912 resultados para Non destructive testing


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Following the success achieved in previous research projects usin non-destructive methods to estimate the physical and mechanical aging of particle and fibre boards, this paper studies the relationships between aging, physical and mechanical changes, using non-destructive measurements of oriented strand board (OSB). 184 pieces of OSB board from a French source were tested to analyze its actual physical and mechanical properties. The same properties were estimated using acoustic non-destructive methods (ultrasound and stress wave velocity) during a physical laboratory aging test. Measurements were recorded of propagation wave velocity with the sensors aligned, edge to edge, and forming an angle of 45 degrees, with both sensors on the same face of the board. This is because aligned measures are not possible on site. The velocity results are always higher in 45 degree measurements. Given the results of statistical analysis, it can be concluded that there is a strong relationship between acoustic measurements and the decline in physical and mechanical properties of the panels due to aging. The authors propose several models to estimate the physical and mechanical properties of board, as well as their degree of aging. The best results are obtained using ultrasound, although the difference in comparison with the stress wave method is not very significant. A reliable prediction of the degree of deterioration (aging) of board is presented.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

La termografía es un método de inspección y diagnóstico basado en la radiación infrarroja que emiten los cuerpos. Permite medir dicha radiación a distancia y sin contacto, obteniendo un termograma o imagen termográfica, objeto de estudio de este proyecto. Todos los cuerpos que se encuentren a una cierta temperatura emiten radiación infrarroja. Sin embargo, para hacer una inspección termográfica hay que tener en cuenta la emisividad de los cuerpos, capacidad que tienen de emitir radiación, ya que ésta no sólo depende de la temperatura del cuerpo, sino también de sus características superficiales. Las herramientas necesarias para conseguir un termograma son principalmente una cámara termográfica y un software que permita su análisis. La cámara percibe la emisión infrarroja de un objeto y lo convierte en una imagen visible, originalmente monocromática. Sin embargo, después es coloreada por la propia cámara o por un software para una interpretación más fácil del termograma. Para obtener estas imágenes termográficas existen varias técnicas, que se diferencian en cómo la energía calorífica se transfiere al cuerpo. Estas técnicas se clasifican en termografía pasiva, activa y vibrotermografía. El método que se utiliza en cada caso depende de las características térmicas del cuerpo, del tipo de defecto a localizar o la resolución espacial de las imágenes, entre otros factores. Para analizar las imágenes y así obtener diagnósticos y detectar defectos, es importante la precisión. Por ello existe un procesado de las imágenes, para minimizar los efectos provocados por causas externas, mejorar la calidad de la imagen y extraer información de las inspecciones realizadas. La termografía es un método de ensayo no destructivo muy flexible y que ofrece muchas ventajas. Por esta razón el campo de aplicación es muy amplio, abarcando desde aplicaciones industriales hasta investigación y desarrollo. Vigilancia y seguridad, ahorro energético, medicina o medio ambiente, son algunos de los campos donde la termografía aportaimportantes beneficios. Este proyecto es un estudio teórico de la termografía, donde se describen detalladamente cada uno de los aspectos mencionados. Concluye con una aplicación práctica, creando una cámara infrarroja a partir de una webcam, y realizando un análisis de las imágenes obtenidas con ella. Con esto se demuestran algunas de las teorías explicadas, así como la posibilidad de reconocer objetos mediante la termografía. Thermography is a method of testing and diagnosis based on the infrared radiation emitted by bodies. It allows to measure this radiation from a distance and with no contact, getting a thermogram or thermal image, object of study of this project. All bodies that are at a certain temperature emit infrared radiation. However, making a thermographic inspection must take into account the emissivity of the body, capability of emitting radiation. This not only depends on the temperature of the body, but also on its surface characteristics. The tools needed to get a thermogram are mainly a thermal imaging camera and software that allows analysis. The camera sees the infrared emission of an object and converts it into a visible image, originally monochrome. However, after it is colored by the camera or software for easier interpretation of thermogram. To obtain these thermal images it exists various techniques, which differ in how heat energy is transferred to the body. These techniques are classified into passive thermography, active and vibrotermografy. The method used in each case depends on the thermal characteristics of the body, the type of defect to locate or spatial resolution of images, among other factors. To analyze the images and obtain diagnoses and defects, accuracy is important. Thus there is a image processing to minimize the effects caused by external causes, improving image quality and extract information from inspections. Thermography is a non-­‐destructive test method very flexible and offers many advantages. So the scope is very wide, ranging from industrial applications to research and development.Surveillance and security, energy saving, environmental or medicine are some of the areas where thermography provides significant benefits. This project is a theoretical study of thermography, which describes in detail each of these aspects. It concludes with a practical application, creating an infrared camera from a webcam, and making an analysis of the images obtained with it. This will demonstrate some of the theories explained as well as the ability to recognize objects by thermography.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Ultrasonic sound velocity measurements with hand-held equipment remain due to their simplicity among the most used methods for non-destructive grading of sawn woods, yet a dedicated normalization effort with respect to strength classes for Spanish species is still required. As part of an ongoing project with the aim of definition of standard testing methods, the effect of the dimensions of commonly tested Scots pine (Pinus sylvestris L.) timbers and equipment testing frequency on ultrasonic velocity were investigated. A dedicated full-wave finite-difference time-domain software allowed simulation of pulse propagation through timbers of representative length and section combinations. Sound velocity measurements vL were performed along the grain with the indirect method at 22 kHz and 45 kHz for grids of measurement points at specific distances. For sample sections larger than the cross-sectional wavelength ?RT, the simulated sound velocity vL converges to vL = (CL/?)0.5. For smaller square sections the sound velocity drops down to vL = (EL/?)0.5, where CL, EL and ? are the stiffness, E-modul and density, respectively. The experiments confirm a linear regression between time of flight and measurement distance even at less than two wavelength menor que2?L distance, the fitted sound speed values increased by 15% between the two tested frequencies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

La artroplastia de cadera se considera uno de los mayores avances quirúrgicos de la Medicina. La aplicación de esta técnica de Traumatología se ha incrementado notablemente en los últimos anos, a causa principalmente del progresivo incremento de la esperanza de vida. En efecto, con la edad aumentan los problemas de artrosis y osteoporosis, enfermedades típicas de las articulaciones y de los huesos que requieren en muchos casos la sustitución protésica total o parcial de la articulación. El buen comportamiento funcional de una prótesis depende en gran medida de la estabilidad primaria, es decir, el correcto anclaje de la prótesis en el momento de su implantación. Las prótesis no cementadas basan su éxito a largo plazo en la osteointegración que tiene lugar entre el material protésico y el tejido óseo, y para lograrla es imprescindible conseguir unas buenas condiciones de estabilidad primaria. El aflojamiento aséptico es la principal causa de fallo de artroplastia total de cadera. Este es un fenómeno en el que, debido a complejas interacciones de factores mecánicos y biológicos, se producen movimientos relativos que comprometen la funcionalidad del implante. La minimización de los correspondientes danos depende en gran medida de la detección precoz del aflojamiento. Para lograr la detección temprana del aflojamiento aséptico del vástago femoral se han ensayado diferentes técnicas, tanto in vivo como in vitro: análisis numéricos y técnicas experimentales basadas en sensores de movimientos provocados por cargas transmitidas natural o artificialmente, tales como impactos o vibraciones de distintas frecuencias. Los montajes y procedimientos aplicados son heterogéneos y, en muchas ocasiones, complejos y costosos, no existiendo acuerdo sobre una técnica simple y eficaz de aplicación general. Asimismo, en la normativa vigente que regula las condiciones que debe cumplir una prótesis previamente a su comercialización, no hay ningún apartado referido específicamente a la evaluación de la bondad del diseño del vástago femoral con respecto a la estabilidad primaria. El objetivo de esta tesis es desarrollar una metodología para el análisis, in vitro, de la estabilidad de un vástago femoral implantado, a fin de poder evaluar las técnicas de implantación y los diferentes diseños de prótesis previamente a su oferta en el mercado. Además se plantea como requisito fundamental que el método desarrollado sea sencillo, reversible, repetible, no destructivo, con control riguroso de parámetros (condiciones de contorno de cargas y desplazamientos) y con un sistema de registro e interpretación de resultados rápido, fiable y asequible. Como paso previo, se ha realizado un análisis cualitativo del problema de contacto en la interfaz hueso-vástago aplicando una técnica optomecánica del campo continuo (fotoelasticidad). Para ello se han fabricado tres modelos en 2D del conjunto hueso-vástago, simulando tres tipos de contactos en la interfaz: contacto sin adherencia y con holgura, contacto sin adherencia y sin holgura, y contacto con adherencia y homogéneo. Aplicando la misma carga a cada modelo, y empleando la técnica de congelación de tensiones, se han visualizado los correspondientes estados tensionales, siendo estos más severos en el modelo de unión sin adherencia, como cabía esperar. En todo caso, los resultados son ilustrativos de la complejidad del problema de contacto y confirman la conveniencia y necesidad de la vía experimental para el estudio del problema. Seguidamente se ha planteado un ensayo dinámico de oscilaciones libres con instrumentación de sensores resistivos tipo galga extensométrica. Las muestras de ensayo han sido huesos fémur en todas sus posibles variantes: modelos simplificados, hueso sintético normalizado y hueso de cadáver, seco y fresco. Se ha diseñado un sistema de empotramiento del extremo distal de la muestra (fémur) con control riguroso de las condiciones de anclaje. La oscilación libre de la muestra se ha obtenido mediante la liberación instantánea de una carga estética determinada y aplicada previamente, bien con una maquina de ensayo o bien por gravedad. Cada muestra se ha instrumentado con galgas extensométricas convencionales cuya señal se ha registrado con un equipo dinámico comercial. Se ha aplicado un procedimiento de tratamiento de señal para acotar, filtrar y presentar las respuestas de los sensores en el dominio del tiempo y de la frecuencia. La interpretación de resultados es de tipo comparativo: se aplica el ensayo a una muestra de fémur Intacto que se toma de referencia, y a continuación se repite el ensayo sobre la misma muestra con una prótesis implantada; la comparación de resultados permite establecer conclusiones inmediatas sobre los efectos de la implantación de la prótesis. La implantación ha sido realizada por un cirujano traumatólogo utilizando las mismas técnicas e instrumental empleadas en el quirófano durante la práctica clínica real, y se ha trabajado con tres vástagos femorales comerciales. Con los resultados en el dominio del tiempo y de la frecuencia de las distintas aplicaciones se han establecido conclusiones sobre los siguientes aspectos: Viabilidad de los distintos tipos de muestras sintéticas: modelos simplificados y fémur sintético normalizado. Repetibilidad, linealidad y reversibilidad del ensayo. Congruencia de resultados con los valores teóricos deducidos de la teoría de oscilaciones libres de barras. Efectos de la implantación de tallos femorales en la amplitud de las oscilaciones, amortiguamiento y frecuencias de oscilación. Detección de armónicos asociados a la micromovilidad. La metodología se ha demostrado apta para ser incorporada a la normativa de prótesis, es de aplicación universal y abre vías para el análisis de la detección y caracterización de la micromovilidad de una prótesis frente a las cargas de servicio. ABSTRACT Total hip arthroplasty is considered as one of the greatest surgical advances in medicine. The application of this technique on Traumatology has increased significantly in recent years, mainly due to the progressive increase in life expectancy. In fact, advanced age increases osteoarthritis and osteoporosis problems, which are typical diseases of joints and bones, and in many cases require full or partial prosthetic replacement on the joint. Right functional behavior of prosthesis is highly dependent on the primary stability; this means it depends on the correct anchoring of the prosthesis at the time of implantation. Uncemented prosthesis base their long-term success on the quality of osseointegration that takes place between the prosthetic material and bone tissue, and to achieve this good primary stability conditions is mandatory. Aseptic loosening is the main cause of failure in total hip arthroplasty. This is a phenomenon in which relative movements occur, due to complex interactions of mechanical and biological factors, and these micromovements put the implant functionality at risk. To minimize possible damage, it greatly depends on the early detection of loosening. For this purpose, various techniques have been tested both in vivo and in vitro: numerical analysis and experimental techniques based on sensors for movements caused by naturally or artificially transmitted loads, such as impacts or vibrations at different frequencies. The assemblies and methods applied are heterogeneous and, in many cases, they are complex and expensive, with no agreement on the use of a simple and effective technique for general purposes. Likewise, in current regulations for governing the conditions to be fulfilled by the prosthesis before going to market, there is no specific section related to the evaluation of the femoral stem design in relation to primary stability. The aim of this thesis is to develop a in vitro methodology for analyzing the stability of an implanted femoral stem, in order to assess the implantation techniques and the different prosthesis designs prior to its offer in the market. We also propose as a fundamental requirement that the developed testing method should be simple, reversible, repeatable, non-destructive, with close monitoring of parameters (boundary conditions of loads and displacements) and with the availability of a register system to record and interpret results in a fast, reliable and affordable manner. As a preliminary step, we have performed a qualitative analysis of the contact problems in the bone-stem interface, through the application of a continuous field optomechanical technique (photoelasticity). For this proposal three 2D models of bone–stem set, has been built simulating three interface contact types: loosened an unbounded contact, unbounded and fixed contact, and bounded homogeneous contact. By means of applying the same load to each model, and using the stress freezing technique, it has displayed the corresponding stress states, being more severe as expected, in the unbounded union model. In any case, the results clearly show the complexity of the interface contact problem, and they confirm the need for experimental studies about this problem. Afterward a free oscillation dynamic test has been done using resistive strain gauge sensors. Test samples have been femur bones in all possible variants: simplified models, standardized synthetic bone, and dry and cool cadaveric bones. An embedding system at the distal end of the sample with strong control of the anchoring conditions has been designed. The free oscillation of the sample has been obtained by the instantaneous release of a static load, which was previously determined and applied to the sample through a testing machine or using the gravity force. Each sample was equipped with conventional strain gauges whose signal is registered with a marketed dynamic equipment. Then, it has applied a signal processing procedure to delimit, filter and present the time and frequency response signals from the sensors. Results are interpreted by comparing different trials: the test is applied to an intact femur sample which is taken as a reference, and then this test is repeated over the same sample with an implanted prosthesis. From comparison between results, immediate conclusions about the effects of the implantation of the prosthesis can be obtained. It must be said that the implementation has been made by an expert orthopedic surgeon using the same techniques and instruments as those used in clinical surgery. He has worked with three commercial femoral stems. From the results obtained in the time and frequency domains for the different applications the following conclusions have been established: Feasibility of the different types of synthetic samples: simplified models and standardized synthetic femur. Repeatability, linearity and reversibility of the testing method. Consistency of results with theoretical values deduced from the bars free oscillations theory. Effects of introduction of femoral stems in the amplitude, damping and frequencies of oscillations Detection of micromobility associated harmonics. This methodology has been proved suitable to be included in the standardization process of arthroplasty prosthesis, it is universally applicable and it allows establishing new methods for the analysis, detection and characterization of prosthesis micromobility due to functional loads.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

La calidad del hormigón prefabricado se determina mediante ensayos de rotura a compresión en probetas transcurridos los 28 días de curado, según establece la EHE-08. Sin embargo, en la plantas de prefabricados es necesario además saber cuándo el hormigón está listo para ser procesado (destensado, cortado, trasladado), por lo que es necesario hacer ensayos de resistencia a la compresión entre las 48 y 72 horas, este tiempo se determina a partir de la experiencia previa adquirida y depende de las condiciones de cada planta. Si las probetas no han alcanzado el valor establecido, normalmente debido a un cambio en las condiciones climatológicas o en los materiales utilizados como el tipo de cemento o agregados, la solución adoptada suele ser dejar curar el material más horas en la pista para que alcance la resistencia necesaria para ser procesado. Si sigue sin alcanzarla, lo cual sucede muy ocasionalmente, se intenta analizar cuál ha sido el motivo, pudiéndose tirar toda la producción de ese día si se comprueba que ha sido un fallo en la fabricación de la línea, y no un fallo de la probeta. Por tanto, esta metodología de control de calidad, basada en técnicas destructivas, supone dos tipos de problemas, costes y representatividad. Los métodos no destructivos que más se han aplicado para caracterizar el proceso de curado del hormigón son los ultrasónicos y la medida de la temperatura como se recoge en la bibliografía consultada. Hay diferentes modelos que permiten establecer una relación entre la temperatura y el tiempo de curado para estimar la resistencia a compresión del material, y entre la velocidad de propagación ultrasónica y la resistencia. Aunque estas relaciones no son generales, se han obtenido muy buenos resultados, ejemplo de ello es el modelo basado en la temperatura, Maturity Method, que forma parte de la norma de la ASTM C 1074 y en el mercado hay disponibles equipos comerciales (maturity meters) para medir el curado del hormigón. Además, es posible diseñar sistemas de medida de estos dos parámetros económicos y robustos; por lo cual es viable la realización de una metodología para el control de calidad del curado que pueda ser implantado en las plantas de producción de prefabricado. En este trabajo se ha desarrollado una metodología que permite estimar la resistencia a la compresión del hormigón durante el curado, la cual consta de un procedimiento para el control de calidad del prefabricado y un sistema inalámbrico de sensores para la medida de la temperatura y la velocidad ultrasónica. El procedimiento para el control de calidad permite realizar una predicción de la resistencia a compresión a partir de un modelo basado en la temperatura de curado y otros dos basados en la velocidad, método de tiempo equivalente y método lineal. El sistema inalámbrico de sensores desarrollado, WilTempUS, integra en el mismo dispositivo sensores de temperatura, humedad relativa y ultrasonidos. La validación experimental se ha realizado mediante monitorizaciones en probetas y en las líneas de prefabricados. Los resultados obtenidos con los modelos de estimación y el sistema de medida desarrollado muestran que es posible predecir la resistencia en prefabricados de hormigón en planta con errores comparables a los aceptables por norma en los ensayos de resistencia a compresión en probetas. ABSTRACT Precast concrete quality is determined by compression tests breakage on specimens after 28 days of curing, as established EHE-08. However, in the precast plants is also necessary to know when the concrete is ready to be processed (slack, cut, moved), so it is necessary to test the compressive strength between 48 and 72 hours. This time is determined from prior experience and depends on the conditions of each plant. If the samples have not reached the set value, usually due to changes in the weather conditions or in the materials used as for example the type of cement or aggregates, the solution usually adopted is to cure the material on track during more time to reach the required strength for processing. If the material still does not reach this strength, which happens very occasionally, the reason of this behavior is analyzed , being able to throw the entire production of that day if there was a failure in the manufacturing line, not a failure of the specimen. Therefore, this method of quality control, using destructive techniques, involves two kinds of problems, costs and representativeness. The most used non-destructive methods to characterize the curing process of concrete are those based on ultrasonic and temperature measurement as stated in the literature. There are different models to establish a relationship between temperature and the curing time to estimate the compressive strength of the material, and between the ultrasonic propagation velocity and the compressive strength. Although these relationships are not general, they have been very successful, for example the Maturity Method is based on the temperature measurements. This method is part of the standards established in ASTM C 1074 and there are commercial equipments available (maturity meters) in the market to measure the concrete curing. Furthermore, it is possible to design inexpensive and robust systems to measure ultrasounds and temperature. Therefore is feasible to determine a method for quality control of curing to be implanted in the precast production plants. In this work, it has been developed a methodology which allows to estimate the compressive strength of concrete during its curing process. This methodology consists of a procedure for quality control of the precast concrete and a wireless sensor network to measure the temperature and ultrasonic velocity. The procedure for quality control allows to predict the compressive strength using a model based on the curing temperature and two other models based on ultrasonic velocity, the equivalent time method and the lineal one. The wireless sensor network, WilTempUS, integrates is the same device temperature, relative humidity and ultrasonic sensors. The experimental validation has been carried out in cubic specimens and in the production plants. The results obtained with the estimation models and the measurement system developed in this thesis show that it is possible to predict the strength in precast concrete plants with errors within the limits of the standards for testing compressive strength specimens.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nondestructive techniques are widely used to assess existing timber structures. The models proposed for these methods are usually performed in the laboratory using small clear wood specimens. But in real situations many anomalies, defects and biological damage are found in wood. In these cases the existing models only indicate that the values are outside normality without providing any other information. To solve this problem, a study of non-destructive probing methods for wood was performed, testing the behaviour of four different techniques (penetration resistance, pullout resistance, drill resistance and chip drill extraction) on wood samples with different biological damage, simulating an in-situ test. The wood samples were obtained from existing Spanish timber structures with biotic damage caused by borer insects, termites, brown rot and white rot. The study concludes that all of the methods offer more or less detailed information about the degree of deterioration of wood, but that the first two methods (penetration and pullout resistance) cannot distinguish between pathologies. On the other hand, drill resistance and chip drill extraction make it possible to differentiate pathologies and even to identify species or damage location. Finally, the techniques used were compared to characterize their advantages and disadvantages.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

El objetivo definitivo de esta investigación es contribuir con la profundización del conocimiento en las tecnologías de remediación, específicamente las térmicas, debido a que la contaminación de suelos es motivo de preocupación por ser uno de los graves impactos ambientales que origina el hombre con sus actividades, especialmente las industriales, afectando a la salud de los seres humanos, y el medio ambiente, representando elevados costes de saneamiento y en ocasiones problemas graves de salud de las comunidades aledañas. Se establecen tres fases de investigación. En la primera se diseña el sistema de termodesorción a escala piloto, se desarrolla las corridas experimentales, la segunda con corridas en laboratorio para investigar sobre los parámetros que intervienen en el proyecto. Se hacen las corridas respectivas para determinar la eficacia del sistema, y la tercera fase que consiste en comparar los modelos teóricos de Hartley, con los de Hartley Graham –Bryce y el de Hamaker para determinar su aproximación con los resultados reales. Apoyado en investigaciones anteriores, se diseñó y construyó un sistema de desorción térmica, el cual consiste en un horno tipo caja con 4 calentadores (resistencias), y una campana con un filtro para evitar la contaminación atmosférica, así mismo, se diseñó un sistema de control que permitió hacer las corridas con 1/3 de la potencia, con una relación de encendido apagado 3:1 respectivamente. Para validar los resultados obtenidos en el estudio matemático, se compararon dos modelos con la finalidad cuál de ellos se aproxima más a la realidad, se tomaron los ensayos con sus tiempos de operación a las temperaturas y se trabajó a distintas bandas de temperaturas para verificar la fiabilidad del proceso matemático. La temperatura es un variable importante en los procesos de desorción, como los son también la humedad del suelo, pues esta va influir directamente en el tiempo de remediación, por lo que es importante tomarla en cuenta. De igual forma el tipo de suelo va influir en los resultados, siendo las arenas más aptas para este tipo de remediación. Los resultados de la modelización son presentados para temperaturas constantes, el cual difiere de la realidad, pues el proceso de calentamiento es lento y va en accenso dependiendo del contenido de humedad y de las propiedades del suelo. La experimentación realizada concluye con buenos resultados de la aplicación de sistemas de desorción de acuerdo a las variables de Panamá. Con relación al grado de cumplimiento respecto a las normativas actuales relacionadas a los límites máximos permitidos. Los resultados garantizan las posibilidades del proceso de remediación térmica de suelos contaminados con combustibles en rango de diésel, garantizando niveles aceptables de limpieza en un tiempo menor a otras metodologías no destructivas pudieran tomar. ABSTRACT The ultimate goal of this investigation is to enhance the pool of knowledge related to remediation technologies, specifically thermal desorption. The motivation for this study is based on concerns due to pollution of land as one of the most serious environmental impacts caused by anthropogenic effects, specially industrial activities, affecting human health and the environment in general, which represents high reclamation costs, and in some cases, serious health issues in nearby communities. Three phases have been established for this study. The first phase involves the design of a thermal desorption system as a pilot experiment, and associated tests. The second phase consists of laboratory testing to investigate the parameters that affect the investigation, as well as to determine the efficacy of the system. The third phase covers the comparison of theorical models as proposed by Hartley, Hartley Graham – Bryce, and Hamaker, as well as the evaluation of these models versus the laboratory results. Supported by previous researches, the thermal desorption system was designed and installed as a “box” type oven with four heaters (resistances) and one absorption hood with a filter to avoid atmospheric contamination. In the same way, a control system was designed allowing testing with 1/3 of the power, with an on/off rate of 3:1 respectively. In order to validate the results, two mathematical models were compared to identify which model is closer to the experimental results; test results were documented with respective durations and temperatures; and experiments were executed using different ranges of temperature to validate the consistency of the mathematical process. Temperature is an important variable that should be considered for the desorption processes, as well as the humidity content within the soil, that has direct influence over the required duration to achieve remediation. In the same manner, the type of soil also influences the results, where sands are more efficient for this type of remediation process. The results from this experiment are according to constant temperatures, which is not a complete representation of the reality, as the heating process is slow and the temperature gradually increases according to the humidity content and other properties of the soil. The experiment shows good results for the application of thermal desorption systems according to the variables in Panama, as well as the level of compliance required to fulfill current regulations and mandatory maximum limits. The results guarantee the possibility of soil thermo-remediation as a resource to clean sites that have been polluted with diesel-like combustibles, allowing acceptable levels in a period of time that is lower than with other non-destructive remediation technics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Commercial off-the-shelf microprocessors are the core of low-cost embedded systems due to their programmability and cost-effectiveness. Recent advances in electronic technologies have allowed remarkable improvements in their performance. However, they have also made microprocessors more susceptible to transient faults induced by radiation. These non-destructive events (soft errors), may cause a microprocessor to produce a wrong computation result or lose control of a system with catastrophic consequences. Therefore, soft error mitigation has become a compulsory requirement for an increasing number of applications, which operate from the space to the ground level. In this context, this paper uses the concept of selective hardening, which is aimed to design reduced-overhead and flexible mitigation techniques. Following this concept, a novel flexible version of the software-based fault recovery technique known as SWIFT-R is proposed. Our approach makes possible to select different registers subsets from the microprocessor register file to be protected on software. Thus, design space is enriched with a wide spectrum of new partially protected versions, which offer more flexibility to designers. This permits to find the best trade-offs between performance, code size, and fault coverage. Three case studies have been developed to show the applicability and flexibility of the proposal.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The paper presents the analysis of an important historical building: the Saint James Theater in the city of Corfù (Greece) actually used as the Municipality House. The building, located in the center of the city, is made of carves stones and is characterized by a stocky shape and by the presence of wooden floors. The study deals with the structural identification of such structure through the analysis of its ambient vibrations recorded by means of accelerometers with high accuracy. A full dynamic testing was developed using ambient vibrations to identify the main modal parameters and to make a non-destructive characterization of this building. The results of these dynamic tests are compared with the modal analysis of a complex finite element (FE) simulation of the structure. This analysis may present several problems and uncertainties for this stocky building. Due to the presence of wooden floors, the local modes can be highly excited and, as a consequence, the evaluation of the structural modal parameters presents some difficulties.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This thesis considers two basic aspects of impact damage in composite materials, namely damage severity discrimination and impact damage location by using Acoustic Emissions (AE) and Artificial Neural Networks (ANNs). The experimental work embodies a study of such factors as the application of AE as Non-destructive Damage Testing (NDT), and the evaluation of ANNs modelling. ANNs, however, played an important role in modelling implementation. In the first aspect of the study, different impact energies were used to produce different level of damage in two composite materials (T300/914 and T800/5245). The impacts were detected by their acoustic emissions (AE). The AE waveform signals were analysed and modelled using a Back Propagation (BP) neural network model. The Mean Square Error (MSE) from the output was then used as a damage indicator in the damage severity discrimination study. To evaluate the ANN model, a comparison was made of the correlation coefficients of different parameters, such as MSE, AE energy, AE counts, etc. MSE produced an outstanding result based on the best performance of correlation. In the second aspect, a new artificial neural network model was developed to provide impact damage location on a quasi-isotropic composite panel. It was successfully trained to locate impact sites by correlating the relationship between arriving time differences of AE signals at transducers located on the panel and the impact site coordinates. The performance of the ANN model, which was evaluated by calculating the distance deviation between model output and real location coordinates, supports the application of ANN as an impact damage location identifier. In the study, the accuracy of location prediction decreased when approaching the central area of the panel. Further investigation indicated that this is due to the small arrival time differences, which defect the performance of ANN prediction. This research suggested increasing the number of processing neurons in the ANNs as a practical solution.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this project was to carry out a fundamental study to assess the potential of colour image analysis for use in investigations of fire damaged concrete. This involved:(a) Quantification (rather than purely visual assessment) of colour change as an indicator of the thermal history of concrete.(b) Quantification of the nature and intensity of crack development as an indication of the thermal history of concrete, supporting and in addition to, colour change observations.(c) Further understanding of changes in the physical and chemical properties of aggregate and mortar matrix after heating.(d) An indication of the relationship between cracking and non-destructive methods of testing e.g. UPV or Schmidt hammer. Results showed that colour image analysis could be used to quantify the colour changes found when concrete is heated. Development of red colour coincided with significant reduction in compressive strength. Such measurements may be used to determine the thermal history of concrete by providing information regarding the temperature distribution that existed at the height of a fire. The actual colours observed depended on the types of cement and aggregate that were used to make the concrete. With some aggregates it may be more appropriate to only analyse the mortar matrix. Petrographic techniques may also be used to determine the nature and density of cracks developing at elevated temperatures and values of crack density correlate well with measurements of residual compressive strength. Small differences in crack density were observed with different cements and aggregates, although good correlations were always found with the residual compressive strength. Taken together these two techniques can provide further useful information for the evaluation of fire damaged concrete. This is especially so since petrographic analysis can also provide information on the quality of the original concrete such as cement content and water / cement ratio. Concretes made with blended cements tended to produce small differences in physical and chemical properties compared to those made with unblended cements. There is some evidence to suggest that a coarsening of pore structure in blended cements may lead to onset of cracking at lower temperatures. The use of DTA/TGA was of little use in assessing the thermal history of concrete made with blended cements. Corner spalling and sloughing off, as observed in columns, was effectively reproduced in tests on small scale specimens and the crack distributions measured. Relationships between compressive strength/cracking and non-destructive methods of testing are discussed and an outline procedure for site investigations of fire damaged concrete is described.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This thesis focuses on the investigation of the abrasion resistance of fibre reinforced concrete floors at both the macro and micro levels. A literature review of the available literature concerning subjects allied to the current project is included. This highlights themes relevant to wear mechanisms and the factors influencing it: factors that affect the abrasion resistance of concrete and several test methods for assessing it; and the historical development of fibres and the properties of different fibre types and their influence on concrete. Three accelerated abrasion testers were compared and critically discussed for their suitability for assessing the abrasion resistance of concrete floors. Based on the experimental findings one accelerated abrasion apparatus was selected as more appropriate to be used for carrying out the main investigations. The laboratory programme that followed was undertaken to investigate the influence of various material and construction factors on abrasion resistance. These included mix variations (w/c ratio), fibre reinforcement, geometry, type and volume, curing method and superplasticizing agents. The results clearly show that these factors significantly affected abrasion resistance and several mechanisms were presumed to explain and better understand these observations. To verify and understand these mechanisms that are accountable for the breakdown of concrete slabs, the same concrete specimens that were used for the macro-study, were also subjected to microstructutural investigations using techniques such as Microhardness examination, Mercury intrusion porosimetry and Petrographic examination. It has been found that the abrasion resistance of concrete is primarily dependent on the microstructure and porosity of the concrete nearest to the surface. The feasibility of predicting the abrasion resistance of fibre reinforced concrete floors by indirect and non-destructive methods was investigated using five methods that have frequently been used for assessing the quality of concrete. They included the initial surface absorption test, the impact test, ball cratering, the scratch test and the base hardness test. The impact resistance (BRE screed tester) and scratch resistance (Base hardness tester) were found to be the most sensitive to factors affecting abrasion resistance and hence are considered to be the most appropriate testing techniques. In an attempt to develop an appropriate method for assessing the abrasion resistance of heavy-duty industrial concrete floors, it was found that the presence of curing/sealing compound on the concrete surface at the time of accelerated abrasion testing produces inappropriate results. A preliminary investigation in the direction of modifying the Aston accelerated abrasion tester has been carried out and a more aggressive head has been developed and is pending future research towards standardisation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Stereotype threat (Steele & Aronson, 1995) refers to the risk of confirming a negative stereotype about one’s group in a particular performance domain. The theory assumes that performance in the stereotyped domain is most negatively affected when individuals are more highly identified with the domain in question. As federal law has increased the importance of standardized testing at the elementary level, it can be reasonably hypothesized that the standardized test performance of African American children will be depressed when they are aware of negative societal stereotypes about the academic competence of African Americans. This sequential mixed-methods study investigated whether the standardized testing experiences of African American children in an urban elementary school are related to their level of stereotype awareness. The quantitative phase utilized data from 198 African American children at an urban elementary school. Both ex-post facto and experimental designs were employed. Experimental conditions were diagnostic and non-diagnostic testing experiences. The qualitative phase utilized data from a series of six focus group interviews conducted with a purposefully selected group of 4 African American children. The interview data were supplemented with data from 30 hours of classroom observations. Quantitative findings indicated that the stereotype threat condition evoked by diagnostic testing depresses the reading test performance of stereotype-aware African American children (F[1, 194] = 2.21, p < .01). This was particularly true of students who are most highly domain-identified with reading (F[1, 91] = 19.18, p < .01). Moreover, findings indicated that only stereotype-aware African American children who were highly domain-identified were more likely to experience anxiety in the diagnostic condition (F[1, 91] = 5.97, p < .025). Qualitative findings revealed 4 themes regarding how African American children perceive and experience the factors related to stereotype threat: (1) a narrow perception of education as strictly test preparation, (2) feelings of stress and anxiety related to the state test, (3) concern with what “others” think (racial salience), and (4) stereotypes. A new conceptual model for stereotype threat is presented, and future directions including implications for practice and policy are discussed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Stereotype threat (Steele & Aronson, 1995) refers to the risk of confirming a negative stereotype about one’s group in a particular performance domain. The theory assumes that performance in the stereotyped domain is most negatively affected when individuals are more highly identified with the domain in question. As federal law has increased the importance of standardized testing at the elementary level, it can be reasonably hypothesized that the standardized test performance of African American children will be depressed when they are aware of negative societal stereotypes about the academic competence of African Americans. This sequential mixed-methods study investigated whether the standardized testing experiences of African American children in an urban elementary school are related to their level of stereotype awareness. The quantitative phase utilized data from 198 African American children at an urban elementary school. Both ex-post facto and experimental designs were employed. Experimental conditions were diagnostic and non-diagnostic testing experiences. The qualitative phase utilized data from a series of six focus group interviews conducted with a purposefully selected group of 4 African American children. The interview data were supplemented with data from 30 hours of classroom observations. Quantitative findings indicated that the stereotype threat condition evoked by diagnostic testing depresses the reading test performance of stereotype-aware African American children (F[1, 194] = 2.21, p < .01). This was particularly true of students who are most highly domain-identified with reading (F[1, 91] = 19.18, p < .01). Moreover, findings indicated that only stereotype-aware African American children who were highly domain-identified were more likely to experience anxiety in the diagnostic condition (F[1, 91] = 5.97, p < .025). Qualitative findings revealed 4 themes regarding how African American children perceive and experience the factors related to stereotype threat: (1) a narrow perception of education as strictly test preparation, (2) feelings of stress and anxiety related to the state test, (3) concern with what “others” think (racial salience), and (4) stereotypes. A new conceptual model for stereotype threat is presented, and future directions including implications for practice and policy are discussed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Scatter in medical imaging is typically cast off as image-related noise that detracts from meaningful diagnosis. It is therefore typically rejected or removed from medical images. However, it has been found that every material, including cancerous tissue, has a unique X-ray coherent scatter signature that can be used to identify the material or tissue. Such scatter-based tissue-identification provides the advantage of locating and identifying particular materials over conventional anatomical imaging through X-ray radiography. A coded aperture X-ray coherent scatter spectral imaging system has been developed in our group to classify different tissue types based on their unique scatter signatures. Previous experiments using our prototype have demonstrated that the depth-resolved coherent scatter spectral imaging system (CACSSI) can discriminate healthy and cancerous tissue present in the path of a non-destructive x-ray beam. A key to the successful optimization of CACSSI as a clinical imaging method is to obtain anatomically accurate phantoms of the human body. This thesis describes the development and fabrication of 3D printed anatomical scatter phantoms of the breast and lung.

The purpose of this work is to accurately model different breast geometries using a tissue equivalent phantom, and to classify these tissues in a coherent x-ray scatter imaging system. Tissue-equivalent anatomical phantoms were designed to assess the capability of the CACSSI system to classify different types of breast tissue (adipose, fibroglandular, malignant). These phantoms were 3D printed based on DICOM data obtained from CT scans of prone breasts. The phantoms were tested through comparison of measured scatter signatures with those of adipose and fibroglandular tissue from literature. Tumors in the phantom were modeled using a variety of biological tissue including actual surgically excised benign and malignant tissue specimens. Lung based phantoms have also been printed for future testing. Our imaging system has been able to define the location and composition of the various materials in the phantom. These phantoms were used to characterize the CACSSI system in terms of beam width and imaging technique. The result of this work showed accurate modeling and characterization of the phantoms through comparison of the tissue-equivalent form factors to those from literature. The physical construction of the phantoms, based on actual patient anatomy, was validated using mammography and computed tomography to visually compare the clinical images to those of actual patient anatomy.