548 resultados para SCS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Computer-aided design/computer-aided manufacturing images can be taken through either direct or indirect imaging. For the indirect systems, the digitalization is obtained from the impression material or cast, and for the direct ones the image is taken directly from the mouth using intraoral scanners.The direct acquisition systems have been constantly improved because these are less invasive, quicker, and more precise than the conventional method. Besides, the digital images can be easily stored for a long time. Therefore, the aim of this paper was to describe and discuss based on the literature the main direct image acquisition systems available on the market: CEREC Bluecam (Sirona), Lava C.O.S. System (3M ESPE), iTero System (Cadent/Straumann), and E4D System (D4D Technologies).
Resumo:
Because of the widespread use of implant-supported restorations and that the success of this treatment depends on the passivity of the different component systems of implant-prosthesis, a literature review was performed to highlight issues related to passivity in framework of implant-supported fixed prosthesis. A search of English-language peer-review literature was completed using MEDLINE database (PubMed) focusing on acceptable levels of passivity, misfit classification, problems related to misfit, methods to evaluate misfit, general factors that affect the passivity, and the biologic tolerance in the presence of misfit. The information obtained in the present review suggested that even if it is hard to obtain an implant-supported prosthesis with complete passivity, the professional should use the technological resources to offer better conditions for their patients. An acceptable clinical level of passivity that does not cause any problem to the biologic, aesthetic, and functional parameters of the patient should be sought.
Resumo:
The authors describe a literature revision on assessing stresses in buccomaxillary prostheses photoelasticity, finite element technique, and extensometry. They describe the techniques and the importance for use of each method in buccomaxillary prostheses with implants and the need of accomplishing more studies in this scarce literary area.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to evaluate the biomechanical behavior of a mandibular distal extension removable partial denture (DERPD) associated with an implant and different retention system, by bidimensional finite element method. Five hemimandible models with a canine and external hexagon implant at second molar region associated with DERPD were simulated: model A, hemimandible with a canine and a DERPD; model B, hemimandible with a canine and implant with a healing abutment associated to a DERPD; model C, hemimandible with a canine and implant with an ERA attachment associated to a DERPD; model D, hemimandible with a canine and implant with an O'ring attachment associated to a DERPD; and model E, hemimandible with a canine and implant-supported prosthesis associated to a DERPD. Cusp tips were loaded with 50 N of axial or oblique force (45 degrees). Finite element analysis was performed in ANSYS 9.0. model E showed the higher displacement and overload in the supporting tissues; the patterns of stress distribution around the dental apex of models B, C, and D were similar. The association between a DERPD and an osseointegrated implant using the ERA or O'ring systems shows lower stress values. Oblique forces showed higher stress values and displacement. Oblique forces increased the displacement and stress levels in all models; model C displayed the best stress distribution in the supporting structures; healing abutment, ERA, and O'ring systems were viable with RPD, but DERPD association with a single implant-supported prosthesis was nonviable.
Resumo:
The aim of the present study was to conduct a critical literature review about the technique of computer-guided surgery in implantology to highlight the indications, purposes, immediate loading of implants and complications, protocol of fabrication, and functioning of virtual planning software. This literature review was based on OLDMEDLINE and MEDLINE databases from 2002 to 2010 using the key words "computer-guided surgery" and "implant-supported prosthesis." Thirty-four studies regarding this topic were found. According to the literature review, it was concluded that the computer-assisted surgery is an excellent treatment alternative for patients with appropriate bone quantity for implant insertion in complete and partially edentulous arches. The Procera Nobel Guide software (Nobel Biocare) was the most common software used by the authors. In addition, the flapless surgery is advantageous for positioning of implants but with accurate indication. Although the computer-guided surgery may be helpful for virtual planning of cases with severe bone resorption, the conventional surgical technique is more appropriate. The surgical guide is important for insertion of the implants regardless of the surgical technique, and the success of immediate loading after computer-guided surgery depends on the accuracy of clinical and/or laboratorial steps.
Resumo:
The objective of the study was to report the prevention of facial reinjury of a volleyball player using a custom-made protective facial shield. A custom-made protective partial facial shield was fabricated using polymethylmethacrylate and was fitted with a soft lining material to provide additional comfort and protection to the injured area. Facial protection provides greater security against possible facial injuries and allows injured areas to recover during sports practice.
Resumo:
The restoration and recovery of a compromised skull continues to be a challenge to craniofacial surgeons and neurosurgeons. Different operative techniques and implant materials are being used to reconstruct the rigid framework of the skull. However, no currently available materials satisfy all of these criteria. According to this premise, the aim of this study was to report on the currently available materials for the reconstruction of the cranial vault and to describe their main characteristics, advantages, and disadvantages. Although the use of the materials discussed in this study is clearly positive for the reconstruction of skull defects and cranioplasties, there is a need for more complex studies and research into developing these materials to achieve all the ideal prerequisites stipulated by the scientific community and to evaluate their properties and aesthetic and functional results in the long term.
Resumo:
The purpose of this study was to present a literature review about photoelasticity, a laboratory method for evaluation of implants prosthesis behavior. Fixed or removable prostheses function as levers on supporting teeth, allowing forces to cause tooth movement if not carefully planned. Hence, during treatment planning, the dentist must be aware of the biomechanics involved and prevent movement of supporting teeth, decreasing lever-type forces generated by these prosthesis. Photoelastic analysis has great applicability in restorative dentistry as it allows prediction and minimization of biomechanical critical points through modifications in treatment planning.
Resumo:
One of the concerns after a major trauma to the orbit is to be rebuilt. This can be achieved with care in management of orbital reconstruction, techniques, types of materials, and osseointegrated implants; it allows satisfactory aesthetic recuperation and well-being, whereas psychological therapy allows for patients' re-insertion in social and family environment to make them feel happier and safer.
Resumo:
Complete and partial loss of maxillary bone may jeopardize oral physiology and generate complications as oral-sinus-nasal communication. Palatal obturator prostheses are a treatment alternative for rehabilitation of these patients. The aim of this study was to assess stress distribution, through photoelasticity, on palatal obturator prostheses associated with different attachment systems (o'ring, bar clip, and o'ring/bar clip) of implants and submitted to relining. Two photoelastic models were fabricated according to an experimental maxillary model with oral-sinus-nasal communication. One model did not present implants, whereas the other included 2 implants with 13.0 mm in length in the left ridge. Four colorless maxillary obturator prostheses were fabricated and relined with soft silicone. One of these prostheses presented no attachment system, whereas the remaining prostheses included attachment systems adapted to the implants. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope during loading with 100 N at 10 mm/s. The results were based on observation during the experiment and photographic records of stress on the photoelastic model. The bar clip system exhibited the highest stress concentration followed by o'ring/bar clip and o'ring systems. The attachment systems presented different stress distribution with greater concentration surrounding the implants and homogenous stress distribution on the photoelastic model without implants. The highest concentration of fringes occurred, in ascending order, with o'ring, o'ring/bar clip, and bar clip systems.
Resumo:
The failure of facial prostheses is caused by limitations in the properties of existing materials, especially flexibility and durability. Therefore, this study evaluated the Shore A hardness of silicone used for fabrication of facial prostheses, Silastic MDX4-4210, according to the influence of storage period, daily disinfection, and 2 types of pigmentation. Thirty specimens were fabricated and divided in 3 groups: colorless, pigmented with makeup, and pigmented with iron oxide. Analysis of results was assessed on a Shore A hardness meter immediately, 6 months, and 1 year after fabrication of specimens, following the guidelines of the American Society for Testing and Materials. The hardness values were statistically analyzed by the Tukey test. The silicone exhibited an increase in hardness with time. However, the hardness was stable from 6 months to 1 year. It was concluded that the silicone is within the values of Shore A hardness reported in the literature, regardless of the storage period, pigmentation, and chemical disinfection.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The use of craniofacial implants is an effective treatment for patients with deformities, burns, and cancer sequelae. The sites with the most successful implants are the auricular, nasal, and orbital regions. Furthermore, other factors can affect the implant longevity such as irradiated area, surgical technique, bone quality and quantity, macrostructure and microstructure of the implant, maintenance, and systemic factors.