998 resultados para Pressure recommended


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Left ventricular hypertrophy following volume overload is regarded as an example of cardiac remodeling without increased fibrosis accumulation. However, infarction is associated with increased fibrosis within the noninfarcted, hypertrophied myocardium, particularly in the subendocardial regions. It is conceivable to suppose that, as also occurs postinfarction, low coronary driving pressure may also interfere with accumulation of myocardial fibrosis following aortocaval fistula. PURPOSE: To investigate the role of acute hemodynamic changes in subsequent deposition of cardiac fibrosis in response to aortocaval fistula. METHOD: Aortocaval fistula were created in 4 groups of Wistar rats that were followed over 4 and 8 weeks: aortocaval fistula 4 and aortocaval fistula 8 (10 rats each) and their respective controls (sham-operated controls - Sh), Sh4 and Sh8 (8 rats each). Hemodynamic measurements were performed 1 week after surgery. Hypertrophy and fibrosis were quantified by myocyte diameter and collagen volume fraction at the end of follow up. RESULT: Compared with Sh4 and Sh8, pulse pressure, left ventricular end-diastolic pressure, and +dP/dt were higher in aortocaval fistula 4 and aortocaval fistula 8, but -dP/dt was similar. Coronary driving pressure (mm Hg), used as an estimate of perfusion pressure, was lower in aortocaval fistula 8 (52.6 ± 4.1) than in Sh8 (100.8 ± 1.3), but comparable between aortocaval fistula 4 (50.0 ± 8.9) and Sh4 (84.8 ± 2.3). Myocyte diameter was greater in aortocaval fistula 8, whereas interstitial and subendocardial fibrosis were greater in aortocaval fistula 4 and aortocaval fistula 8. Coronary driving pressure correlated inversely and independently with subendocardial fibrosis (r² = .86, P <.001), whereas left ventricular systolic pressure (r² = 0.73, P = .004) and end-diastolic pressure (r² = 0.55, P = 012) correlated positively and independently with interstitial fibrosis. CONCLUSION: Coronary driving pressure falls and ventricular pressures increase early after aortocaval fistula and are associated with subsequent myocardial fibrosis deposition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work is to develop an operational tool to analyze exchange rate pressure in the context of Angola. The Angolan economy exhibits a number of relevant characteristics: a closed financial account, a partially controlled current account, a highly dollarized economy and exports (oil) price determined in World markets. These features have a direct effect on the demand of foreign currency and motivate their inclusion in the specification of a model for Angola. The model provides the rational for a measure of an exchange market rate pressure (EMP) index that contains exports changes, imports changes, the foreign interest rate and inflation and the change in foreign reserves corrected for a measure dollarization. The empirical performance new measure is comparable (slightly better) to the performance of the EMP indexes obtained in Eichengreen Rose and Wyplosz (1994) and Klassen and Jager (2011).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Barotrauma is identified as one of the leading diseases in Ventilated Patients. This type of problem is most common in the Intensive Care Units. In order to prevent this problem the use of Data Mining (DM) can be useful for predicting their occurrence. The main goal is to predict the occurence of Barotrauma in order to support the health professionals taking necessary precautions. In a first step intensivists identified the Plateau Pressure values as a possible cause of Barotrauma. Through this study DM models (classification) where induced for predicting the Plateau Pressure class (>=30 cm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento Ciência e Engenharia de Polímeros e Compósitos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genome-wide studies of African populations have the potential to reveal powerful insights into the evolution of our species, as these diverse populations have been exposed to intense selective pressures imposed by infectious diseases, diet, and environmental factors. Within Africa, the Sahel Belt extensively overlaps the geographical center of several endemic infections such as malaria, trypanosomiasis, meningitis, and hemorrhagic fevers. We screened 2.5 million single nucleotide polymorphisms in 161 individuals from 13 Sahelian populations, which together with published data cover Western, Central, and Eastern Sahel, and include both nomadic and sedentary groups. We confirmed the role of this Belt as a main corridor for human migrations across the continent. Strong admixture was observed in both Central and Eastern Sahelian populations, with North Africans and Near Eastern/Arabians, respectively, but it was inexistent in Western Sahelian populations. Genome-wide local ancestry inference in admixed Sahelian populations revealed several candidate regions that were significantly enriched for non-autochthonous haplotypes, and many showed to be under positive selection. The DARC gene region in Arabs and Nubians was enriched for African ancestry, whereas the RAB3GAP1/LCT/MCM6 region in Oromo, the TAS2R gene family in Fulani, and the ALMS1/NAT8 in Turkana and Samburu were enriched for non-African ancestry. Signals of positive selection varied in terms of geographic amplitude. Some genomic regions were selected across the Belt, the most striking example being the malaria-related DARC gene. Others were Western-specific (oxytocin, calcium, and heart pathways), Eastern-specific (lipid pathways), or even population-restricted (TAS2R genes in Fulani, which may reflect sexual selection).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Mecânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Contabilidade

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Civil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the fabrication process and characterization of a flexible pressure sensor based on polydimethylsiloxane (PDMS) and multi-walled carbon nanotubes (CNT-PDMS). The proposed approach relies on patterned CNT-PDMS nanocomposite strain gauges fabricated with SU-8 microstructures (with the micropatterns) in a low‑cost and simple fabrication process. This nanocomposite polymer is mounted over a PDMS membrane, which, in turn, lies on top of a PDMS diaphragm like structure. This configuration enables the PDMS membrane to bend when pressure is applied, thereby affecting the nanocomposite strain gauges, effectively changing their electrical resistance. Carbon nanotubes have several advantages such as excellent mechanical properties, high electrical conductivity and thermal stability. Furthermore, the measurement range of the proposed sensor can be adapted according to the application by varying the CNTs content and geometry of microstructure. In addition, the sensor’s biocompatibility, low cost and simple fabrication makes it very appealing for biomechanical strain sensing. The sensor’s sensitivity was about 0.073%ΔR/mmHg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on an innovative approach to measuring intraluminal pressure in the upper gastrointestinal (GI) tract, especially monitoring GI motility and peristaltic movements. The proposed approach relies on thin-film aluminum strain gauges deposited on top of a Kapton membrane, which in turn lies on top of an SU-8 diaphragm-like structure. This structure enables the Kapton membrane to bend when pressure is applied, thereby affecting the strain gauges and effectively changing their electrical resistance. The sensor, with an area of 3.4 mm2, is fabricated using photolithography and standard microfabrication techniques (wet etching). It features a linear response (R2 = 0.9987) and an overall sensitivity of 2.6 mV mmHg−1. Additionally, its topology allows a high integration capability. The strain gauges’ responses to pressure were studied and the fabrication process optimized to achieve high sensitivity, linearity, and reproducibility. The sequential acquisition of the different signals is carried out by a microcontroller, with a 10-bit ADC and a sample rate of 250 Hz. The pressure signals are then presented in a user-friendly interface, developed using the Integrated Development Environment software, QtCreator IDE, for better visualization by physicians.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surveying the evolution of blood pressure (BP) levels and hypertension (HTN) prevalence is important. A stringent strategy was utilized in a population cohort study. The BP was measured at two visits at least 3 months apart, and the results were analyzed using the following two methods: the Surveillance method (three BP measurements were performed in one visit, and the results were compared with those published previously for the identical method) and the Clinical method (three measurements per visit for two visits, and the concordant results in both visits were used to determine the BP classification). A total of 2542 subjects completed the evaluation. Using the Clinical method, an average systolic/diastolic BP value of 129.8/76.8?mm?Hg was obtained, and the prevalence of HTN was 31.6%. Of the hypertensive patients, 74.3% were aware of his/her condition; 69.1% were treated and 40.8% of those treated had adequate BP control. A total of 24.7% of subjects changed his/her BP classification between visits, and 13.7% misreported HTN. Using the Surveillance method, we determined that the average global SBP has been maintained, with HTN prevalence increasing in this region, drifting from reported trends nationally and worldwide. There has been improvement in the proportion of treated and controlled subjects; however, the Surveillance method overestimated the HTN prevalence and underestimated the proportion of treated and controlled subjects. The BP levels were higher than observed worldwide in high-cardiovascular (CV) risk countries as well as higher than the minimum risk exposure level for developing CV disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The focus of this paper is given to investigate the effect of different fibers on the pore pressure of fiber reinforced self-consolidating concrete under fire. The investigation on the pore pressure-time and temperature relationships at different depths of fiber reinforced self-consolidating concrete beams was carried out. The results indicated that micro PP fiber is more effective in mitigating the pore pressure than macro PP fiber and steel fiber. The composed use of steel fiber, micro PP fiber and macro PP fiber showed clear positive hybrid effect on the pore pressure reduction near the beam bottom subjected to fire. Compared to the effect of macro PP fiber with high dosages, the effect of micro PP fiber with low fiber contents on the pore pressure reduction is much stronger. The significant factor for reduction of pore pressure depends mainly on the number of PP fibers and not only on the fiber content. An empirical formula was proposed to predict the relative maximum pore pressure of fiber reinforced self-consolidating concrete exposed to fire by considering the moisture content, compressive strength and various fibers. The suggested model corresponds well with the experimental results of other research and tends to prove that the micro PP fiber can be the vital component for reduction in pore pressure, temperature as well spalling of concrete.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: A double-blind, placebo-controlled multicenter study involving 34 centers from different Brazilian regions was performed to evaluate the antihypertensive efficacy and tolerability of trandolapril, an angiotensin I converting enzyme inhibitor, in the treatment of mild-to-moderate systemic arterial hypertension. METHODS: Of 262 patients enrolled in this study, 127 were treated with trandolapril 2 mg/day for 8 consecutive weeks, and the remaining 135 patients received placebo for the same period of time. Reduction in blood pressure (BP) and the occurrence of adverse events during this period were evaluated in both groups. RESULTS: Significant reductions in both systolic and diastolic pressures were observed in patients treated with trandolapril when compared with those on placebo. Antihypertensive efficacy was achieved in 57.5% of the patients on trandolapril and in 42% of these normal values of BP were obtained. The efficacy of trandolapril was similar in all centers, regardless of the area of the country. In a subset of 30 patients who underwent ABPM, responders showed a significant hypotensive effect to trandolapril throughout the 24 hour day. The adverse event profile was similar in both trandolapril and placebo groups. CONCLUSION: Our results demonstrate, for the first time in a large group of hypertensive patients from different regions in Brazil, good efficacy and tolerability of trandolapril during treatment of mild-to-moderate essential systemic hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the effects of the elevation of the left ventricular end-diastolic pressure (LVEDP) on the value of the 1st temporal derivative of the ventricular pressure (dP/dt). METHODS: Nineteen anesthetized dogs were studied. The dogs were mechanically ventilated and underwent thoracotomy with parasympathetic nervous system block. The LVEDP was controlled with the use of a perfusion circuit connected to the left atrium and adjusted to the height of a reservoir. The elevation of the LVEDP was achieved by a sudden increase in the height of a reservoir filled with blood. Continuous recordings of the electrocardiogram, the aortic and ventricular pressures and the dP/dt were performed. RESULTS: Elevation of the LVEDP did not result in any variation of the heart rate (167±16.0bpm, before the procedure; 167±15.5bpm, after the procedure). All the other variables assessed, including systolic blood pressure (128±18.3mmHg and 150±21.5mmHg), diastolic blood pressure (98±16.9mmHg and 115±19.8mmHg), LVEDP (5.5±2.49 and 9.3±3.60mmHg), and dP/dt (4,855 ± 1,082 mmHg/s and 5,149±1,242mmHg/s) showed significant increases following the expansion of the ventricular cavity. Although the elevation of the dP/dt was statistically significant, 6 dogs curiously showed a decrease in the values of dP/dt. CONCLUSION: Sudden elevation of the LVEDP resulted in increased values of dP/dt; however, in some dogs, this response was not uniform.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine if abnormal laboratory findings are more common in individuals with hypertension and in those with other risk factors, such as obesity, smoking and alcohol ingestion. METHODS: A study was carried out in the general outpatient clinics of a university hospital (145 individuals without previous diagnosis of hypertension) and the following variables were assessed: high blood pressure (as defined by the VI Joint National Committee on Prevention, Detection and Treatment of High Blood Pressure - VI JNC), obesity [calculated using body mass index (BMI)], tobacco use, and alcoholic ingestion. The laboratory examinations consisted of the following tests: hemogram, glycemia, uric acid, potassium, total/HDL-fraction cholesterol, triglycerides, calcium and creatinine. RESULTS: High blood pressure was not associated with a higher number of abnormal laboratory tests. Hypertensive individuals with a BMI > or = 25kg/m² or normotensive obese individuals, however, had a higher frequency of diabetes (12X), hypertriglyceridemia (3X), and hypercholesterolemia (2X), as compared with hypertensive individuals with BMI <25kg/m² and preobese/normal weight normotensive individuals. CONCLUSION: High blood pressure is not associated with a higher frequency of abnormal laboratory tests. The association of high blood pressure and obesity, however, increases the detection of diabetes and dyslipidemias.