980 resultados para SPECT-CT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ancien possesseur : Argenson, Antoine-René de Voyer (1722-1787 ; marquis de Paulmy d')

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ancien possesseur : Argenson, Antoine-René de Voyer (1722-1787 ; marquis de Paulmy d')

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purposes of this study were to characterize the performance of a 3-dimensional (3D) ordered-subset expectation maximization (OSEM) algorithm in the quantification of left ventricular (LV) function with (99m)Tc-labeled agent gated SPECT (G-SPECT), the QGS program, and a beating-heart phantom and to optimize the reconstruction parameters for clinical applications. METHODS: A G-SPECT image of a dynamic heart phantom simulating the beating left ventricle was acquired. The exact volumes of the phantom were known and were as follows: end-diastolic volume (EDV) of 112 mL, end-systolic volume (ESV) of 37 mL, and stroke volume (SV) of 75 mL; these volumes produced an LV ejection fraction (LVEF) of 67%. Tomographic reconstructions were obtained after 10-20 iterations (I) with 4, 8, and 16 subsets (S) at full width at half maximum (FWHM) gaussian postprocessing filter cutoff values of 8-15 mm. The QGS program was used for quantitative measurements. RESULTS: Measured values ranged from 72 to 92 mL for EDV, from 18 to 32 mL for ESV, and from 54 to 63 mL for SV, and the calculated LVEF ranged from 65% to 76%. Overall, the combination of 10 I, 8 S, and a cutoff filter value of 10 mm produced the most accurate results. The plot of the measures with respect to the expectation maximization-equivalent iterations (I x S product) revealed a bell-shaped curve for the LV volumes and a reverse distribution for the LVEF, with the best results in the intermediate range. In particular, FWHM cutoff values exceeding 10 mm affected the estimation of the LV volumes. CONCLUSION: The QGS program is able to correctly calculate the LVEF when used in association with an optimized 3D OSEM algorithm (8 S, 10 I, and FWHM of 10 mm) but underestimates the LV volumes. However, various combinations of technical parameters, including a limited range of I and S (80-160 expectation maximization-equivalent iterations) and low cutoff values (< or =10 mm) for the gaussian postprocessing filter, produced results with similar accuracies and without clinically relevant differences in the LV volumes and the estimated LVEF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The objective of our study was to establish a standardized procedure for postmortem whole-body CT-based angiography with lipophilic and hydrophilic contrast media solutions and to compare the results of these two methods. MATERIALS AND METHODS: Minimally invasive postmortem CT angiography was performed on 10 human cadavers via access to the femoral blood vessels. Separate perfusion of the arterial and venous systems was established with a modified heart-lung machine using a mixture of an oily contrast medium and paraffin (five cases) and a mixture of a water-soluble contrast medium with polyethylene glycol (PEG) 200 in the other five cases. Imaging was executed with an MDCT scanner. RESULTS: The minimally invasive femoral approach to the vascular system provided a good depiction of lesions of the complete vascular system down to the level of the small supplying vessels. Because of the enhancement of well-vascularized tissues, angiography with the PEG-mixed contrast medium allowed the detection of tissue lesions and the depiction of vascular abnormalities such as pulmonary embolisms or ruptures of the vessel wall. CONCLUSION: The angiographic method with a water-soluble contrast medium and PEG as a contrast-agent dissolver showed a clearly superior quality due to the lack of extravasation through the gastrointestinal vascular bed and the enhancement of soft tissues (cerebral cortex, myocardium, and parenchymal abdominal organs). The diagnostic possibilities of these findings in cases of antemortem ischemia of these tissues are not yet fully understood.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the diagnostic performance of multi-detector CT arthrography (CTA) and 1.5-T MR arthrography (MRA) in detecting hyaline cartilage lesions of the shoulder, with arthroscopic correlation. PATIENTS AND METHODS: CTA and MRA prospectively obtained in 56 consecutive patients following the same arthrographic procedure were independently evaluated for glenohumeral cartilage lesions (modified Outerbridge grade ≥2 and grade 4) by two musculoskeletal radiologists. The cartilage surface was divided in 18 anatomical areas. Arthroscopy was taken as the reference standard. Diagnostic performance of CTA and MRA was compared using ROC analysis. Interobserver and intraobserver agreement was determined by κ statistics. RESULTS: Sensitivity and specificity of CTA varied from 46.4 to 82.4 % and from 89.0 to 95.9 % respectively; sensitivity and specificity of MRA varied from 31.9 to 66.2 % and from 91.1 to 97.5 % respectively. Diagnostic performance of CTA was statistically significantly better than MRA for both readers (all p ≤ 0.04). Interobserver agreement for the evaluation of cartilage lesions was substantial with CTA (κ = 0.63) and moderate with MRA (κ = 0.54). Intraobserver agreement was almost perfect with both CTA (κ = 0.94-0.95) and MRA (κ = 0.83-0.87). CONCLUSION: The diagnostic performance of CTA and MRA for the detection of glenohumeral cartilage lesions is moderate, although statistically significantly better with CTA. KEY POINTS: ? CTA has moderate diagnostic performance for detecting glenohumeral cartilage substance loss. ? MRA has moderate diagnostic performance for detecting glenohumeral cartilage substance loss. ? CTA is more accurate than MRA for detecting cartilage substance loss.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Fluoroscopy-guided sacroiliac joint (SIJ) injections are technically difficult to perform because of the complex anatomy with helicoidal conformation of the joint. Our study describes the procedure of CT-guided SIJ injection, its feasibility and its rate of success. Methods and materials: Retrospective study included 46 consecutive patients. The procedure was performed by 3 MSK radiologists and consisted in a puncture with a posterior approach in the inferior articular part of SIJ, then in an injection of iodinated contrast agent (1ml) with CT control of SIJ space opacification and finally in an injection of slowacting corticosteroid. The SIJ approach was noticed as correct if there was an inferior articular puncture and if the needle was in the articular space, and as impossible if there was ankylosis or osteophytosis. The study was divided in two successive periods: period 1 (4 first months) and period 2 (12 last months). Results: SIJ opacification was successful in 57% (26/46). We observed a learning curve: opacification was succeeded in 66% (23/35) and there was incorrect approach in 9% (3/35) during period 2 versus respectively 27% (3/11) and 45% (5/11) during period 1. Causes of failure were incorrect approach in 40% (6/20 too low, 2/20 too high), impossible approach in 30% (6/20) and unexplained in 30% (6/20). Mean duration of procedure was about 28 minutes. No complication occurred. Conclusion: CT guided SIJ injection is safe and successful in 66% after a training period. The success depends on SIJ correct approach and also on anatomical lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the current limited availability of organs for transplantation, it is important to consider marginal donor candidates, including survivors of potentially curable malignancies such as lymphoma. The absence of refractory/recurrent residual disease at the time of brain death can be difficult to establish. Therefore, it is critical to have objective data to decide whether to proceed or not with organ procurement and transplantation. We report a unique situation in which (18)F-fluorodeoxyglucose positron emission tomography (PET) was used to rule out Hodgkin's lymphoma recurrence in a 33-year-old, heart-beating, brain-dead, potential donor with a past history of Hodgkin's disease and a persistent mediastinal mass. PET showed no significant uptake in the mass, allowing organ donation and transplantation to occur. We present a new means of evaluating potential brain-dead donors with a past history of some lymphoma, whereby PET may help transplant physicians by optimizing donation safety while rationalizing the inclusion of marginal donors.