987 resultados para Pressure measurement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Positional therapy that prevents patients from sleeping supine has been used for many years to manage positional obstructive sleep apnea (OSA). However, patients' usage at home and the long term efficacy of this therapy have never been objectively assessed. METHODS: Sixteen patients with positional OSA who refused or could not tolerate continuous positive airway pressure (CPAP) were enrolled after a test night study (T0) to test the efficacy of the positional therapy device. The patients who had a successful test night were instructed to use the device every night for three months. Nightly usage was monitored by an actigraphic recorder placed inside the positional device. A follow-up night study (T3) was performed after three months of positional therapy. RESULTS: Patients used the device on average 73.7 ± 29.3% (mean ± SD) of the nights for 8.0 ± 2.0 h/night. 10/16 patients used the device more than 80% of the nights. Compared to the baseline (diagnostic) night, mean apnea-hypopnea index (AHI) decreased from 26.7 ± 17.5 to 6.0 ± 3.4 with the positional device (p<0.0001) during T0 night. Oxygen desaturation (3%) index also fell from 18.4 ± 11.1 to 7.1 ± 5.7 (p = 0.001). Time spent supine fell from 42.8 ± 26.2% to 5.8 ± 7.2% (p < 0.0001). At three months (T3), the benefits persisted with no difference in AHI (p = 0.58) or in time spent supine (p = 0.98) compared to T0 night. The Epworth sleepiness scale showed a significant decrease from 9.4 ± 4.5 to 6.6 ± 4.7 (p = 0.02) after three months. CONCLUSIONS: Selected patients with positional OSA can be effectively treated by a positional therapy with an objective compliance of 73.7% of the nights and a persistent efficacy after three months.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Plutonium and americium are radionuclides particularly difficult to measure in environmental samples because they are alpha-emitters and therefore necessitate a careful separation before any measurement, either using radiometric methods or ICP-SMS. Recent developments in extraction chromatography resins such as Eichrom (R) TRU and TEVA have resolved many of the analytical problems but drawbacks such as low recovery and spectral interferences still occasionally occur. Here, we report on the use of the new Eichrom (R) DGA resin in association with TEVA resin and high pressure microwave acid leaching for the sequential determination of plutonium and americium in environmental samples. The method results in average recoveries of 83 +/- 15% for plutonium and 73 +/- 22% for americium (n = 60), and a less than 10% deviation from reference values of four IAEA reference materials and three samples from intercomparisons exercises. The method is also suitable for measuring Pu-239 in water samples at the mu Bq/l level, if ICP-SMS is used for the measurement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Raltegravir (RAL), maraviroc (MVC), darunavir (DRV), and etravirine (ETV) are new antiretroviral agents with significant potential for drug interactions. This work describes a sensitive and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of plasma drug levels. Single-step extraction of RAL, MVC, DRV, ETV and RTV from plasma (100 microl) is performed by protein precipitation using 600 microl of acetonitrile, after the addition of 100 microl darunavir-d(9) (DRV-d(9)) at 1000 ng/ml in MeOH/H(2)O 50/50 as internal standard (I.S.). The mixture is vortexed, sonicated for 10 min, vortex-mixed again and centrifuged. An aliquot of supernatant (150 microl) is diluted 1:1 with a mixture of 20 mM ammonium acetate/MeOH 40/60 and 10 microl is injected onto a 2.1 x 50 mm Waters Atlantis-dC18 3 microm analytical column. Chromatographic separations are performed using a gradient program with 2 mM ammonium acetate containing 0.1% formic acid and acetonitrile with 0.1% formic acid. Analytes quantification is performed by electrospray ionisation-triple quadrupole mass spectrometry using the selected reaction monitoring detection in the positive mode. The method has been validated over the clinically relevant concentrations ranging from 12.5 to 5000 ng/ml, 2.5 to 1000 ng/ml, 25 to 10,000 ng/ml, 10 to 4000 ng/ml, and 5 to 2000 ng/ml for RAL, MRV, DRV, ETV and RTV, respectively. The extraction recovery for all antiretroviral drugs is always above 91%. The method is precise, with mean inter-day CV% within 5.1-9.8%, and accurate (range of inter-day deviation from nominal values -3.3 to +5.1%). In addition our method enables the simultaneous assessment of raltegravir-glucuronide. This is the first analytical method allowing the simultaneous assay of antiretroviral agents targeted to four different steps of HIV replication. The proposed method is suitable for the Therapeutic Drug Monitoring Service of these new regimen combinations administered as salvage therapy to patients having experienced treatment failure, and for whom exposure, tolerance and adherence assessments are critical.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The persistence of high blood pressure under antihypertensive treatment (resistant hypertension) entails an increased cardiovascular risk. It occurs in three of ten treated hypertensive patients, and has several possible contributing factors, notably insufficient therapeutic adherence. There are a number of ways to evaluate whether patients take their medication as prescribed. These include interviewing the patient, pill counting, prescription follow-up, assay of drugs in blood or urine, and use of electronic pill dispensers. None is perfect. However, the essential is to discuss with the patient the importance of complying with the treatment as soon as it is prescribed for the first time, and not waiting for the appearance of resistant hypertension. The measurement of blood pressure outside the medical office and the monitoring of adherence may help to identify patients in whom hypertension is truly resistant and so to tailor the measures required to improve the control of blood pressure in the most appropriate manner.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Little is known on the relative importance of growth at different periods between birth and adolescence on blood pressure (BP). Objective: To assess the association between birth weight, change in body weight (growth) and BP across the entire span of childhood and adolescence. Methods: School-based surveys were conducted annually between 1998 and 2006 among all children in four school grades (kindergarten, 4th, 7th, and 10th year of compulsory school) in the Seychelles, Indian Ocean. Height and weight and BP were measured. Three cohorts of children examined twice were analyzed: 1606 children surveyed at age 5.5 and 9.1, 2557 at age 9.2 and 12.5, and 2065 at age 12.5 and 15.5, respectively. Weights at birth and at one year were extracted from medical files. Weights were expressed as Z-scores and growth was defined as a change in weight Z-scores (corresponding to weight centile crossing). The association between BP (at age 5.5, 9.2, 12.5, and 15.5) and weight at different times was assessed by linear regression. Using results of regression models of BP on all successive weights, life course plots were drawn by plotting regression coefficients against age at which weight was measured. The figure shows a life course plot of systolic BP in boys aged 15.5. Results: Without adjustment for current weight (at the time of BP measurement), birth weight was not associated with current BP, irrespective of age, excepted for girls at age 15.5 for whom a modest positive association was found. When adjusted for current weight, birth weight was negatively and modestly associated with current BP. BP was strongly associated with current weight, irrespective of age. Life course plots showed that BP was strongly associated with growth during the few preceding years but not with growth during earlier years, except for growth during the first year of life which tended to be associated with systolic BP. Conclusions: Our findings suggest that BP during childhood and adolescence is mainly determined by current body weight and recent growth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Body composition measured by dual-energy X-ray absorptiometry (DXA) is believed to be superior to crude measures such as BMI or waist circumference (WC) to assess health risks associated with adiposity in adults. We compared the ability of BMI, WC, waist-to-height ratio (WHtR), percentage body fat from skinfold thickness, and measures of total and central fat assessed by DXA to identify children with elevated blood pressure (BP). STUDY DESIGN: The QUALITY Study follows 630 Caucasian families (father, mother, and child originally aged 8-10 years). BP, height, weight, WC, and skinfold thickness were measured according to standardized protocols. Elevated BP was defined as systolic or diastolic BP at least 90th age, sex, and height-specific percentile. Total and central fat were determined with DXA. The area under the receiver operating characteristic (ROC) curve (AUC) statistic was computed from logistic models that adjusted for age, sex, height, Tanner stage, and physical activity. RESULTS: All adiposity indicators were highly correlated. WC and WHtR did not show superior ability over BMI to identify children with elevated SBP (P = 0.421 and 0.473). Measures of total and central fat from DXA did not show an improved ability over BMI or WC to identify children with elevated SBP (P = 0.325-0.662). CONCLUSION: Results support the use of BMI in clinical and public health settings, at least in this age group. As all indicators had a limited ability to identify children with elevated BP, results also support measurement of BP in all children of this age independent of a weight status.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background In an agreement assay, it is of interest to evaluate the degree of agreement between the different methods (devices, instruments or observers) used to measure the same characteristic. We propose in this study a technical simplification for inference about the total deviation index (TDI) estimate to assess agreement between two devices of normally-distributed measurements and describe its utility to evaluate inter- and intra-rater agreement if more than one reading per subject is available for each device. Methods We propose to estimate the TDI by constructing a probability interval of the difference in paired measurements between devices, and thereafter, we derive a tolerance interval (TI) procedure as a natural way to make inferences about probability limit estimates. We also describe how the proposed method can be used to compute bounds of the coverage probability. Results The approach is illustrated in a real case example where the agreement between two instruments, a handle mercury sphygmomanometer device and an OMRON 711 automatic device, is assessed in a sample of 384 subjects where measures of systolic blood pressure were taken twice by each device. A simulation study procedure is implemented to evaluate and compare the accuracy of the approach to two already established methods, showing that the TI approximation produces accurate empirical confidence levels which are reasonably close to the nominal confidence level. Conclusions The method proposed is straightforward since the TDI estimate is derived directly from a probability interval of a normally-distributed variable in its original scale, without further transformations. Thereafter, a natural way of making inferences about this estimate is to derive the appropriate TI. Constructions of TI based on normal populations are implemented in most standard statistical packages, thus making it simpler for any practitioner to implement our proposal to assess agreement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study shows how a new generation of terrestrial laser scanners can be used to investigate glacier surface ablation and other elements of glacial hydrodynamics at exceptionally high spatial and temporal resolution. The study area is an Alpine valley glacier, Haut Glacier d'Arolla, Switzerland. Here we use an ultra-long-range lidar RIEGL VZ-6000 scanner, having a laser specifically designed for measurement of snow- and ice-cover surfaces. We focus on two timescales: seasonal and daily. Our results show that a near-infrared scanning laser system can provide high-precision elevation change and ablation data from long ranges, and over relatively large sections of the glacier surface. We use it to quantify spatial variations in the patterns of surface melt at the seasonal scale, as controlled by both aspect and differential debris cover. At the daily scale, we quantify the effects of ogive-related differences in ice surface debris content on spatial patterns of ablation. Daily scale measurements point to possible hydraulic jacking of the glacier associated with short-term water pressure rises. This latter demonstration shows that this type of lidar may be used to address subglacial hydrologic questions, in addition to motion and ablation measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Several distributions of country-specific blood pressure (BP) percentiles by sex, age, and height for children and adolescents have been established worldwide. However, there are no globally unified BP references for defining elevated BP in children and adolescents, which limits international comparisons of the prevalence of pediatric elevated BP. We aimed to establish international BP references for children and adolescents by using 7 nationally representative data sets (China, India, Iran, Korea, Poland, Tunisia, and the United States). METHODS AND RESULTS: Data on BP for 52 636 nonoverweight children and adolescents aged 6 to 19 years were obtained from 7 large nationally representative cross-sectional surveys in China, India, Iran, Korea, Poland, Tunisia, and the United States. BP values were obtained with certified mercury sphygmomanometers in all 7 countries by using standard procedures for BP measurement. Smoothed BP percentiles (50th, 90th, 95th, and 99th) by age and height were estimated by using the Generalized Additive Model for Location Scale and Shape model. BP values were similar between males and females until the age of 13 years and were higher in males than females thereafter. In comparison with the BP levels of the 90th and 95th percentiles of the US Fourth Report at median height, systolic BP of the corresponding percentiles of these international references was lower, whereas diastolic BP was similar. CONCLUSIONS: These international BP references will be a useful tool for international comparison of the prevalence of elevated BP in children and adolescents and may help to identify hypertensive youths in diverse populations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Intraocular pressure (IOP) is the pressure inside the eye that helps to maintain the integrity and the suitable form of the ocular globe. Precise and accurate measures of IOP are needed for the diagnosis as well as follow-up of glaucoma. In daily clinical practice, Goldmann applanation tonometer (GAT) and Non-contact tonometer (NCT) are the most common devices for measuring IOP. A close agreement between these methods has been showed, particularly in normotensive patients and a poor agreement, especially when IOP levels are above the normal range. Ophthalmologists have noticed a poor agreement between NCT and GAT, observing that by using NCT and after comparing with GAT, there is an overestimation of IOP readings, and particularly it occurs when the eyes are tearful. Previous studies investigate the effect of tears in Non-contact tonometer readings by the instillation of artificial tears, concluding in one of the studies that the variation was less than 1mmHg and not clinically significant, in contrast with another study which the increases were sadistically significant. Tear menisci are a thin strip of tear fluid located between the bulbar conjunctiva and the eyelid margins. We think that the overestimation of IOP readings using NCT could be due to the presence of a higher volume of tear in the lower tear meniscus which might cause an optical interference in the optoelectronic applanation monitoring system of this deviceObjectives: To research the influence of a certain volume of fluid in the lower tear meniscus on IOP measurements using the NCT in healthy eyes. Moreover, to investigate the agreement between IOP readings obtained by NCT and GAT in the presence and absence of this volume of fluidMethods: The study design will be transversal for diagnostic tests of repeated measures. We will study patients with no ocular pathology and IOP<21mmHg. It will consist in the measurement of IOP using NCT before and after the instillation of COLIRCUSÍ FLUOTEST, used as a volume of fluid in the lower tear meniscus, to observe if there will be differences using the paired t-test. Moreover, we will take IOP measures by GAT in order to know the agreement between these methods after and before the application of these eyedrops, using the ICC (intraclass correlation coefficient) and the Bland-Altmann method

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the present work is the experimental determination of pressure drop coefficients (loss coefficients) for elliptic and circular sections in one, two and three-row arrangements of plate fin and tube heat exchangers. The experiments permitted to correlate the dimensionless loss coefficient with the flow Reynolds number in the rectangular channel formed by the plate fins. The experimental technique consisted of the measurement of the longitudinal pressure distribution along the flow channel, for several values of air mass flow rate. The total number of data runs, each one characterized by the flow Reynolds number, was 216. The present geometry is used in compact heat exchangers for air conditioning systems, heaters, radiators, and others. Also, it is verified the influence of the utilization of elliptic tubes, instead of circular ones, in the pressure drop. The measurements were performed for Reynolds numbers ranging from 200 to 1900.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The most important component of the upper esophageal sphincter (UES) is the cricopharyngeal muscle. During the measurement of sphincter pressure the catheter passed through the sphincter affects the pressure value. In Chagas' disease and primary achalasia there is an esophageal myenteric plexus denervation which may affect UES pressure. We measured the UES pressure of 115 patients with Chagas' disease, 28 patients with primary achalasia and 40 healthy volunteers. We used a round manometric catheter with continuous perfusion and the rapid pull-through method, performed in triplicate during apnea. Pressures were measured in four directions, and the direction with the highest pressure (anterior/posterior) and the average of the four directions were measured. The highest UES pressure in Chagas' disease patients without abnormalities upon radiologic esophageal examination (N = 63) was higher than in normal volunteers (142.8 ± 47.4 mmHg vs 113.0 ± 46.0 mmHg, mean ± SD, P<0.05). There was no difference in UES pressure between patients with primary achalasia and patients with Chagas' disease and similar esophageal involvement and normal volunteers (P>0.05). There was no difference between patients with or without esophageal dilation. In the group of subjects less than 50 years of age the UES pressure of primary achalasia (N = 21) was lower than that of Chagas' disease patients with normal radiologic esophageal examination (N = 41), measured at the site with the highest pressure (109.3 ± 31.5 mmHg vs 149.6 ± 45.3 mmHg, P<0.01) and as the average of the four directions (64.2 ± 17.1 mmHg vs 83.5 ± 28.6 mmHg, P<0.05). We conclude that there is no difference in UES pressure between patients with Chagas' disease, primary achalasia and normal volunteers, except for patients with minor involvement by Chagas' disease, for whom the UES pressure at the site with the highest pressure was higher than the pressure of normal volunteers and patients with primary achalasia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The kallikrein-kinin system is complex, with several bioactive peptides that are formed in many different compartments. Kinin peptides are implicated in many physiological and pathological processes including the regulation of blood pressure and sodium homeostasis, inflammatory processes, and the cardioprotective effects of preconditioning. We established a methodology for the measurement of individual kinin peptides in order to study the function of the kallikrein-kinin system. The levels of kinin peptides in tissues were higher than in blood, confirming the primary tissue localization of the kallikrein-kinin system. Moreover, the separate measurement of bradykinin and kallidin peptides in man demonstrated the differential regulation of the plasma and tissue kallikrein-kinin systems, respectively. Kinin peptide levels were increased in the heart of rats with myocardial infarction, in tissues of diabetic and spontaneously hypertensive rats, and in urine of patients with interstitial cystitis, suggesting a role for kinin peptides in the pathogenesis of these conditions. By contrast, blood levels of kallidin, but not bradykinin, peptides were suppressed in patients with severe cardiac failure, suggesting that the activity of the tissue kallikrein-kinin system may be suppressed in this condition. Both angiotensin converting enzyme (ACE) and neutral endopeptidase (NEP) inhibitors increased bradykinin peptide levels. ACE and NEP inhibitors had different effects on kinin peptide levels in blood, urine, and tissues, which may be accounted for by the differential contributions of ACE and NEP to kinin peptide metabolism in the multiple compartments in which kinin peptide generation occurs. Measurement of the levels of individual kinin peptides has given important information about the operation of the kallikrein-kinin system and its role in physiology and disease states.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The first minutes of the time course of cardiopulmonary reflex control evoked by lower body negative pressure (LBNP) in patients with hypertensive cardiomyopathy have not been investigated in detail. We studied 15 hypertensive patients with left ventricular dysfunction (LVD) and 15 matched normal controls to observe the time course response of the forearm vascular resistance (FVR) during 3 min of LBNP at -10, -15, and -40 mmHg in unloading the cardiopulmonary receptors. Analysis of the average of 3-min intervals of FVR showed a blunted response of the LVD patients at -10 mmHg (P = 0.03), but a similar response in both groups at -15 and -40 mmHg. However, using a minute-to-minute analysis of the FVR at -15 and -40 mmHg, we observed a similar response in both groups at the 1st min, but a marked decrease of FVR in the LVD group at the 3rd min of LBNP at -15 mmHg (P = 0.017), and -40 mmHg (P = 0.004). Plasma norepinephrine levels were analyzed as another neurohumoral measurement of cardiopulmonary receptor response to LBNP, and showed a blunted response in the LVD group at -10 (P = 0.013), -15 (P = 0.032) and -40 mmHg (P = 0.004). We concluded that the cardiopulmonary reflex response in patients with hypertensive cardiomyopathy is blunted at lower levels of LBNP. However, at higher levels, the cardiopulmonary reflex has a normal initial response that decreases progressively with time. As a consequence of the time-dependent response, the cardiopulmonary reflex response should be measured over small intervals of time in clinical studies.