995 resultados para Oral implants


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: In alveolar distraction, in cases of severe atrophy in particular, it is often difficult to perform osteotomies in order to make a transport segment in optimal size and shape. Moreover care must be taken, not to damage the closely locating anato- mical structures such as the maxillary sinus, the inferior alveolar nerve, and the roots of the neighboring teeth. For setting ideal osteotomy lines exactly, we have developed a CT-based preoperative planning tool. Methods: 3-dimensional visual reconstruction of the jaw is created from the preoperative CT scans (1.0-mm slice thick- ness). Using the image-processing software Mimics (Materialise, Yokohama, Japan), various procedures of virtual cutting are simulated first to determine optimal osteotomy lines and to design an ideal transport segment. After the computer planning, data from the virtual solid model are transferred to a rapid prototype model, and a guiding splint is made to transfer the planned surgical simulation to the actual surgery. Results: The method was used in a case of severe atrophy of the anterior maxilla. The patient had a large maxillary sinus requir- ing a precise osteotomy in this critical area. Using the splint allowing a 3-dimensional guidance, alveolar osteotomies were easily done to achieve a transport segment in sufficient dimen- sion as planned, and any perforation of the maxillary sinus could be avoided. Finally the alveolar distraction of 10mm has suc- cessfully been performed. Conclusion: The preoperative planning method and the guiding splint described here are useful in problematic cases requiring an extremely precise osteotomy due to lack of bony space.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The application of implant-borne rehabilitations in residual alveolar ridges may be restricted by various anatomic conditions, as available bone height and characteristics. Here we report the clinical outcome of implants placed in severely resorbed posterior ridges, in addition to various implant-supported treatment modalities. Extra Oral implants (Straumann, Basel, Switzerland) with the intraosseous length of 2.5–5mm were installed in the posterior alveolar ridges. Following the healing period of 4–6 months, implants were exposed and included in the distal extensions of fixed and removable prosthesis. At recall appointments were collected surgical, clinical and radiological variables, including the evidence of adverse effects. An 8-years life table analysis was calculated. The treatment protocol was applied in thirty-five patients, presenting 31 removable and 4 fixed complete implant-supported dentures. A total of 61 Extra Oral implants were placed posterior to the distal implants, at the mean distance of 29.8mm (range 15.6–62.7mm). Three implants failed during the osteointegration phase, yielding an 8-year cumulative success rate of 92.24%. Following the osteointegration period, no major bone loss or other adverse events were found. The clinical results indicated that the Extra Oral implants may be successfully used in addition to the other, longer implants. Thus, a relatively long extension in the posterior region may be employed. With careful preoperative planning, this technique offers a simple and beneficial complementary treatment option for removable and fixed complete dentures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the pattern of tissue remodeling after maxillary sinus floor elevation using the transalveolar osteotome technique with or without utilizing grafting materials. METHODS: During the period of 2000-2005, 252 Straumann dental implants were inserted using the transalveolar sinus floor elevation technique in a group of 181 patients. For 88 or 35% of those implants, deproteinized bovine bone mineral with a particle size of 0.25-1 mm was used as the grafting material, but for the remaining 164 implants, no grafting material was utilized. Periapical radiographs were obtained with a paralleling technique and digitized. Two investigators, who were blinded to whether grafting material was used or not, subsequently evaluated the pattern of tissue remodeling. RESULTS: The mean residual bone height was 7.5 mm (SD 2.2 mm), ranging from 2 to 12.7 mm. The mean residual bone height for implants placed with grafting material (6.4 mm) was significantly less compared with the implants installed without grafting material (8.1 mm). The implants penetrated on average 3.1 mm (SD 1.7 mm) into the sinus cavity. The measured mean radiographic bone gain using the transalveolar technique without grafting material was significantly less, 1.7 mm (SD 2 mm) compared with a mean bone gain of 4.1 mm (SD 2.4 mm), when grafting material was used. Furthermore, the probability of gaining 2 mm or more of new bone was 39.1% when no grafting material was used. The probability increased to 77.9% when the implants were installed with grafting material. CONCLUSION: When the transalveolar sinus floor elevation was performed without utilizing grafting material, only a moderate gain of new bone could be detected mesial and distal to the implants. On the other hand, when grafting material was used, a substantial gain of new bone was usually seen on the radiographs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: To analyze the survival and success rates of implants installed utilizing the (transalveolar) osteotome technique, to compare peri-implant soft tissue parameters and marginal bone levels of osteotome-installed implants with implants placed using standard surgical procedures, and to evaluate patient-centered outcomes. MATERIAL AND METHODS: During 2000 to 2005, 252 Straumann dental implants were inserted in 181 patients. The surgical technique was a modification of the original osteotome technique presented by Summers. In addition to the clinical examination, the patients were asked to give their perception of the surgical procedure, utilizing a visual analogue scale. RESULTS: The cumulative survival rate of the osteotome-installed implants after a mean follow-up time of 3.2 years, was 97.4% (95% confidence intervals: 94.4-98.8%). From the 252 implants inserted, three were lost before loading and another three were lost in the first and second year. According to residual bone height the survival was 91.3% for implant sites with < or =4 mm residual bone height, and 90% for sites with 4 mm and 5 mm, when compared with that of 100% in sites with bone height of above 5 mm. According to implant length the survival rates were 100% for 12 mm, 98.7% for 10 mm, 98.7% for 8 mm and only 47.6% for 6 mm implants. Soft tissue parameters (pocket probing depth, probing attachment level, bleeding on probing and marginal bone levels) did not yield any differences between the osteotome-installed and the conventionally placed implants. More than 90% of the patients were satisfied with the implant therapy and would undergo similar therapy again if necessary. The cost associated with implant therapy was considered to be justified. CONCLUSION: In conclusion, the osteotome technique was a reliable method for implant insertion in the posterior maxilla, especially at sites with 5 mm or more of preoperative residual bone height and a relatively flat sinus floor.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIM: The purpose of this study was to systematically review the literature on the survival rates of palatal implants, Onplants((R)), miniplates and mini screws. MATERIAL AND METHODS: An electronic MEDLINE search supplemented by manual searching was conducted to identify randomized clinical trials, prospective and retrospective cohort studies on palatal implants, Onplants((R)), miniplates and miniscrews with a mean follow-up time of at least 12 weeks and of at least 10 units per modality having been examined clinically at a follow-up visit. Assessment of studies and data abstraction was performed independently by two reviewers. Reported failures of used devices were analyzed using random-effects Poisson regression models to obtain summary estimates and 95% confidence intervals (CI) of failure and survival proportions. RESULTS: The search up to January 2009 provided 390 titles and 71 abstracts with full-text analysis of 34 articles, yielding 27 studies that met the inclusion criteria. In meta-analysis, the failure rate for Onplants((R)) was 17.2% (95% CI: 5.9-35.8%), 10.5% for palatal implants (95% CI: 6.1-18.1%), 16.4% for miniscrews (95% CI: 13.4-20.1%) and 7.3% for miniplates (95% CI: 5.4-9.9%). Miniplates and palatal implants, representing torque-resisting temporary anchorage devices (TADs), when grouped together, showed a 1.92-fold (95% CI: 1.06-2.78) lower clinical failure rate than miniscrews. CONCLUSION: Based on the available evidence in the literature, palatal implants and miniplates showed comparable survival rates of >or=90% over a period of at least 12 weeks, and yielded superior survival than miniscrews. Palatal implants and miniplates for temporary anchorage provide reliable absolute orthodontic anchorage. If the intended orthodontic treatment would require multiple miniscrew placement to provide adequate anchorage, the reliability of such systems is questionable. For patients who are undergoing extensive orthodontic treatment, force vectors may need to be varied or the roots of the teeth to be moved may need to slide past the anchors. In this context, palatal implants or miniplates should be the TADs of choice.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIM: The aim of the present review was to systematically assess the dental literature in terms of soft tissue grafting techniques. The focused question was: is one method superior over others for augmentation and stability of the augmented soft tissue in terms of increasing the width of keratinized tissue (part 1) and gain in soft tissue volume (part 2). METHODS: A Medline search was performed for human studies focusing on augmentation of keratinized tissue and/or soft tissue volume, and complemented by additional hand searching. Relevant studies were identified and statistical results were reported for meta-analyses including the test minus control weighted mean differences with 95% confidence intervals, the I-squared statistic for tests of heterogeneity, and the number of significant studies. RESULTS: Twenty-five (part 1) and three (part 2) studies met the inclusion criteria; 14 studies (part 1) were eligible for comparison using meta-analyses. An apically positioned flap/vestibuloplasty (APF/V) procedure resulted in a statistically significantly greater gain in keratinized tissue than untreated controls. APF/V plus autogenous tissue revealed statistically significantly more attached gingiva compared with untreated controls and a borderline statistical significance compared with APF/V plus allogenic tissue. Statistically significantly more shrinkage was observed for the APF/V plus allogenic graft compared with the APF/V plus autogenous tissue. Patient-centered outcomes did not reveal any of the treatment methods to be superior regarding postoperative complications. The three studies reporting on soft tissue volume augmentation could not be compared due to lack of homogeneity. The use of subepithelial connective tissue grafts (SCTGs) resulted in statistically significantly more soft tissue volume gain compared with free gingival grafts (FGGs). CONCLUSIONS: APF/V is a successful treatment concept to increase the width of keratinized tissue or attached gingiva around teeth. The addition of autogenous tissue statistically significantly increases the width of attached gingiva. For soft tissue volume augmentation, only limited data are available favoring SCTGs over FGG.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: The aim of this systematic review was to analyze the dental literature regarding accuracy and clinical application in computer-guided template-based implant dentistry. Materials and methods: An electronic literature search complemented by manual searching was performed to gather data on accuracy and surgical, biological and prosthetic complications in connection with computer-guided implant treatment. For the assessment of accuracy meta-regression analysis was performed. Complication rates are descriptively summarized. Results: From 3120 titles after the literature search, eight articles met the inclusion criteria regarding accuracy and 10 regarding the clinical performance. Meta-regression analysis revealed a mean deviation at the entry point of 1.07 mm (95% CI: 0.76-1.22 mm) and at the apex of 1.63 mm (95% CI: 1.26-2 mm). No significant differences between the studies were found regarding method of template production or template support and stabilization. Early surgical complications occurred in 9.1%, early prosthetic complications in 18.8% and late prosthetic complications in 12% of the cases. Implant survival rates of 91-100% after an observation time of 12-60 months are reported in six clinical studies with 537 implants mainly restored immediately after flapless implantation procedures. Conclusion: Computer-guided template-based implant placement showed high implant survival rates ranging from 91% to 100%. However, a considerable number of technique-related perioperative complications were observed. Preclinical and clinical studies indicated a reasonable mean accuracy with relatively high maximum deviations. Future research should be directed to increase the number of clinical studies with longer observation periods and to improve the systems in terms of perioperative handling, accuracy and prosthetic complications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: The objective of this systematic review was to assess the 5-year survival rates and incidences of complications associated with ceramic abutments and to compare them with those of metal abutments. METHODS: An electronic Medline search complemented by manual searching was conducted to identify randomized-controlled clinical trials, and prospective and retrospective studies providing information on ceramic and metal abutments with a mean follow-up time of at least 3 years. Patients had to have been examined clinically at the follow-up visit. Assessment of the identified studies and data abstraction was performed independently by three reviewers. Failure rates were analyzed using standard and random-effects Poisson regression models to obtain summary estimates of 5-year survival proportions. RESULTS: Twenty-nine clinical and 22 laboratory studies were selected from an initial yield of 7136 titles and data were extracted. The estimated 5-year survival rate of ceramic abutments was 99.1% [95% confidence interval (CI): 93.8-99.9%] and 97.4% (95% CI: 96-98.3%) for metal abutments. The estimated cumulative incidence of technical complications after 5 years was 6.9% (95% CI: 3.5-13.4%) for ceramic abutments and 15.9% (95% CI: 11.6-21.5%) for metal abutments. Abutment screw loosening was the most frequent technical problem, occurring at an estimated cumulative incidence after 5 years of 5.1% (95% CI: 3.3-7.7%). All-ceramic crowns supported by ceramic abutments exhibited similar annual fracture rates as metal-ceramic crowns supported by metal abutments. The cumulative incidence of biological complications after 5 years was estimated at 5.2% (95% CI: 0.4-52%) for ceramic and 7.7% (95% CI: 4.7-12.5%) for metal abutments. Esthetic complications tended to be more frequent at metal abutments. A meta-analysis of the laboratory data was impossible due to the non-standardized test methods of the studies included. CONCLUSION: The 5-year survival rates estimated from annual failure rates appeared to be similar for ceramic and metal abutments. The information included in this review did not provide evidence for differences of the technical and biological outcomes of ceramic and metal abutments. However, the information for ceramic abutments was limited in the number of studies and abutments analyzed as well as the accrued follow-up time. Standardized methods for the analysis of abutment strength are needed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this systematic review was to assess the survival rates of short-span implant-supported cantilever fixed dental prostheses (ICFDPs) and the incidence of technical and biological complications after an observation period of at least 5 years. MATERIAL AND METHODS: An electronic MEDLINE search supplemented by manual searching was conducted to identify prospective or retrospective cohort studies reporting data of at least 5 years on ICFDPs. Five- and 10-year estimates for failure and complication rates were calculated using standard or random-effect Poisson regression analysis. RESULTS: The five studies eligible for the meta-analysis yielded an estimated 5- and 10-year ICFDP cumulative survival rate of 94.3% [95 percent confidence interval (95% CI): 84.1-98%] and 88.9% (95% CI: 70.8-96.1%), respectively. Five-year estimates for peri-implantitis were 5.4% (95% CI: 2-14.2%) and 9.4% (95% CI: 3.3-25.4%) at implant and prosthesis levels, respectively. Veneer fracture (5-year estimate: 10.3%; 95% CI: 3.9-26.6%) and screw loosening (5-year estimate: 8.2%; 95% CI: 3.9-17%) represented the most common complications, followed by loss of retention (5-year estimate: 5.7%; 95% CI: 1.9-16.5%) and abutment/screw fracture (5-year estimate: 2.1%; 95% CI: 0.9-5.1%). Implant fracture was rare (5-year estimate: 1.3%; 95% CI: 0.2-8.3%); no framework fracture was reported. Radiographic bone level changes did not yield statistically significant differences either at the prosthesis or at the implant levels when comparing ICFDPs with short-span implant-supported end-abutment fixed dental prostheses. CONCLUSIONS: ICFDPs represent a valid treatment modality; no detrimental effects can be expected on bone levels due to the presence of a cantilever extension per se.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: The aim was (1) to evaluate the soft-tissue reaction of a synthetic polyethylene glycol (PEG) hydrogel used as a barrier membrane for guided bone regeneration (GBR) compared with a collagen membrane and (2) to test whether or not the application of this in situ formed membrane will result in a similar amount of bone regeneration as the use of a collagen membrane. MATERIAL AND METHODS: Tooth extraction and preparation of osseous defects were performed in the mandibles of 11 beagle dogs. After 3 months, 44 cylindrical implants were placed within healed dehiscence-type bone defects resulting in approximately 6 mm exposed implant surface. The following four treatment modalities were randomly allocated: PEG+autogenous bone chips, PEG+hydroxyapatite (HA)/tricalcium phosphate (TCP) granules, bioresorbable collagen membrane+autogenous bone chips and autogenous bone chips without a membrane. After 2 and 6 months, six and five dogs were sacrificed, respectively. A semi-quantitative evaluation of the local tolerance and a histomorphometric analysis were performed. For statistical analysis, repeated measures analysis of variance (ANOVA) and subsequent pairwise Student's t-test were applied (P<0.05). RESULTS: No local adverse effects in association with the PEG compared with the collagen membrane was observed clinically and histologically at any time-point. Healing was uneventful and all implants were histologically integrated. Four out of 22 PEG membrane sites revealed a soft-tissue dehiscence after 1-2 weeks that subsequently healed uneventful. Histomorphometric measurement of the vertical bone gain showed after 2 months values between 31% and 45% and after 6 months between 31% and 38%. Bone-to-implant contact (BIC) within the former defect area was similarly high in all groups ranging from 71% to 82% after 2 months and 49% to 91% after 6 months. However, with regard to all evaluated parameters, the PEG and the collagen membranes did not show any statistically significant difference compared with sites treated with autogenous bone without a membrane. CONCLUSION: The in situ forming synthetic membrane made of PEG was safely used in the present study, revealing no biologically significant abnormal soft-tissue reaction and demonstrated similar amounts of newly formed bone for defects treated with the PEG membrane compared with defects treated with a standard collagen membrane.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: This retrospective study reports on histologic and histomorphometric observations performed on human biopsies harvested from sites augmented exclusively by biphasic calcium phosphate [BCP: hydroxyapatite (HA)/ tricalcium phosphate (TCP) 60/40] and healed for a minimum of 6 months. MATERIALS AND METHODS: Five patients benefited from three augmentation regimens (i.e.: one-stage lateral augmentation; two-stage lateral augmentation; and two-stage sinus grafting). In all patients, a degradable collagen membrane served as a cell-occlusive barrier. Core biopsies were obtained from lateral as from crestal aspects 6-10 months after augmentation surgeries. For histologic and histomorphometric evaluations, the non-decalcified tissue processing was performed. RESULTS: The histological examination of 11 biopsies showed graft particles frequently being bridged by the new bone, and a close contact between the graft particles and newly formed bone was seen in all samples. The mean percentages of newly formed bone, soft tissue compartment, and graft material were 38.8% (+/-5.89%), 41.75% (+/-6.08%), and 19.63% (+/-4.85%), respectively. Regarding bone-to-graft contact values, the percentage of bone coverage of graft particles for all biopsies ranged from 27.83% to 80.17%. The mean percentage of bone coverage was 55.39% (+/-13.03%). CONCLUSIONS: Data from the present study demonstrated osteoconductivity scores for the BCP material (HA/TCP 60/40) in patients resembling those previously shown for grafting materials of xenogenic and alloplastic origin.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Although considerable bone fill may occur following treatment of peri-implantitis, re-osseointegration appears to be limited and unpredictable. Objectives: To evaluate the effects of various decontamination techniques and implant surface configurations on re-osseointegration of contaminated dental implants. MATERIAL AND METHODS: Three months after tooth extraction, implants consisting of a basal part and an exchangeable intraosseous implant cylinder (EIIC) were placed in the mandibles of dogs. The EIIC was machined (M), sandblasted and acid-etched (SLA), or titanium plasma sprayed (TPS). Ligature-induced peri-implantitis was initiated 8 weeks post-implantation and lasted until bone loss reached the junction of the two implant parts. Three treatment modalities were applied: (T1) the EIIC was exchanged for a pristine EIIC; (T2) the EIIC was sprayed in situ with saline; and (T3) the EIIC was removed, cleansed outside the mouth by spraying with saline, steam-sterilized, and remounted. A collagen barrier was placed over each fixture, and 3 months later, samples were processed for histology and histomorphometry. RESULTS: T2 revealed the highest bone-to-implant contact (BIC) level (significantly better than T1 and T3). T2 also yielded the highest bone crest level (significantly better than T1), followed by T3 (significantly better than T1). SLA showed the highest BIC level (significantly better than M), followed by TPS. There were no statistically significant differences in bone crest height between implant types. CONCLUSIONS: Both SLA implants and in situ cleansing resulted in the best re-osseointegration and bone fill of previously contaminated implants.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: To assess retrospectively the cumulative costs for the long-term oral rehabilitation of patients with birth defects affecting the development of teeth. METHODS: Patients with birth defects who had received fixed reconstructions on teeth and/or implants > or =5 years ago were asked to participate in a comprehensive clinical, radiographic and economic evaluation. RESULTS: From the 45 patients included, 18 were cases with a cleft lip and palate, five had amelogenesis/dentinogenesis imperfecta and 22 were cases with hypodontia/oligodontia. The initial costs for the first oral rehabilitation (before the age of 20) had been covered by the Swiss Insurance for Disability. The costs for the initial rehabilitation of the 45 cases amounted to 407,584 CHF (39% for laboratory fees). Linear regression analyses for the initial treatment costs per replaced tooth revealed the formula 731 CHF+(811 CHF x units) on teeth and 3369 CHF+(1183 CHF x units) for reconstructions on implants (P<.001). Fifty-eight percent of the patients with tooth-supported reconstructions remained free from failures/complications (median observation 15.7 years). Forty-seven percent of the patients with implant-supported reconstructions remained free from failures/complications (median observation 8 years). The long-term cumulative treatment costs for implant cases, however, were not statistically significantly different compared with cases reconstructed with tooth-supported fixed reconstructions. Twenty-seven percent of the initial treatment costs were needed to cover supportive periodontal therapy as well as the treatment of technical/biological complications and failures. CONCLUSION: Insurance companies should accept to cover implant-supported reconstructions because there is no need to prepare healthy teeth, fewer tooth units need to be replaced and the cumulative long-term costs seem to be similar compared with cases restored on teeth.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIM: The aim of this study was to assess the marginal fit of crowns on the Straumann (ITI) Dental Implant System with special consideration of different casting dental materials. MATERIAL AND METHODS: Sixty porcelain-fused-to-metal crowns were fabricated: 18 crowns on standard cone abutments with an impression cylinder, partially prefabricated analogs, no coping and screw-retained (A); 18 crowns on solid abutments without an impression device, no analogs, no coping and cemented (B); and 18 crowns on solid abutments using an impression transfer cap, an analog with a shoulder, no coping and cemented (C). In each group, six crowns were made on epoxy mastercasts (Bluestar), six on synthetic plaster (Moldasynt) and six on super hard stone (Fujirock). Six additional crowns were fabricated with the transversal screw retention system onto the Octa system with impression transfer caps, metal analogs, gold copings and screw-retained (D). Impregum was used as impression material. Crowns of B and C were cemented with KetacCem. Crowns of A and D were fixed with an occlusal screw torqued at 15 N cm. Crowns were embedded, cut and polished. Under a light microscope using a magnification of x 100, the distance between the crown margin (CM) and the shoulder (marginal gap, MG) and the distance between the CM and the end of the shoulder (crown length, CL) was measured. RESULTS: MGs were 15.4+/-13.2 microm (A), 21.2+/-23.1 microm (B), 11+/-12.1 microm (C) and 10.4+/-9.3 microm (D). No statistically significantly differences using either of the casting materials were observed. CLs were -21.3+/-24.8 microm (A), 3+/-28.9 microm (B), 0.5+/-22 microm (C) and 0.1+/-15.8 microm (D). Crowns were shorter on synthetic casting materials compared with stone casts (P<0.005). CONCLUSIONS: CMs fit precisely with both cemented and screw-retained versions as well as when using no, partial or full analogs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIM: To assess dimensional ridge alterations following immediate implant placement in molar extraction sites. MATERIAL AND METHODS: Twelve subjects received 12 immediate transmucosal implants in molar extraction sites. Peri-implant defects were treated according to the principles of Guided Bone Regeneration by means of a deproteinized bone substitute and a bioresorbable collagen membrane. Changes in vertical (IS-BD, CREST-BD) and horizontal distances (EC-I, IC-I) of alveolar bony walls to the bottom of the defects (BD) and to the implant surfaces (I) were compared between implant placement and surgical re-entry at 6 months. RESULTS: The implant survival rate at 6 months was 100%. Statistically significant differences (P<0.01) were observed in the mean changes in vertical distances IS-BD and CREST-BD between baseline and re-entry. At re-entry, all peri-implant marginal defects assessed from the internal socket wall to the implant surface (IC-I) were healed. The residual combined thickness of the buccal wall with the newly formed peri-implant bone at sites with an initial thickness of 1 mm was statistically significantly smaller (P<0.05) compared with that of sites with an initial buccal thickness of 2 mm (2.50 +/- 0.76 vs. 4+/-0 mm). CONCLUSIONS: The marginal defects around immediate implants placed in molar extraction sites were completely filled after 6 months of healing through de novo bone formation. Bone resorption was observed from the external aspects of the buccal and oral socket walls. Dimensional changes of the external socket walls were mostly pronounced at the buccal aspects.