971 resultados para Removable partial denture. Dental impression technique. Mandible.Partially edentulous arch
Resumo:
PURPOSE: The aim of this study was to evaluate the 3-year success rates of wide-body implants with a regular- or wide-neck configuration and a sandblasted, large grit, acid-etched (SLA) surface. MATERIALS AND METHODS: A total of 151 implants were consecutively placed in posterior sites of 116 partially edentulous patients in a referral clinic at the School of Dental Medicine, University of Bern. All implants were restored with cemented crowns or fixed partial dentures after a healing period of 6 to 8 weeks (for implants placed without simultaneous bone augmentation) or 10 to 14 weeks (for implants with simultaneous bone augmentation). All patients were recalled 36 months following implant placement for a clinical and radiographic examination. RESULTS: One implant failed to integrate during healing, and 11 implants were lost to follow-up and considered dropouts. The remaining 139 implants showed favorable clinical and radiographic findings and were considered successfully integrated at the 3-year examination. This resulted in a 3-year success rate of 99.3%. Radiographic evaluation of 134 implants indicated stability of the crestal bone levels: During the study period, the crestal bone level changed less than 0.5 mm for 129 implants. CONCLUSION: Successful tissue integration was achieved with wide-body implants with a regular or a wide-neck configuration and an SLA surface with high predictability. This successful tissue integration was well maintained for up to 3 years of follow-up.
Resumo:
Different types of titanium-alloys instead of CoCr-alloys have been tested as material for the framework of removable partial dentures (RPD). Adequate casting and processing techniques have been developed which enable to fabricate frameworks of complex designs and the problem limits porosity. This opened new possibilities for the use of titanium-alloys with improved properties (E-module). The aim of this study was to summarise the use of titanium in removable prosthodontics and to evaluate prospectively the use of the Ti6A17Nb-alloy for RPDs in a small group of patients. Two identically designed RPDs from CoCr-alloy (remanium GM 800+) and Ti6A17Nb-alloy (girotan L) were produced for ten patients. They had to wear each RPD during six months, first the CoCr-RPD and then the Ti6A17Nb-RPD. A questionnaire (visual analogue scale = VAS) was completed by the patients after one, three and six months of function for each RPD. Prosthetic complications and service needed were recorded. After the end of the entire observation period of twelve months, the patients remained with the Ti6A17Nb-RPD and answered the questionnaire after another six months. All parameters regarding the design of the RPDs were positively estimated by the dentist. Minimal, not significant differences were noted by the patients concerning comfort, stability and retention (VAS). Clinically, no differences in technical aspects or regarding biological complications were observed after six-months periods. The Ti6A17Nb-alloy (girotan L) for the framework of RPDs was judged by patients and professionals to be equivalent to RPDs made from CoCr-alloy. No differences in material aspects could objectively be observed. The Ti6A17Nb-alloy can be beneficial for patients with allergies or incompatibility with one or several components of the CoCr-alloy.
Resumo:
PURPOSE Clinical studies related to the long-term outcomes with implant-supported reconstructions are still sparse. The aim of this 10-year retrospective study was to assess the rate of mechanical/technical complications and failures with implant supported fixed dental prostheses (FDPs) and single crowns (SCs) in a large cohort of partially edentulous patients. MATERIALS AND METHODS The comprehensive multidisciplinary examination consisted of a medical/dental history, clinical examination, and a radiographic analysis. Prosthodontic examination evaluated the implant-supported reconstructions for mechanical/technical complications and failures, occlusal analysis, presence/absence of attrition, and location, extension, and retention type. RESULTS Out of three hundred ninety seven fixed reconstructions in three hundred three patients, two hundred sixty eight were SCs and one hundred twenty seven were FDPs. Of these three hundred ninety seven implant-supported reconstructions, 18 had failed, yielding a failure rate of 4.5% and a survival rate of 95.5% after a mean observation period of 10.75 years (range: 8.4-13.5 years). The most frequent complication was ceramic chipping (20.31%) followed by occlusal screw loosening (2.57%) and loss of retention (2.06%). No occlusal screw fracture, one abutment loosening, and two abutment fractures were noted. This resulted in a total mechanical/technical complication rate of 24.7%. The prosthetic success rate over a mean follow-up time of 10.75 years was 70.8%. Generalized attrition and FDPs were associated with statistically significantly higher rates of ceramic fractures when compared with SCs. Cantilever extensions, screw retention, anterior versus posterior, and gender did not influence the chipping rate. CONCLUSIONS After a mean exposure time of 10.75 years, high survival rates for reconstructions supported by Sand-blasted Large-grit Acid-etched implants can be expected. Ceramic chipping was the most frequent complication and was increased in dentitions with attrition and in FDPs compared with SCs.
Resumo:
Objectives: The purpose of this study is to understand the perceived effects of patient-dental staff communication and cultural diversity on the utilization of dental services in the U.S. by Saudi Arabian students who live in the U.S. and enrolled into the King Abdullah Scholarship program. Methods: The study design was an analytical cross-sectional study. Data for this study was obtained from the Saudi Dental Servicers Utilization Survey, a voluntary internet survey available online for one month through Facebook. Ordered logistic regression analyses and multinomial logistic regression analyses were used to measure the relationships between patient-dental staff communication and cultural diversity on the utilization of dental services. Results: Eight hundred and forty-seven responses were analyzed for this study. Overall, the majority of Saudi students reported having excellent communication experience with dental providers in the U.S. More than 58% of respondents reported at least one regular dental visit last year. Factors that influenced the use of regular dental care were: dentist's explanation of treatment plan, response of dental staff to patient's needs, respectful and polite dental staff, dental staff kindness, availability of up-to-date equipment, and overall communication with dentist. However, the utilization of emergency dental care was not associated with any measurement of patient-dental provider communication. Overall future utilization of dental care is associated with all aspects of patient-dental staff communication measured in this survey. Furthermore, more utilization of regular dental care was related to respondent's perception of the importance of trustworthiness dental staff and the importance of a dentist's reputation was only marginally associated. Respondent's perception of dentist's reputation was associated with more use of emergency dental services. Respondents are more likely to anticipate using dental care in the future if they perceived trustworthiness dental staff, and the dentist's reputation as influencing factors to their usage of dental services. Conclusions: Patient-dental staff communication was partially associated with utilization of regular dental care, not associated with utilization of emergency dental care, and broadly associated with anticipated future utilization of dental care. In addition, trustworthy dental staff, and a dentist's reputation were considered to be strong influencing factors towards utilization of dental services.^
Resumo:
Introduction: Infiltration of organic fluids and microorganisms at the abutment/implant interface may result in bacterial infection of peri-implant tissues. Internal colonization of periodontal pathogens may be caused by bacteria trapped during installation or penetration of abutment/implant leakage. The aim of this study was to detect periodontal pathogens in the internal area of dental implants before loading. Materials and Methods: Seventy-eight implants in 32 partially edentulous subjects were selected for this evaluation. A bacterial biofilm sample of the internal surface of each implant was taken and analyzed for the presence of 40 microorganisms by checkerboard DNA-DNA hybridization, prior to installation of healing or any other prosthetic abutment. Discussion: Bacteria were detected in 20 patients (62.5%), distributed in 41 implants (52.6%). Forty-seven percent of implants showed no bacterial detection. Spontaneous early implant exposure to oral cavity during the healing period was not significant (P >0.05) to increase bacterial prevalence, but implants placed at mandible had higher bacterial prevalence than maxillary ones. Conclusion: The internal surface of dental implants can serve as a reservoir of periodontal pathogens for future implant/abutment interface.
Resumo:
Objective: To perform a long-term clinical evaluation of the periodontium of removable parti al denture (RPD) wearers, comparing the direct pillar teeth of tooth-supported and toothtissue supported RPDs. Method: Fifty patients with mean age of 45 years were enrolled in the study. The individuals were examined by a single examiner at the moment of denture installation and after 3, 6, 9 and 12 months. In each exam, the following parameters were verified: gingival recession (GR), probing depth (PD), plaque index (PI), gingival index (GI) e amount kerati nized mucosa (KM). All patients received oral hygiene instructions and prophylaxis and, when necessary, scaling and root planing. An analysis from the confidence interval was done to evaluate the endpoints regarding the type of denture in the direct pillar group. Results: The tooth-tissue supported dentures showed significantly higher GR, GI and PI values, and significantly lower KM values. Over time, neither of the types of denture presented statistically significant difference from the initial to the final examination for the parameters GR, PD, KM and GI, while the PI was significant only for the tooth-supported dentures. Conclusion: Pillar teeth adjacent to free ends presented a less favorable periodontal conditi on than the pillar teeth adjacent to intercalated spaces. However, the use of RPD did not aggravate the initial condition, after a follow-up period of 12 months. The findings of the study indicate that, within 1 year, there were no significant differences between the direct pillars of the toothsupported and tooth-ti ssue supported dentures, and suggest the need of professional follow up for a longer period.
Resumo:
Objective: To perform a long-term clinical evaluation of the periodontium of removable parti al denture (RPD) wearers, comparing the direct pillar teeth of tooth-supported and toothtissue supported RPDs. Method: Fifty patients with mean age of 45 years were enrolled in the study. The individuals were examined by a single examiner at the moment of denture installation and after 3, 6, 9 and 12 months. In each exam, the following parameters were verified: gingival recession (GR), probing depth (PD), plaque index (PI), gingival index (GI) e amount kerati nized mucosa (KM). All patients received oral hygiene instructions and prophylaxis and, when necessary, scaling and root planing. An analysis from the confidence interval was done to evaluate the endpoints regarding the type of denture in the direct pillar group. Results: The tooth-tissue supported dentures showed significantly higher GR, GI and PI values, and significantly lower KM values. Over time, neither of the types of denture presented statistically significant difference from the initial to the final examination for the parameters GR, PD, KM and GI, while the PI was significant only for the tooth-supported dentures. Conclusion: Pillar teeth adjacent to free ends presented a less favorable periodontal conditi on than the pillar teeth adjacent to intercalated spaces. However, the use of RPD did not aggravate the initial condition, after a follow-up period of 12 months. The findings of the study indicate that, within 1 year, there were no significant differences between the direct pillars of the toothsupported and tooth-ti ssue supported dentures, and suggest the need of professional follow up for a longer period.
Resumo:
The aim of this study was to comparatively assess dental arch width, in the canine and molar regions, by means of direct measurements from plaster models, photocopies and digitized images of the models. The sample consisted of 130 pairs of plaster models, photocopies and digitized images of the models of white patients (n = 65), both genders, with Class I and Class II Division 1 malocclusions, treated by standard Edgewise mechanics and extraction of the four first premolars. Maxillary and mandibular intercanine and intermolar widths were measured by a calibrated examiner, prior to and after orthodontic treatment, using the three modes of reproduction of the dental arches. Dispersion of the data relative to pre- and posttreatment intra-arch linear measurements (mm) was represented as box plots. The three measuring methods were compared by one-way ANOVA for repeated measurements (α = 0.05). Initial / final mean values varied as follows: 33.94 to 34.29 mm / 34.49 to 34.66 mm (maxillary intercanine width); 26.23 to 26.26 mm / 26.77 to 26.84 mm (mandibular intercanine width); 49.55 to 49.66 mm / 47.28 to 47.45 mm (maxillary intermolar width) and 43.28 to 43.41 mm / 40.29 to 40.46 mm (mandibular intermolar width). There were no statistically significant differences between mean dental arch widths estimated by the three studied methods, prior to and after orthodontic treatment. It may be concluded that photocopies and digitized images of the plaster models provided reliable reproductions of the dental arches for obtaining transversal intra-arch measurements.
Resumo:
This study analyzed the reaction layer and measured the marginal crown fit of cast titanium applied to different phosphate-bonded investments, prepared under the following conditions (liquid concentration/casting temperature): Rema Exakt (RE) - 100%/237°C, 75%/287°C, Castorit Super C (CS)-100%/70°C, 75%/141°C and Rematitan Plus (RP)- 100%/430°C (special to titanium cast, as the control group). The reaction layer was studied using the Vickers hardness test, and analyzed by two way ANOVA and Tukey's HSD tests (α = 0.05). Digital photographs were taken of the crowns seated on the die, the misfit was measured using an image analysis system and One-way ANOVA, and Tukey's test was applied (α = 0.05). The hardness decreased from the surface (601.17 VHN) to 150 μm (204.03 VHN). The group CS 75%/141°C presented higher hardness than the other groups, revealing higher surface contamination, but there were no differences among the groups at measurements deeper than 150 μm. The castings made with CS - 100%/70°C presented the lowest levels of marginal misfit, followed by RE -100%/237°C. The conventional investments CS (100%) and RE (100%) showed better marginal fit than RP, but the CS (75%) had higher surface contamination.
Resumo:
This study evaluated in vitro the pulp chamber temperature rise induced by the light-activated dental bleaching technique using different light sources. The root portions of 78 extracted sound human mandibular incisors were sectioned approximately 2 mm below the cementoenamel junction. The root cavities of the crowns were enlarged to facilitate the correct placing of the sensor into the pulp chamber. Half of specimens (n=39) was assigned to receive a 35% hydrogen peroxide gel on the buccal surface and the other halt (n=39) not to receive the bleaching agent. Three groups (n=13) were formed for each condition (bleach or no bleach) according to the use of 3 light sources recommended for dental bleaching: a light-emitting diode (LED)laser system, a LED unit and a conventional halogen light. The light sources were positioned perpendicular to the buccal surface at a distance of 5 mm and activated during 30 s. The differences between the initial and the highest temperature readings for each specimen were obtained, and, from the temperature changes, the means for each specimen and each group were calculated. The values of temperature rise were compared using Kruskal-Wallis test at 1% significance level. Temperature rise varied significantly depending on the light-curing unit, with statistically significant differences (p<0.01) among the groups. When the bleaching agent was not applied, the halogen light induced the highest temperature rise (2.38±0.66ºC). The LED unit produced the lowest temperature increase (0.29±0.13ºC); but there was no significant difference between LED unit and LED-laser system (0.35±0.15ºC) (p>0.01). When the bleaching agent was applied, there were significant differences among groups (p<0.01): halogen light induced the highest temperature rise (1.41±0.64ºC), and LED-laser system the lowest (0.33±0.12ºC); however, there was no difference between LED-laser system and LED unit (0.44±0.11ºC). LED and LED-laser system did not differ significantly from each other regardless the temperature rise occurred with or without bleaching agent application. It may be concluded that during light-activated tooth bleaching, with or without the bleaching agent, halogen light promoted higher pulp chamber temperature rise than LED unit and LED-laser system. The tested light-curing units provided increases in the pulp chamber temperature that were compatible with pulpal health.
Resumo:
O objetivo deste estudo é descrever e analisar as representações sociais dos conselheiros de saúde sobre a temática da vigilância sanitária. A pesquisa qualitativa de representação social foi adotada como metodologia, sendo utilizada a técnica de entrevista baseada em roteiro semiestruturado. Os dados obtidos com a realização das entrevistas foram analisados pela técnica do Discurso do Sujeito Coletivo. Através dos discursos, os conselheiros de saúde demonstraram conhecer a vigilância sanitária e reconhecerem sua importância para as práticas de Saúde Pública. Demonstraram também, estarem aptos a participar do processo de formulação da Política Municipal de Vigilância Sanitária. O estudo conclui que a vigilância sanitária, principalmente na esfera local, precisa se apropriar dos conselhos de saúde como espaços públicos capazes de legitimar e dar transparência às suas ações, discutindo as necessidades da coletividade democraticamente com a sociedade, sendo possível, dessa forma, construir a cidadania ao mesmo tempo em que se assegura o direito à proteção da saúde.
Resumo:
The aim of this study was to evaluate some biological characteristics and toxicity of basic formulations of dentifrices containing such substances, and to compare them with two existing products in market which also contains silic in their formulations. In this way, it was evaluated some biological parameters: weight of the animals, oral toxicity, hematological parameters, urinary analysis, and histological evaluation. The thrombocytes were also statistically at normal levels. The glutamate-pyruvate transaminase (TGP) showed normal aspect in 5 of the tested groups, as in control. Meanwhile, the oxalacetic transaminase (AST) in one group had a small increase in the control group. Regarding urine, in exception the rats of one group, the rats of the 4 other experimental groups showed leukocytosis urinary statistically higher than the control group. The histological evaluation of the animals showed that specimens from liver, stomach, kidney and submandibular gland presented normal aspects for these organs, without significant characteristics related to inflammatory infiltrates in any of the 6 samples tested in their respective groups.
Resumo:
Objectives To compare the reliability of the disto-facial (DF) and mesio-lingual (ML) cusps of an anatomically correct zirconia (Y-TZP) crown system The research hypotheses tested were (1) fatigue reliability and failure mode are similar for the ML and DF cusps, (2) failure mode of one cusp does not affect the failure of the other Methods The average dimensions of a mandibular first molar crown were imported into CAD software, a tooth preparation was modelled by 1 5 mm marginal high reduction of proximal walls and occlusal surface by 2 0 mm The CAD-based tooth preparation was milled and used as a die to fabricate crowns (n = 14) with porcelain veneer on a 0 5 mm Y-TZP core. Crowns were cemented on composite reproductions of the tooth preparation The crowns were step-stress mouth motion fatigued with sliding (0 7 mm) a tungsten-carbide indenter of 6 25 mm diameter down on the inclines of either the DF or ML cusps Use level probability Weibull curve with use stress of 200 N and the reliability for completion of a mission of 50,000 cycles at 200 N load were calculated Results Reliability for a 200 N at 50,000 cycles mission was not different between tested cusps SEM imaging showed large cohesive failures within the veneer for the ML and smaller for the DF Fractures originated from the contact area regardless of the cusp loaded Conclusion No significant difference on fatigue reliability was observed between the DF compared to the ML cusp Fracture of one cusp did not affect the other (c) 2010 Elsevier Ltd All rights reserved
Resumo:
Objectives: The purpose of this study was to investigate the effect of the domestic use of a disclosing agent for denture hygiene. Materials and methods: Completely edentulous participants wearing maxillary dentures were randomly assigned to one of the three intervention groups: (1) Follow-up only (control; n = 12); (2) Oral and denture hygiene instructions (n = 10); (3) Instructions associated with the home use of a disclosing agent (1% neutral red; n = 10). Biofilm coverage area (%) over internal and external surfaces of the maxillary denture was assessed at baseline and after 14 and 90 days. Data were evaluated by generalised estimating equations based on score tests (alpha = 0.05). Results: The participants presented low changes for areas of biofilm coverage (14 days (%): internal: GI = 1.4 +/- 0.9; GII = 1.5 +/- 1.3; GIII = -0.4 +/- 0.9; external: GI = 1.4 +/- 1.5; GII = 1.5 +/- 1.4; GIII = -0.4 +/- 0.9; 90 days (%): internal: GI = 2.0 +/- 0.9; GII = 2.2 +/- 1.4; GIII = 0.3 +/- 1.0; external: GI = 2.1 +/- 1.4; GII = 2.2 +/- 1.5; GIII = 0.3 +/- 0.9). Changes were similar for the three groups (p = 0.293) and were not influenced by the test time (p = 0.218). Conclusion: It can be concluded that the home use of a disclosing agent for denture hygiene does not improve the removal of the biofilm, particularly for patients with adequate oral hygiene habits.
Resumo:
Protein S (ProS) is an important negative regulator of blood coagulation. Its physiological importance is evident in purpura fulminans and other life-threatening thrombotic disorders typical of ProS deficient patients. Our previous characterization of ProS deficiency in mouse models has shown similarities with the human phenotypes: heterozygous ProS-deficient mice (Pros+/-) had increased thrombotic risk whereas homozygous deficiency in ProS (Pros-/-) was incompatible with life (Blood 2009; 114:2307-2314). In tissues, ProS exerts cellular functions by binding to and activating tyrosine kinase receptors of the Tyro3 family (TAM) on the cell surface.To extend the analysis of coagulation defects beyond the Pros-/- phenotype and add new insights into the sites of synthesis ProS and its action, we generated mice with inactivated ProS in hepatocytes (Proslox/loxAlbCre+) as well as in endothelial and hematopoietic cells (Proslox/loxTie2Cre+). Both models resulted in significant reduction of circulating ProS levels and in a remarkable increased thrombotic risk in vivo. In a model of tissue factor (TF)-induced venous thromboembolism (VTE), only 17% of Proslox/loxAlbCre+ mice (n=12) and only 13% of Proslox/loxTie2Cre+ mice (n=14) survived, compared with 86% of Proslox/lox mice (n=14; P<0.001).To mimic a severe acquired ProS deficiency, ProS gene was inactivated at the adult stage using the polyI:C-inducible Mx1-Cre system (Proslox/loxMx1Cre+). Ten days after polyI:C treatment, Proslox/loxMx1Cre+ mice developed disseminated intravascular coagulation with extensive lung and liver thrombosis.It is worth noting that no skin lesions compatible with purpura fulminans were observed in any of the above-described models of partial ProS deficiency. In order to shed light on the pathogenesis of purpura fulminans, we exposed the different ProS-deficient mice to warfarin (0.2 mg/day). We observed that Pros+/-, Proslox/loxAlbCre+ and Proslox/loxTie2Cre+ mice developed retiform purpura (characterized by erythematous and necrotic lesions of the genital region and extremities) and died after 3 to 5 days after the first warfarin administration.In human, ProS is also synthesized by megakaryocytes and hence stored at high concentrations in circulating platelets (pProS). The role of pProS has been investigated by generating megakaryocyte ProS-deficient model using the PF4 promoter as Cre driver (Proslox/loxPf4Cre+). In the TF-induced VTE model, Proslox/loxPf4Cre+ (n=15) mice showed a significant increased risk of thrombosis compared to Proslox/lox controls (n=14; survival rate 47% and 86%, respectively; P<0.05). Furthermore, preliminary results suggest survival to be associated with higher circulating ProS levels. In order to evaluate the potential role of pProS in thrombus formation, we investigated the thrombotic response to intravenous injection of collagen-epinephrine in vivo and platelet function in vitro. Both in vivo and in vitro experiments showed similar results between Proslox/loxPf4Cre+ and Proslox/lox, indicating that platelet reactivity was not influenced by the absence of pProS. These data suggest that pProS is delivered at the site of thrombosis to inhibit thrombin generation.We further investigated the ability of ProS to function as a ligand of TAM receptors, by using homozygous and heterozygous deficient mice for both the TAM ligands ProS and Gas6. Gas6-/-Pros-/- mice died in utero and showed comparable dramatic bleeding and thrombotic phenotype as described for Pros-/- embryos.In conclusion, like complete ProS deficiency, double deficiency in ProS and Gas6 was lethal, whereas partial ProS deficiency was not. Mice partially deficient in ProS displayed a prothrombotic phenotype, including those with only deficiency in pProS. Purpura fulminans did not occur spontaneously in mice with partial Pros deficiency but developed upon warfarin administration.Thus, the use of different mice models of ProS deficiency can be instrumental in the study of its highly variable thrombotic phenotype and in the investigation of additional roles of ProS in inflammation and autoimmunity through TAM signaling.