1000 resultados para Radiografia - Qualidade de imagem


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Ciências Odontológicas - FOAR

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Biologia Geral e Aplicada - IBB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The signal-to-noise ratio and image uniformity analysis parameters are very important in quality control of an MRI scanner. They are measured in regular tests with phantoms. In these tests, however, used to quadrature coil, which has been most widely used clinically, and, therefore, was replaced in the procedures for body coil. In order to understand the difference between these two parameters in these coils, the study aimed to analyze the images acquired from four different phantoms in the same equipment under the same conditions for comparison purposes. With these results, it can be concluded that the body coil signal-to-noise ratio has always smaller than the quadrature in any projection, whereas the image uniformity is larger

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The computed tomography, devised by Godfrey Hounsfield and Allan Cormack, is in its fourth decade of the clinical use and has presented to be a very useful tool in the diagnosis of several pathologies. For this reason, its use is increasing each day, due to technological progress since its creation. Due to be more and more utilized, the equipment must be in good operating conditions, because it is subject to variance and wearing, damage the quality of diagnosis. To evaluate whether the performance of the scanner remains constant along the time and the dose received by the patient is within the desired limits, periodic tests of quality control must be performed. For this subject, the regulation 453 (June 01, 1998) was created, which determines the need of the implementation of a program for quality assurance (PGQ), where, in addition to the tests of quality control, are established the necessary measurements for the proper functioning of the equipment, generating a trustworthy diagnosis, reducing the dose for the patient and the costs. In this document, are presented tests of quality control carried out in hospitals of the city of Sao Paulo carried out together with the Technical Section of Applications by Imaging Diagnostic (STADI) of the Institute of Electrotechnics and Energy of the University of São Paulo (IEE/USP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper considers a study of the anatomical features of the cardiac system and a three-dimensional model of the different tunics that comprise the heart wall, for processing and quality control of radiological images. The structures are built by the layer overlapping method, where a layer can be understood as a slice of the three-dimensional object. The pericardium, myocardium and endocardium were represented with three-dimensional cylinders and hexagons. The spatial arrangement of the cardiac system is determined by an background image of a real model, which values are defined according to the shape of the region and on the anatomical patients characteristics. The results are significant, considering the anatomical structures details, as well as the representation of the thicknesses of the regions of the heart wall. The validation of the anatomical model was accomplished through comparisons with dimensions obtained from a real model and allows verifying that the model is appropriate. The degree of representation will allow the verification of the influence of radiological parameters, morphometric peculiarities and stage of the diseases on the quality of the images, as well as on the performance of the Computer-Aided Diagnosis (CAD).