925 resultados para Non Medical Prescribing


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A substantial number of medical students in India have to bear an enormous financial burden for earning a bachelor's degree in medicine referred to as MBBS (bachelor of medicine and bachelor of surgery). This degree program lasts for four and one-half years followed by one year of internship. A postgraduate degree, such as MD, has to be pursued separately on completion of a MBBS. Every medical college in India is part of a hospital where the medical students get clinical exposure during the course of their study. All or at least a number of medical colleges in a given state are affiliated to a university that mainly plays a role of an overseeing authority. The medical colleges usually have no official interaction with other disciplines of education such as science and engineering, perhaps because of their independent location and absence of emphasis on medical research. However, many of the medical colleges are adept in imparting high-quality and sound training in medical practices including diagnostics and treatment. The medical colleges in India are generally of two types, i.e., government owned and private. Since only a limited number of seats are available across India in the former category of colleges, only a small fraction of aspiring candidates can find admission in these colleges after performing competitively in the relevant entrance tests. A major advantage of studying in these colleges is the nominal tuition fees that have to be paid. On the other hand, a large majority of would-be medical graduates have to seek admission in the privately run medical institutes in which the tuition and other related fees can be mind boggling when compared to their public counterparts. Except for candidates of exceptionally affluent background, the only alternative for fulfilling the dream of becoming a doctor is by financing one's study through hefty bank loans that may take years to pay back. It is often heard from patients that they are asked by doctors to undergo a plethora of diagnostic tests for apparently minor illnesses, which may financially benefit those prescribing the tests. The present paper attempts to throw light on the extent of disparity in cost of a medical education between state-funded and privately managed medical colleges in India; the average salary of a new medical graduate, which is often ridiculously low when compared to what is offered in entry-level engineering and business jobs; and the possible repercussions of this apparently unjust economic situation regarding the exploitation of patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Clustering techniques which can handle incomplete data have become increasingly important due to varied applications in marketing research, medical diagnosis and survey data analysis. Existing techniques cope up with missing values either by using data modification/imputation or by partial distance computation, often unreliable depending on the number of features available. In this paper, we propose a novel approach for clustering data with missing values, which performs the task by Symmetric Non-Negative Matrix Factorization (SNMF) of a complete pair-wise similarity matrix, computed from the given incomplete data. To accomplish this, we define a novel similarity measure based on Average Overlap similarity metric which can effectively handle missing values without modification of data. Further, the similarity measure is more reliable than partial distances and inherently possesses the properties required to perform SNMF. The experimental evaluation on real world datasets demonstrates that the proposed approach is efficient, scalable and shows significantly better performance compared to the existing techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Because the excreted sporocysts and/or oocysts of various species of Sarcocystis may not be discriminated morphologically, we sought to validate a diagnostic technique based on variation in the 18S rDNA sequence. Oocysts and/or sporocysts; from three taxa

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: A single case of paternal co-transmission ofmitochondrial DNA (mtDNA) in humans has been reported so far. Objective: To find potential instances of non-maternal inheritance of mtDNA. Methods: Published medical case studies (of single patients) were searched for irregular mtDNA patterns by comparing the given haplotype information for different clones or tissues with the worldwide mtDNA database as known to date-a method that has proved robust and reliable for the detection of flawed mtDNA sequence data. Results: More than 20 studies were found reporting clear cut instances with mtDNAs of different ancestries in single individuals. As examples, cases are reviewed from recent published reports which, at face value, may be taken as evidence for paternal inheritance of mtDNA or recombination. Conclusions: Multiple types (or recombinant types) of quite dissimilar mitochondrial DNA from different parts of the known mtDNA phylogeny are often reported in single individuals. From re-analyses and corrigenda of forensic mtDNA data, it is apparent that the phenomenon of mixed or mosaic mtDNA can be ascribed solely to contamination and sample mix up.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It has been demonstrated that growth hormone (GH) transgenic fish often posses a trait for fast growth. Here, we investigated the growth of F-4 'all-fish' GH transgenic carp Cyprinus carpio and their serum GH levels for a year. The results showed that F-4 all-fish GH transgenic carp were significantly larger in body mass (c. two-fold, P < 0 center dot 001) and body length (c. 1 center dot 3 fold, P < 0 center dot 001), compared with the non-transgenic group. The discrepancy of serum GH levels between the transgenic carp group and control group is 54 fold, when the water temperature was 12-34 degrees C. When the water temperature decreased to 3 center dot 5 degrees C in January, the discrepancy was 256 fold. The serum GH level of the transgenic group was relatively constant, while that of control varied greatly based on month and water temperature. The changes of growth rates between the transgenic group and the control group were similar for a year. Taken together, the results indicated that F-4 all-fish GH transgenic carp had not only higher and constant serum GH levels but also a significant fast-growing effect, compared with the control. To our knowledge, this is the first report on a one-year investigation of growth trait and serum growth hormone level in F-4 all-fish GH transgenic carp.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The administration of psychotropic and psychoactive medication for persons with learning disability and accompanying mental illness and/or challenging behaviour has undergone much critical review over the past two decades. Assessment and diagnosis of mental illness in this population continues to be psychopharmacological treatment include polypharmacy, irrational prescription procedures and frequent over-prescription. It is clear that all forms of treatment including non-pharmacological interventions need to be driven by accurate and appropriate diagnoses. Where a psychiatric diagnosis has been identified, it greatly aides the selection of appropriate medication, although a specific medication for each diagnosis, as was once hoped, is simply no longer a reality in practice. Part one of the present thesis seeks to address many of the current issues in mental health problems and pharmacological treatment to date. The author undertook a drug prevalence study within both residential and community facilities for persons with learning disability within the Mid-West region of Ireland in order to ascertain the current level of prescribing of psychotropic and psychoactive medications for this population. While many attempts have been made to account for the variation in prescribing, little systematic and empirical research has been undertaken to investigate the factors thought to influence such prescribing. While studies investigating the prescribing behaviours of General Practitioners (GP's) have illustrated the complex nature of the decision making process in the context of general practice, no similar efforts have yet been directed at examining the prescribing behaviours of Consultant Psychiatrists. Using The Critical Incident Technique, the author interviewed Consultant Psychiatrists in the Republic of Ireland to gather information relating not only to their patterns of prescribing for learning disabled populations, but also to examine reasons influencing their prescribing in addition to several related factors. Part two of this thesis presents the findings from this study and a number of issues are raised, not only in relation to attempting to account for the findings from part one of the thesis, but also with respect to implications for improved management and clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Emergency departments are challenging research settings, where truly informed consent can be difficult to obtain. A deeper understanding of emergency medical patients' opinions about research is needed. We conducted a systematic review and meta-summary of quantitative and qualitative studies on which values, attitudes, or beliefs of emergent medical research participants influence research participation. We included studies of adults that investigated opinions toward emergency medicine research participation. We excluded studies focused on the association between demographics or consent document features and participation and those focused on non-emergency research. In August 2011, we searched the following databases: MEDLINE, EMBASE, Google Scholar, Scirus, PsycINFO, AgeLine and Global Health. Titles, abstracts and then full manuscripts were independently evaluated by two reviewers. Disagreements were resolved by consensus and adjudicated by a third author. Studies were evaluated for bias using standardised scores. We report themes associated with participation or refusal. Our initial search produced over 1800 articles. A total of 44 articles were extracted for full-manuscript analysis, and 14 were retained based on our eligibility criteria. Among factors favouring participation, altruism and personal health benefit had the highest frequency. Mistrust of researchers, feeling like a 'guinea pig' and risk were leading factors favouring refusal. Many studies noted limitations of informed consent processes in emergent conditions. We conclude that highlighting the benefits to the participant and society, mitigating risk and increasing public trust may increase research participation in emergency medical research. New methods for conducting informed consent in such studies are needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The outcomes for both (i) radiation therapy and (ii) preclinical small animal radio- biology studies are dependent on the delivery of a known quantity of radiation to a specific and intentional location. Adverse effects can result from these procedures if the dose to the target is too high or low, and can also result from an incorrect spatial distribution in which nearby normal healthy tissue can be undesirably damaged by poor radiation delivery techniques. Thus, in mice and humans alike, the spatial dose distributions from radiation sources should be well characterized in terms of the absolute dose quantity, and with pin-point accuracy. When dealing with the steep spatial dose gradients consequential to either (i) high dose rate (HDR) brachytherapy or (ii) within the small organs and tissue inhomogeneities of mice, obtaining accurate and highly precise dose results can be very challenging, considering commercially available radiation detection tools, such as ion chambers, are often too large for in-vivo use.

In this dissertation two tools are developed and applied for both clinical and preclinical radiation measurement. The first tool is a novel radiation detector for acquiring physical measurements, fabricated from an inorganic nano-crystalline scintillator that has been fixed on an optical fiber terminus. This dosimeter allows for the measurement of point doses to sub-millimeter resolution, and has the ability to be placed in-vivo in humans and small animals. Real-time data is displayed to the user to provide instant quality assurance and dose-rate information. The second tool utilizes an open source Monte Carlo particle transport code, and was applied for small animal dosimetry studies to calculate organ doses and recommend new techniques of dose prescription in mice, as well as to characterize dose to the murine bone marrow compartment with micron-scale resolution.

Hardware design changes were implemented to reduce the overall fiber diameter to <0.9 mm for the nano-crystalline scintillator based fiber optic detector (NanoFOD) system. Lower limits of device sensitivity were found to be approximately 0.05 cGy/s. Herein, this detector was demonstrated to perform quality assurance of clinical 192Ir HDR brachytherapy procedures, providing comparable dose measurements as thermo-luminescent dosimeters and accuracy within 20% of the treatment planning software (TPS) for 27 treatments conducted, with an inter-quartile range ratio to the TPS dose value of (1.02-0.94=0.08). After removing contaminant signals (Cerenkov and diode background), calibration of the detector enabled accurate dose measurements for vaginal applicator brachytherapy procedures. For 192Ir use, energy response changed by a factor of 2.25 over the SDD values of 3 to 9 cm; however a cap made of 0.2 mm thickness silver reduced energy dependence to a factor of 1.25 over the same SDD range, but had the consequence of reducing overall sensitivity by 33%.

For preclinical measurements, dose accuracy of the NanoFOD was within 1.3% of MOSFET measured dose values in a cylindrical mouse phantom at 225 kV for x-ray irradiation at angles of 0, 90, 180, and 270˝. The NanoFOD exhibited small changes in angular sensitivity, with a coefficient of variation (COV) of 3.6% at 120 kV and 1% at 225 kV. When the NanoFOD was placed alongside a MOSFET in the liver of a sacrificed mouse and treatment was delivered at 225 kV with 0.3 mm Cu filter, the dose difference was only 1.09% with use of the 4x4 cm collimator, and -0.03% with no collimation. Additionally, the NanoFOD utilized a scintillator of 11 µm thickness to measure small x-ray fields for microbeam radiation therapy (MRT) applications, and achieved 2.7% dose accuracy of the microbeam peak in comparison to radiochromic film. Modest differences between the full-width at half maximum measured lateral dimension of the MRT system were observed between the NanoFOD (420 µm) and radiochromic film (320 µm), but these differences have been explained mostly as an artifact due to the geometry used and volumetric effects in the scintillator material. Characterization of the energy dependence for the yttrium-oxide based scintillator material was performed in the range of 40-320 kV (2 mm Al filtration), and the maximum device sensitivity was achieved at 100 kV. Tissue maximum ratio data measurements were carried out on a small animal x-ray irradiator system at 320 kV and demonstrated an average difference of 0.9% as compared to a MOSFET dosimeter in the range of 2.5 to 33 cm depth in tissue equivalent plastic blocks. Irradiation of the NanoFOD fiber and scintillator material on a 137Cs gamma irradiator to 1600 Gy did not produce any measurable change in light output, suggesting that the NanoFOD system may be re-used without the need for replacement or recalibration over its lifetime.

For small animal irradiator systems, researchers can deliver a given dose to a target organ by controlling exposure time. Currently, researchers calculate this exposure time by dividing the total dose that they wish to deliver by a single provided dose rate value. This method is independent of the target organ. Studies conducted here used Monte Carlo particle transport codes to justify a new method of dose prescription in mice, that considers organ specific doses. Monte Carlo simulations were performed in the Geant4 Application for Tomographic Emission (GATE) toolkit using a MOBY mouse whole-body phantom. The non-homogeneous phantom was comprised of 256x256x800 voxels of size 0.145x0.145x0.145 mm3. Differences of up to 20-30% in dose to soft-tissue target organs was demonstrated, and methods for alleviating these errors were suggested during whole body radiation of mice by utilizing organ specific and x-ray tube filter specific dose rates for all irradiations.

Monte Carlo analysis was used on 1 µm resolution CT images of a mouse femur and a mouse vertebra to calculate the dose gradients within the bone marrow (BM) compartment of mice based on different radiation beam qualities relevant to x-ray and isotope type irradiators. Results and findings indicated that soft x-ray beams (160 kV at 0.62 mm Cu HVL and 320 kV at 1 mm Cu HVL) lead to substantially higher dose to BM within close proximity to mineral bone (within about 60 µm) as compared to hard x-ray beams (320 kV at 4 mm Cu HVL) and isotope based gamma irradiators (137Cs). The average dose increases to the BM in the vertebra for these four aforementioned radiation beam qualities were found to be 31%, 17%, 8%, and 1%, respectively. Both in-vitro and in-vivo experimental studies confirmed these simulation results, demonstrating that the 320 kV, 1 mm Cu HVL beam caused statistically significant increased killing to the BM cells at 6 Gy dose levels in comparison to both the 320 kV, 4 mm Cu HVL and the 662 keV, 137Cs beams.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To apply the UK Medical Research Council (MRC) framework for development and evaluation of trials of complex interventions to a primary healthcare intervention to promote secondary prevention of coronary heart disease. Study Design: Case report of intervention development. Methods: First, literature relating to secondary prevention and lifestyle change was reviewed. Second, a preliminary intervention was modeled, based on literature findings and focus group interviews with patients (n = 23) and staff (n = 29) from 4 general practices. Participants’ experiences of and attitudes toward key intervention components were explored. Third, the preliminary intervention was pilot-tested in 4 general practices. After delivery of the pilot intervention, practitioners evaluated the training sessions, and qualitative data relating to experiences of the intervention were collected using semistructured interviews with staff (n = 10) and patient focus groups (n = 17). Results: Literature review identified 3 intervention components: a structured recall system, practitioner training, and patient information. Initial qualitative data identified variations in recall system design, training requirements (medication prescribing, facilitating behavior change), and information appropriate to the prospective study participants. Identifying detailed structures within intervention components clarified how the intervention could be tailored to individual practice, practitioner, and patient needs while preserving the theoretical functions of the components. Findings from the pilot phase informed further modeling of the intervention, reducing administrative time, increasing practical content of training, and omitting unhelpful patient information. Conclusion: Application of the MRC framework helped to determine the feasibility and development of a complex intervention for primary care research.