958 resultados para Six-min walk test


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Consistently with a priori predictions, school retention (repeating a year in school) had largely positive effects for a diverse range of 10 outcomes (e.g., math self-concept, self-efficacy, anxiety, relations with teachers, parents and peers, school grades, and standardized achievement test scores). The design, based on a large, representative sample of German students (N = 1,325, M age = 11.75 years) measured each year during the first five years of secondary school, was particularly strong. It featured four independent retention groups (different groups of students, each repeating one of the four first years of secondary school, total N = 103), with multiple post-test waves to evaluate short- and long-term effects, controlling for covariates (gender, age, SES, primary school grades, IQ) and one or more sets of 10 outcomes realised prior to retention. Tests of developmental invariance demonstrated that the effects of retention (controlling for covariates and pre-retention outcomes) were highly consistent across this potentially volatile early-to-middle adolescent period; largely positive effects in the first year following retention were maintained in subsequent school years following retention. Particularly considering that these results are contrary to at least some of the accepted wisdom about school retention, the findings have important implications for educational researchers, policymakers and parents.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

One of the best examinations used routinely to detect gastro-oesophageal reflux (GOR) is scintigraphy and attempts are continuously being made to improve the performance of the test. We have tested a new manoeuvre to improve the results. Three hundred and twenty eight patients (190 males and 138 females, aged 1 month to 84 years, average 4.47 years) were studied after a 12 h fast period with 100 MBq of Tc-99(m)-Phytate, 50 ml volume, directly delivered into the stomach in a mixture of orange juice. All patients were strongly suspected of having GOR. Conventional acquisition was done for 20 min, at a rate of one frame every 20 s. in the middle of the examination, small children were put in the upright position and held there for a few seconds or released in a way that allowed movement; adults were asked to stand up and walk a few metres. The test was then continued for the remaining 10 min. The global index of positivity was 64.6% (76 positive cases in the first half of the examination and 134 positive cases only after the manoeuvre). The mean of GOR episodes observed in the positive cases without the manoeuvre was 0.5 per patient, significantly different from the mean of 1.59 noted after the manoeuvre (P<0.01). In 28 cases the manoeuvre increased either the intensity or the frequency of reflux previously detected without it. We believe that this manoeuvre should be performed in all scintigraphic tests aiming to detect GOR. In the present series, the manoeuvre increased the frequency of GOR episodes. ((C) 2001 Lippincott Williams & Wilkins)].

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: This study evaluated the effect of cutting initiation location and cutting speed on the bond strength between resin cement and feldspathic ceramic.Materials and Methods: Thirty-six blocks (6.4 x 6.4 x 4.8 mm) of ceramic (Vita VM7) were produced. The ceramic surfaces were etched with 10% hydrofluoric acid gel for 60 s and then silanized. Each ceramic block was placed in a silicon mold with the treated surface exposed. A resin cement (Variolink II) was injected into the mold over the treated surface and polymerized. The resin cement-ceramic blocks were divided into two groups according to experimental conditions: a) cutting initiation location - resin cement, ceramic and interface; and b) cutting speed - 10,000, 15,000, and 20,000 rpm. The blocks were sectioned to achieve non-trimmed bar specimens. The microtensile test was performed in a universal testing machine (1 mm/min). The failure modes were examined using an optical light microscope and SEM. Bond strength results were analyzed using one-way ANOVA and Tukey's test (alpha = 0.05).Results: Significant influences of cutting speed and initiation location on bond strength (p < 0.05) were observed. The highest mean was achieved for specimens cut at 15,000 rpm at the interface (15.12 +/- 5.36 MPa). The lowest means were obtained for specimens cut at the highest cutting speed in resin cement (8.50 +/- 3.27 MPa), and cut at the lowest cutting speed in ceramic (8.60 +/- 2.65MPa). All groups showed mainly mixed failure (75% to 100%).Conclusion: The cutting speed and initiation location are important factors that should be considered during specimen preparation for microtensile bond strength testing, as both may influence the bond strength results.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to investigate the possible influence of different levels of aerobic fitness (VO2MAX) on the parameters of the running anaerobic sprint test (RAST). Thirty-eight subjects (Age = 18.1 ± 2.5 years, Height = 173 ± 1 cm and Body mass = 65.1 ± 6.5 kg) were classified into two groups, low and high aerobic fitness (LAF: n = 22 and HAF: n = 16). The VO2MAX was determined by an incremental exercise performed until exhaustion. The RAST was composed of six maximal efforts of 35m separated by 10s passive recovery. The VO2MAX was significantly different between groups (LAF = 51.7 ± 1.9 mL.kg -1.min-1; HAF = 58.6 ± 3.1 mL.kg -1.min-1). The mean power (MP) was significantly higher in the LAF (552.7 ± 132.1 W) in relation to the HAF group (463.6 ± 132.8 W). The impulse (ImP) was significantly correlated with the VO 2MAX in HAF. It can be concluded that there is an indication that the aerobic metabolism exerts an influence on the completion of RAST.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives: To investigate the test-retest reliability of mechanical parameters derived from a 3-min isokinetic all-out test, performed at 60 and 100 rpm. Reliability and validity of the peak oxygen uptake derived from 3-min isokinetic all-out test were also tested. Design: 14 healthy male subjects completed an incremental ramp testing and four randomized 3-min isokinetic all-out test (two at 60 rpm and two at 100 rpm). Methods: The absolute and relative reliability of the following parameters were analyzed: peak power, mean power, end power, fatigue index, work performed above end power and peak oxygen uptake. Results: No difference was found between each two sets of data, although there were between-cadence differences for peak power, mean power, end power, and fatigue index. Higher intra-class correlation (ICC) and lower coefficient of variation (CV) were found for end power (ICC = 0.91 and 0.95; CV = 5.6 and 5.7%) and mean power (ICC = 0.97 and 0.98; CV = 2.4 and 3.1%), than for peak power (ICC = 0.81 and 0.84; CV = 8.7 and 10%) and work performed above end power (ICC = 0.79 and 0.84; CV = 7.9 and 10.6%; values reported for 60 rpm and 100 rpm, respectively). High reliability scores were also observed for peak oxygen uptake at both cadences (60 rpm, CV = 3.2%; 100 rpm, CV = 2.3%,) with no difference with the incremental ramp testing peak oxygen uptake. Conclusions: The power profile and peak oxygen uptake of a 3-min isokinetic all-out test are both highly reliable, whether the test is performed at 60 or 100 rpm. Besides, peak oxygen uptake and work performed above end power were not affected by the change in cadence while peak power, mean power, end power, and fatigue index were. © 2013.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives. To verify the hypothesis that crack analysis and a mechanical test would rank a series of composites in a similar order with respect to polymerization stress. Also, both tests would show similar relationships between stress and composite elastic modulus and/or shrinkage. Methods. Soda-lime glass discs (2-mm thick) with a central perforation (3.5-mm diameter) received four Vickers indentations 500 mu m from the cavity margin. The indent cracks were measured (500x) prior and 10 min after the cavity was restored with one of six materials (Kalore/KL, Gradia/GR, Ice/IC, Wave/WV, Majesty Flow/MF, and Majesty Posterior/MP). Stresses at the indent site were calculated based on glass fracture toughness and increase in crack length. Stress at the bonded interface was calculated using the equation for an internally pressurized cylinder. The mechanical test used a universal testing machine and glass rods (5-mm diameter) as substrate. An extensometer monitored specimen height (2 mm). Nominal stress was calculated dividing the maximum shrinkage force by the specimen cross-sectional area. Composite elastic modulus was determined by nanoindentation and post-gel shrinkage was measured using strain gages. Data were subjected to one-way ANOVA/Tukey or Kruskal-Wallis/Mann-Whitney tests (alpha: 5%). Results. Both tests grouped the composites in three statistical subsets, with small differences in overlapping between the intermediate subset (MF, WV) and the highest (MP, IC) or the lowest stress materials (KL, GR). Higher stresses were developed by composites with high modulus and/or high shrinkage. Significance. Crack analysis demonstrated to be as effective as the mechanical test to rank composites regarding polymerization stress. (c) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.