293 resultados para Radioisotope brachytherapy


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A medical cyclotron accelerating H- ions to 18 MeV is in operation at the Bern University Hospital (Inselspital). It is the commercial IBA 18/18 cyclotron equipped with a specifically conceived 6 m long external beam line ending in a separate bunker. This feature is unique for a hospital-based facility and makes it possible to conduct routine radioisotope production for PET diagnostics in parallel with multidisciplinary research activities, among which are novel particle detectors, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. Several of these activities, such as radiobiology experiments for example, require low current beams down to the pA range, while medical cyclotrons are designed for high current operation above 10 μA. In this paper, we present the first results on the low current performance of a PET medical cyclotron obtained by ion source, radio-frequency and main coil tuning. With this method, stable beam currents down to (1.5+/- 0.5 ) pA were obtained and measured with a high-sensitivity Faraday cup located at the end of the beam transport line.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nuevas aplicaciones tecnológicas y científicas mediante amarras electrodinámicas son analizadas para misiones planetarias. i) Primero, se considera un conjunto de amarras cilíndricas en paralelo (veleros electrosolares) para una misión interplanetaria. Los iones provenientes del viento solar son repelidos por el alto potencial de dichas amarras generando empuje sobre el velero. Para conocer el intercambio de momento que provocan los iones sobre las amarras se ha considerado un modelo de potencial estacionario. Se ha analizado la transferencia orbital de la Tierra a Júpiter siguiendo un método de optimización de trayectoria indirecto. ii) Una vez que el velero se encuentra cerca de Júpiter, se ha considerado el despliegue de una amarra para diferentes objetivos científicos. iia) Una amarra podría ser utilizada para diagnóstico de plasmas, al ser una fuente efectiva de ondas, y también como un generador de auroras artificiales. Una amarra conductora que orbite en la magnetosfera jovial es capaz de producir ondas. Se han analizado las diferentes ondas radiadas por un conductor por el que circula una corriente constante que sigue una órbita polar de alta excentricidad y bajo apoápside, como ocurre en la misión Juno de la NASA. iib) Además, se ha estudiado una misión tentativa que sigue una órbita ecuatorial (LJO) por debajo de los intensos cinturones de radiación. Ambas misiones requiren potencia eléctrica para los sistemas de comunicación e instrumentos científicos. Las amarras pueden generar potencia de manera más eficiente que otros sistemas que utlizan paneles solares o sistemas de potencia de radioisótopos (RPS). La impedancia de radiación es necesaria para determinar la corriente que circula por todo el circuito de la amarra. En un modelo de plasma frío, la radiación ocurre principalmente en los modos de Alfven y magnetosónica rápida, mostrando un elevado índice de refracción. Se ha estudiado la impedancia de radiación en amarras con recubrimiento aislante para los dos modos de radiación y cada una de las misiones. A diferencia del caso ionosférico terrestre, la baja densidad y el intenso campo magnético que aparecen en el entorno de Júpiter consiguen que la girofrecuencia de los electrones sea mucho mayor que la frecuencia del plasma; esto hace que el espectro de potencia para cada modo se modifique substancialmente, aumentando la velocidad de Alfven. Se ha estimado también la impedancia de radiación para amarras sin aislante conductor. En la misión LJO, un vehículo espacial bajando lentamente la altitud de su órbita permitiría estudiar la estructura del campo magnético y composición atmosférica para entender la formación, evolución, y estructura de Júpiter. Adicionalmente, si el contactor (cátodo) se apaga, se dice que la amarra flota eléctricamente, permitiendo emisión de haz de electrones que generan auroras. El continuo apagado y encendido produce pulsos de corriente dando lugar a emisiones de señales, que pueden ser utilizadas para diagnóstico del plasma jovial. En Órbita Baja Jovial, los iones que impactan contra una amarra polarizada negativamente producen electrones secundarios, que, viajando helicoidalmente sobre las líneas de campo magnético de Júpiter, son capaces de alcanzar su atmósfera más alta, y, de esta manera, generar auroras. Se han identificado cuáles son las regiones donde la amarra sería más eficiente para producir auroras. iic) Otra aplicación científica sugerida para la misión LJO es la detección de granos cargados que orbitan cerca de Júpiter. Los electrones de alta energía en este ambiente pueden ser modelados por una distribucción no Maxwelliana conocida como distribución kappa. En escenarios con plasmas complejos, donde los campos eléctricos en Júpiter pueden acelerar las cargas hasta velocidades que superen la velocidad térmica, este tipo de distribuciones son muy útiles. En este caso las colas de las distribuciones de electrones siguen una ley de potencias. Se han estudiado las fluctuaciones de granos cargados para funciones de distribución kappa. iii) La tesis concluye con el análisis para deorbitar satélites con amarras electrodinámicas que siguen una Órbita Baja Terrestre (LEO). Una amarra debe presentar una baja probabilidad de corte por pequeño debris y además debe ser suficientemente ligero para que el cociente entre la masa de la amarra y el satélite sea muy pequeño. En este trabajo se estiman las medidas de la longitud, anchura y espesor que debe tener una amarra para minimizar el producto de la probabilidad de corte por el cociente entre las masas de la amarra y el satélite. Se presentan resultados preliminares del diseño de una amarra con forma de cinta para deorbitar satélites relativamente ligeros como Cryosat y pesados como Envisat. Las misiones espaciales a planetas exteriores y en el ámbito terrestre plantean importantes retos científico-tecnológicos que deben ser abordados y solucionados. Por ello, desde el inicio de la era espacial se han diseñando novedosos métodos propulsivos, sistemas de guiado, navegación y control más robustos, y nuevos materiales para mejorar el rendimiento de los vehículos espaciales (SC). En un gran número de misiones interplanetarias y en todas las misiones a planetas exteriores se han empleado sistemas de radioisótopos (RPS) para generar potencia eléctrica en los vehículos espaciales y en los rovers de exploración. Estos sistemas emplean como fuente de energía el escaso y costoso plutonio-238. La NASA, por medio de un informe de la National Academy of Science (5 de Mayo del 2009), expresó una profunda preocupación por la baja cantidad de plutonio almacenado, insuficiente para desarrollar todas las misiones de exploración planetaria planeadas en el futuro [81, 91]. Esta circustancia ha llevado a dicha Agencia tomar la decisión de limitar el uso de estos sistemas RPS en algunas misiones de especial interés científico y una recomendación de alta prioridad para que el Congreso de los EEUU apruebe el reestablecimiento de la producción de plutonio-238, -son necesarios cerca de 5 kg de este material radiactivo al año-, para salvaguardar las misiones que requieran dichos sistemas de potencia a partir del año 2018. Por otro lado, la Agencia estadounidense ha estado considerando el uso de fuentes de energía alternativa; como la fisión nuclear a través del ambicioso proyecto Prometheus, para llevar a cabo una misión de exploración en el sistema jovial (JIMO). Finalmente, dicha misión fue desestimada por su elevado coste. Recientemente se han estado desarrollando sistemas que consigan energía a través de los recursos naturales que nos aporta el Sol, mediante paneles solares -poco eficientes para misiones a planetas alejados de la luz solar-. En este contexto, la misión JUNO del programa Nuevas Fronteras de la NASA, cuyo lanzamiento fue realizado con éxito en Agosto de 2011, va a ser la primera misión equipada con paneles solares que sobrevolará Júpiter en el 2015 siguiendo una órbita polar. Anteriormente se habían empleado los antes mencionados RPS para las misiones Pioneer 10,11, Voyager 1,2, Ulysses, Cassini-Huygens y Galileo (todas sobrevuelos excepto Galileo). Dicha misión seguirá una órbita elíptica de alta excentricidad con un periápside muy cercano a Júpiter, y apoápside lejano, evitando que los intensos cinturones de radiación puedan dañar los instrumentos de navegación y científicos. Un tether o amarra electrodinámica es capaz de operar como sistema propulsivo o generador de potencia, pero también puede ser considerado como solución científicotecnológica en misiones espaciales tanto en LEO (Órbita Baja Terrestre) como en planetas exteriores. Siguiendo una perspectiva histórica, durante las misiones terrestres TSS-1 (1992) y TSS-1R (1996) se emplearon amarras estandard con recubrimiento aislante en toda su longitud, aplicando como terminal anódico pasivo un colector esférico para captar electrones. En una geometría alternativa, propuesta por J. R. Sanmartín et al. (1993) [93], se consideró dejar la amarra sin recubrimiento aislante (“bare tether”), y sin colector anódico esférico, de forma que recogiera electrones a lo largo del segmento que resulta polarizado positivo, como si se tratara de una sonda de Langmuir de gran longitud. A diferencia de la amarra estandard, el “bare tether” es capaz de recoger electrones a lo largo de una superficie grande ya que este segmento es de varios kilómetros de longitud. Como el radio de la amarra es del orden de la longitud de Debye y pequeño comparado con el radio de Larmor de los electrones, permite una recolección eficiente de electrones en el régimen OML (Orbital Motion Limited) de sondas de Langmuir. La corriente dada por la teoría OML varía en función del perímetro y la longitud. En el caso de una cinta delgada, el perímetro depende de la anchura, que debe ser suficientemente grande para evitar cortes producidos por debris y micrometeoritos, y suficientemente pequeño para que la amarra funcione en dicho régimen [95]. En el experimento espacial TSS-1R mencionado anteriormente, se identificó una recolección de corriente más elevada que la que predecía el modelo teórico de Parker- Murphy, debido posiblemente a que se utilizaba un colector esférico de radio bastante mayor que la longitud de Debye [79]. En el caso de una amarra “bare”, que recoge electrones a lo largo de gran parte de su longitud, se puede producir un fenómeno conocido como atrapamiento adiabático de electrones (adiabatic electron trapping) [25, 40, 60, 73, 74, 97]. En el caso terrestre (LEO) se da la condición mesotérmica en la que la amarra se mueve con una velocidad muy superior a la velocidad térmica de los iones del ambiente y muy inferior a la velocidad térmica de los electrones. J. Laframboise y L. Parker [57] mostraron que, para una función de distribución quasi-isotrópica, la densidad de electrones debe entonces ser necesariamente inferior a la densidad ambiente. Por otra parte, debido a su flujo hipersónico y a la alta polarización positiva de la amarra, la densidad de los iones es mayor que la densidad ambiente en una vasta región de la parte “ram” del flujo, violando la condición de cuasi-neutralidad,-en una región de dimensión mayor que la longitud de Debye-. La solución a esta paradoja podría basarse en el atrapamiento adiabático de electrones ambiente en órbitas acotadas entorno al tether. ABSTRACT New technological and scientific applications by electrodynamic tethers for planetary missions are analyzed: i) A set of cylindrical, parallel tethers (electric solar sail or e-sail) is considered for an interplanetary mission; ions from the solar wind are repelled by the high potential of the tether, providing momentum to the e-sail. An approximated model of a stationary potential for a high solar wind flow is considered. With the force provided by a negative biased tether, an indirect method for the optimization trajectory of an Earth-to-Jupiter orbit transfer is analyzed. ii) The deployment of a tether from the e-sail allows several scientific applications in Jupiter. iia) It might be used as a source of radiative waves for plasma diagnostics and artificial aurora generator. A conductive tether orbiting in the Jovian magnetosphere produces waves. Wave radiation by a conductor carrying a steady current in both a polar, highly eccentric, low perijove orbit, as in NASA’s Juno mission, and an equatorial low Jovian orbit (LJO) mission below the intense radiation belts, is considered. Both missions will need electric power generation for scientific instruments and communication systems. Tethers generate power more efficiently than solar panels or radioisotope power systems (RPS). The radiation impedance is required to determine the current in the overall tether circuit. In a cold plasma model, radiation occurs mainly in the Alfven and fast magnetosonic modes, exhibiting a large refraction index. The radiation impedance of insulated tethers is determined for both modes and either mission. Unlike the Earth ionospheric case, the low-density, highly magnetized Jovian plasma makes the electron gyrofrequency much larger than the plasma frequency; this substantially modifies the power spectrum for either mode by increasing the Alfven velocity. An estimation of the radiation impedance of bare tethers is also considered. iib) In LJO, a spacecraft orbiting in a slow downward spiral under the radiation belts would allow determining magnetic field structure and atmospheric composition for understanding the formation, evolution, and structure of Jupiter. Additionally, if the cathodic contactor is switched off, a tether floats electrically, allowing e-beam emission that generate auroras. On/off switching produces bias/current pulses and signal emission, which might be used for Jovian plasma diagnostics. In LJO, the ions impacting against the negative-biased tether do produce secondary electrons, which racing down Jupiter’s magnetic field lines, reach the upper atmosphere. The energetic electrons there generate auroral effects. Regions where the tether efficiently should produce secondary electrons are analyzed. iic) Other scientific application suggested in LJO is the in-situ detection of charged grains. Charged grains naturally orbit near Jupiter. High-energy electrons in the Jovian ambient may be modeled by the kappa distribution function. In complex plasma scenarios, where the Jovian high electric field may accelerate charges up superthermal velocities, the use of non-Maxwellian distributions should be considered. In these cases, the distribution tails fit well to a power-law dependence for electrons. Fluctuations of the charged grains for non-Mawellian distribution function are here studied. iii) The present thesis is concluded with the analysis for de-orbiting satellites at end of mission by electrodynamic tethers. A de-orbit tether system must present very small tether-to-satellite mass ratio and small probability of a tether cut by small debris too. The present work shows how to select tape dimensions so as to minimize the product of those two magnitudes. Preliminary results of tape-tether design are here discussed to minimize that function. Results for de-orbiting Cryosat and Envisat are also presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Juno, the second mission in the NASA New Frontiers Program, will both be a polar Jovian orbiter, and use solar arrays for power, moving away from previous use of radioisotope power systems (RPSs) in spite of the weak solar light reaching Jupiter. The power generation at Jupiter is critical, and a conductive tether could be an alternative source of power. A current-carrying tether orbiting in a magnetized ionosphere/plasmasphere will radiate waves. A magnitude of interest for both power generation and signal emission is the wave impedance. Jupiter has the strongest magnetic field in the Solar Planetary System and its plasma density is low everywhere. This leads to an electron plasma frequency smaller than the electron cyclotron frequency, and a high Alfven velocity. Unlike the low Earth orbit (LEO) case, the electron skin depth and the characteristic size of plasma contactors affect the Alfven impedance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wave radiation by a conductor carrying a steady current in both a polar, highly eccentric, low perijove orbit, as in NASA's planned Juno mission, and an equatorial low Jovian orbit (LJO) mission below the intense radiation belts, is considered. Both missions will need electric power generation for scientific instruments and communication systems. Tethers generate power more efficiently than solar panels or radioisotope power systems (RPS). The radiation impedance is required to determine the current in the overall tether circuit. In a cold plasma model, radiation occurs mainly in the Alfven and fast magnetosonic modes, exhibiting a large refraction index. The radiation impedance of insulated tethers is determined for both modes and either mission. Unlike the Earth ionospheric case, the low-density, highly magnetized Jovian plasma makes the electron gyrofrequency much larger than the plasma frequency; this substantially modifies the power spectrum for either mode by increasing the Alfven velocity. Finally, an estimation of the radiation impedance of bare tethers is considered. In LJO, a spacecraft orbiting in a slow downward spiral under the radiation belts would allow determining magnetic field structure and atmospheric composition for understanding the formation, evolution, and structure of Jupiter. Additionally, if the cathodic contactor is switched off, a tether floats electrically, allowing e-beam emission that generate auroras. On/off switching produces bias/current pulses and signal emission, which might be used for Jovian plasma diagnostics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As expectativas da Organização Mundial de Saúde para o ano de 2030 são que o número de mortes por câncer seja de aproximadamente 13,2 milhões, evidenciando a elevada parcela desta doença no problema de saúde mundial. Com relação ao câncer de próstata, de acordo com o Instituto Nacional do Câncer, o número de casos diagnosticados no mundo em 2012 foi de aproximadamente 1,1 milhão, enquanto que no Brasil os dados indicam a incidência de 68 mil novos casos. O tratamento deste tipo de neoplasia pode ser realizado com cirurgia (prostatectomia) ou radioterapia. Dentre a radioterapia, podemos destacar a técnica de braquiterapia, a qual consiste na introdução (implante) de pequenas fontes radioativas (sementes) no interior da próstata, onde será entregue um valor elevado de dose no volume de tratamento e baixa dose nos tecidos ao redor. No Brasil, a classe médica estima uma demanda de aproximadamente 8000 sementes/mês, sendo o custo unitário de cada semente de pelo menos U$ 26,00. A Associação Americana de Físicos na Medicina publicou alguns documentos descrevendo quais parâmetros e análises devem ser realizadas para avaliações da distribuição de dose, como por exemplo, os parâmetros Constante de taxa de dose, Função radial e Função de anisotropia. Estes parâmetros podem ser obtidos através de medidas experimentais da distribuição de dose ou por simulações computacionais. Neste trabalho foram determinados os parâmetros dosimétricos da semente OncoSeed-6711 da empresa Oncura-GEHealthcare e da semente desenvolvida pelo Grupo de Dosimetria de Fontes de Braquiterapia do Centro de Tecnologia das Radiações (CTR IPEN-CNEN/SP) por simulação computacional da distribuição de dose utilizando o código MCNP5, baseado no Método de Monte Carlo. A semente 6711 foi modelada, assim como um sistema dosimétrico constituído por um objeto simulador cúbico de 30x30x30 cm3 preenchido com água. Os valores obtidos da semente 6711 foram comparados com alguns apresentados na literatura, onde o parâmetro Constante de taxa de dose apresentou erro relativo em relação ao valor publicado no TG- 43 de 0,1%, sendo que os outros parâmetros analisados também apresentaram boa concordância com os valores publicados na literatura. Deste modo, pode-se considerar que os parâmetros utilizados nas simulações (espectro, modelagem geométrica e avaliação de resultados) estão compatíveis com outros estudos, sendo estes parâmetros também utilizados nas simulações da semente do IPEN. Considerando as análises de incerteza estatística, os valores obtidos da semente do IPEN são semelhantes aos valores da semente 6711.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Medidas de espectroscopia gama de alta resolução têm diversas aplicações. Aplicações envolvendo medidas de radioisótopos de meia-vida curta podem apresentar problemas de baixa precisão nas contagens quando a fonte radioativa está distante do detector e de perda de acurácia por efeitos de tempo morto e empilhamento de pulsos em situação de altas taxas de contagens. Um modo de minimizar esses problemas é alterando a posição da fonte radioativa durante o processo de medição, aproximando-a do detector conforme sua atividade diminui e assim maximizando o número de contagens medidas. Neste trabalho, foi desenvolvido o Movimentador de Amostras Radioativas Automatizado (MARA), um aparato de baixo custo, feito com materiais de baixo número atômico e leve, projetado e construído para auxiliar nas medidas de espectroscopia gama, capaz de controlar a distância entre a fonte e o detector, permitindo inclusive que ocorra alteração dessa distância durante o processo de medição. Por ser automatizado ele otimiza o tempo do operador, que tem total liberdade para criar suas rotinas de medidas no dispositivo, além de evitar que o mesmo tome uma parcela da dose radioativa. Foi também feita uma interface que permite controle do MARA e a programação do sistema de aquisição de dados. Foram realizados testes para otimização da operação do sistema MARA e foi verificada a segurança de operação do MARA, não apresentando nenhuma falha durante seus testes. Foi aplicado o teste de repetitividade, por meio de medições com uma fonte calibrada de 60Co, e verificou-se que o sistema de movimentação de prateleiras automatizado reproduziu os resultados do sistema estático com confiabilidade de 95%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A deficiência de Zn no solo causa efeitos indesejáveis na produção agrícola, pois a baixa disponibilidade deste micronutriente para as plantas promove a diminuição da atividade enzimática, além da deficiência deste elemento na alimentação, que pode levar ao estado de subnutrição. Tendo em vista a problemática do Zn no sistema solo-planta e suas variações nos compartimentos do solo, é importante a avaliação de sua fitodisponibilidade e as frações do solo que este elemento está associado. O objetivo deste trabalho foi avaliar a fitodisponibilidade e a compartimentalização de Zn no solo, para as culturas de arroz (Oryza sativa L.) e soja (Glycine max L. Merrill) e avaliar o efeito das doses de Zn sobre a nutrição e exportação deste nutriente pela cultura. Utilizou-se como plantas teste as culturas de arroz e soja para avaliar o efeito das doses de Zn sobre a nutrição e translocação deste nutriente até os grãos. Para tanto, uma amostra de um Latossolo Vermelho, textura argilosa da região de Piracicaba (SP) foi utilizada e ZnCl2 (marcado com 65Zn) como fonte. O experimento foi conduzido em casa de vegetação em DIC, com cinco doses de Zn (0, 1, 2, 4 e 8 mg kg-1 de solo), com quatro repetições. O experimento foi conduzido até a formação de grãos e foi realizada determinação de Zn por Espectrômetria de Absorção Atômica após digestão nitroperclórica e contagem do 65Zn nas partes da planta: parte aérea (PA) e panícula (P), para arroz e PA, vagem (V) e grão (G), para soja. Calculou-se a quantidade de Zn proveniente da fonte (Znpf) nas partes das plantas e o aproveitamento do Zn da fonte pelas culturas (Ap). Nas amostras de solo foram realizadas extrações por DTPA (ZnDTPA) e Mehlich-1 (ZnM1) em duas subamostragens (t1 e t2), antes da semeadura e florescimento, respectivamente. O fracionamento de Zn foi realizado em amostras de t2 nas frações: trocável (ZnTroc); ligado a carbonatos (ZnCarb); a matéria orgânica (ZnMO); a óxidos (ZnOxi) e residual (Znres). Adicionalmente, foi realizada análise do teor pseudo-total de Zn (ZnPST). Os dados obtidos foram submetidos à análise de variância pelo teste-F a 95 % de probabilidade, ajuste das variáveis em função das doses por regressões e teste de média e análises de correlações entre as principais variáveis respostas. O Zn acumulado total na planta se ajustou à regressão linear em função do aumento das doses, entretanto ao analisar as partes separadamente, só houve diferença entre as doses para a variável PA em ambas as culturas. O Znpf total nas plantas apresentou incremento com a adição das doses crescentes de Zn ao solo, entretanto, eu aproveitamento foi baixo, 12 e 8,75 % para arroz e soja, respectivamente. As doses de ZnCl2 adicionadas ao solo, aumentaram a concentração de Zn presente nas frações ZnTroc > ZnMO > ZnCarb, em ordem decrescente. O Zn total acumulado nas plantas de arroz e soja apresentam correlações crescentes para os extratores DTPA e M1 nas duas subamostragens (t1 e t2), em função das doses avaliadas. O Zn extraído pelo DTPA ou M1, apresentaram correlação significativa com o Zn extraído nas frações, na ordem decrescente, ZnTroc > ZnCarb > ZnMO

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neste trabalho foram desenvolvidos detectores de radiação Barreira de superfície de silício que fossem capazes de detectar a presença da radiação gama de baixa energia proveniente de sementes de iodo-125 utilizada em tratamentos de braquiterapia. A partir de substratos comerciais de silício foram desenvolvidos os detectores, de uma sequência que partiu de tratamentos químicos nas superfícies destes substratos com a intenção de minimizar os possíveis ruídos gerados, validação das amostras obtidas como diodos, assegurando características detectoras, e a efetiva utilização como detector para fontes radioativas de iodo-125 com energia em torno de 25 kev e amerício-251 com energia na ordem de 59 kev. Finalizou realizando a análise dos espectros de energia obtidos e assim foi possível observar a capacidade destes detectores para mensuração da energia proveniente destas sementes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O sistema microPET/CT é um importante equipamento utilizado nas pesquisas de imagem diagnóstica em pequenos animais. O radiofármaco mais usado nesta tecnologia é o fluordeoxiglicose marcado com flúor-18. Este estudo tem como objetivo efetuar o controle radiológico no laboratório de pesquisa microPET/CT do Centro de Radiofarmácia do IPEN-CNEN/SP, de forma a satisfazer tanto as normas nacionais como as recomendações internacionais. O laboratório está classificado pela equipe de radioproteção da instalação como área supervisionada, nas quais embora não seja obrigatória a adoção de medidas específicas de proteção e segurança, devem ser submetidas reavaliações regulares das condições do ambiente de trabalho. Visando assegurar a proteção radiológica dos trabalhadores diretamente envolvidos no manuseio do equipamento, realizou-se o monitoramento do local de trabalho e a avaliação do controle de dose individual. Inicialmente foi feito o monitoramento pré-operacional, isto é, o levantamento radiométrico no laboratório. Além disso, mediu-se nível de radiação externa nas instalações do laboratório e suas adjacências, por meio da colocação de nove dosímetros termoluminescentes (TL) de CaSO4:Dy, em locais previamente selecionados. Os indivíduos ocupacionalmente expostos foram avaliados mensalmente por meio do uso de dosímetros TL posicionados no tórax e por medidas de corpo inteiro, tomadas a cada seis meses. O período do estudo foi de dois anos, com início em abril de 2014. Para o controle do microPET/CT realizou-se testes de desempenho de acordo com o protocolo padrão do equipamento e em conformidade com a norma desenvolvida pela força tarefa para estudos com PET em animais Animal PET Standard Task Force. O presente estudo permitiu demonstrar que os níveis de radiação das áreas (estimativas de dose ambiente e dose efetiva), assim como a blindagem do equipamento estão adequados de acordo com os limites da exposição ocupacional. Ressalta-se a importância de se seguir rigorosamente os princípios de radioproteção, já que se trata de pesquisas com fontes radioativas não seladas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A detector based on doped silica and optical fibers was developed to monitor the profile of particle accelerator beams of intensity ranging from 1 pA to tens of µA. Scintillation light produced in a fiber moving across the beam is measured, giving information on its position, shape and intensity. The detector was tested with a continuous proton beam at the 18 MeV Bern medical cyclotron used for radioisotope production and multi-disciplinary research. For currents from 1 pA to 20 µA, Ce3+ and Sb3+ doped silica fibers were used as sensors. Read out systems based on photodiodes, photomultipliers and solid state photomultipliers were employed. Profiles down to the pA range were measured with this method for the first time. For currents ranging from 1 pA to 3 µA, the integral of the profile was found to be linear with respect to the beam current, which can be measured by this detector with an accuracy of ∼1%. The profile was determined with a spatial resolution of 0.25 mm. For currents ranging from 5 µA to 20 µA, thermal effects affect light yield and transmission, causing distortions of the profile and limitations in monitoring capabilities. For currents higher than ∼1 µA, non doped optical fibers for both producing and transporting scintillation light were also successfully employed.