910 resultados para Permanent magnet synchronous generator


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the field oriented control of a salient pole wound field synchronous machine in stator flux coordinates. The procedure for derivation of flux linkage equations along any general rotating axes including stator flux axes is given. The stator flux equations are used to identify the cross-coupling occurring between the axes due to saliency in the machine. The coupling terms are canceled as feedforward terms in the generation of references for current controllers to achieve good decoupling during transients. The design of current controller for stator-flux-oriented control is presented. This paper proposes the method of extending rotor flux closed loop observer for sensorless control of wound field synchronous machine. This paper also proposes a new sensorless control by using stator flux closed loop observer and estimation of torque angle using stator current components in stator flux coordinates. Detailed experimental results from a sensorless 15.8 hp salient pole wound field synchronous machine drive are presented to demonstrate the performance of the proposed control strategy from a low speed of 0.8 Hz to 50 Hz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional thyristor-based load commutated inverter (LCI)-fed wound field synchronous machine operates only above a minimum speed that is necessary to develop enough back emf to ensure commutation. The drive is started and brought up to a speed of around 10-15% by a complex `dc link current pulsing' technique. During this process, the drive have problems such as pulsating torque, insufficient average starting torque, longer starting time, etc. In this regard a simple starting and low-speed operation scheme, by employing an auxiliary low-power voltage source inverter (VSI) between the LCI and the machine terminals, is presented in this study. The drive is started and brought up to a low speed of around 15% using the VSI alone with field oriented control. The complete control is then smoothly and dynamically transferred to the conventional LCI control. After the control transfer, the VSI is turned off and physically disconnected from the main circuit. The advantages of this scheme are smooth starting, complete control of torque and flux at starting and low speeds, less starting time, stable operation, etc. The voltage rating of the required VSI is very low of the order of 10-15%, whereas the current rating is dependent on the starting torque requirement of the load. The experimental results from a 15.8 hp LCI-fed wound field synchronous machine are given to demonstrate the scheme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Load commutated inverter (LCI)-fed wound field synchronous motor drives are used for medium-voltage high-power drive applications. This drive suffers from drawbacks such as complex starting procedure, sixth harmonic torque pulsations, quasi square wave motor current, notches in the terminal voltages, etc. In this paper, a hybrid converter circuit, consisting of an LCI and a voltage source inverter (VSI), is proposed, which can be a universal high-power converter solution for wound field synchronous motor drives. The proposed circuit, with the addition of a current-controlled VSI, overcomes nearly all of the shortcomings present in the conventional LCI-based system besides providing many additional advantages. In the proposed drive, the motor voltage and current are always sinusoidal even with the LCI switching at the fundamental frequency. The performance of the drive is demonstrated with detailed experimental waveforms from a 15.8-hp salient pole wound field synchronous machine. Finally, a brief description of the control scheme used for the proposed circuit is given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The role of the soft phase (Ni0.8Zn0.2Fe2O4) on the magnetization reversal and coercivity mechanism of the Ni0.8Zn0.2Fe2O4/BaFe12O19 nanocomposite has been investigated. The presence of the interacting field and the disorder in the nanocomposite has been confirmed by the variation of Jr/Jr(∞) vs Jd/Jr(∞) and the irreversible magnetization. To understand the relative strength of the pinning and the nucleation, the magnetic viscosity measurement has been done and the thermal activation volume has been estimated. From the Barbier plot and the activation volume measurement, the dominant mechanism governing the magnetization reversal process has been proposed.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neutron time-of-flight spectroscopy has been employed to study the crystal-field interaction in the pyrochlore titanate Ho2Ti2O7. The crystal-field parameters and corresponding energy-level scheme have been determined from a profile fit to the observed neutron spectra. The ground state is a well separated Eg doublet with a strong Ising-like anisotropy, which can give rise to frustration in the pyrochlore lattice. Using the crystal-field parameters determined for the Ho compound as an estimate of the crystal-field potential in other pyrochlore magnets, we also find the Ising type behavior for Dy. In contrast, the almost planar anisotropy found for Er and Yb prevents frustration, because of the continuous range of possible spin orientations in this case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the dynamic stability analysis of a single machine infinite bus system through torque angle loop analysis and forms an extension of the work on Block diagrams and torque angle loop analysis of synchronous machines reported by I. Nagy [3]. It aims to incorporate in the machine model, the damper windings (one on each axis) and to compare the dynamic behaviour of the system with and without damper windings. The effect of using different stabilizing signals (viz. active power and speed deviations) on the dynamic performance is analysed and the significant effect of damper windings on the dynamic behaviour of the system is highlighted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here we study thermodynamic properties of an important class of single-chain magnets (SCMs), where alternate units are isotropic and anisotropic with anisotropy axes being non-collinear. This class of SCMs shows slow relaxation at low temperatures which results from the interplay of two different relaxation mechanisms, namely dynamical and thermal. Here anisotropy is assumed to be large and negative, as a result, anisotropic units behave like canted spins at low temperatures; but even then simple Ising-type model does not capture the essential physics of the system due to quantum mechanical nature of the isotropic units. We here show how statistical behavior of this class of SCMs can be studied using a transfer matrix (TM) method. We also, for the first time, discuss in detail how weak inter-chain interactions can be treated by a TM method. The finite size effect is also discussed which becomes important for low temperature dynamics. At the end of this paper, we apply this technique to study a real helical chain magnet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Controlled waveform magnets (CWMs) are a class of pulsed magnets whose pulse shape with time can be programmed by the user. With a CWM, the user gains control not only over the magnitude of the field but also over its rate of change. In this work we present a table-top CWM, driven by a capacitor bank, capable of producing virtually any user-shaped magnetic field waveform up to 10 tesla. Insulated gate bipolar transistor chips have been paralleled to form the high current switch and paralleled chips of SiC Schottky diodes form the crowbar diode module. Sample controlled waveforms including flat-tops up to 10 tesla and some triangular magnetic field pulses have been successfully generated for 10-20 ms with a ripple < 1%. (C) 2012 American Institute of Physics. http://dx.doi.org/10.1063/1.3699316]