505 resultados para Octavius 4D
Resumo:
Purpose. To investigate the robustness of single vocal cord intensity modulated radiation therapy (IMRT) treatment plans for set-up errors, respiration, and deformation. Material and methods. Four-dimensional computed tomography (4D-CT) scans of 10 early glottic carcinoma patients, previously treated with conventional techniques, were used in this simulation study. For each patient a pre-treatment 4D-CT was used for IMRT planning, generating a reference dose distribution. Prescribed PTV dose was 66 Gy. The impact of systematic set-up errors was simulated by applying shifts of ± 2 mm to the planning CT scans, followed by dose re-calculation with original beam segments, MUs, etc. Effects of respiration and deformation were determined utilizing extreme inhale and exhale CT scans, and repeat scans acquired after 22 Gy, 44 Gy, and 66 Gy, respectively. All doses were calculated using Monte Carlo dose simulations. Results. Considering all investigated geometrical perturbations, reductions in the clinical target volume (CTV) V95%, D98%, D2%, and generalized equivalent uniform dose (gEUD) were limited to 1.2 ± 2.2%, 2.4 ± 2.9%, 0.2 ± 1.8%, and 0.6 ± 1.1 Gy, respectively. The near minimum dose, D98%, was always higher than 89%, and gEUD always remained higher than 66 Gy. Planned contra-lateral (CL) vocal cord DMean, gEUD, and V40 Gy were 38.2 ± 6.0 Gy, 43.4 ± 5.6 Gy, and 42.7 ± 14.9%. With perturbations these values changed by -0.1 ± 4.3 Gy, 0.1 ± 4.0 Gy, and -1.0 ± 9.6%, respectively. Conclusions. On average, CTV dose reductions due to geometrical perturbations were very low, and sparing of the CL vocal cord was maintained. In a few observations (6 of 103 simulated situations), the near-minimum CTV-dose was around 90%, requiring attention in deciding on a future clinical protocol.
Resumo:
INTRODUCTION: The treatment of choice for early glottic cancer is still being debated; ultimately it relies on the functional outcome. This paper reports on a novel sparing 4D conformal technique for single vocal cord irradiation (SVCI).
MATERIAL AND METHODS: The records of 164 T1a patients with SCC of the vocal cord, irradiated in the Erasmus MC between 2000 and 2008, were analyzed for local control and overall survival. The quality of life was determined by EORTC H&N35 questionnaires. Also the VHI (voice handicap index), and the TSH (thyroid stimulating hormone) blood levels, were established. On-line image guided SVCI, using cone beam CT or stereotactic radiation therapy (SRT) techniques, were developed.
RESULTS: A LC rate at five-years of 93% and a VHI of 12.7 (0-63) was determined. It appeared feasible to irradiate one vocal cord within 1-2mm accuracy. This way sparing of the contralateral (CL) vocal cord and CL normal tissues, could be achieved.
CONCLUSIONS: Given the accuracy (1-2mm) and small volume disease (CTV limited to one vocal cord), for the use of stereotactic RT techniques SVCI with large fraction sizes is currently being investigated in clinic. It is argued that hypofractionated SVCI can be a competitive alternative to laser surgery.
Resumo:
Background and Purpose: To quantify respiratory motion of the vocal cords during normal respiration using 4D-CT. The final goal is to develop a technique for single vocal cord irradiation (SVCI) in early glottic carcinoma. Sparing the non-involved cord and surrounding structures has the potential to preserve voice quality and allow re-irradiation of recurrent and second primary tumors. Material and methods: Four-dimensional CTs of 1 mm slice thickness from 10 early glottic carcinoma patients were acquired. The lateral dimensions of the air gap separating the vocal cords were measured anteriorly, at mid-level and posteriorly at each phase of the 4D-CTs. The corresponding anterior-posterior gaps were similarly measured. Cranio-caudal vocal cords movements during breathing were derived from the shifts of the arythenoids. Results: The population-averaged mean gap size ± the corresponding standard deviation due to breathing (SDB) for the lateral gaps was 5.8 ± 0.7 mm anteriorly, 8.7 ± 0.9 mm at mid-level, and 11.0 ± 1.3 mm posteriorly. Anterior-posterior gap values were 21.7 ± 0.7 mm, while cranio-caudal shift SDB was 0.8 mm. Conclusion: Vocal cords breathing motions were found to be small relative to their separation. Hence, breathing motion does not seem to be a limiting factor for SVCI. © 2008 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Energies and lifetimes are reported for the lowest 375 levels of five Br-like ions, namely SrIV, YV, ZrVI, NbVII, and MoVIII, mostly belonging to the 4s<sup>2</sup>4p<sup>5</sup>, 4s<sup>2</sup>4p<sup>4</sup>4ℓ, 4s4p<sup>6</sup>, 4s<sup>2</sup>4p<sup>4</sup>5ℓ, 4s<sup>2</sup>4p<sup>3</sup>4d<sup>2</sup>, 4s4p<sup>5</sup>4ℓ, and 4s4p<sup>5</sup>5ℓ configurations. Extensive configuration interaction has been included and the general-purpose relativistic atomic structure package (grasp) has been adopted for the calculations. Additionally, radiative rates are listed among these levels for all E1, E2, M1, and M2 transitions. From a comparison with the measurements, the majority of our energy levels are assessed to be accurate to better than 2%, although discrepancies between theory and experiment for a few are up to 6%. An accuracy assessment of the calculated radiative rates (and lifetimes) is more difficult, because no prior results exist for these ions.
Resumo:
Energy levels and radiative rates for transitions in five Br-like ions (Sr IV, Y V, Zr VI, Nb VII and Mo VIII) are calculated with the general-purpose relativistic atomic structure package (GRASP). Extensive configuration interaction has been included and results are presented among the lowest 31 levels of the 4s24p5, 4s24p44d and 4s4p6 configurations. Lifetimes for these levels have also been determined, although unfortunately no measurements are available with which to compare. However, recently theoretical results have been reported by Singh et al (2013 Phys. Scr. 88 035301) using the same GRASP code. But their reported data for radiative rates and lifetimes cannot be reproduced and show discrepancies of up to five orders of magnitude with the present calculations.
Resumo:
Energy levels and radiative rates are reported for transitions in Br-like tungsten, W XL, calculated with the general-purpose relativistic atomic structure package (grasp). Configuration interaction (CI) has been included among 46 configurations (generating 4215 levels) over a wide energy range up to 213 Ryd. However, for conciseness results are only listed for the lowest 360 levels (with energies up to ~43 Ryd), which mainly belong to the 4s24p5,4s24p44d,4s24p44f,4s4p6,4p64d,4s4p54d,4s24p34d2, and 4s24p34d4f configurations, and provided for four types of transitions, E1, E2, M1, and M2. Comparisons are made with existing (but limited) results. However, to fully assess the accuracy of our data, analogous calculations have been performed with the flexible atomic code, including an even larger CI than in grasp. Our energy levels are estimated to be accurate to better than 0.02 Ryd, whereas results for radiative rates (and lifetimes) should be accurate to better than 20% for a majority of the strong transitions.
Resumo:
OBJECTIVE: To demonstrate the benefit of complexity metrics such as the modulation complexity score (MCS) and monitor units (MUs) in multi-institutional audits of volumetric-modulated arc therapy (VMAT) delivery.
METHODS: 39 VMAT treatment plans were analysed using MCS and MU. A virtual phantom planning exercise was planned and independently measured using the PTW Octavius(®) phantom and seven29(®) 2D array (PTW-Freiburg GmbH, Freiburg, Germany). MCS and MU were compared with the median gamma index pass rates (2%/2 and 3%/3 mm) and plan quality. The treatment planning systems (TPS) were grouped by VMAT modelling being specifically designed for the linear accelerator manufacturer's own treatment delivery system (Type 1) or independent of vendor for VMAT delivery (Type 2). Differences in plan complexity (MCS and MU) between TPS types were compared.
RESULTS: For Varian(®) linear accelerators (Varian(®) Medical Systems, Inc., Palo Alto, CA), MCS and MU were significantly correlated with gamma pass rates. Type 2 TPS created poorer quality, more complex plans with significantly higher MUs and MCS than Type 1 TPS. Plan quality was significantly correlated with MU for Type 2 plans. A statistically significant correlation was observed between MU and MCS for all plans (R = -0.84, p < 0.01).
CONCLUSION: MU and MCS have a role in assessing plan complexity in audits along with plan quality metrics. Plan complexity metrics give some indication of plan deliverability but should be analysed with plan quality.
ADVANCES IN KNOWLEDGE: Complexity metrics were investigated for a national rotational audit involving 34 institutions and they showed value. The metrics found that more complex plans were created for planning systems which were independent of vendor for VMAT delivery.
Resumo:
For a number of years, there has been a major effort to calculate electron-impact excitation data for every ion stage of iron embodied by the ongoing efforts of the IRON project by Hummer et al (1993 Astron. Astrophys. 279 298). Due to the complexity of the targets, calculations for the lower stages of ionization have been limited to either intermediate-coupling calculations within the ground configurations or LS -coupling calculations of the ground and excited configurations. However, accurate excitation data between individual levels within both the ground and excited configurations of the low charge-state ions are urgently required for applications to both astrophysical and laboratory plasmas. Here we report on the results of the first intermediate-coupling R -matrix calculation of electron-impact excitation for Fe 4+ for which the close-coupling (CC) expansion includes not only those levels of the 3d 4 ground configuration, but also the levels of the 3d 3 4s, 3d 3 4p, 3d 3 4d and 3d 2 4s 2 excited configurations. With 359 levels in the CC expansion and over 2400 scattering channels for many of the J Π partial waves, this represents the largest electron–ion scattering calculation to date and it was performed on massively parallel computers using a recently developed set of relativistic parallel R -matrix programs.
Resumo:
Accurate data for dielectronic recombination (DR) of the ions of tungsten are of significant interest in the modelling of tungsten impurity transport and radiative power loss in current tokamaks and in ITER. However, the complexity of the atomic structure for many of these ions makes level-resolved DR calculations untenable on currently available computers, especially for open d- and f-subshell ions. The majority of DR data presently available for ITER modelling are based on an average-atom approximation. To improve upon these baseline calculations, we investigate the use of the configuration-average distorted-wave (CADW) method to calculate DR rate coefficients for complex open d-shell systems. The aim is to produce rate coefficients that are sufficiently accurate in terms of modelling, yet greatly reduced in term of computational complexity compared to level-resolved calculations. In this paper, we consider the DR of W 35 + . Initially, we carry out several large-scale level-resolved calculations for the DR associated with the 4d → 4f and 4p → 4d excitations in this ion, using both the level-resolved distorted-wave and Dirac R -matrix methods. These calculations allow us to test the validity of the CADW approach on these same excitations by comparing cross sections and rate coefficients. These comparisons demonstrate that the CADW method is relatively accurate in relation to these level-resolved methods for the temperature range for which W 35 + should exist in a collisionally ionized plasma. We then present results for CADW rate coefficients for both Δ n = 0 and Δ n = 1 excitations for this ion. This study indicates that it is now feasible to generate a much improved comprehensive set of DR data for the entire tungsten isonuclear sequence.
Resumo:
Double photoionization accompanied by loss of n C atoms (n=0, 2, 4, 6) was investigated by merging beams of Xe@C60+ ions and synchrotron radiation and measuring the yields of product ions. The giant 4d dipole resonance of the caged Xe atom has a prominent signature in the cross section for these product channels, which together account for 6.2 ± 1.4 of the total Xe 4d oscillator strength of 10. Compared to that for a free Xe atom, the oscillator strength is redistributed in photon energy due to multipath interference of outgoing Xe 4d photoelectron waves that may be transmitted or reflected by the spherical C60+ molecular cage, yielding so-called confinement resonances. The data are compared with an earlier measurement and with theoretical predictions for this single-molecule photoelectron interferometer system. Relativistic R-matrix calculations for the Xe atom in a spherical potential shell representing the fullerene cage show the sensitivity of the interference pattern to the molecular geometry. © 2013 American Physical Society.
Resumo:
Aims. We present rates for all E1, E2, M1, and M2 transitions among the 295 fine-structure levels of the configurations 3d9, 3d84s, 3d74s2, 3d84p, and 3d74s4p, determined through an extensive configuration interaction calculation.
Methods. The CIV3 code developed by Hibbert and coworkers is used to determine for these levels configuration interaction wave functions with relativistic effects introduced through the Breit-Pauli approximation.
Results. Two different sets of calculations have been undertaken with different 3d and 4d functions to ascertain the effect of such variation. The main body of the text includes a representative selection of data, chosen so that key points can be discussed. Some analysis to assess the accuracy of the present data has been undertaken, including comparison with earlier calculations and the more limited range of experimental determinations. The full set of transition data is given in the supplementary material as it is very extensive.
Conclusions. We believe that the present transition data are the best currently available.
Resumo:
Für das digitale Flugführungssystem des Versuchsflugzeugs HFB 320 wurde am Institut für Flugführung der DFVLR in Braunschweig eine Betriebsart zum automatischen zeitgenauen Fliegen im Flughafen-Nahbereich entwickelt und im Flugversuch erprobt. Der Bericht enthält die Beschreibung der eingesetzten Algorithmen zur Berechnung 4-dimensionaler Flugbahnen unter Berücksichtigung der momentanen Windsituation. Es werden verschiedene Verfahren zur Messung, Filterung und Vorhersage des Windvektors entwickelt und an Hand von Flugversuchsergebnissen diskutiert.
Resumo:
O ser humano realiza uma alimentação pouco variada, com grandes teores de açúcar e gorduras saturadas, ao mesmo tempo, está sujeito a profissões cada vez mais competitivas aonde passa longos períodos sentados sem qualquer esforço físico. Estes aspetos levam à acumulação de gorduras em redor de todos os órgãos, que promovem o aparecimento de problemas cardiovascular, que são atualmente, a principal causa de morte no mundo. O tratamento das doenças cardiovasculares é em muitas situações realizado por procedimentos minimamente-invasivos, que são guiados através de imagem médica. Contudo, a utilização de radiação durante a navegação é normalmente requerida o que tem consequências para o paciente e para a equipa médica. Nesta dissertação, focamo-nos nos recentes sistemas de aquisição de imagem sem radiação e no desenvolvimento de sistemas mais inteligentes para facilitar o controlo destes equipamentos durante o procedimento. Assim, pretendemos desenvolver um robô que apoie na aquisição de imagens de ultrassons através de uma sonda transesofágica. O robô desenvolvido possui um conjunto de engrenagens que fazem a transferência de movimento para as rodas dos manípulos da sonda e um encoder magnético que proporciona uma leitura rápida e de alta precisão dos movimentos da sonda. De forma a automaticamente adaptar a posição da sonda na direção do alvo anatómico, um sistema de motion tracking foi acoplado ao robô e ao instrumento cirúrgico utilizado durante o procedimento. Assim, todos os movimentos realizados pelo intervencionista são repetidos pela sonda, permitindo assim adquirir uma imagem de ultrassom sempre centrada no instrumento cirúrgico. Para avaliar a performance do robô foram realizados testes em laboratório. mais concretamente: 1) controlo do robô sem sonda acoplada e 2) controlo do robô com sonda acoplada. Os testes foram realizados com diferentes posições angulares, em todas as gamas de funcionamento do robô, avaliando o erro da posição final em relação posição desejada e o tempo de resposta. Os resultados demonstraram que um erro médio de 2º foi observado para as diferentes situações com um tempo médio de resposta de 300 ms. Os resultados alcançados demonstraram uma boa resposta do sistema, pelo que se espera que sistema desenvolvido venha ser capaz de reduzir o tempo de intervenção, aumentando a qualidade da intervenção e minimizando possíveis erros.
Resumo:
Durante el 2010, se capturó 55 ejemplares de tortuga verde Chelonia mydas en La Aguada (13°51’S y 76°15’W) al sureste de la bahía de Paracas; el número promedio de tortugas capturadas por kilómetro de red tendida fue 3,08±2,5; el tamaño promedio de la LCC fue 60,3±10,5cm; el 78% de los ejemplares presentaron el patrón 5c, 4d, 4i y 11d, 11i, para los escudos centrales, costales y marginales, respectivamente. La TSM donde se capturaron varió entre 15,2 y 20,9 °C, la mayor ocurrencia de tortugas se registró de 18,5 a 20 °C. Los epibiontes más representativos fueron Platylepas hexastylos (56,8%), Conchoderma virgatum (26,9%) y Chelonibia testudinaria (13,3%); la ocurrencia de los ítems alimenticios: Clorophyta (78%), Rhodophyta (30%), Cnidaria (43%), Crustacea (43%), Polichaeta (17%), Mollusca (17%), arena (26%) y plástico (17%); el 72% de las tortugas presentaron cobertura algal, de las cuales el 65% fue el alga verde Enteromorpha sp.
Resumo:
Existing research on attraction to body features has suggested that men show general preferences for women with lower waist-to-hip ratios (WHR), larger breasts, and slender body weights. The present study intended to expand on this research by investigating several individual difference factors and their potential contribution to variation in what men find attractive in female body features. Two hundred and seventy-three men were assessed for sex-role identity, 2D:4D digit ratios (a possible marker of prenatal exposure to androgens, and thus masculinization), physical attractiveness, early sexual experiences (as indices of early sexual conditioning), and early family attitudes toward body features, as well as their current preferences for WHR, breast size, weight, and height in women. For WHR, as predicted, physical attractiveness, early sexual experiences, and lower (more masculine) right-hand 2D:4D ratios significantly predicted current preferences for more feminine (lower) WHR. Early sexual experiences significantly predicted later preferences for breast size; in addition, more masculine occupational preferences and lower (more masculine) left-hand 2D:4D ratios predicted preferences for larger breasts. Participants' height, education level, Unmitigated Agency (masculinity) scores, and early sexual experiences significantly predicted current preferences for height. Finally, early sexual experiences significantly predicted current preferences for weight. The results suggest that variation in preferences for women's bodily features can be uniquely accounted for by a number of individual difference factors. Strengths and weaknesses of the study, along with implications for future research, are discussed.