1000 resultados para Separação sólido-líquido


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a methodology to separate and identify polar compounds as flavonoid and lignan glucosides, amino acids, salt of quaternary ammonium amino acid and carbohydrates from branches of Porcelia macrocarpa (Annonaceae).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chalcone and its fluorinated derivatives were synthesized and photolyzed in the solid state. UV irradiation of chalcone and its monosubstituted fluorine derivatives (3- and 4-fluorchalcone) resulted in a mixture of anti-head-head (gamma-truxinic), sin-head-tail (alpha-truxilic) and anti-head-tail (epsilon-truxilic) dimers. On the other hand, upon irradiation of 3,4- and 3,5-difluorchalcone a stereoselective formation of the alpha-truxilic photodimer was observed, whereas for 2-substituted chalcones (2,3difluorchalcone, 2,5-difluorchalcone, 2,6-difluorchalcone and 2,3,4-trifluorchalcone) the beta-truxilic dimer was stereoselectively obtained. 2',3',4',5',6'-pentafluorchalcone was the less reactive of all chalcones studied and at least one of the possible photodimers, i.e the anti-head-head isomer, was identified. Irradiation of polyfluorinated chalcones such as 2,3,5,6-tetrafluor-, 2,3,4,5,6-pentafluor-, and 2,2',3,3',4,4',5,5',6,6'-decafluorchalcone led only to polymerization and/or decomposition products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the Brazilian Complete Spacial Mission, the research of Vehicle Satellite Launcher is important. The solid propellant composite used in this vehicle is made with ammonium perchlorate, aluminiun powder and hydroxy terminated polibutadiene resin. In the propellant the bonding agent has a function to promote the interaction between solids and polimeric matrix, improving mechanical properties as stress, strain, aging characteristics and moisture embrittlement. Due its importance in propellant, bonding agent is consider as industrial secret and the literature about it is generic, without greater informations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reaction between hydroxy-terminated polybutadiene and isophorone diisocyanate constitutes the base of the curing process of the most composite solid propellant used in the propulsion of solid rocket propellant. In this work, differential scanning calorimetry and viscosity measurements were used to evaluate the effect of the ferric acetylacetonate catalyst concentration on the reaction between HTBR and IPDI. These analyses show one exotherm, which shifts to lower temperatures as the catalyst concentration increases. The viscosity analyses show that the increase of temperature causes, at first, a reduction in the mixture viscosity, reaching a minimum range called gelification region (increasing the crosslinking density).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes an experimental design technique, known as variables search, developed to expose the critical variables and screen out the irrelevant ones. It is easy to learn and use and clearly dissociates the main and interactions effects from each other. An example of air separation process by pressure swing adsorption was used to demonstrate how the variables search technique works. The phases of identification of the critical variables is shown, step by step,.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to propose two different didactic experiments, which can be used in practical classes of analytical chemistry courses. More flexible experiments related to the theme, giving some options to the instructor are proposed. In this way, the Experiment 1 was divided in two parts. In the first one, the visualization of two distinct phases separation is emphasized: the rich and the poor phases in surfactant. In the second part, the metal pre-concentration (Co as example) is emphasized. The Experiment 2 has three different parts. In the first one, the complex formation is pointed out, in the second one, the pH influence is shown and in the last one, the influence of the complexation time is demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for determination of lead and cadmium in aqueous samples using solvent microextraction and dithizone as complexing agent with FAAS was developed. Solvent microextraction parameters were optimized. The effect of foreign ions on the extraction yields was studied. The extraction was carried out until the aqueous to organic phase ratio achieved a 250 fold preconcentration of metals. For preconcentration times of 4 min the 3sigma detection limits, relative standard deviations (n=7) and linear calibration ranges were 1.6 mug L-1, 5.8% and 10.0 -- 80.0 mug L-1 for lead and 11.1 ng L-1, 5.9% and 0.3 -- 3.0 mug L-1 for cadmium, respectively. The solvent microextraction procedure presented here was applied to the determination of lead and cadmium in natural waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to explore the possibility of the application of a non-ionic resin obtained by impregnation of Alizarin Red S (VAS) in Amberlite XAD-7 for manganese, copper and zinc separation and preconcentration in saline matrices. For these system, the metals were quantitatively retained, in the pH range 8.5-10.0, by using 0.50 g of solid phase, stirring time of five minutes and a total mass up to 200 mug of each cation. The sorbed elements were subsequently eluted and a fifty-fold, ten-fold and ten-fold preconcentration factor for to Zn, Cu and Mn were obtained, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research was developed by considering that the solid waste produced in the process of pig iron production represents the loss of raw materials and the increase in environmental problem. The charcoal based mini blast-furnace off gases dust named CHARCOK was collected from SIDERPA ¾ Siderúrgica Paulino Ltda, located in Sete Lagoas, Minas Gerais. The Charcok was characterized and classified according to ABNT (Associação Brasileira de Normas Técnicas) standard. The results showed that the Charcok should be classified as Class I Wastes ¾ "Hazard Wastes" because of its high concentration of phenols (54.5mg C6H5OH/kg). The Charcok had high concentration of iron and charcoal which can be used as energy source.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This note has as objective to present the advantages of the use of syringe-type pumps for the feeding of liquid reactants, together with mass flow controllers for gases, instead of the saturators, as it is generally accomplished. Among the advantages, the system with syringe pumps presents a greater flexibility in flow control as well as in composition compared with the system that uses saturator. In addition, the flow of the liquid reactants is known with precision in the syringe pump system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article gives an overview of polymer materials used for lead separation and preconcentration. Different kinds of polymer resins, commercial or not, are cited as well as the most used functional groups attached to polymer backbones. The synthesis of these resins and conditions of lead adsorption and elution are remarked. The influence of the porous structure of the polymer on the resines performance is described as well as the use of spacer arms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the separation of CO2 from a gas mixture containing 25% CO2, 4% O2 and 71% N2 using the pressure swing adsorption (PSA) technique. The adsorbent selected was the zeolite 13X due to its great adsorption capacity for CO2 and selectivity towards the other components of the gas mixture. The experimental technique was designed to identify the most important variables for the process and to optimize it. It is shown that the PSA technique can be used to separate CO2 from O2 and N2 to obtain an effluent containing 2% CO2 with 99% separation efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analysis of diazepam (DZP) and its active metabolite nordiazepam (NDZP) in plasma is commonly performed in clinical medicine to ensure proper therapeutic effects while minimizing the incidence of toxicity. This study aimed to optimize analytical parameters and compare two pre-treatment techniques, liquid-liquid (LLE) and solid phase extraction (SPE), as well as liquid chromatographic conditions to analyze simultaneously DZP and NDZP in plasma from 20 patients treated with a daily dose of 10 mg. Both techniques showed to be well in line with the international criteria for analytical validation, which permitted to quantify DZP (66.2 - 1148.6 ng mL-1) and NDZP (138.5 - 808.6 ng mL -1) in all samples. The correlation coefficients between SPE and LLE were respectively 0.9729 for DZP and 0.9643 for NDZP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MIPs are synthetic polymers that are used as biomimetic materials simulating the mechanism verified in natural entities such as antibodies and enzymes. Although MIPs have been successfully used as an outstanding tool for enhancing the selectivity or different analytical approaches, such as separation science and electrochemical and optical sensors, several parameters must be optimized during their synthesis. Therefore, the state-of-the-art of MIP production as well as the different polymerization methods are discussed. The potential selectivity of MIPs in the extraction and separation techniques focusing mainly on environmental, clinical and pharmaceutical samples as applications for analytical purposes is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a systematic study for bovine liver sample preparation for Cd and Pb determination by solid sampling electrothermal atomic absorption spectrometry. Samples were prepared using different procedures: (1) drying in a household microwave oven followed by drying in a stove at 60 ºC until constant mass, and (2) freeze-drying. Ball and cryogenic mills were used for grinding. Particle size, sample size and micro sample homogeneity were investigated. All prepared samples showed good homogeneity (He < 10) even for low sample mass, but samples dried in a microwave oven/stove and ground in a ball mill presented the best homogeneity.