980 resultados para Power factor corrector
Resumo:
The purpose of the present study was to verify the memory exponents of power function for area in observers of different age and educational levels (elementary school, high school or undergraduate school), using the psychophysics method of magnitude estimation. For the age level I (17 to 30 years old) there was no difference among educational levels, although for the age level II (45 to 60 years old) the differences were significant. Tn the age level II, there was a tendency for greater variability of the responses for lower educational levels. The data obtained for the age level I did not show the same results, although a significant difference among the three educational levels was observed. We call conclude that the mnemonic processes present different results when we observe the answers from observers with different ages. This result leads us to suppose that the motivational factor related to the stimulus used can interact with the mnemonic processes.
Resumo:
Continuation methods have been shown as efficient tools for solving ill-conditioned cases, with close to singular Jacobian matrices, such as the maximum loading point of power systems. Some parameterization techniques have been proposed to avoid matrix singularity and successfully solve those cases. This paper presents a new geometric parameterization scheme that allows the complete tracing of the P-V curves without ill-conditioning problems. The proposed technique associates robustness to simplicity and, it is of easy understanding. The Jacobian matrix singularity is avoided by the addition of a line equation, which passes through a point in the plane determined by the total real power losses and loading factor. These two parameters have clear physical meaning. The application of this new technique to the IEEE systems (14, 30, 57, 118 and 300 buses) shows that the best characteristics of the conventional Newton's method are not only preserved but also improved. (C) 2006 Elsevier B.V. All rights reserved.
Resumo:
A low-voltage low-power 2nd-order CMOS pseudo-differential bump-equalizer is presented. Its topology comprises a bandpass section with adjustable center frequency and quality factor, together with a programmable current amplifier. The basic building blocks are triode-operating transconductors, tunable by means of either a DC voltage or a digitally controlled current divider. The bump-equalizer as part of a battery-operated hearing aid device is designed for a 1.4V-supply and a 0.35μm CMOS fabrication process. The circuit performance is supported by a set of simulation results, which indicates a center frequency from 600Hz to 2.4kHz, 1≤Q≤5, and an adjustable gain within ±6dB at center frequency. The filter dynamic range lies around 40dB. Quiescent consumption is kept below 12μW for any configuration of the filter.
Resumo:
This paper presents some initial concepts for including reactive power in linear methods for computing Available Transfer Capability (ATC). It is proposed an approximation for the reactive power flows computation that uses the exact circle equations for the transmission line complex flow, and then it is determined the ATC using active power distribution factors. The transfer capability can be increased using the sensitivities of flow that show the best group of buses which can have their reactive power injection modified in order to remove the overload in the transmission lines. The results of the ATC computation and of the use of the sensitivities of flow are presented using the Cigré 32-bus system. © 2004 IEEE.
Resumo:
This paper presents the comparison of three topologies of multilevel inverters applied to drive an induction motor of 500 kVA/4.16 kV. The multilevel inverters analyzed are: a neutral point clamped inverter, a symmetrical cascaded multilevel inverter and a hybrid asymmetrical cascaded multilevel inverter. The performance indexes used in the comparison are total harmonic distortion, first order distortion factor, semiconductors power losses distribution and heat-sink volume. The comparison is developed with the purpose of finding the efficiency and the heat-sink volume where the three systems present the same output filter. ©2008 IEEE.
Resumo:
This paper presents evaluations among the most usual MPPT techniques, doing meaningful comparisons with respect to the amount of energy extracted from the photovoltaic panel (PV) (Tracking Factor - TF) in relation to the available power, PV voltage ripple, dynamic response and use of sensors. Using MatLab/Simulink® and DSpace platforms, a digitally controlled boost DC-DC converter was implemented and connected to an Agilent Solar Array E4350B simulator in order to verify the analytical procedures. The main experimental results are presented and a contribution in the implementation of the IC algorithm is performed and called IC based on PI. Moreover, the dynamic response and the tracking factor are also evaluated using a Friendly User Interface, which is capable of online program power curves and compute the TF. Finally, a typical daily insulation is used in order to verify the experimental results for the main PV MPPT methods. © 2011 IEEE.
Resumo:
This paper presents a power system capacity expansion planning modelconsidering carbon emissions constraints. In addition to the traditionaltechnical and economical issues usually considered in the planning process, two environmental policies that consist on the taxation and the annual limitsof carbon dioxide (CO 2) emissions are considered. Furthermore, the gradualretirement of old inefficient generation plants has been included. The approachguarantees a cleaner electricity production in the expanded power system ata relatively low cost. The proposed model considers the transmission systemand is applied to a 4-region and 11-region power systems over a 20-yearplanning horizon. Results show practical investment decisions in terms of sustainability and costs.
Resumo:
This paper presents efficient geometric parameterization techniques using the tangent and the trivial predictors for the continuation power flow, developed from observation of the trajectories of the load flow solution. The parameterization technique eliminates the Jacobian matrix singularity of load flow, and therefore all the consequent problems of ill-conditioning, by the addition of the line equations which pass through the points in the plane determined by the variables loading factor and the real power generated by the slack bus, two parameters with clear physical meaning. This paper also provides an automatic step size control around the maximum loading point. Thus, the resulting method enables not only the calculation of the maximum loading point, but also the complete tracing of P-V curves of electric power systems. The technique combines robustness with ease of understanding. The results to the IEEE 300-bus system and of large real systems show the effectiveness of the proposed method. © 2012 IEEE.
Resumo:
Background: Macrophage migration inhibitory factor (MIF) is a pleiotropic cytokine with pro-inflammatory functions and involved in tumorigenesis. The aim of this study was to evaluate the expression and localization of the macrophage MIF in oral squamous carcinoma (OSC). In addition, the relationship between MIF expression and clinicopathological parameters such as survival data, tobacco use, alcohol habits, TNM stage, tumor graduation, and peritumoral inflammatory infiltrate were evaluated. Methods: Using immunohistochemistry, expression and localization of MIF was detected in 44 specimens of OSC. The absolute number and relative proportions of MIF-positive cells detected were also determined separately for tumor parenchyma vs. stroma. All counts were determined from 10 consecutive high-power fields using an integration graticule. Moreover, some parameters were analyzed separately for lip and intra-oral cancers. Results: Migration inhibitory factor-positive cells were observed in both the tumor parenchyma and in inflammatory cells of all specimens. In contrast, MIF expression was not detected in tumoral nests associated with poorly differentiated tumors. In specimens of lip cancer, a greater number of MIF-positive stromal immune cells were detected than in intra-oral cancer specimens (Mann-Whitney test, P = 0.049). Conclusions: Oral squamous carcinoma cells consistently express MIF independent of their location. Lip tumors presented more MIF-positive peritumoral inflammatory cells, similar to control, suggesting that immunological differences in leukocyte activation exist between in lip and intra-oral cancers. © 2012 John Wiley & Sons A/S.
Resumo:
This article applies the stochastic-frontier model to examine total factor productivity (tfp) and its components in Latin America between 1960 and 2010. The likelihood-ratio test shows that, for a selection of Latin American countries over the 50 years analysed, the macroeconomic variables of technical inefficiency included in the model generally have a significant effect; and they allow for a better understanding of technical inefficiency throughout the region. The key variables explaining technical inefficiency in the selected countries are public expenditure and the inflation rate; and there is also an inverse relation between technical inefficiency and the extent to which local prices diverge from purchasing power parity.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
In this paper, the optimal reactive power planning problem under risk is presented. The classical mixed-integer nonlinear model for reactive power planning is expanded into two stage stochastic model considering risk. This new model considers uncertainty on the demand load. The risk is quantified by a factor introduced into the objective function and is identified as the variance of the random variables. Finally numerical results illustrate the performance of the proposed model, that is applied to IEEE 30-bus test system to determine optimal amount and location for reactive power expansion.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This work presents the application of Linear Matrix Inequalities to the robust and optimal adjustment of Power System Stabilizers with pre-defined structure. Results of some tests show that gain and zeros adjustments are sufficient to guarantee robust stability and performance with respect to various operating points. Making use of the flexible structure of LMI's, we propose an algorithm that minimizes the norm of the controllers gain matrix while it guarantees the damping factor specified for the closed loop system, always using a controller with flexible structure. The technique used here is the pole placement, whose objective is to place the poles of the closed loop system in a specific region of the complex plane. Results of tests with a nine-machine system are presented and discussed, in order to validate the algorithm proposed. (C) 2012 Elsevier Ltd. All rights reserved.