation and its genotoxic effects, plasmid DNA samples were exposed to artificial-UV lamps and directly to sunlight. The induction of cyclobutane pyrimidine dimer photoproducts (CPDs) and oxidative DNA damage in these molecules were evaluated by means of specific DNA repair enzymes. On the other hand, the biological effects of such lesions were determined through the analysis of the DNA inactivation rate and mutation frequency, after replication of the damaged pCMUT vector in an Escherichia coli MBL50 strain. The results indicated the induction of a significant number of CPDs after exposure to increasing doses of UVC, UVB, UVA radiation and sunlight. Interestingly, these photoproducts are those lesions that better correlate with plasmid inactivation as well as mutagenesis, and the oxidative DNA damages induced present very low correlation with these effects. The results indicated that DNA photoproducts play the main role in the induction of genotoxic effects by artificial UV-radiation sources and sunlight. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
This Thesis project is a part of the research conducted in Solar industry. ABSOLICON Solar Concentrator AB has invented and started production of the prospective solar concentrated system Absolicon X10. The aims of this Thesis project are designing, assembling, calibrating and putting in operation the automatic measurement system intended to evaluate distribution of density of solar radiation in the focal line of the concentrated parabolic reflectors and to measure radiation from the artificial source of light being a calibration-testing tool.On the basis of the requirements of the company’s administration and needs of designing the concentrated reflectors the operation conditions for the Sun-Walker were formulated. As the first step, the complex design of the whole system was made and division on the parts was specified. After the preliminary conducted simulation of the functions and operation conditions of the all parts were formulated.As the next steps, the detailed design of all the parts was made. Most components were ordered from respective companies. Some of the mechanical components were made in the workshop of the company. All parts of the Sun-Walker were assembled and tested. The software part, which controls the Sun-Walker work and conducts measurements of solar irradiation, was created on the LabVIEW basis. To tune and test the software part, the special simulator was designed and assembled.When all parts were assembled in the complete system, the Sun-Walker was tested, calibrated and tuned.
Resumo:
The aim of this study is to evaluate the variation of solar radiation data between different data sources that will be free and available at the Solar Energy Research Center (SERC). The comparison between data sources will be carried out for two locations: Stockholm, Sweden and Athens, Greece. For the desired locations, data is gathered for different tilt angles: 0°, 30°, 45°, 60° facing south. The full dataset is available in two excel files: “Stockholm annual irradiation” and “Athens annual irradiation”. The World Radiation Data Center (WRDC) is defined as a reference for the comparison with other dtaasets, because it has the highest time span recorded for Stockholm (1964–2010) and Athens (1964–1986), in form of average monthly irradiation, expressed in kWh/m2. The indicator defined for the data comparison is the estimated standard deviation. The mean biased error (MBE) and the root mean square error (RMSE) were also used as statistical indicators for the horizontal solar irradiation data. The variation in solar irradiation data is categorized in two categories: natural or inter-annual variability, due to different data sources and lastly due to different calculation models. The inter-annual variation for Stockholm is 140.4kWh/m2 or 14.4% and 124.3kWh/m2 or 8.0% for Athens. The estimated deviation for horizontal solar irradiation is 3.7% for Stockholm and 4.4% Athens. This estimated deviation is respectively equal to 4.5% and 3.6% for Stockholm and Athens at 30° tilt, 5.2% and 4.5% at 45° tilt, 5.9% and 7.0% at 60°. NASA’s SSE, SAM and RETScreen (respectively Satel-light) exhibited the highest deviation from WRDC’s data for Stockholm (respectively Athens). The essential source for variation is notably the difference in horizontal solar irradiation. The variation increases by 1-2% per degree of tilt, using different calculation models, as used in PVSYST and Meteonorm. The location and altitude of the data source did not directly influence the variation with the WRDC data. Further examination is suggested in order to improve the methodology of selecting the location; Examining the functional dependence of ground reflected radiation with ambient temperature; variation of ambient temperature and its impact on different solar energy systems; Im pact of variation in solar irradiation and ambient temperature on system output.
Resumo:
The demand for cooling and air-conditioning of building is increasingly ever growing. This increase is mostly due to population and economic growth in developing countries, and also desire for a higher quality of thermal comfort. Increase in the use of conventional cooling systems results in larger carbon footprint and more greenhouse gases considering their higher electricity consumption, and it occasionally creates peaks in electricity demand from power supply grid. Solar energy as a renewable energy source is an alternative to drive the cooling machines since the cooling load is generally high when solar radiation is high. This thesis examines the performance of PV/T solar collector manufactured by Solarus company in a solar cooling system for an office building in Dubai, New Delhi, Los Angeles and Cape Town. The study is carried out by analyzing climate data and the requirements for thermal comfort in office buildings. Cooling systems strongly depend on weather conditions and local climate. Cooling load of buildings depend on many parameters such as ambient temperature, indoor comfort temperature, solar gain to the building and internal gains including; number of occupant and electrical devices. The simulations were carried out by selecting a suitable thermally driven chiller and modeling it with PV/T solar collector in Polysun software. Fractional primary energy saving and solar fraction were introduced as key figures of the project to evaluate the performance of cooling system. Several parametric studies and simulations were determined according to PV/T aperture area and hot water storage tank volume. The fractional primary energy saving analysis revealed that thermally driven chillers, particularly adsorption chillers are not suitable to be utilizing in small size of solar cooling systems in hot and tropic climates such as Dubai and New Delhi. Adsorption chillers require more thermal energy to meet the cooling load in hot and dry climates. The adsorption chillers operate in their full capacity and in higher coefficient of performance when they run in a moderate climate since they can properly reject the exhaust heat. The simulation results also indicated that PV/T solar collector have higher efficiency in warmer climates, however it requires a larger size of PV/T collectors to supply the thermally driven chillers for providing cooling in hot climates. Therefore using an electrical chiller as backup gives much better results in terms of primary energy savings, since PV/T electrical production also can be used for backup electrical chiller in a net metering mechanism.
Resumo:
Exploiting solar energy technology for both heating and cooling purposes has the potential of meeting an appreciable portion of the energy demand in buildings throughout the year. By developing an integrated, multi-purpose solar energy system, that can operate all twelve months of the year, a high utilisation factor can be achieved which translates to more economical systems. However, there are still some techno-economic barriers to the general commercialisation and market penetration of such technologies. These are associated with high system and installation costs, significant system complexity, and lack of knowledge of system implementation and expected performance. A sorption heat pump module that can be integrated directly into a solar thermal collector has thus been developed in order to tackle the aforementioned market barriers. This has been designed for the development of cost-effective pre-engineered solar energy system kits that can provide both heating and cooling. This thesis summarises the characterisation studies of the operation of individual sorption modules, sorption module integrated solar collectors and a full solar heating and cooling system employing sorption module integrated collectors. Key performance indicators for the individual sorption modules showed cooling delivery for 6 hours at an average power of 40 W and a temperature lift of 21°C. Upon integration of the sorption modules into a solar collector, measured solar radiation energy to cooling energy conversion efficiencies (solar cooling COP) were between 0.10 and 0.25 with average cooling powers between 90 and 200 W/m2 collector aperture area. Further investigations of the sorption module integrated collectors implementation in a full solar heating and cooling system yielded electrical cooling COP ranging from 1.7 to 12.6 with an average of 10.6 for the test period. Additionally, simulations were performed to determine system energy and cost saving potential for various system sizes over a full year of operation for a 140 m2 single-family dwelling located in Madrid, Spain. Simulations yielded an annual solar fraction of 42% and potential cost savings of €386 per annum for a solar heating and cooling installation employing 20m2 of sorption integrated collectors.
Resumo:
Neste trabalho foi calculada teoricamente a radiação solar direta normal para Porto Alegre e vizinhanças. Para tal fim foi feito um levantamento da insolação horária em Porto Alegre, entre os anos de 1968 a 1982 e, a partir destes como não se dispunha de dados experimentais, calculou-se a radiação solar global efetiva, com o auxílio de uma expressão do tipo Angstrom. A posse destes dados permitiu calcular a radiação direta normal, que se apresenta em forma de tabelas e gráficas. Como um resultado adicional, calculou-se a percentagem de dias aproveitáveis ou não para distintas hipóteses de uso da Energia Solar. Com o intuito de comprovar a validade dos cálculos desenvolvidos, compararam-se os dados de radiação difusa, calculados a partir dos de direta normal, com os obtidos por outras teorias.
Desenvolvimento de um programa de simulação computacional de sistemas de aquecimento solar para água
Resumo:
Esta Tese apresenta uma análise do comportamento térmico de um sistema de aquecimento solar operando por termossifão. Neste tipo de sistema o fluido no coletor solar é circulado por convecção natural, que acontece devido à diferença de massa específica da água ao longo circuito. Nestes sistemas a vazão mássica varia ao longo do dia e do ano, dependendo, dentre outros fatores, da irradiância solar absorvida, do perfil de temperaturas da água no sistema, da geometria, do volume e do perfil de demanda de água quente. Para uma avaliação detalhada do comportamento térmico de aquecedores solares operando por termossifão foram realizados ensaios experimentais e cálculos teóricos. Os resultados dos experimentos concordaram com aqueles apresentados na literatura e sua análise fundamentou o desenvolvimento do aplicativo TermoSim, um programa de simulação computacional do comportamento térmico de sistemas de aquecimento de água com energia solar. O tratamento matemático adotado no TermoSim compreende a modelagem dos coletores solares de acordo com a teoria de Hottel-Bliss-Whillier. O reservatório térmico é modelado com estratificação térmica, convecção e condução entre as camadas. A vazão mássica é obtida a partir do balanço da quantidade de movimento no circuito. Os modelos matemáticos empregados na construção do aplicativo TermoSim foram validados através do confronto dos resultados simulados com medidas experimentais. Foi demonstrado que a utilização destes modelos é adequada e permite reproduzir com precisão o comportamento térmico dos coletores solares e do reservatório térmico. Além do programa TermoSim, foi também desenvolvido o programa TermoDim, que é uma ferramenta para o dimensionamento de sistemas de aquecimento solar, que requer apenas o conhecimento dos parâmetros geométricos do sistema, dados meteorológicos em média mensal e informação a respeito do volume de demanda. O TermoDim é apropriado para estimar o desempenho de aquecedores solares operando por termossifão com tanques verticais e horizontais. O método de dimensionamento do TermoDim é baseado na correlação para a eficiência média mensal obtida neste trabalho a partir de um grande número de simulações.
Resumo:
MACHADO, Antônio V. et al. Estudio del Secado de Anacardo (Anacardium occidentale L.) mediante Secador Solar de Radiación Directa. Información Tecnológica, v. 21, n. 1, p. 31-37, 2010.
Resumo:
The amount of solar energy made available for the production of a sabid seed varied as a function of the time of the year, the face of the plant in which, the position in the plant on which and the position in the pod in which it was produced.Variation in solar energy availability as a consequence of the time of the year was a direct consequence of latitude. At 21degrees5'22 S the highest amounts of Global Solar Radiation (GSR) reaching the site where the experiment was conducted took place during the months from November through February. During these months there were no marked differences between any two of the amounts of GSR reaching faces North (N), South (S), West (W) East (E). From February through November (period during which the sabid plants of this study flowered and the resulting seeds matured and were harvested) the total GSR's were the lowest and marked differences were found between faces N and S, with face N receiving much more GSR than face S. During that period, faces W and E received practically the same amount of GSR and it was much less than that received by face N and much more than the one received by face S.The amount of biological energy made available for the development of a seed seemed also to vary according to a dry matter partitioning strategy by the plant -the central third of the plant seemed to be the one receiving the highest amounts of energy, followed either by the upper or the lower third of the plant- it was not very clear which third of the plant immediately followed the central one. The partitioning of biological energy at the pod level also seemed to follow a strategy by which the central seeds would be the ones to receive more, followed by the proximal seeds and these by the distal ones.This availability of energy seemed to have a direct effect on seed size, weight and on the percentage of seeds which showed a degree of dormancy deep enough to prevent their germinating under the conditions of a standard germination test.The implications of these results for the improvement of methods for the overcoming of dormancy of sabia seeds are discussed.
Resumo:
Com este trabalho, o objetivo foi estimar a radiação fotossinteticamente ativa (PAR) e correlacioná-la com a massa de matéria seca (MMSPA) da grama-esmeralda (Zoysia japonica Steud.), em superfícies com diferentes exposições e declividades. A pesquisa foi desenvolvida na Bacia Hidrográfica Experimental do Departamento de Engenharia Rural, FCAV/UNESP, Brasil, onde foram utilizadas as superfícies (H; 10 N; 30 N; 50 N; 10 S; 30 S; 50 S; 10 L; 30 L; 50 L; 10 O; 30 O e 50 O). Para a obtenção da radiação solar global, foi instalada uma estação meteorológica automatizada, onde a PAR (variável dependente) foi obtida por meio da equação y = a + bx, e a radiação global foi a independente. Para comparação de médias da MMSPA, utilizou-se o teste de Tukey, a 5% de probabilidade, e para verificar a relação existente PAR/MMSPA, o coeficiente de correlação linear simples. O resultado mostrou que o acúmulo desses efeitos na PAR aumenta com a exposição norte e decresce com a sul, sendo a exposição 50 N a mais indicada para taludes, não havendo correlação entre a PAR e a MMSPA para as superfícies avaliadas para o período estudado.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Avaliou-se a evolução anual das componentes global, direta e difusa da radiação solar incidente em superfícies inclinadas a 12,85; 22,85 e 32,85º, com face voltada ao Norte, em Botucatu-SP. Foram obtidas frações radiométricas para cada componente da radiação nas superfícies supracitadas, através de razões com a radiação global e a do topo da atmosfera. A sazonalidade foi avaliada através das médias mensais dos valores diários. As medidas ocorreram entre 04/1998 e 07/2001, em 22,85º; 08/2001 e 02/2003, em 12,85º; e de 03/2003 a 12/2007, em 32,85º, com medidas concomitantes no plano horizontal (referência). Os níveis das radiações global e direta nos planos inclinados foram inferiores no período de verão e superiores entre os equinócios, quando comparadas ao plano horizontal. A radiação difusa nas superfícies inclinadas foi inferior na maioria dos meses, com perdas de até 65%. Ocorreu uma tendência de aumento das diferenças entre as superfícies horizontal e inclinada com o incremento do ângulo em todas as componentes e frações da radiação incidente. A evolução anual das precipitações pluviométricas e da razão de nebulosidade afetou diretamente a transmissividade atmosférica das componentes direta e difusa na região.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)