931 resultados para Point of zero net proton charge
Resumo:
This article reports on an experimental method to fully reconstruct laser-accelerated proton beam parameters called radiochromic film imaging spectroscopy (RIS). RIS allows for the characterization of proton beams concerning real and virtual source size, envelope- and microdivergence, normalized transverse emittance, phase space, and proton spectrum. This technique requires particular targets and a high resolution proton detector. Therefore thin gold foils with a microgrooved rear side were manufactured and characterized. Calibrated GafChromic radiochromic film (RCF) types MD-55, HS, and HD-810 in stack configuration were used as spatial and energy resolved film detectors. The principle of the RCF imaging spectroscopy was demonstrated at four different laser systems. This can be a method to characterize a laser system with respect to its proton-acceleration capability. In addition, an algorithm to calculate the spatial and energy resolved proton distribution has been developed and tested to get a better idea of laser-accelerated proton beams and their energy deposition with respect to further applications.
Resumo:
A new approach to spectroscopy of laser induced proton beams using radiochromic film (RCF) is presented. This approach allows primary standards of absorbed dose-to-water as used in radiotherapy to be transferred to the calibration of GafChromic HD-810 and EBT in a 29 MeV proton beam from the Birmingham cyclotron. These films were then irradiated in a common stack configuration using the TARANIS Nd:Glass multi-terawatt laser at Queens University Belfast, which can accelerate protons to 10-12 MeV, and a depth-dose curve was measured from a collimated beam. Previous work characterizing the relative effectiveness (RE) of GafChromic film as a function of energy was implemented into Monte Carlo depth-dose curves using FLUKA. A Bragg peak (BP) "library" for proton energies 0-15 MeV was generated, both with and without the RE function. These depth-response curves were iteratively summed in a FORTRAN routine to solve for the measured RCF depth-dose using a simple direct search algorithm. By comparing resultant spectra with both BP libraries, it was found that the effect of including the RE function accounted for an increase in the total number of protons by about 50%. To account for the energy loss due to a 20 mu m aluminum filter in front of the film stack, FLUKA was used to create a matrix containing the energy loss transformations for each individual energy bin. Multiplication by the pseudo-inverse of this matrix resulted in "up-shifting" protons to higher energies. Applying this correction to two laser shots gave further increases in the total number of protons, N of 31% and 56%. Failure to consider the relative response of RCF to lower proton energies and neglecting energy losses in a stack filter foil can potentially lead to significant underestimates of the total number of protons in RCF spectroscopy of the low energy protons produced by laser ablation of thin targets.
Resumo:
In this study, we describe a simple and efficient method for on-chip storage of reagents for point-of-care (POC) diagnostics. The method is based on gelification of all reagents required for on-chip PCR-based diagnostics as a ready-to-use product. The result reported here is a key step towards the development of a ready and easy to use fully integrated Lab-on-a-chip (LOC) system for fast, cost-effective and efficient POC diagnostics analysis.
Resumo:
The tendon of flexor pollicis longus angulates at the trapezio-metacarpal joint level. The degree of angulation varies with extent of radial/ulnar deviation (Rack and Ross [1984] J. Physiol. 351:99–110). We report a fibrous pulley at this level that helps stabilize the tendon and facilitates its action. The morphology of the pulley is described. We believe that it has an important role to play in the unique function of the tendon facilitating the movement of the thumb perpendicular to the plane of the thumbnail. Clin. Anat. 21:427–432, 2008. © 2008 Wiley-Liss, Inc
Resumo:
Suitable instrumentation for laser-accelerated proton (ion) beams is critical for development of integrated, laser-driven ion accelerator systems. Instrumentation aimed at beam diagnostics and control must be applied to the driving laser pulse, the laser-plasma that forms at the target and the emergent proton (ion) bunch in a correlated way to develop these novel accelerators. This report is a brief overview of established diagnostic techniques and new developments based on material presented at the first workshop on 'Instrumentation for Diagnostics and Control of Laser-accelerated Proton (Ion) Beams' in Abingdon, UK. It includes radiochromic film (RCF), image plates (IP), micro-channel plates (MCP), Thomson spectrometers, prompt inline scintillators, time and space-resolved interferometry (TASRI) and nuclear activation schemes. Repetition-rated instrumentation requirements for target metrology are also addressed. (C) 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Resumo:
Permeable reactive barriers (PRBs) of zero-valent iron (Fe0) are increasingly being used to remediate contaminated ground water. Corrosion of Fe0 filings and tbe formation of precipitates can occur when the PRB material comes in contact with ground water and may reduce the lifespan and effectiveness of the barrier. At present, there are no routine procedures for preparing and analyzing the mineral precipitates from Fe0 PRB material. These procedures are needed because mineralogical composition of corrosion products used to interpret the barrier processes can change with iron oxidation and sample preparation. The objectives of this study were (i) to investigate a method of preparing Fe0 reactive barrier material for mineralogical analysis by X-ray diffraction (XRD), and (ii) to identify Fe mineral phases and rates of transformations induced by different mineralogical preparation techniques. Materials from an in situ Fe0 PRB were collected by undisturbed coring and processed for XRD analysis after different times since sampling for three size fractions and by various drying treatments. We found that whole-sample preparation for analysis was necessary because mineral precipitates occurred within the PRB material in different size fractions of the samples. Green rusts quickly disappeared from acetone-dried samples and were not present in air-dried and oven-dried samples Maghemite/magnetite content increased over time and in oven-dried samples, especially after heating to 105°C. We conclude that care must be taken during sample preparation of Fe0 PRB material, especially for detection of green rusts, to ensure accurate identification of minerals present within the barrier system.
Resumo:
Shoeprint evidence collected from crime scenes can play an important role in forensic investigations. Usually, the analysis of shoeprints is carried out manually and is based on human expertise and knowledge. As well as being error prone, such a manual process can also be time consuming; thus affecting the usability and suitability of shoeprint evidence in a court of law. Thus, an automatic system for classification and retrieval of shoeprints has the potential to be a valuable tool. This paper presents a solution for the automatic retrieval of shoeprints which is considerably more robust than existing solutions in the presence of geometric distortions such as scale, rotation and scale distortions. It addresses the issue of classifying partial shoeprints in the presence of rotation, scale and noise distortions and relies on the use of two local point-of-interest detectors whose matching scores are combined. In this work, multiscale Harris and Hessian detectors are used to select corners and blob-like structures in a scale-space representation for scale invariance, while Scale Invariant Feature Transform (SIFT) descriptor is employed to achieve rotation invariance. The proposed technique is based on combining the matching scores of the two detectors at the score level. Our evaluation has shown that it outperforms both detectors in most of our extended experiments when retrieving partial shoeprints with geometric distortions, and is clearly better than similar work published in the literature. We also demonstrate improved performance in the face of wear and tear. As matter of fact, whilst the proposed work outperforms similar algorithms in the literature, it is shown that achieving good retrieval performance is not constrained by acquiring a full print from a scene of crime as a partial print can still be used to attain comparable retrieval results to those of using the full print. This gives crime investigators more flexibility is choosing the parts of a print to search for in a database of footwear.
Resumo:
This paper describes a study that used video materials and visits to an airport to prepare children on the autism spectrum for travel by plane. Twenty parents and carers took part in the study with children aged from 3 to 16 years. The authors explain that the methods they used were based on Applied Behaviour Analysis (ABA) research; a video modeling technique called Point-Of-View Video-priming and during visits to an airport they used procedures known as Natural Environment Teaching. The findings suggest that using video and preparing children by taking them through what is likely to happen in the real environment when they travel by plane is effective and the authors suggest these strategies could be used to support children with autism with other experiences they need or would like to engage in such as visits to the dentist or hairdressers and access to leisure centres and other public spaces.
Resumo:
Tracking primary radiation-induced processes in matter requires ultrafast sources and high precision timing. While compact laser-driven ion accelerators are seeding the development of novel high instantaneous flux applications, combining the ultrashort ion and laser pulse durations with their inherent synchronicity to trace the real-time evolution of initial damage events has yet to be realized. Here we report on the absolute measurement of proton bursts as short as 3.5±0.7 ps from laser solid target interactions for this purpose. Our results verify that laser-driven ion acceleration can deliver interaction times over a factor of hundred shorter than those of state-of-the-art accelerators optimized for high instantaneous flux. Furthermore, these observations draw ion interaction physics into the field of ultrafast science, opening the opportunity for quantitative comparison with both numerical modelling and the adjacent fields of ultrafast electron and photon interactions in matter.
Resumo:
This paper assesses whether two sustainability policies currently in effect in London, a congestion charge zone and a low emission zone, have affected freight operations and reduced vehicle kilometers travelled. It investigates responses by freight operators, including re-timing, re-routing, or reducing the number of trips, or replacing vehicles. Freight traffic trends from 1994 to 2012 were identified using road traffic estimates, cordon counts, and vehicle speed data and supplemented by interviews with freight industry experts and operators. Findings indicate that freight traffic increased throughout London during this timeframe, but declined in the central boroughs partly within the congestion charge zone. The congestion charge may have time-shifted some light goods trips, but most freight trips face a variety of constraints on operators’ delivery window. No evidence was found of re-routing of freight traffic or avoidance traffic around the charged zone. The low emission zone spurred higher levels of operational change than the congestion charge zone, and it was effective at spurring freight vehicle replacement. The paper also discusses freight operators’ perceptions of these policies and how they could be improved.
Resumo:
The 2013–2015 Ebolavirus disease humanitarian crisis has spurred the development of laboratory-free, point-of-care nucleic acid testing solutions. EbolaCheck is an international consortium of public health, academic and biotechnology industry stakeholders aiming to deliver clinical molecular diagnostic standard-of-care testing suitable for the West African milieu within 12 months. In this article, the current status of the EbolaCheck platform is discussed in the context of the current regulatory framework. Presented here are future goals to achieve differential diagnosis of hemorrhagic fever disease from <5-μl of whole blood samples or mucosal biofluids, in a single tube process, under 40 min and with minimal operator training requirements.