983 resultados para Scanline sampling technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a methodology to obtain thin films of cucurbit[6]uril, starting from ammoniacal solutions. This technique is very useful for the obtention of modified electrodes or other substrates for sensor purposes. Cucurbit[6]uril is insoluble in most media, and film formation was impossible until now.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The image reconstruction using the EIT (Electrical Impedance Tomography) technique is a nonlinear and ill-posed inverse problem which demands a powerful direct or iterative method. A typical approach for solving the problem is to minimize an error functional using an iterative method. In this case, an initial solution close enough to the global minimum is mandatory to ensure the convergence to the correct minimum in an appropriate time interval. The aim of this paper is to present a new, simple and low cost technique (quadrant-searching) to reduce the search space and consequently to obtain an initial solution of the inverse problem of EIT. This technique calculates the error functional for four different contrast distributions placing a large prospective inclusion in the four quadrants of the domain. Comparing the four values of the error functional it is possible to get conclusions about the internal electric contrast. For this purpose, initially we performed tests to assess the accuracy of the BEM (Boundary Element Method) when applied to the direct problem of the EIT and to verify the behavior of error functional surface in the search space. Finally, numerical tests have been performed to verify the new technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To describe a new suture technique for laryngeal microsurgery and to test its applicability in human cadaver larynges. The new technique was experimentally tested in freshly excised human larynges fixed to a larynx holder appropriate for the simulation of laryngeal microsurgery. A mucosal flap was created in the vocal fold for the fabrication of a pocket for subepithelial fat implantation, and the wound edges were then brought together and sutured using the proposed technique. The time necessary for suture was measured with a stopwatch for five successive sutures performed by one of the surgeons. The presence or absence of mucosal rupture was determined for five sutures performed by two surgeons, for a total of 10 sutures. The sutures were performed without the help of an assistant, with no laceration of the mucosa being observed in any of the attempts, and within a relatively short period of time even without previous training. The sutures performed permitted the implanted fat to remain stable under the mucosal flap. Conclusions: the new suture technique is an easy procedure, which can be performed by a single surgeon under microscopic vision, with a low risk of tissue rupture. The technique does not markedly prolong the duration of surgery and a single suture thread can be used for the fabrication of more than one stitch.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inhaled endotoxin (lipopolysaccharide, LPS) initiates an inflammatory response and leads to the expression of CR3 (CD11b/CD18) receptors on polymorphonuclear leukocytes (PMNs). We determined if PMN activation in nasal lavage fluid (NLF) is a possible biomarker of occupational endotoxin exposure. Seven subjects exposed to endotoxin provided NLF samples that were split into three aliquots (negative control - 1 M nicotinamide; sham; positive control - 11 eta g of exogenous LPS) and PMN activation was measured using a chemiluminometer. Differences in mean PMN activation were apparent, negative control: 548 +/- 15.65 RLU 100 mu l(-1); sham: 11469 +/- 2582 RLU 100 mu l(-1); positive control: 42026 +/- 16659 RLU 100 mu l (n = 7; p < 0.05). This technique shows promise as a diagnostic method for measuring upper airway LPS exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Hypoglossal-facial neurorrhaphy has been widely used for reanimation of paralyzed facial muscles after irreversible proximal injury of the facial nerve. However, complete section of the hypoglossal nerve occasionally results in hemiglossal dysfunction and interferes with swallowing and speech. To reduce this morbidity, a modified technique with partial section of the hypoglossal nerve after mastoid dissection of the facial nerve (HFM) has been used. We report our experience with the HFM technique, retrospectively comparing the outcome with results of the classic hypoglossal-facial neurorrhaphy. METHODS: A retrospective review was performed in 36 patients who underwent hypoglossal-facial neurorrhaphy with the classic (n = 12) or variant technique (n = 24) between 2000 and 2006. Facial Outcome was evaluated with the House-Brackmann grading system, and tongue function was evaluated with a new scale proposed to quantify Postoperative tongue alteration. The results were compared, and age and time between nerve injury and surgery were correlated with the outcome. RESULTS: There was no significant difference between the two techniques concerning facial reanimation. A worse outcome of tongue function, however, was associated with the classic technique (Mann-Whitney U test; P < 0.05). When HFM was used, significant correlations defined by the Spearman test were identified between preoperative delay (p = 0.59; P = 0.002) or age (p = 0.42; P = 0.031) and results of facial reanimation evaluated with the House-Brackmann grading system. CONCLUSION: HFM is as effective as classic hypoglossal-facial neurorrhaphy for facial reanimation, and it has a much lower morbidity related to tongue function. Better results are obtained in younger patients and with a shorter interval between facial nerve injury and surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to determine the impact of endovascular surgery versus open vascular technique training in a Brazilian teaching service. DESIGN: Cross-sectional study. SETTING: Hospital das Clinicas-Faculty of Medicine University of Sao Paulo, a tertiary institutional hospital Brazil. PARTICIPANTS: We reviewed 1,040 arterial operations performed during 2 distinct time periods: January 1995 to December 1996, and January 2006 to December 2007. Based on the disease treated, the procedures were classified into the following 5 groups: abdominal aortic aneurysms (AAA), aorto-iliac obstructive disease (Al), obstructive disease of the femoropoplitealtibial segment (FP), carotid disease (C), and others (0). The operations were also divided into an endovascular surgery (ES) group and an open surgery (OS) group. We compared the number of open and endovascular procedures for each arterial disease group during both periods. RESULTS: During the 2006-2007 period, 654 patients were treated surgically, whereas over the 1995-1996 period, 386 arterial operations were performed. A. significant increase in endovascular procedures (p < 0.001) was found from the 1995-1996 period to the 2006-201)7 period (35 vs 351, respectively) in all groups, whereas open surgery showed a slight increase in the number of procedures in the AAA and 0 groups only. In the 1995-1996 period, OS was the primary surgical method for all groups, but in the 2006-2007 time frame, OS was performed more frequently than ES only in the AAA and 0 groups. Considering all vascular disease groups, OS was the technique used in 90.9% (351 of 386) of the operations during 1995-1996, whereas in 2006-2007, OS was performed in only 46.3% (303 of 654) of the procedures. CONCLUSIONS: The increase in the number of ES observed over the past decade has had little impact on OS procedures performed at our medical center, not bringing harm to open surgical training. (J Surg 68:19-23. (C) 2011 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To understand the dynamic mechanisms of the mechanical milling process in a vibratory mill, it is necessary to determine the characteristics of the impact forces associated with the collision events. However, it is difficult to directly measure the impact force in an operating mill. This paper describes an inverse technique for the prediction of impact forces from acceleration measurements on a vibratory ball mill. The characteristics of the vibratory mill have been investigated by the modal testing technique, and its system modes have been identified. In the modelling of the system vibration response to the impact forces, two modal equations have been used to describe the modal responses. The superposition of the modal responses gives rise to the total response of the system. A method based on an optimisation approach has been developed to predict the impact forces by minimising the difference between the measured acceleration of the vibratory ball mill and the predicted acceleration from the solution of the modal equations. The predicted and measured impact forces are in good agreement. Copyright (C) 1996 Elsevier Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reconstruction of the nipple-areola complex (NAC) is the last stage of breast reconstruction and represents the search for symmetry in regard to the contralateral breast. The objective of this study was to present an areola reconstruction technique with local skin graft to improve the texture and aspect of the reconstructed areola, searching for a natural look. This technique was performed on 122 patients who in the period from January 2000 to December 2005 were submitted to nipple and areola reconstruction. Once the position of the new nipple was determined, markings were made for the reconstruction of the areola. Then the external limit of the new areola was incised and the skin was centripetally deepidermized up to 85% of its diameter. After this procedure the detached skin was repositioned in its bed as a graft and sutured with 4.0 mononylon thread. Incisions with an 11-blade scalpel were then made in V and C forms associated with the detachment of this skin of the receptor area along the local graft so that at the end of the healing process they would determine alterations in the areolar texture mimicking the texture of a normal areola. All patients underwent tattooing 3 months after reconstruction of the NAC taking into account the different shades of the contralateral areola and nipple colors. The use of a local skin graft associated with C and V incisions allowed alteration in the texture of the reconstructed areola. The use of different ink shades for tattooing helped to give a tridimensional aspect to this areola. These factors determined a good aesthetic result in these patients. This areola reconstruction using a local skin graft allows change in the areola texture and a tridimensional aspect similar to that of a normal areola without the inconvenience of grafting from a distance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thirty-one patients with unilateral long-standing facial palsy underwent I-stage reanimation with free gracilis muscle transplant innervated by the masseteric branch of the trigeminal nerve. They were divided into 2 nonrandomized groups according to insertion technique: group 1 (9 patients), interrupted suture between the free flap and the orbicularis oris of the upper and lower lip on the paralyzed side; group It (22 patients), palmaris longus tendon graft placed between the gracilis free flap and the orbicularis oris of the upper and lower lip on the nonparalyzed side. Qualitative evaluation of the smile demonstrated better results in patients from group II. Comparing the position Of the Cupid`s bow at rest, pre- and postoperatively in each patient, we observed significant improvement of facial symmetry in both groups. During smile, however, there was a significantly higher rate of centralization of the Cupid`s bow in patients submitted to reanimation with the use of the palmaris longus tendon (group II).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A robust semi-implicit central partial difference algorithm for the numerical solution of coupled stochastic parabolic partial differential equations (PDEs) is described. This can be used for calculating correlation functions of systems of interacting stochastic fields. Such field equations can arise in the description of Hamiltonian and open systems in the physics of nonlinear processes, and may include multiplicative noise sources. The algorithm can be used for studying the properties of nonlinear quantum or classical field theories. The general approach is outlined and applied to a specific example, namely the quantum statistical fluctuations of ultra-short optical pulses in chi((2)) parametric waveguides. This example uses a non-diagonal coherent state representation, and correctly predicts the sub-shot noise level spectral fluctuations observed in homodyne detection measurements. It is expected that the methods used wilt be applicable for higher-order correlation functions and other physical problems as well. A stochastic differencing technique for reducing sampling errors is also introduced. This involves solving nonlinear stochastic parabolic PDEs in combination with a reference process, which uses the Wigner representation in the example presented here. A computer implementation on MIMD parallel architectures is discussed. (C) 1997 Academic Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Advantages of the bicaval versus the biatrial technique have been reported, emphasizing atrial electrical stability and less tricuspid regurgitation. Objective. To analyze the impact of the surgical technique on long-term pulmonary pressures, contractility, and graft valvular behavior after heart transplantation. Methods. Among 400 orthotopic heart transplantation recipients from 1985 to 2010, we selected 30 consecutive patients who had survived beyond 3 years. The biatrial versus bicaval surgical technique groups included 15 patients each. Their preoperative clinical characteristics were similar. None of the patients displayed a pulmonary vascular resistance or pulmonary artery pressure over 6U Wood or 60 mm Hg, respectively. We evaluated invasive hemodynamic parameters during routine endomyocardial biopsies. Two-dimensional echocardiographic parameters were obtained from routine examinations. Results. There were no significant differences regarding right atrial pressure, systolic pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, cardiac index, systolic blood pressure, left ventricular ejection fraction, and mitral regurgitation (P > .05). Tricuspid regurgitation increased significantly over the 3 years of observation only among the biatrial group (P = .0212). In both groups, the right atrial pressure, pulmonary wedge capillary pressure, transpulmonary gradient, and pulmonary vascular resistance decreased significantly (P < .05) from the pre- to the postoperative examination. In both groups cardiac index and systemic blood pressure increased significantly after transplantation (P < .05). Comparative analysis of the groups only showed significant differences regarding right atrial pressure and degree of tricuspid regurgitation; the bicaval group showing the best performance. Conclusions. Both surgical techniques ensure adequate left ventricular function in the long term; however, the bicaval technique provided better trends in hemodynamic performance, as well as a lower incidence and severity of tricuspid valve dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The flux of a compound across a membrane from any formulation, whether it contains penetration enhancers or not, is limited by its saturated solubility in the vehicle. Under such conditions the concentration of the permeant in the outer layers of the stratum corneum is also saturated. Consequently, when the permeation of a drug from a supersaturated solution leads to enhanced penetration, the concentration of the drug in the outer layers of the membrane is also supersaturated. Therefore, the stratum corneum may possess antinucleant properties which inhibit or retard the crystallisation process. In this study, the enhanced in vitro permeation of supersaturated solutions of piroxicam across human skin in diffusion cells was demonstrated. The amount of permeant in the stratum corneum was determined using a tape stripping technique. Supersaturated solutions up to four degrees of saturation were investigated which produced a linear relationship between the degree of saturation and the amount of piroxicam in the stratum corneum (R-2 = 0.970). Furthermore, the amount of piroxicam in the viable layers of the skin also increased with increasing degree of saturation. An analysis of the results suggested that enhanced penetration across human skin from supersaturated solutions of piroxicam may occur as a result of the antinucleating ability of the intercellular lipids of the stratum corneum. (C) 1997 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simultaneous acquisition of electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) aims to disentangle the description of brain processes by exploiting the advantages of each technique. Most studies in this field focus on exploring the relationships between fMRI signals and the power spectrum at some specific frequency bands (alpha, beta, etc.). On the other hand, brain mapping of EEG signals (e.g., interictal spikes in epileptic patients) usually assumes an haemodynamic response function for a parametric analysis applying the GLM, as a rough approximation. The integration of the information provided by the high spatial resolution of MR images and the high temporal resolution of EEG may be improved by referencing them by transfer functions, which allows the identification of neural driven areas without strong assumptions about haemodynamic response shapes or brain haemodynamic`s homogeneity. The difference on sampling rate is the first obstacle for a full integration of EEG and fMRI information. Moreover, a parametric specification of a function representing the commonalities of both signals is not established. In this study, we introduce a new data-driven method for estimating the transfer function from EEG signal to fMRI signal at EEG sampling rate. This approach avoids EEG subsampling to fMRI time resolution and naturally provides a test for EEG predictive power over BOLD signal fluctuations, in a well-established statistical framework. We illustrate this concept in resting state (eyes closed) and visual simultaneous fMRI-EEG experiments. The results point out that it is possible to predict the BOLD fluctuations in occipital cortex by using EEG measurements. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Annular pancreas is a rare congenital anomaly, which is only surgically treated in symptomatic cases. Surgical treatment consists of bypassing the duodenal transit by gastrojejunal or duodenal-jejunal anastomosis. In the absolute majority of published cases, laparotomy is the most widely used access technique. The aim of this article is to report a case of an annular pancreas and describe the technical steps involved in carrying out a laparoscopic duodenal-jejunal anastomosis, for correction of the duodenal obstruction. The patient`s recovery was uneventful; she was discharged on the fourth postoperative day and remained asymptomatic for the 2-year, outpatient follow-up period. Laparoscopic duodenal-jejunal bypass is shown to be feasible and safe, and produce less surgical trauma, when carried out by an experienced surgeon who is duly trained and familiar with the laparoscopic technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Although various techniques have been used for breast conservation surgery reconstruction, there are few studies describing a logical approach to reconstruction of these defects. The objectives of this study were to establish a classification system for partial breast defects and to develop a reconstructive algorithm. Methods: The authors reviewed a 7-year experience with 209 immediate breast conservation surgery reconstructions. Mean follow-up was 31 months. Type I defects include tissue resection in smaller breasts (bra size A/B), including type IA, which involves minimal defects that do not cause distortion; type III, which involves moderate defects that cause moderate distortion; and type IC, which involves large defects that cause significant deformities. Type II includes tissue resection in medium-sized breasts with or without ptosis (bra size C), and type III includes tissue resection in large breasts with ptosis (bra size D). Results: Eighteen percent of patients presented type I, where a lateral thoracodorsal flap and a latissimus dorsi flap were performed in 68 percent. Forty-five percent presented type II defects, where bilateral mastopexy was performed in 52 percent. Thirty-seven percent of patients presented type III distortion, where bilateral reduction mammaplasty was performed in 67 percent. Thirty-five percent of patients presented complications, and most were minor. Conclusions: An algorithm based on breast size in relation to tumor location and extension of resection can be followed to determine the best approach to reconstruction. The authors` results have demonstrated that the complications were similar to those in other clinical series. Success depends on patient selection, coordinated planning with the oncologic surgeon, and careful intraoperative management.